1. Trang chủ
  2. » Thể loại khác

Lua chon day dan can thiep mach vanh

42 231 2

Đang tải... (xem toàn văn)

Tài liệu hạn chế xem trước, để xem đầy đủ mời bạn chọn Tải xuống

THÔNG TIN TÀI LIỆU

Thông tin cơ bản

Định dạng
Số trang 42
Dung lượng 3,39 MB

Nội dung

Lua chon day dan can thiep mach vanh tài liệu, giáo án, bài giảng , luận văn, luận án, đồ án, bài tập lớn về tất cả các...

LỰA CHỌN CATHETER VÀ DÂY DẪN CAN THIỆP MẠCH VÀNH (Guiding & wire selection) TS Nguyễn Cửu Lợi Trung tâm Tim mạch BV Trung Ương Huế Roles of guiding catheter & guidewire Guiding catheter: Injection of contrast & medication Delivery of devices Guidewire: Crossing the lesions Requirements: Stablization Support Specific to lesions GUIDING CATHETER Guiding catheter selection Variables Requirements - Asc Aorta size - Location of ostia - Vessel course - Enough accomodation - Coaxial intubation - Adequate support = backup Inner diameter Smaller as possible Enough large Minimize vesel trauma Accommodate devices Combined profile of balloons + 0.006” Left main lesions Risk of occlusion and dissection Coaxial Ostium lesion: no backup Small and short-tip Judkins left Guiding catheter for LAD lesions No backup & Normal take-off Guiding catheter for LAD lesions with backup Guiding catheter for LAD lesions from right radial artery Guiding catheter for LCx lesions Short LM No-acute bifurcation LAD Judkins left Long LM Acute bifurcation backup Some conflicts High torque control Increased torque control Steerability ↔ Less supportive Support Straighten vessel Less steerable ↔ More flexibility Concrete cases LAD: less tortuous lesions Transition point between flexible tip and more rigid body is not a major problem Preshaped curve or tiny curve LCx: Broad curve (enter LCx) and shorter curve (cross lesion) Gradual transition would help RCA: - Normal origin: conventional soft wire with good steerability - Anterior arising: improved tip transition, placed as distally as possible Chronic total occlusion • Increased stiffness & excelent torque control, tiny curve (distal force applied to the wire tip = 3g) • “Resort”: Asahi (Intecc, Japan) Miracle series (3-12g), Conquest and Conquest Pro (tapered tip # 0.009 in / 9g), Cross-it XT series (tapered tip # 10 in./ 3-20g) • Last “terminator” - Hydrophylic-coated: : Whisper, Pilot series (Abbott), Crosswire (Terumo), Shinobi / Plus (Cordis) SOME SPECIAL GUIDEWIRES SOME SPECIAL GUIDEWIRES Crossing stent strut into side branch • Friction by the stent strut, prolapse of wire into the main branch • Greater tip strength • First: Universal or available wire • Then: Rinato/Prowater (Asahi) , Intermediate • Finally: fix-wire balloon (ACE balloon-Boston Scient.) Lesions with heavy calcification • Firstly: Universal • Then: Floppy hydrophylic (Whisper, Pilot 50/Abbott, Choice PT/Boston, Fielder/Asahi with over-the-wire balloon • With rotablator: Rotawire (floppy or extra-support) • “Buddy” wire (supportive): to advance the stent Iron Man (Abbott) • Occasionally: Wiggle (Abbott) with “zig-zag” bends 6cm from the tip Rotawire In, or beyond, a very tortuous or angulated segment • • • • • • # Calcified lesions Hydrophylic wires: Whisper (Abbott) Buddy wire or even a buddy balloon Wiggle wire Stabilizing catheter: Buddy wire in another vessel Last resort: Deflectable tip wire (Steer-it / Cordis, Venture / St Jude) Wire-tip curve Presentations of guidewire Presentations of guidewire CONCLUSIONS • Guiding catheter selection: Anatomy of ascending aorta Coronary ostia and vessel course Size - Support • Guidewire selection: Lesion characteristics Tactile experience Thanks for your attention

Ngày đăng: 09/12/2017, 09:57

TỪ KHÓA LIÊN QUAN

TÀI LIỆU CÙNG NGƯỜI DÙNG

TÀI LIỆU LIÊN QUAN

w