Nội dung

17 LUẬT DỰ ÁN: XÂY DƯNG ĐƯỜNG NỐI ĐẠI HỌC LUẬT / Content... Our SpeedStar LED luminaire addresses these fundamental issues and provides a solution to reduce the impact on our environment

Trang 1

DỰ ÁN: XÂY DƯNG ĐƯỜNG NỐI ĐẠI HỌC LUẬT

DỰ ÁN: XÂY DƯNG ĐƯỜNG NỐI ĐẠI HỌC LUẬT

Philips - BGP322 T35 1xECO106-3S/657 DC (1xECO106-3S/657) 2

Street 1: Alternative 1

Planning results 4

Street 1: Alternative 1 / Sidewalk 1 (P4)

Isolines 6

Street 1: Alternative 1 / Roadway 3 (M4)

Isolines 7

Street 1: Alternative 1 / Roadway 2 (M4)

Isolines 12

Street 1: Alternative 1 / Sidewalk 2 (P4)

Isolines 17 LUẬT

DỰ ÁN: XÂY DƯNG ĐƯỜNG NỐI ĐẠI HỌC LUẬT / Content

Trang 2

Philips BGP322 T35 1xECO106-3S/657 DC 1xECO106-3S/657

Light output ratio: 95.69%

Lamp luminous flux: 11100 lm

Luminaire luminous flux: 10622 lm

Power: 90.0 W

Luminous efficacy: 118.0 lm/W

Luminous emittance 1 / Polar LDC

200

300

400

500

600

C0 - C180 C90 - C270

45°

60°

75°

90°

105°

105°

90°

75°

60°

45°

SpeedStar – LEDs ensure a safe journey home Municipalities are under pressure to meet energy conservation goals by reducing their energy consumption and carbon footprint while complying with lighting norms and standards

Our SpeedStar LED luminaire addresses these fundamental issues and provides a solution to reduce the impact on our environment

SpeedStar is an energy-efficient luminaire requiring minimal maintenance and incorporating the easy-to-upgrade LEDGINE, which can be connected to lighting regulation systems for further energy savings This carbon-neutral luminaire is the ideal solution for functional road and street lighting

LUẬT

Philips BGP322 T35 1xECO106-3S/657 DC 1xECO106-3S/657 / Philips - BGP322 T35 1xECO106-3S/657 DC (1xECO106-3S/657)

Trang 3

Luminous emittance 1 / Linear LDC

80

160

240

320

400

C0 - C180 C90 - C270

Luminous emittance 1 / Luminance diagram

80000 120000 160000 200000 240000

g = 65.0° g = 75.0° g = 85.0°

cd/m²

C90

C135 C180

C225

C270

C315

LUẬT

Philips BGP322 T35 1xECO106-3S/657 DC 1xECO106-3S/657 / Philips - BGP322 T35 1xECO106-3S/657 DC (1xECO106-3S/657)

Trang 4

Street 1 according to EN 13201:2015

Sidewalk 2 (P4), 150.00 m²

Roadway 2 (M4), 337.50 m² Tarmac: CIE R3, q0: 0.070

Sidewalk 2 (P4), 150.00 m²

Roadway 2 (M4), 337.50 m² Tarmac: CIE R3, q0: 0.070 Median 1

Sidewalk 2 (P4), 150.00 m²

Roadway 2 (M4), 337.50 m² Tarmac: CIE R3, q0: 0.070 Median 1

Roadway 3 (M4), 337.50 m² Tarmac: CIE R3, q0: 0.070

Sidewalk 2 (P4), 150.00 m²

Roadway 2 (M4), 337.50 m² Tarmac: CIE R3, q0: 0.070 Median 1

Roadway 3 (M4), 337.50 m² Tarmac: CIE R3, q0: 0.070 Sidewalk 1 (P4), 150.00 m²

30.00 m

5.00 m

11.25 m

2.50 m

11.25 m

5.00 m

Philips BGP322 T35 1xECO106-3S/657 DC

The pole distance of this luminaire arrangement determines the length of the valuation fields.

Luminous flux (luminaire): 10621.66 lm Luminous flux (lamp): 11100.00 lm Operating Hours

Boom inclination (3): 5.0°

Light centre height (1): 12.000 m

Maximum luminous intensities

Luminous intensity class: G*3 Any direction forming the specified angle from the downward vertical, with the luminaire installed for use

* Luminous intensity values in [cd/klm] for calculating luminous intensity class refer to the output flux of the luminaire, according

EN 13201:2015

Arrangement complies with glare index class D.4

LUẬT

Street 1: Alternative 1 / Planning results

Trang 5

Results for valuation fields

Light loss factor: 0.90

Sidewalk 1 (P4)

Em [lx]

≥ 8.00

≤ 12.00

Emin [lx]

≥ 5.00

8.82 6.10

Roadway 3 (M4)

Lm [cd/m²]

≥ 1.00

Uo

≥ 0.40

Ul

≥ 0.60

TI [%]

≤ 10

EIR

≥ 0.50

Roadway 2 (M4)

Lm [cd/m²]

≥ 1.00

Uo

≥ 0.40

Ul

≥ 0.60

TI [%]

≤ 10

EIR

≥ 0.50

Sidewalk 2 (P4)

Em [lx]

≥ 8.00

≤ 12.00

Emin [lx]

≥ 5.00

10.63 7.84

Results for energy efficiency indicators

EN 13201:2015-5 does not include the case for planning with multiple luminaire

arrangements The calculation of the output values is done therefore only for the

luminaire arrangement whose pole distance determines the length of the

valuation fields

Energy consumption density

Arrangement 1: BGP322 T35 1xECO106-3S/657 DC (360.0

kWh/yr)

0.4 kWh/m² yr Arrangement 2: BGP322 T35 1xECO106-3S/657 DC (360.0

kWh/yr)

0.4 kWh/m² yr

Philips BGP322 T35 1xECO106-3S/657 DC

Luminous flux (luminaire): 10621.66 lm Luminous flux (lamp): 11100.00 lm Operating Hours

Boom inclination (3): 5.0°

Light centre height (1): 12.000 m

Maximum luminous intensities

Luminous intensity class: G*3 Any direction forming the specified angle from the downward vertical, with the luminaire installed for use

* Luminous intensity values in [cd/klm] for calculating luminous intensity class refer to the output flux of the luminaire, according

EN 13201:2015

Arrangement complies with glare index class D.6

LUẬT

Street 1: Alternative 1 / Planning results

Trang 6

Sidewalk 1 (P4)

Light loss factor: 0.90

Grid: 10 x 4 Points

Em [lx]

≥ 8.00

≤ 12.00

Emin [lx]

≥ 5.00

8.82 6.10

Horizontal illuminance

30.00 m

5.00 m

11.25 m

2.50 m

11.25 m

5.00 m

LUẬT

Street 1: Alternative 1 / Sidewalk 1 (P4) / Isolines

Trang 7

Roadway 3 (M4)

Light loss factor: 0.90

Grid: 10 x 6 Points

Lm [cd/m²]

≥ 1.00

Uo

≥ 0.40

Ul

≥ 0.60

TI [%]

≤ 10

EIR

≥ 0.50

Horizontal illuminance

30.00 m

5.00 m

11.25 m

2.50 m

11.25 m

5.00 m

LUẬT

Street 1: Alternative 1 / Roadway 3 (M4) / Isolines

Trang 8

Observer 1

Luminance with dry roadway

30.00 m

5.00 m

11.25 m

2.50 m

11.25 m

5.00 m

LUẬT

Street 1: Alternative 1 / Roadway 3 (M4) / Isolines

Trang 9

Luminance with new lamp

30.00 m

5.00 m

11.25 m

2.50 m

11.25 m

5.00 m

LUẬT

Street 1: Alternative 1 / Roadway 3 (M4) / Isolines

Trang 10

Observer 2

Luminance with dry roadway

30.00 m

5.00 m

11.25 m

2.50 m

11.25 m

5.00 m

LUẬT

Street 1: Alternative 1 / Roadway 3 (M4) / Isolines

Trang 11

Luminance with new lamp

30.00 m

5.00 m

11.25 m

2.50 m

11.25 m

5.00 m

LUẬT

Street 1: Alternative 1 / Roadway 3 (M4) / Isolines

Trang 12

Roadway 2 (M4)

Light loss factor: 0.90

Grid: 10 x 6 Points

Lm [cd/m²]

≥ 1.00

Uo

≥ 0.40

Ul

≥ 0.60

TI [%]

≤ 10

EIR

≥ 0.50

Horizontal illuminance

30.00 m

5.00 m

11.25 m

2.50 m

11.25 m

5.00 m

LUẬT

Street 1: Alternative 1 / Roadway 2 (M4) / Isolines

Trang 13

Observer 1

Luminance with dry roadway

30.00 m

5.00 m

11.25 m

2.50 m

11.25 m

5.00 m

LUẬT

Street 1: Alternative 1 / Roadway 2 (M4) / Isolines

Trang 14

Luminance with new lamp

30.00 m

5.00 m

11.25 m

2.50 m

11.25 m

5.00 m

LUẬT

Street 1: Alternative 1 / Roadway 2 (M4) / Isolines

Trang 15

Observer 2

Luminance with dry roadway

30.00 m

5.00 m

11.25 m

2.50 m

11.25 m

5.00 m

LUẬT

Street 1: Alternative 1 / Roadway 2 (M4) / Isolines

Trang 16

Luminance with new lamp

30.00 m

5.00 m

11.25 m

2.50 m

11.25 m

5.00 m

LUẬT

Street 1: Alternative 1 / Roadway 2 (M4) / Isolines

Trang 17

Sidewalk 2 (P4)

Light loss factor: 0.90

Grid: 10 x 4 Points

Em [lx]

≥ 8.00

≤ 12.00

Emin [lx]

≥ 5.00

10.63 7.84

Horizontal illuminance

30.00 m

5.00 m

11.25 m

2.50 m

11.25 m

5.00 m

LUẬT

Street 1: Alternative 1 / Sidewalk 2 (P4) / Isolines