1. Trang chủ
  2. » Kỹ Thuật - Công Nghệ

SPO GET OM 2012 03 v1

6 39 0

Đang tải... (xem toàn văn)

THÔNG TIN TÀI LIỆU

Thông tin cơ bản

Định dạng
Số trang 6
Dung lượng 765,24 KB

Nội dung

Stock Pot Stove Operator’s Manual www.profitind.com Stock Pot Stove Operator’s Manual SPO-1-GET SPO-2-GET SPO-1-GET/A SPO-2-GET/A This manual must be retained for future reference FOR YOUR SAFETY Do not store or use gasoline or other flammable vapors or liquids in the vicinity of this or any other appliance CAUTIONS • Improper • All rights reserved All trademarks are the property of their respective owners Reproduction in whole or in part without written permission is prohibited SPO-GET-OM-2012-03-V1 installation, adjustment, alteration, service or maintenance can cause property damage, injury or death Read the installation and operator’s instructions thoroughly before installing or servicing this equipment All installations must conform with local codes, or in the absence of local codes, with the National Fuel Gas Code, ANSI Z233.1 / NFPA 54 or Natural Gas and Propane Installation Code, CSA B149.1 NOTE: To keep this appliance area free and clear from combustibles Stock Pot Stove Operator’s Manual Stock Pot Stove Operator’s Manual Technical service contacts HONG KONG Pro-Fit Industrial Co Ltd Flat A, 8/F., Chung Shun Knitting Centre, 1-3 Wing Yip Street, Kwai Chung, N.T., Hong Kong Phone : (852) 2371-2862 Fax : (852) 2371-2867 E-mail : profit@profitind.com Website : www.profitind.com CHINA Guangdong Foshan Fordex Kitchen Utensils Co Ltd Phone : (86) 0757-86417222 Fax : (86) 0757-86417233 E-mail: foshan@profitind.com BEIJING Fortune-Cater Equipment Co., Ltd Phone : (86) 010-67676228 Fax : (86) 010-67620538 E-mail: bj@profitind.com SINGAPORE & MALAYSIA Phone : (60) 17-2255446 Fax : (603) 91714788 E-mail: shchew@profitind.com SPO-GET-OM-2012-03-V1 P Contents Specifications 2-4 Structure of the Stock Pot Stove Structure of the combustion system Operation manual General information and maintenance Technical service contacts Stock Pot Stove Operator’s Manual Specifications SPO-1-GET SPO-1-GET / A PRO-FIT - Brand : Power Flame SPO-1-GET Stock Pot Stove (TH Burner) - Ring Hong Kong, PRC Function Dimensions Safety For soup cooking (Chinese or Western Style) 550 x 650 x 500 mmH + 150mmH back splash (21.7” x 25.6” x 19.7”H + 5.9”H back splash) - The exterior body is constructed of 0.06” (1.5mm) thick stainless steel type 304 with no finishing - piece of 11” dia TH burner with pilot valve, flame failure device (safety valve) and main gas cock - Electrical requirement for solenoid 0.0101 kW (110-120V/1ph/50~60Hz) or (220-240V/1ph/50~60Hz) - Heat input : Propane Gas : 14.5 kW (49 476 BTU / hr ) Natural Gas : 14.5 kW (49 476 BTU / hr ) Stainless steel exterior body for easy cleaning - With standard electronic ignition device & flame failure device (safety valve) - stainless steel drip tray - Standard with safety valve – flame failure device Manufacturer Model no Product Description Origin PRO-FIT - Brand : Power Flame SPO-1-GET / A Stock Pot Stove (23-Jet Burner) - Ring Hong Kong, PRC Function Dimensions For soup cooking (Chinese or Western Style) 550 x 650 x 500 mmH + 150mmH back splash (21.7” x 25.6” x 19.7”H + 5.9”H back splash) - The exterior body is constructed of 0.06” (1.5mm) thick stainless steel type 304 with no finishing - piece of 10” (250mm) dia 23-Jet burner with pilot valve, flame failure device (safety valve) and main gas cock - Electrical requirement for solenoid 0.0101 kW (110-120V/1ph/50~60Hz) or (220-240V/1ph/50~60Hz) - Heat input : Town Gas : 20 kW (68 242 BTU / hr ) Stainless steel exterior body for easy cleaning - With standard electronic ignition device & flame failure device (safety valve) - stainless steel drip tray - Standard with safety valve – flame failure device Engineering / MEP ratings Sanitation Accessories Construction Engineering / MEP ratings Sanitation Accessories Safety SPO-GET-OM-2012-03-V1 IMPORTANT NOTES: – • Do not turn on the main gas valves unless the pilot flame is on • Ensure the kitchen ventilation system is on before operating the appliance • Keep the kitchen well ventilated at all the time WHAT TO DO IF YOU SMELL GAS: • Do not light any appliance • Do not touch any electric switch • Do not use any phone in your building • Immediately call your gas supplier from a phone outside the building • Follow your gas supplier’s instructions • If your gas supplier cannot be reached, call the fire department • Installation and service must be performed by a qualified installer, service agent or the gas supplier Manufacturer Model no Product Description Origin Construction P Stock Pot Stove Operator’s Manual General information and maintenance If the pilot light does not light up, not turn on the Main Gas Cock If the pilot does not light up, try to press the Electronic ignition button again If it still fails, inform the qualified service agent to take appropriate action on maintenance and replacement Remember to shut off the Pilot Light while not in cooking for an extended period of time The kitchen exhaust system must be turned on whenever the appliance is in operation Always pay attention to any gas leakage of the Main Gas Cock and connection joints of the gas pipes If there is leakage problem, shut off the main gas supply valve and then inform the qualified service agent for maintenance When the appliance is idle, clean it up and always keep it tidy To avoid damage on the stove body, not strike bulky and heavy objects onto the stove Maintenance and Time Intervals Descriptions Necessary works Body Drip tray Main gas cock Pilot light Safety control system General cleaning General cleaning Leakage check Leakage check Performance check Deep cleaning Performance check Performance check and replacement (if needed) Performance check and replacement (if needed) Burner Pilot ignited cable Automatic Pilot sensor ● Daily Weekly Every months Half-yearly ○ ○ ● ● ● ○ ● ● ○ Repair and maintenance must be done by qualified person ○ General maintenance can be carried out by end-users Note: Disconnect the power supply to the appliance before cleaning or servicing, if applicable For technical support, please refer to the page of Technical service contacts P SPO-GET-OM-2012-03-V1 Stock Pot Stove Operator’s Manual Stock Pot Stove Operator’s Manual Specifications Operation Manual Electronic ignition button Pilot light valve Main gas cock handle Flame failure device (safety valve) * This appliance is only for professional use and that it should be used by qualified people SPO-2-GET SPO-2-GET / A TURN ON a Before lighting the appliance, ensure all gas valves are in closed position b Turn on the Pilot Light (2) Press the Ignition Button (1) and the Flame failure device (safety valve) (4) simultaneously to light the pilot Once pilot flame is established, hold the buttons for 30 seconds c If the pilot flame is not lit, wait for minutes before attempting step (b) d Turn on the Main Gas Cock (3) until a desirable flame is obtained Step Step Turn on the pilot light Press the ignition button Press & hold the safety valve Step Turn on the main cock Manufacturer Model no Product Description Origin PRO-FIT - Brand : Power Flame SPO-2-GET Stock Pot Stove (TH Burner) - Rings Hong Kong, PRC Function Dimensions Safety For soup cooking (Chinese or Western Style) 1100 x 650 x 500 mmH + 150mmH back splash (43.3” x 25.6” x 19.7”H + 5.9” H back splash) - The exterior body is constructed of 0.06” (1.5mm) thick stainless steel type 304 with no finishing - pieces of 11” dia.TH burner with pilot valve, flame failure device (safety valve) and main gas cock - Electrical requirement for solenoid 0.0101 kW (110-120V/1ph/50~60Hz) or (220-240V/1ph/50~60Hz) - Heat Input : Propane Gas : 29 kW (98 952 BTU / hr ) Natural Gas : 29 kW (98 952 BTU / hr ) Stainless steel exterior body for easy cleaning - With standard electronic ignition device & flame failure device (safety valve) - stainless steel drip tray - Standard with safety valve – flame failure device Manufacturer Model no Product Description Origin PRO-FIT - Brand : Power Flame SPO-2-GET / A Stock Pot Stove (TH Burner) - Rings Hong Kong, PRC Function Dimensions For soup cooking (Chinese or Western Style) 1100 x 650 x 500 mmH + 150mmH back splash (43.3” x 25.6” x 19.7”H + 5.9” H back splash) - The exterior body is constructed of 0.06” (1.5mm) thick stainless steel type 304 with no finishing - pieces of 10” (250mm) dia 23-Jet burner with pilot valves, flame failure device (safety valve)s and main gas cocks - Electrical requirement for solenoid 0.0101 kW (110-120V/1ph/50~60Hz) or (220-240V/1ph/50~60Hz) - Heat Input : Town Gas : 40 kW (136 485 BTU/ hr ) Stainless steel exterior body for easy cleaning - With standard electronic ignition device & flame failure device (safety valve) - stainless steel drip tray - Standard with safety valve – flame failure device Construction Engineering / MEP ratings Sanitation Accessories SHUT OFF a For temporary shut off, just turn off the Main Gas Cock (3) Leave the Pilot Light (2) on b If the appliance is not in use, turn off all the gas valves Temporary shut off Not in use Leave the pilot light on Turn off the pilot light Turn off the main cock Turn off the main cock Construction Engineering / MEP ratings Sanitation Accessories Safety SPO-GET-OM-2012-03-V1 P P SPO-GET-OM-2012-03-V1 Stock Pot Stove Operator’s Manual Stock Pot Stove Operator’s Manual Specifications SPO-1-GET Structure of the combustion system SPO-2-GET 21.7” Single stock pot stove 43.3” Ø11” TH Burner BURNER TYPE Double stock pot stove Ø10” 23 Jets Burner Ø11” TH Burner Ø10” 23 Jets Burner 25.6” Model ► SPO-1-GET SPO-1-GET/A SPO-2-GET SPO-2-GET/A SPO-2-GET/A 25.6” SPO-1-GET/A 21.7” 5.9” 19.7” 5.9” 43.3” Dimensions Width x Depth x Height (inch) 21.7 x 25.6 x (19.7 + 5.9) 43.3 x 25.6 x (19.7 + 5.9) Width x Depth x Height (mm) 550 x 650 x (500 + 150) 1100 x 650 x (500 + 150) Solenoid Loading (kW) Voltage (V/Ph/Hz) 0.0101 (110~120/1/50~60) or (220~240/1/50~60) Heat input kW (BTU / hr.) Town Gas Nil 20 (68242) Nil 40 (136485) Propane (L.P Gas) 14.5 (49476) Nil 29 (98952) Nil Natural Gas 14.5 (49476) Nil 29 (98952) Nil Operating Pressure (inch in Water Column) Town Gas Propane (L.P Gas) 11 Natural Gas Fuel pipe connection (Ø inch) 0.75 47 / 85 82 / 135 Net / Gross Wt (kgs) The stove is constructed of major parts: the body with grate top and adjustable bullet feet, the burner with controls and drip tray Each ring of stock pot stove is equipped with a powerful 11 in (Ø280mm) TH burner / 10 in (Ø250mm) 23-Jet burner, pilot pipe and gas in orifice Main cock handle, pilot light, electronic ignition switch and flame failure device (safety valve) are located in the front control panel for easy daily operation 3a SPO-GET-OM-2012-03-V1 P 11 Structure of Stock Pot Stove 8a 10 7 1 SPO-1-GET No Parts Name SPO-1-GET /A Recommended Installed & adjusted by Installer Replacement Parts List and /or Service Agent Main gas valve & Handle (main cock) Flame failure device (safety valve) 9 Gas pipe 9 No Parts Name Black splash Cast iron grate TH burner Electronic ignition Pilot valve with knob Pilot head 9 Automatic Pilot Sensor 9 3a 23-Jet burner Ø11” (Ø280 mm) TH burner 9 Slide rail of drip tray Drip tray Front panel Side panel Adjustable bullet feet 8a Ø10” (Ø250 mm) 23-Jet burner 9 Gas cut solenoid 9 10 Ø1.5” (38mm) A-mode air-mixer 9 11 Main gas-in jet 9 P SPO-GET-OM-2012-03-V1 ... Safety SPO- GET- OM- 2012- 03- V1 P P SPO- GET- OM- 2012- 03- V1 Stock Pot Stove Operator’s Manual Stock Pot Stove Operator’s Manual Specifications SPO- 1 -GET Structure of the combustion system SPO- 2 -GET 21.7”... Jets Burner Ø11” TH Burner Ø10” 23 Jets Burner 25.6” Model ► SPO- 1 -GET SPO- 1 -GET/ A SPO- 2 -GET SPO- 2 -GET/ A SPO- 2 -GET/ A 25.6” SPO- 1 -GET/ A 21.7” 5.9” 19.7” 5.9” 43.3” Dimensions Width x Depth x Height... control panel for easy daily operation 3a SPO- GET- OM- 2012- 03- V1 P 11 Structure of Stock Pot Stove 8a 10 7 1 SPO- 1 -GET No Parts Name SPO- 1 -GET /A Recommended Installed & adjusted by Installer

Ngày đăng: 13/03/2019, 19:29

TÀI LIỆU CÙNG NGƯỜI DÙNG

TÀI LIỆU LIÊN QUAN