1. Trang chủ
  2. » Kỹ Thuật - Công Nghệ

Máy đóng bao xi măng haver boecker

156 2 2

Đang tải... (xem toàn văn)

Tài liệu hạn chế xem trước, để xem đầy đủ mời bạn chọn Tải xuống

THÔNG TIN TÀI LIỆU

Thông tin cơ bản

Định dạng
Số trang 156
Dung lượng 1,59 MB

Nội dung

Functional Overview.......................................................................................15 2. Parameter summary .......................................................................................26 2.1. Weigher parameters .......................................................................................27 2.2. Sort parameters..............................................................................................28 2.3. Adjustmentcalibration parameters .................................................................212 2.4. Display values.................................................................................................213 3. Functional description ...................................................................................314 3.1. Automatic function test ...................................................................................314 3.2. Functional sequence.......................................................................................316 4. Operating Instructions ...................................................................................433 4.1. Controls and display elements........................................................................434 4.1.1. Short dialog ....................................................................................................438 4.2. Main dialog .....................................................................................................441 4.2.1. Main menu......................................................................................................442 4.2.2. Sort parameters..............................................................................................443 4.2.3. Display values.................................................................................................462 4.2.4. Set up weigher................................................................................................463 4.2.5. Calibration ......................................................................................................465 5. Control messages...........................................................................................567 5.1. General status messages ...............................................................................567 5.2. Error messages ..............................................................................................569 6. Inputoutput signals........................................................................................678 6.1. Inputs..............................................................................................................681 6.2. Inputs..............................................................................................................682 6.3. Outputs ...........................................................................................................683 6.4. Outputs ...........................................................................................................684 6.5. Loadcell connector ........................................................................................685 6.6. Supply voltage ................................................................................................685 6.7. Terminal interface...........................................................................................685 6.8. DPS interface..................................................................................................686 6.9. Network interface............................................................................................686 6.10. Ethernet ..........................................................................................................686 7. Description of the inputoutput signals ........................................................787 7.1. Description of the input signals.......................................................................787 7.2. Description of the output signals.....................................................................796

HAVER ROTO - Packer - Configuration - Safety enclosure - External control - Bag discharge control - Bag filling ROTO -PACKER Aufbau Filling spouts Discharge belt Packing bin Direction of rotation Bag applicator - RADIMAT Jörg Bergelt SAFETY ENCLOSURE Safety doors – Access door (Radimat) – Internal door – Reject position Access door (1) is not Considered without Radimat bag applicator Jörg Bergelt SAFETY ENCLOSURE E – Emergency pull cord E Jörg Bergelt EXTERNAL CONTROL Aensteuerung Jưrg Bergelt R Z+ EXTERNAL AensteuerungCONTROL R Z+ - Start automatic - Start manual - Empty bag position - Reject position + - Bag discharge Jưrg Bergelt EXTERNAL CONTROL Aensteuerung R Z+ - Start automatic - Start manual - Empty bag position - Reject postion + – Bag discharge Jörg Bergelt R - Reset counter R Abwurf Bag discharge control + - 90 70 50 Discharge pre-set Discharge pre-set Jörg Bergelt 090 Abwurf Bag discharge control + - 90 70 50 Discharge pre-set Discharge pre-set Jörg Bergelt 070 Abwurf Bag discharge control + - 90 70 50 Discharge pre-set Discharge pre-set Jörg Bergelt 050 Range Calibration 50 kg The examining weight is put on the balance now 00.0 Range Calibration 027% 0.0000 Ulrich Ströker HAVER & BOECKER Range Calibration Climb by push the button the weight becomes taken by the balance 49.0 Area Calibration 051% 49.2386 Ulrich Ströker HAVER & BOECKER 50 kg Range Calibration The examining weight can be removed again 50.0 Range Calibration 051% 50.0000 Ulrich Ströker HAVER & BOECKER Range Calibration The balance runs back to zero 00.0 Range Calibration 051% 00.0000 Ulrich Ströker HAVER & BOECKER Mode R61? Yes/no If the balance has to be proofed by the gauging office , Select Yes 00.0 R61 fashion: Yes Ulrich Ströker HAVER & BOECKER Mode / Multi range / Multi Interval Choice climb by push this button 00.0 Operating Mode Multi range Ulrich Ströker HAVER & BOECKER Multi-Range weighing system Automatic shifting of scale setting in dependence of nominal load range scale marks = 10 g range scale marks = 20 g range kg 30 kg scale marks = 50 g 50 kg 100 kg Multi-Division weighing system Automatic shifting of scale settings in dependence of actual load kg range range range scale marks = 10 g scale marks = 20 g scale marks = 50 g 30 kg 50 kg 100 kg Zero correcting range minus-01.0 % You only can change if the R61 Mode is turned to NO 00.0 Zero correcting range - 01.0% Ulrich Ströker HAVER & BOECKER Zero correcting range plus 03.0% You only can change if the R61 Mode is turned to No 00.0 Zero correcting range 03.0% Ulrich Ströker HAVER & BOECKER Warm UP 00 This adjusted time runs the balance over before the balance is ready 00.0 Warm UP: 00 Ulrich Ströker HAVER & BOECKER Return to the Main Menu Push the button Esc to leave the Calibration Mode 00.0 Return to to Main Menu Ulrich Ströker HAVER & BOECKER The data are stored 00.0 - > EEPROM *************** Ulrich Ströker HAVER & BOECKER The button climb attaching push to sweep back to the pondering operation 00.0 Weigher on MECIII V24.4 Ulrich Ströker HAVER & BOECKER The normal pondering operation is switched on 00.0 Balance one MECIII V24.4 Ulrich Ströker HAVER & BOECKER HAVER & BOECKER

Ngày đăng: 16/10/2023, 08:32

TÀI LIỆU CÙNG NGƯỜI DÙNG

TÀI LIỆU LIÊN QUAN

w