1. Trang chủ
  2. » Kỹ Thuật - Công Nghệ

Iec 60384 25 2015

64 0 0

Đang tải... (xem toàn văn)

Tài liệu hạn chế xem trước, để xem đầy đủ mời bạn chọn Tải xuống

THÔNG TIN TÀI LIỆU

Thông tin cơ bản

Định dạng
Số trang 64
Dung lượng 1,29 MB

Nội dung

I E C 60 4-2 ® Edition 2.0 201 5-07 I N TE RN ATI ON AL S TAN D ARD N ORM E I N TE RN ATI ON ALE F i xed capaci tors for u s e i n el ectron i c eq u i pm en t – P art 5: S e cti on al s pe ci fi cati on – F i xed al u m i n i u m e l ectrol yti c s u rface m ou n t capaci tors wi th d u cti ve pol ym er s ol i d el e ctrol yte C on d en s ate u rs fi xes u ti l i s és d an s l e s éq u i pe m e n ts él ectron i q u es – P arti e 5: S péci fi cati on i n term é d i re – C on d en s ateu rs fi xes él ectrol yti q u es en IEC 60384-25:201 5-07(en-fr) al u m i n i u m pou r m on tag e en s u rface é l ectrol yte s ol i d e e n pol ym è re d u cte u r T H I S P U B L I C AT I O N I S C O P YRI G H T P RO T E C T E D C o p yri g h t © I E C , G e n e v a , S wi tz e rl a n d All rights reserved Unless otherwise specified, no part of this publication may be reproduced or utilized in any form or by any means, electronic or mechanical, including photocopying and microfilm, without permission in writing from either IEC or IEC's member National Committee in the country of the requester If you have any questions about I EC copyright or have an enquiry about obtaining additional rights to this publication, please contact the address below or your local I EC member National Committee for further information Droits de reproduction réservés Sauf indication contraire, aucune partie de cette publication ne peut être reproduite ni utilisée sous quelque forme que ce soit et par aucun procédé, électronique ou mécanique, y compris la photocopie et les microfilms, sans l'accord écrit de l'IEC ou du Comité national de l'IEC du pays du demandeur Si vous avez des questions sur le copyright de l'IEC ou si vous désirez obtenir des droits supplémentaires sur cette publication, utilisez les coordonnées ci-après ou contactez le Comité national de l'IEC de votre pays de résidence IEC Central Office 3, rue de Varembé CH-1 21 Geneva 20 Switzerland Tel.: +41 22 91 02 1 Fax: +41 22 91 03 00 info@iec.ch www.iec.ch Ab ou t th e I E C The I nternational Electrotechnical Commission (I EC) is the leading global organization that prepares and publishes I nternational Standards for all electrical, electronic and related technologies Ab o u t I E C p u b l i ca ti o n s The technical content of IEC publications is kept under constant review by the IEC Please make sure that you have the latest edition, a corrigenda or an amendment might have been published I E C Catal og u e - webstore i ec ch /catal og u e The stand-alone application for consulting the entire bibliographical information on IEC International Standards, Technical Specifications, Technical Reports and other documents Available for PC, Mac OS, Android Tablets and iPad I E C pu bl i cati on s s earch - www i ec ch /search pu b The advanced search enables to find IEC publications by a variety of criteria (reference number, text, technical committee,…) It also gives information on projects, replaced and withdrawn publications E l ectroped i a - www el ectroped i a org The world's leading online dictionary of electronic and electrical terms containing more than 30 000 terms and definitions in English and French, with equivalent terms in additional languages Also known as the International Electrotechnical Vocabulary (IEV) online I E C G l os sary - s td i ec ch /g l oss ary More than 60 000 electrotechnical terminology entries in English and French extracted from the Terms and Definitions clause of IEC publications issued since 2002 Some entries have been collected from earlier publications of IEC TC 37, 77, 86 and CISPR I E C J u st Pu bl i s h ed - webstore i ec ch /j u stpu bl i sh ed Stay up to date on all new IEC publications Just Published details all new publications released Available online and also once a month by email I E C C u stom er S ervi ce C en tre - webstore i ec ch /csc If you wish to give us your feedback on this publication or need further assistance, please contact the Customer Service Centre: csc@iec.ch A propos d e l 'I E C La Commission Electrotechnique I nternationale (IEC) est la première organisation mondiale qui élabore et publie des Normes internationales pour tout ce qui a trait l'électricité, l'électronique et aux technologies apparentées A propos d es pu bl i cati on s I E C Le contenu technique des publications IEC est constamment revu Veuillez vous assurer que vous possédez l’édition la plus récente, un corrigendum ou amendement peut avoir été publié Catal og u e I E C - webstore i ec ch /catal og u e Application autonome pour consulter tous les renseignements bibliographiques sur les Normes internationales, Spécifications techniques, Rapports techniques et autres documents de l'IEC Disponible pour PC, Mac OS, tablettes Android et iPad Rech erch e d e pu bl i cati on s I E C - www i ec ch /search pu b La recherche avancée permet de trouver des publications IEC en utilisant différents critères (numéro de référence, texte, comité d’études,…) Elle donne aussi des informations sur les projets et les publications remplacées ou retirées E l ectroped i a - www el ectroped i a org Le premier dictionnaire en ligne de termes électroniques et électriques Il contient plus de 30 000 termes et dộfinitions en anglais et en franỗais, ainsi que les termes équivalents dans langues additionnelles Egalement appelé Vocabulaire Electrotechnique International (IEV) en ligne G l oss re I E C - s td i ec ch /g l ossary Plus de 60 000 entrées terminologiques électrotechniques, en anglais et en franỗais, extraites des articles Termes et Définitions des publications IEC parues depuis 2002 Plus certaines entrées antérieures extraites des publications des CE 37, 77, 86 et CISPR de l'IEC I E C J u st Pu bl i s h ed - webstore i ec ch /j u stpu bl i s h ed Restez informé sur les nouvelles publications IEC Just Published détaille les nouvelles publications parues Disponible en ligne et aussi une fois par mois par email S ervi ce Cl i en ts - webstore i ec ch /csc Si vous désirez nous donner des commentaires sur cette publication ou si vous avez des questions contactez-nous: csc@iec.ch I E C 60 4-2 ® Edition 2.0 201 5-07 I N TE RN ATI ON AL S TAN D ARD N ORM E I N TE RN ATI ON ALE F i xed capaci tors for u s e i n el ectron i c e q u i pm e n t – P art 5: S ecti on al s pe ci fi cati on – F i xed al u m i n i u m el ectrol yti c s u rface m ou n t capaci tors wi th d u cti ve pol ym er s ol i d el e ctrol yte C on d en s ateu rs fi xes u ti l i s é s d an s l e s éq u i pe m e n ts él e ctron i q u e s – P arti e 5: S pé ci fi cati on i n term é d i re – C on d en s ateu rs fi xes él ectrol yti q u es en al u m i n i u m pou r m on tag e en s u rface é l ectrol yte s ol i d e e n pol ym ère d u cte u r INTERNATIONAL ELECTROTECHNICAL COMMISSION COMMISSION ELECTROTECHNIQUE INTERNATIONALE ICS 31 060.40; 31 060.50 ISBN 978-2-8322-2790-9 Warn i n g ! M ake s u re th at you obtai n ed th i s pu bl i ca ti on from an au th ori zed d i s tri bu tor Atten ti on ! Veu i l l ez vou s ass u rer q u e vou s avez obten u cette pu bl i cati on vi a u n d i stri b u teu r ag ré é ® Registered trademark of the International Electrotechnical Commission –2– I EC 60384-25:201  I EC 201 CONTENTS FOREWORD General 1 Scope Object Norm ative references I nform ation to be given in a detail specification General Outline drawing and dimensions Mounting 4 Ratings and characteristics Marking Terms and definitions Marking General I nform ation for m arking Marking on capacitors Marking on packaging Preferred ratings and characteristics Preferred characteristics 2 Preferred values of ratings 2 Nominal capacitance ( CN ) 2 Tolerance on nom inal capacitance 2 Rated voltage ( UR ) 2 Category voltage ( UC ) 2 Surge voltage ( URS ) 2 Rated temperature Quality assessment procedures 1 Primary stage of m anufacture 1 Structurally sim ilar com ponents 1 3 Certified test records of released lots 1 Qualification approval procedures 1 General 1 Qualification approval on the basis of the fixed sample size procedure 1 Tests Quality conformance inspections Form ation of inspection lots Test schedule 20 Delayed delivery 20 Assessm ent levels 20 Test and m easurement procedures 21 Preliminary drying 21 Measuring conditions 21 Mounting 21 General 21 I nitial inspections 21 3 Test conditions 21 I EC 60384-25:201  I EC 201 –3– Final inspections and requirements 21 4 4 Visual exam ination and check of dimensions 21 4 General 21 4 Visual examination and check of dim ensions 22 4 Requirem ents 22 Electrical tests 22 Leakage current 22 Capacitance 22 Tangent of loss angle (tan δ ) 23 Equivalent series resistance (if required) 23 5 I m pedance (if required) 23 Resistance to soldering heat 24 General 24 I nitial inspections 24 Test conditions 24 Recovery 24 Final inspections and requirements 24 Solderability 24 General 24 Final inspections and requirements 24 Shear test (if required) 24 Substrate bending test (if required) 24 General 24 I nitial inspections 24 Test conditions 25 Final inspections and requirements 25 Rapid change of tem perature 25 1 General 25 I nitial inspections 25 Test conditions 25 4 Recovery 25 Final inspections and requirements 25 1 Climatic sequence 25 1 General 25 1 I nitial inspections 25 1 Dry heat 25 1 Damp heat, cyclic, Test Db, first cycle 25 1 Cold 26 1 Damp heat, cyclic, Test Db, rem aining cycles 26 1 Recovery 26 1 Final inspections and requirem ents 26 Damp heat, stead y state 26 General 26 2 I nitial inspections 26 Test conditions 26 4 Recovery 26 Final inspections and requirem ents 26 Characteristics at high and low tem perature 26 General 26 –4– I EC 60384-25:201  I EC 201 I nspections and requirem ents 27 4 Surge voltage 27 4 General 27 4 I nitial inspections 27 4 Test conditions 27 4 Recovery 27 4 Final inspections and requirements 27 Endurance 27 General 27 I nitial inspections 27 Test conditions 27 Recovery 28 5 Final inspections and requirem ents 28 Storage at high tem perature 28 General 28 I nitial inspections 28 Test conditions 28 Recovery 28 Final inspections and requirem ents 28 Charge and discharge (if required) 28 General 28 I nitial inspections 28 Test conditions 28 Final inspections and requirem ents 29 Component solvent resistance (if required) 29 Solvent resistance of marking (if required) 29 20 High surge current (if required) 29 20 General 29 20 Final inspections and requirem ents 29 Bibliograph y 30 Table Table Table Table Table – Surge voltages – Sampling plan for qualification approval, assessm ent level EZ – Test schedule for qualification approval (1 of 6) – Lot-by-lot inspection 20 – Periodic inspection 21 I EC 60384-25:201  I EC 201 –5– INTERNATI ONAL ELECTROTECHNI CAL COMMISSI ON F I XE D C AP AC I T O RS F O R U S E I N E L E C T RO N I C E Q U I P M E N T – P a rt : S e c ti o n a l s p e c i fi c a ti o n – F i xe d a l u m i n i u m e l e c tro l yt i c s u rfa c e m o u n t c a p a c i t o rs wi th c o n d u c ti ve p o l ym e r s o l i d e l e c t ro l yt e FOREWORD ) The I nternati on al Electrotechni cal Comm ission (I EC) is a worl d wid e organization for stan dardization com prisin g all n ation al el ectrotechnical comm ittees (I EC National Comm ittees) The object of I EC is to prom ote internati onal co-operation on all questions concerni ng stand ardi zati on in the el ectrical an d electronic fields To this end and in additi on to other acti vities, I EC publish es I nternational Stan dards, Techn ical Specifications, Technical Reports, Publicl y Avail abl e Specificati ons (PAS) an d Gu ides (h ereafter referred to as “I EC Publication(s)”) Thei r preparation is entrusted to technical comm ittees; any I EC National Comm ittee interested in the subj ect dealt with m ay partici pate in this preparatory work I nternational, governm ental an d n on governm ental organ izations l iaising with th e I EC also participate i n this preparation I EC collaborates closel y with the I ntern ational Organi zation for Stand ardization (I SO) in accordance with ditions determ ined by agreem ent between th e two organi zati ons 2) The form al decisions or ag reem ents of I EC on tech nical m atters express, as n early as possible, an i nternati onal consensus of opi nion on the rel evant subjects since each technical com m ittee has representati on from all interested I EC N ational Com m ittees 3) I EC Publications have the form of recomm endations for intern ational use an d are accepted by I EC National Com m ittees in that sense While all reasonable efforts are m ade to ensure that th e technical content of I EC Publications is accu rate, I EC cann ot be h eld responsi ble for th e way in which th ey are used or for an y m isinterpretation by an y en d u ser 4) I n order to prom ote intern ational u niform ity, I EC National Com m ittees und ertake to apply I EC Publications transparentl y to the m axim um extent possible i n their national an d regi on al publicati ons Any d ivergence between an y I EC Publication and the correspondi ng national or regi on al publicati on sh all be clearl y in dicated in the latter 5) I EC itself d oes n ot provi de an y attestation of conform ity I n depend ent certificati on bodies provi de conform ity assessm ent services and, in som e areas, access to I EC m arks of conform ity I EC is not responsi ble for any services carri ed out by ind ependent certification bodi es 6) All users shou ld ensure that th ey have the l atest editi on of thi s publicati on 7) No liability shall attach to I EC or its directors, em ployees, servants or ag ents inclu din g in divi dual experts an d m em bers of its technical com m ittees and I EC Nati on al Com m ittees for any person al i njury, property d am age or other dam age of any nature whatsoever, wheth er di rect or indirect, or for costs (includ i ng leg al fees) and expenses arisi ng out of the publ ication, use of, or relian ce upon, this I EC Publicati on or any other I EC Publications 8) Attention is drawn to th e N orm ative references cited in th is publ ication Use of the referenced publ ications is indispensable for the correct applicati on of this publication 9) Attention is drawn to the possibility that som e of the elem ents of this I EC Publication m ay be the su bject of patent rig hts I EC shall not be held responsibl e for identifyi ng any or all such patent ri ghts I nternational Standard I EC 60384-25 has been prepared by I EC technical comm ittee 40: Capacitors and resistors for electronic equipm ent This second edition cancels and replaces the first edition published in 2006 and constitutes a technical revision This edition includes the following significant technical changes with respect to the previous edition: a) Revision of the structure in accordance with I SO/I EC Directives, Part 2: 201 (sixth edition) to the extent practicable, and harmonization between other similar kinds of documents b) I n addition, Clause and all the tables have been reviewed in order to prevent duplications and contradictions –6– I EC 60384-25:201  I EC 201 The text of this standard is based on the following documents: FDI S Report on votin g 40/2383/FDI S 40/2396/RVD Full information on the voting for the approval of this standard can be found in the report on voting indicated in the above table This publication has been drafted in accordance with the I SO/I EC Directives, Part The list of all parts of the I EC 60384 series, under the general title Fixed capacitors for use in electronic equipment, can be found on the I EC website The comm ittee has decided that the contents of this publication will remain unchanged until the stability date indicated on the I EC website under "http: //webstore.iec.ch" in the data related to the specific publication At this date, the publication will be • • • • reconfirmed, withdrawn, replaced by a revised edition, or am ended I EC 60384-25:201  I EC 201 –7– F I XE D C AP AC I T O RS F O R U S E I N E L E C T RO N I C E Q U I P M E N T – P a rt : S e c ti o n a l s p e c i fi c a ti o n – F i xe d a l u m i n i u m e l e c tro l yt i c s u rfa c e m o u n t c a p a c i t o rs w i th c o n d u c ti ve p o l ym e r s o l i d e l e c t ro l yt e G e n e l 1 S co p e This part of I EC 60384 applies to fixed aluminium electrol ytic surface m ount capacitors with conductive pol ym er solid electrolyte, prim aril y intended for d c applications for use in electronic equipment Fixed alum inium electrolytic surface mount capacitors with solid (MnO ) are not included but are covered by I EC 60384-1 These capacitors are primaril y intended for use in electronic equipment to be mounted directl y on substrates for h ybrid circuits or to printed boards Capacitors for special-purpose applications m ay need additional requirements O b j ect The obj ect of this standard is to prescribe preferred ratings and characteristics and to select from I EC 60384-1 , the appropriate quality assessment procedures, tests and m easuring methods and to give general performance requirements for this type of capacitor Test severities and requirements prescribed in detail specifications referring to this sectional specification shall be of equal or higher performance level, because lower performance levels are not permitted N o rm a t i v e re fe re n c e s The following docum ents, in whole or in part, are norm ativel y referenced in this docum ent and are indispensable for its application For dated references, onl y the edition cited applies For undated references, the latest edition of the referenced document (including an y amendments) applies I EC 60063, Preferred number series for resistors and capacitors I EC 60068-1 : 201 3, Environmental testing – Part : General and guidance I EC 60384-1 : 2008, Fixed capacitors for use in electronic equipment – Part : Generic specification I EC 61 93-2: 2007, Quality assessment systems – Part 2: Selection and use of sampling plans for inspection of electronic components and packages I SO 3, Preferred numbers – Series of preferred numbers I n fo rm a t i o n to b e g i ven in a d etai l s p e c i fi c a t i o n G e n e l Detail specifications shall be derived from the blank detail specification –8– I EC 60384-25:201  I EC 201 Detail specifications shall not specify requirem ents inferior to those of the generic, sectional or blank detail specification When m ore severe requirem ents are included, they shall be listed in of the detail specification and indicated in the test schedules, for example, by an asterisk The inform ation given in m ay, for convenience, be presented in tabular form The following inform ation shall be given in each detail specification and the values quoted shall preferabl y be selected from those given in the appropriate clause of this sectional specification Ou tli n e d rawin g an d d i m en sion s There shall be an illustration of the capacitors as an aid to easy recognition and for comparison of the capacitors with others Dim ensions and their associated tolerances, which affect interchangeability and m ounting, shall be given in the detail specification All dimensions shall preferabl y be stated in m illim etres; however, when the original dimensions are given in inches, the converted m etric dimensions in millimetres shall be added The numerical values of the bod y shall be given as follows: – for general: – for cylindrical bod y: the width, length and height the diameter and length The num erical values of the term inals shall be given as follows: – for terminals: the width, length and spacing When the configuration is other than described above, the detail specification shall state such dimensional information as will adequatel y describe the capacitors M ou n tin g The m ethod of m ounting for tests and m easurements are given in The detail specification shall specify the m ethods of mounting for norm al use 4 Rati n g s an d ch aracteri sti cs 4.1 Gen eral The ratings and characteristics shall be given in accordance with the relevant clauses of this specification, with the following 4.2 N om in al capacitan ce ran g e See 2 When products approved to the detail specification have different nom inal capacitance ranges, the following statement should be added: “The nom inal capacitance range available in each voltage range is given in the register of approvals, available for example on the I ECQ on-line certificate system website www iecq org” 4 Parti cu l ar ch aracteri sti cs Additional characteristics m ay be listed when they are considered necessary to specify adequatel y the component for design and application purposes – 48 – Tableau Numéro de parag raph e et essai a , élémen ts soumis au contrôle Charg e et décharg e e Contrôl es initiau x Capacité Contrôl es finau x Exam en visu el D ou ND b D  I EC 201 (5 de 6) Conditions d’ essai mesures Voir I EC 60384-25: 201 a et Nombre admissible de spécimen s ( n ) et nombre d’ éléments non conformes ( c ) Exigences de performances a Voir Tableau Voir 2 Voir 4 Aucun dom m age visibl e Marq uag e lisibl e Cou rant de fuite Voir Capacité Voir 2 ≤ lim ite initiale | ∆ C/C| ≤ 20 % d e la Voir ≤ , fois la lim ite initial e Voir ≤ fois la lim ite initial e Tang ente de l'ang le de perte Résistance série équi valente GROUPE 3.4 Endu rance Contrôl es initiau x Capacité Rétablissem ent 5 Contrôl es finau x Exam en visu el D Voir val eu r m esurée en Voir Tableau Voir 2 Voir Voir 4 Aucun dom m age visibl e Marq uag e lisibl e Cou rant de fuite Voir Capacité Voir 2 ≤ fois la lim ite initial e | ∆ C/C| ≤ 20 % d e la Tang ente de l'ang le de perte Résistance série équi valente Voir ≤ , fois la lim ite initiale Voir ≤ fois la lim ite initial e val eu r m esurée en I EC 60384-25:201  I EC 201 – 49 – Tabl e au N u m é ro d e p a g p h e e t a ess , é l é m e n ts au sou m i s D ou ND (6 de 6) C o n d i ti o n s d ’ e s s a i b m e s u re s a et s p éci m en s ( c o n t rô l e E xi g e n c e s d e N o m b re ad m i ssi bl e d e p e rfo rm a n c e s a n) e t n o m b re d ’ él ém en ts n on c o n fo rm e s ( G RO U P E D Stockage h aute tem pératu re Contrôl es initiaux Capacité Rétablissem ent Contrôl es finau x Exam en visu el Voir c) Voir Tableau Voir 2 Voir Voir 4 Aucun dom m age visibl e Marq uag e lisibl e ≤ fois la lim ite initial e Cou rant de fuite Voir Capacité Voir 2 | ∆ C/C| ≤ % d e la val eu r m esurée en Voir ≤ lim ite initiale Tang ente de l'ang le de perte 4 Surtensi on 4 Contrôl es initiaux Capacité 4 Rétablissem ent 4 Contrôl es finau x Exam en visu el Cou rant de fuite Voir 4 Voir 2 Voir 4 Voir 4 Voir Capacité Voir 2 Tang ente de l'ang le de perte Voir Aucun dom m age visibl e ≤ lim ite initiale | ∆ C/C| ≤ % d e la val eu r m esurée en 4 ≤ , fois la lim ite initiale a Les num éros d es parag raph es des essais et des exig ences d e perform ances font référence l’Article b Dans ce tableau: D = d estructif, ND = non d estructif c Cet essai peut être effectu é su r des densateu rs pour m ontage en surface m ontés sur un substrat d CN est la capacité nom inal e en m icrofarads; UR est la tension assignée en volts e Le cas échéant C o n t rô l e s d e c o n fo rm i t é d e l a q u a l i t é 5 F o rm a t i o n d e s l o t s d e c o n t rô l e I n s p e cti o n d e s G ro u p e s A et B Ces essais doivent être effectués lot par lot Un fabricant peut répartir la production actuelle en lots de contrôle soumis aux m oyens de protection suivants: a) Le lot de contrôle doit être constitué de condensateurs de structure sim ilaire (voir 3.2) b) L’échantillon soum is aux essais doit être représentatif des valeurs (tension assignée et capacité nom inale) et des dim ensions présentes dans le lot de contrôle: – en fonction de leur nom bre; – 50 –  I EC 201 I EC 60384-25: 201 – avec un minimum de cinq valeurs c) Si l’échantillon contient m oins de cinq valeurs, le prélèvem ent des échantillons doit faire l’obj et d’un accord avec le fabricant et l’organism e de certification I n s p e c t i o n s d u G ro u p e C Ces essais doivent être effectués périodiquem ent Les échantillons doivent être représentatifs de la production actuelle pour les périodes spécifiées et doivent être divisés en plages de hautes, m oyennes et basses tensions Pour couvrir la gamme d’approbation sur n’im porte quelle période, une taille de btier doit être soum ise aux essais dans chaque groupe de tensions Pour les périodes suivantes, les essais doivent porter sur d’autres tailles de btier et/ou d'autres valeurs assignées de tension en production pour couvrir toute la gamm e P ro g m m e d ’ e s s a i s Le programm e d’essais pour les essais lot par lot et pour les essais périodiques pour le contrôle de conform ité de la qualité est indiqué dans la spécification particulière-cadre L i v i s o n d i ffé ré e Si, conform ém ent aux procédures de l'I EC 60384-1 : 2008, Q 0, il convient qu’un autre contrôle soit effectué La capacité, la tangente de l ’angle de perte, le courant de fuite et la brasabilité doivent être contrôlés comm e cela est spécifié dans le contrôle des Groupes A et B N i v e a u x d ’ a s s u n c e Les niveaux d’assurance donnés dans la spécification particulière-cadre doivent de préférence être sélectionnés depuis les Tableau et Tableau Tabl e au S o u s - g ro u p e d e c o n t rô l e a NC – I n s p e cti on b l ot par l ot n b c b %c A0 00 A1 S–3 d S–3 d S–3 d A2 B1 a Le contenu du sous-grou pe d e contrôl e est décrit l’Articl e de la spécification particulière-cadre b NC est le n iveau de contrôl e n est la taille d'échantillons c est le nom bre adm issible d’él ém ents non conform es c Après le retrait d es élém ents non conform es par un essai 00 % pendant le processus de fabricati on, le contrôl e par éch antill onn ag e doit être effectué afin de contrôler l e ni veau de qu alité après contrôl e par élém ents non conform es par m illion ( × –6 ) Le n iveau d’échantil lon nage d oit être d éfini par le fabricant, d e préférence sel on l'I EC 61 93-2: 2007, Ann exe A Dans le cas où u n échantillon com porte un ou pl usieu rs élém ents non conform es, le lot doit être rejeté, m ais la totalité de l 'échantill on d oit être i nspectée et tous les élém ents non conform es doivent être com ptés pour calculer l es val eu rs du niveau de qu alité Les valeurs d u niveau d e q ual ité après contrôle par él ém ents non conform es par m illion ( × –6 ) d oivent être calcul ées en accum ulant les don nées de contrôl e selon la m éthod e donn ée en de l'I EC 61 93-2: 2007 d Nom bre soum ettre au x essais: la tai ll e d'éch antill ons doit être d éterm inée conform ém ent l'I EC 61 93-2: 2007, I EC 60384-25:201  I EC 201 – 51 – Tabl eau – I n s p e cti on p é ri o d i q u e EZ S o u s - g ro u p e d e pb nb cb C1 12 C2 12 C3 12 C3 24 C3 3A 12 C3 3B 12 C3 36 C3 12 c o n t rô l e a b Le contenu du sous-grou pe d e contrôl e est décrit l’Articl e de la spécification particulière-cadre p n c a est la péri odicité en m ois est la taille d'échantillons est le nom bre adm issible d’él ém ents non conform es P ro c é d u re s d ’ e s s a i s e t d e m e s u re s L'Article com plète les informations de l’Article de l'I EC 60384-1 : 2008 S é c h a g e p ré l i m i n a i re Voir l'I EC 60384-1 : 2008, 4 C o n d i t i o n s d e m e s u re Voir l'I EC 60384-1 : 2008, 4 M o n ta g e G é n é l i t é s Voir l'I EC 60384-1 : 2008, 33, avec les détails suivants C o n t rô l e s i n i t i a u x Voir Tableau C o n d i ti o n s d ’ e s s a i La méthode d'essai doit être la méthode de refusion et le profil de tem pérature de la refusion doit être spécifié dans la spécification particulière E x i g e n c e s e t c o n t rô l e s fi n a u x Voir Tableau 4 4 E xa m e n v i s u e l e t c o n t rô l e d e s d i m e n s i o n s G é n é l i t é s Voir l'I EC 60384-1 : 2008, 4, avec les détails suivants – 52 – 4.4.2 I EC 60384-25: 201  I EC 201 Examen visuel et contrôle des dimensions L’équipem ent utilisé pour l’examen visuel doit être approprié avec un grossissement d’environ × et un éclairage approprié du spécim en soumis aux essais et le niveau de qualité exigé I l convient que l’opérateur dispose d’équipements pour l’éclairage incident ou transmis ainsi que d’équipements de m esure appropriés Les condensateurs doivent être examinés pour vérifier que les m atériaux, le design, la fabrication et les dimensions ph ysiques sont appropriées 4.4.3 Exigences La m ain d’œuvre doit être conform e aux exigences applicables données dans la spécification particulière 4.5 Essais électriques 4.5.1 4.5.1 Cou rant de fuite Généralités Voir l'I EC 60384-1 : 2008, 9, avec les détails suivants 4.5.1 Préconditionnement I l convient que le condensateur soit relié en série une résistance de protection dans la plage de Ω 000 Ω et il convient d'appliquer une tension continue équivalente la tension assignée pendant h 05 °C ± °C La tension appliquée aux bornes des condensateurs doit être m aintenue entre ± % de la tension nominale Ensuite, lorsque le condensateur est refroidi la tem pérature ambiante, il convient de le décharger dans une résistance d’environ Ω /V, puis de le stocker dans des conditions atmosphériques normalisées pendant h 24 h 4.5.1 Conditions de mesure La tension assignée doit être appliquée aux bornes du condensateur et de sa résistance de protection placée en série avec le condensateur pour limiter le courant de charge La valeur de la résistance de protection doit être 000 Ω Il convient que la mesure de chaque essai soit réalisée après le préconditionnem ent 4.5.1 Exigences Voir Tableau 4.5.2 4.5.2.1 Capacité Généralités Voir l'I EC 60384-1 : 2008, 7, avec les détails suivants 4.5.2.2 Conditions de mesure Sauf indication contraire dans les spécifications particulières, la capacité doit être mesurée une fréquence de 20 H z La tension alternative de crête réellement appliquée aux bornes des sorties du condensateur ne doit pas dépasser 0, V efficace en courant alternatif I EC 60384-25:201  I EC 201 – 53 – Une tension de polarisation continue de 0, V , V peut être appliquée pendant la m esure, afin d’éviter l'application d'une tension négative sur le condensateur par la tension alternative appliquée L’imprécision des instrum ents de mesure ne doit pas d épasser ± % de la limite indiquée dans la spécification particulière, qu’il s'agisse d’une valeur absolue ou d’une variation de capacité E xi g e n c e s Voir Tableau T a n g e n t e d e l ’ a n g l e d e p e rt e ( t a n δ ) G é n é l i t é s Voir l'I EC 60384-1 : 2008, , avec les détails suivants C o n d i t i o n s d e m e s u re La mesure doit être faite en respectant les conditions de L’im précision de l’équipement de m esure ne doit pas dépasser % de la valeur absolue E xi g e n c e s Voir Tableau 4 R é s i s t a n c e s é ri e é q u i v a l e n t e ( s i n é c e s s a i re ) G é n é l i t é s Voir l'I EC 60384-1 : 2008, 2, avec les détails suivants C o n d i t i o n s d e m e s u re Sauf indication contraire dans les spécifications particulières, les conditions d’essai sont les suivantes: – Tem pérature: 20 °C ± °C; – Tension appliquée: valeur alternative de crête ≤ 0, V efficace; – fréquence de la tension: 00 kH z L’erreur de m esure ne doit pas dépasser la plus grande valeur parm i % des exigences et 0, 02 Ω E xi g e n c e s Voir Tableau 5 5 I m p éd an ce ( s i n é c e s s a i re ) G é n é l i t é s Voir l'I EC 60384-1 : 2008, 0, avec les détails suivants 5 C o n d i t i o n s d e m e s u re La fréquence de mesure: 20 H z ± % – 54 – I EC 60384-25: 201  I EC 201 I l convient que la tension de mesure soit suffisamment basse, et il convient que la variation de la valeur d’im pédance se situe dans la plage d’erreurs de m esure lorsque la tension est appliquée aux condensateurs pendant m inute L’erreur de m esure ne doit pas dépasser la plus grande valeur parmi 0, 02 Ω 4.5.5.3 ± % des exigences et Exigences Voir Tableau 4.6 4.6.1 Résistance la chaleu r de brasage Généralités Voir l'I EC 60384-1 : 2008, 4, avec les détails suivants 4.6.2 Contrôles initiau x Voir Tableau 4.6.3 Conditions d’essai La méthode d'essai doit être la méthode de refusion et le profil de température de la refusion doit être spécifié dans la spécification particulière 4.6.4 Rétablissement La période de rétablissem ent doit être de 24 h 4.6.5 ± h Exigences et contrôles finaux Après rétablissem ent, les condensateurs pour montage en surface doivent être soumis un exam en visuel sous un éclairage normal et avec un grossissem ent d’environ × et les caractéristiques électriques mesurées données au Tableau 4.7 4.7.1 Brasabilité Généralités Voir l'I EC 60384-1 : 2008, 5, avec les détails suivants 4.7.2 Exigences et contrôles finaux Voir Tableau 4.8 Essai de cisaillement (si nécessaire) Voir l'I EC 60384-1 : 2008, 34 4.9 4.9.1 Essai de courbure du substrat (si nécessaire) Généralités Voir l'I EC 60384-1 : 2008, 35, avec les détails suivants 4.9.2 Contrôles initiaux Voir Tableau I EC 60384-25:201 4.9.3  I EC 201 – 55 – Conditions d’essai La flèche D et le nombre de courbures doivent être spécifiés dans la spécification particulière 4.9.4 Exigences et contrôles finaux Voir Tableau 4.1 Variations rapides de températu re 4.1 0.1 Généralités Voir l'I EC 60384-1 : 2008, 6, avec les détails suivants: Les condensateurs doivent être m on tés conformément 4.1 0.2 Contrôles initiaux Voir Tableau 4.1 0.3 Conditions d’essai Les conditions d’essai sont les suivantes: – – – – TA est la tem pérature de catégorie inférieure; TB est la tem pérature de catégorie supérieure; les condensateurs doivent être soum is cycles d'essais; la durée d’exposition chaque limite de température doit être de 30 m in 4.1 0.4 Rétablissement La période de rétablissement doit être comprise entre h et h 4.1 0.5 Exigences et contrôles finaux Voir Tableau 4.1 Séqu ence climatique 4.1 1 Généralités Voir l'I EC 60384-1 : 2008, 21 , avec les détails suivants: 4.1 Contrôles initiaux Voir Tableau 4.1 Chaleu r sèche Voir l'I EC 60384-1 : 2008, 21 2, avec les détails suivants: – Température: – Durée: 4.1 tem pérature de catégorie supérieure; h Chaleur humide, cyclique, essai Db, premier cycle Voir l'I EC 60384-1 : 2008, 21 – 56 – 4.1 I EC 60384-25: 201 Froid Voir l'I EC 60384-1 : 2008, 21 4, avec les détails suivants: – Température: – Durée: 4.1 température de catégorie inférieure; h Chaleu r humide, cyclique, essai Db, cycles restants Voir l'I EC 60384-1 : 2008, 21 4.1 Rétablissement La période de rétablissement doit être com prise entre h et h 4.1 Exigences et contrôles finaux Voir Tableau 4.1 Chaleur humide, essai continu 4.1 2.1 Généralités Voir l'I EC 60384-1 : 2008, 22, avec les détails suivants: Les condensateurs doivent être montés conform ém ent 4.1 2.2 Contrôles initiau x Voir Tableau 4.1 2.3 Conditions d’essai Les conditions d’essai sont les suivantes: – – – – Température: Humidité relative: Tension appliquée: Durée: 4.1 2.4 40 °C ± °C; (93 ± 3) %; Aucune tension ne doit être appliquée; 21 jours Rétablissement La période de rétablissement doit être com prise entre h et h 4.1 2.5 Exigences et contrôles finaux Voir Tableau 4.1 Caractéristiques haute et basse températu re 4.1 3.1 Généralités Voir l'I EC 60384-1 : 2008, 29, avec les détails suivants: Les condensateurs doivent être montés conform ém ent  I EC 201 I EC 60384-25:201  I EC 201 – 57 – I n s p e c t i o n s e t e xi g e n c e s Les condensateurs doivent être mesurés chaq ue échelon de tem pérature et doivent satisfaire aux exigences du Tableau 4 4 S u rt e n s i o n G é n é l i t é s Voir l'I EC 60384-1 : 2008, 26, avec les détails suivants: 4 C o n t rô l e s i n i t i a u x Voir Tableau 4 C o n d i ti o n s d ’ e s s a i Les conditions d’essai sont les suivantes: – Nom bre de cycles: – Température: 000; °C la température de catégorie supérieure avec les exigences applicables données dans la spécification particulière; – Tension: , UR ou ,1 UC ; – Résistance de protection: 000 Ω ± 00 Ω ou une valeur calculée par la formule (1 ); RC = 0, s ± 0,05 s où R est la valeur de la résistance de charge C est la valeur de la capacité nom inale – Durée de charge: – Durée vide: 4 30 s; m in 30 s Ré t a b l i s s e m e n t La période de rétablissement doit être comprise entre h et h 4 E x i g e n c e s e t c o n t rô l e s fi n a u x Voir Tableau 5 E n d u n c e G é n é l i t é s Voir l'I EC 60384-1 : 2008, 23, avec les détails suivants: Les condensateurs doivent être montés conform ém ent 4 C o n t rô l e s i n i t i a u x Voir Tableau C o n d i ti o n s d ’ e s s a i Les conditions d’essai sont les suivantes: (1 ) – 58 – – Tension appliquée: – Tem pérature: – Durée: 4.1 5.4 I EC 60384-25: 201  I EC 201 tension assignée, sauf indication contraire dans la spécification particulière; température de catégorie supérieure; 000 h Rétablissement La période de rétablissem ent doit être comprise entre h et h 4.1 5.5 Exigences et contrôles finaux Voir Tableau 4.1 Stockage haute température 4.1 6.1 Généralités Voir l'I EC 60384-1 : 2008, 25 , avec les détails suivants 4.1 6.2 Contrôles initiaux Voir Tableau 4.1 6.3 Conditions d’essai Les conditions d’essai sont les suivantes: – Tem pérature: – Durée: 4.1 6.4 tem pérature de catégorie supérieure; 96 h ± h Rétablissement La période de rétablissem ent m inimale doit être de h 4.1 6.5 Exigences et contrôles finaux Voir Tableau 4.1 Charge et décharge (si nécessaire) 4.1 7.1 Généralités Voir l'I EC 60384-1 : 2008, 27, avec les détails suivants 4.1 7.2 Contrôles initiaux Voir Tableau 4.1 7.3 Conditions d’essai La charge et la décharge doivent être effectuées jusqu'au nombre de cycles spécifié la tem pérature indiquée dans la spécification particulière (dans la plage de températures am biantes allant de °C la température de catégorie supérieure) Les condensateurs doivent être soum is au nombre spécifié de cycles, chaque cycle étant constitué d'une charge selon a) suivi d'une décharge selon b) a) Charge: – Tension appliquée: tension continue assignée; I EC 60384-25:201  I EC 201 – 59 – – Résistance interne de la source de tension plus résistance série externe: selon les exigences pour RC = 0, s; – Durée: 0,5 s; – Nom bre de cycles: b) Décharge: – Pas de tension appliquée; – Résistance de décharge: selon les exigences pour RC = 0, s; – Durée: 0,5 s; – Nom bre de cycles: 4.1 7.4 Exigences et contrôles finaux Voir Tableau 4.1 Résistance au solvant des composants (si nécessaire) Voir l'I EC 60384-1 : 2008, 31 4.1 Résistance au solvant du marquage (si nécessaire) Voir l'I EC 60384-1 : 2008, 32 4.20 Surintensité élevée (si nécessaire) 4.20.1 Généralités Voir l'I EC 60384-1 : 2008, 39, avec les détails suivants 4.20.2 Exigences et contrôles finaux Voir Tableau – 60 – I EC 60384-25: 201  I EC 201 Bibliographie I EC 60068-2-58: 2004, Essais d'environnement – Partie 2-58: Essais – Essai Td: Méthodes d’essai de la soudabilité, résistance de la métallisation la dissolution et résistance la chaleur de brasage des composants pour montage en surface (CMS) IEC 60384-1 8, Condensateurs fixes utilisés dans les équipements électroniques – Partie 8: Spécification intermédiaire – Condensateurs fixes électrolytiques l'aluminium pour montage en surface électrolyte solide (MnO2) et non solide _ I N TE RN ATI O N AL E LE CTRO TE CH N I CAL CO M M I S S I O N 3, ru e d e Va re m bé P O B ox CH -1 1 G e n e va S wi tze rl a n d Te l : + 41 F a x: + 22 91 02 1 22 91 03 00 i n fo @i e c ch www i e c ch

Ngày đăng: 17/04/2023, 10:34

TÀI LIỆU CÙNG NGƯỜI DÙNG

TÀI LIỆU LIÊN QUAN