Tài liệu hạn chế xem trước, để xem đầy đủ mời bạn chọn Tải xuống
1
/ 54 trang
THÔNG TIN TÀI LIỆU
Thông tin cơ bản
Định dạng
Số trang
54
Dung lượng
2,48 MB
Nội dung
APJS APJ1000 Jetting Valve Version: A01 Manual: Date:2017-7 Thanks for purchasing the product from axxon Before operate the product, please read the manual to get full understanding of its principle and specification, and use the recommend method of application and test, also, please correctly operate the product in the premise of notifications In addition, please pass the manual to each operator or user, thanks for cooperation There may have no pre-notification or specific change of the manual for product improvement, thanks for understanding If there have any questions or errors in the manual, please contact the company and office with the manual number and version to perfect the manual Online Manual: Copies of manual can be downloaded from the website: www.axxonauto.com If you need more help or have any other questions, please contact us using information below: Shenzhen Axxon piezoelectric Technology Co., Ltd FAX: +86-755-86540369 E-mail:jian.chen@axxonauto.com www.axxonauto.com Contents APIS APJ1000 Jetting Valve Product Introduction 1.1Product formation and specification 1.2Installation and structure 2.Jetting Valve Module APJ1000 2.1Partly List of Valve Package 2.2Instrument and dismounting 2.3Method of Application 2.3.1 Parameter Adjustment and Main Point 2.3.2 Method of Application 2.3.3 Preparation before Application 2.3.4 Operational Process 2.4Heated Jet nozzle module 3.Cold Melt Control Module D-170H 3.1 Specification and Parameter Description of D-170H Controller Configuration 3.1.1D-170H Controller Specification 3.1.2D-170H Description of Key Parameter 3.2Control Panel 3.2.1Control Front Panel 3.2.2LED Screen 3.2.3Control Back Panel 3.3LED Indicator Light Description 3.4Connted Diagram of Controller and Valve 3.5Controller Operational Description 3.5.1Menu Operation 3.5.2Heat Control 3.5.3Jetting Valve Control 3.5.4Power Down Reservation 3.5.5Starting Dispensing 3.6Connecting interface of Interface Description 3.6.1PLC Control Interface 3.7Jetting Valve and Heat Interface 3.8Communication Interface 3.9Common Fault of D-170H Controller 4.Hot Melt Control Module -D170M 4.1 Module Number and Specification of D-170M 4.1.1D-170M Controller Number 4.1.2D-170M Controller Specification 4.2Instrallment and Use 4.2.1D-170M Back Panel 4.2.2 Installation with D-170H 5.Parts List 5.1Standard Installation 5.2Optional Configuration Cassette Glue Barrel, syringe Feed 6.Maintanance 6.1Cleaning and Maintain of Flexible Contacted Part 7.Fault Diagnose 8.Comsumable and Replacement 8.1Quick Wear List 8.2Replacement List 9.Matters Need Attention 9.1Needed Configuration Recommend to Factory 9.2Dispense Volume Parameter Setting 9.3Heat Module 10.Key Point of Applicant Description 11.After-Salses Service 1.Product Introduction APJ1000 is a floating piezoelectric dispensing valve, which is wildly used in the field of SMT, conductive silver pulp, IC encapsulation adhesive, bottom filling adhesive, sealant and surface coating adhesive and other kinds of controllable quantity of flow and high speed dispensing work Not only it can inject glue into a narrow space that one hundred micrometer, but also can make precision dispensing with 0.01mg in the designated position In accordance with Au series automatic dispensing panel, APJ10000 jetting valve can bring maximum economic benefits to customers in the industries such as electronic packaging, lighting, energy and life science and technology, as well as the occasions where high precision and high efficiency are required and space limit Figure1.1 Specification of Main Parts Note: Please read the manual carefully and the follow product introduction to get better understanding of the product and working condition you want 1.1 Production Formation and Specification An integrated APJ1000 piezoelectric dispensing system concludes three parts: valve module APJ10000, cold melt controller module D-170H, hot melt adhesive module D-170M And valve module APJ1000 and cold melt controller module among them are basic parts used in cold melt dispensing, after adding hot melt module, APJ1000 can use hot melt dispensing Meanwhile, in order to satisfy different dispensing condition, it can be installed many other configurations that consumer can choose the suitable one in accordance with their own requirement (Figure 1.1 is decomposition of each module) Figure1.1 Decomposition of Heated melt module In Figure 1.1, all module(power line and valve signal line are not marked) are formed hot melt adhesive dispensing system which used in hot melt adhesive dispensing and other hot melt glue 1,2,3 (power line and valve signal line are not marked) formed cold melt adhesive dispensing system to be used in normal temperature dispensing condition Chart 1.1 shows model number of the whole module The detail specification of each module will demonstrate in the following section Chart 1-1 Numbers of Each Dispensing Part of Overall Module Numbers of Each Dispensing Part of Overall Module Product Name System Foreign Number CD10 01 Cold melt adhesive dispensing system Hot melt adhesive dispensing system HD10 01 No in Figure 1.1 Name of Product Module Model Cold melt controller D170H Piezoelectronic dispensing valve APJ1000 Nozzle heated module NH-100 7(not signed in the figure) Controller power line D170H01 8(not signed in the figure) Valve signal line D170H02 Hot melt adhesive control module D-170M syringe heated module JH-500 Chart 1.1 shows the performance and structural parameter of APJ1000 jetting valve, and its smallest achievable point diameter will be change with different glue Chart 1-1 performance and structure parameter of APJ1000 jetting valve APJ1000 dispensing valve performance parameter Maximum Work Efficiency 500 cycles/s Maximum Feeding Pressure 0~0.3 Mpa Minimum Spot Size 0.2mm Optimal Viscosity Range 1~200000cps APJ1000 dispensing valve structural parameter Outside Dimensions 99mm×78mm×12mm Weight 390g Feeding Components Stainless steel Luer taper connecting with needle(standard) Inverted connector feed tube(optional) Specification of connectable syringe 3CC、5CC、10CC、30CC、55CC Specification of connectable pipe 1/2 inch Piezoelectric encapsulation module Stainless steel Fluid chamber Stainless steel Firing pin assembly Hard rigidity material Nozzle module Hard rigidity material Fluid seal ring High abrasive resistance and thermal stability material made on purpose Other O-ring chemigum Heating module AL-Oxidization Heating pipe 24V(DC)30W Maximum heating temperature 100℃/135℃/145℃ *Note: The above data of APJ1000 performance parameter are result from particular pressure and fluid parameter condition In practical application, it should be decided in accordance with actual glue features and measuring condition 1.2 Installation and Structure This Figure shows the outside dimension and mounting hole site of valve module, which can be designed sectional fixture suited with panel in accordance with hole site dimension M4 is position of mounting screw、、、、、、、, φ4 is position of dowel hole.、、、、、、、、 Figure 1.2 APJ1000 outside dimension and mounting dimension Jetting Valve module -APJ1000 This chapter is detailed introduction of APJ1000, including its method of application and dismantling device, and application and installation method of heat part of cold melt adhesive It takes protection case to package, which including valve, nozzle heated module and dismounting spanner All these configuration will be individual packed and be individual valve product The number of product is APJ1000 2.1 Valve Package List APJ1000 valve module includes valve, nozzle heat module and dismounting spanner Figure 2.1 is explosive diagram, and figure 2.2 is numbers of dismounting tools diagram Figure 2.1 number of explosive diagram of valve module Chart 2.1 dismounting instruments Chart 2.1 is package list of valve, nozzle heated device and dismounting device in APJ1000 The number is one to one correspondence between chart and the above figure Chart 2.1 APJ1000 Valve Module Package List Number P/N Part Description Notes APJ1000 Piezoelectronic jetting valve Figure 1.1 NH-100 Nozzle heat block Figure 1.2 APJ1001 Piezoelectronic module 10 APJ1002 Needle stand 11 APJ1003 screw 12 APJ1004 Ceramic gasket 13 APJ1005 screw 14 APJ1006 Firing pin 15 APJ1007 Spring 16 APJ1008 Support pin 17 APJ1009 Sealing package 18 APJ1011 Luer contact 19 APJ1010 Incubation tube feeding support 20 APJ1012 Luer taper 21 APJ1013 O-circle 22 APJ1014 screw 23 APJ1015 Fluid channel 24 APJ1016 Seal ring 25 APJ1017 Support pin 26 APJ1018 O-circle 27 APJ1019 Nozzle cage 28 APJ1020 screw 29 APJ1021 Nozzle ×2 ×2 ×2 ×2 Dismounting Device 30 APJ1022 Nozzle spanner 31 APJ1023 Guide spanner 32 APJ1024 Nozzle dismounting suit 33 APJ1025 Brush 34 APJ1026 odontorine 35 APJ1027 Nozzle cleaner Parts can be changed in accordance with explosive diagram, and parts information can be checked by product numbers Just provide parts number and parts description when making parts purchasing 2.2 Device and dismounting Device instructions of APJ1000 Guide spanner No.31: one end of it is to adjust nozzle: tighten nozzle in clockwise direction or loosen in anticlockwise direction; the other end can adjust the guiding of firing pin Nozzle spanner -No.30: nozzle is screwed on vertical fluid channel, which make nozzle can connect firing pin in just condition Nozzle extrusion device No.32: If the nozzle and nozzle fastener contacted too tighten, using nozzle extrusion device push out nozzle But don’t push too hard, in case nozzle goes out Figure2.3 Method of application of guide spanner Figure2.4 Method of application of Nozzle Spanner Figure 2.6 Method of application of nozzle extrusion device Example: Input: NOZZLE:SET:500000 Come: 500000 times dispensing cycle is selected Display: OK 35 NOZZLE:CLEAR Description: Example: Count of nozzle maintaining will be clear Input: NOZZLE:CLEAR Come: resetting count is “0 Display: OK 36 SYSTEM:SHOW:AKTORTEMP Description: Display brake(piezoelectric) current temperature Example: Input: SYSTEM:SHOW:AKTORTEMP Come: displaying unit of numeral value is℃ Display:80 37 HELP: Description: Example: Input: HELP Come: list of RS-232C instruction Display: instruction list 3.9 Common fault of D-170H controller Chart3.10 common fault of D-170H controller fault Possible cause and solution Error code ERR1 Inputs from thermocouple may not insert well or switch off, please check thermocouple input Error code ERR4 Temperature alarm if the difference of current temperature and setting temperature is greater than±1℃, controller will automated control temperature difference within±1℃ Please dispensing after temperature stabilized No action after trigger valve When in cycle mode, if count is more than setting times, the trigger will invalid Please clear count When get into menu and trigger invalid, please go back to home screen and trigger again If keyboard trigger is efficient but signal trigger is inefficient, please check connection of trigger input and make sure pulse width of trigger signal is more than 2ms hot melt adhesive controller module D-170M The main function of D-170M controller is hot melt adhesive which can realize nozzle and syringe heating at the same time with D-170H D-170M combining with D-170H can be used in hot melt adhesive This module is adopted individual package which can be an individual product The number of it is D-170M 4.1 D-170M serial number and specification of control module The introduction of this part is mainly about the hot melt number and specification of adhesive auxiliary module which has independently package and selling When hot melt adhesive is dispensing, the valve needs cooling Cooler can between 0.02MPa-0.05MPa 4.1.1 Items of D-170M controller This controller only has two components: power module D-170M and nozzle heating module These two modules form a hot melt adhesive heating module The following Figure is auxiliary module of hot melt adhesive The following chart is number of auxiliary of hot melt adhesive module, and customer can ask our information of hot melt adhesive in accordance with the following number Chart4.1 Number of D-170M controller Item Part number Part description Note D-170M Hot melt adhesive JH-500 Syringe heat block Item Part number Part description Note 48 D-170M01 Bond wire of hot melt controller As Figure 4.4 The following Figure shows the installment method of the syringe heating and the valve body: after concentric interlink nozzle and Luer part together, use a M3 screw to fix and connect nozzle and valve body Figure4.2 installment of nozzle heating 4.1.2 D-170M controller specification The following chart is D-170M controller specification, and customers can make equipment integration in accordance with its specification Chart4.2 D-170M controller specification D-170M controlling module specification Size 241*160*57MM Weight 1.2KG Power input 220VAC±20%、50/60HZ 4.2 Installation and Application 4.2.1 D-170M back panel D-170M port Syringe heating port Figure4.3 back panel of controller of hot melt adhesive 4.2.2 Installment with D-170H Hot melt adhesive controller D-170M connects by four threaded hole of cold melt adhesive controller D-170H And D-170H and D-170M can be connected by cable By adjusting Heater of D-170H to set syringe heating can achieve hot melt adhesive controlling Connection cable Figure 4.4 connection of hot melt adhesive controller List of Parts 5.1 standard configuration According to different applications and requirements, Axxon APJ1000 jetting valve can have different configurations and the following picture is the typical configuration: Figure 5.1 APJ1000 Typical configuration According to typical configuration of APJ 1000 valve module, the following picture is breakdown drawing and parts list of Figure 5.1 and Chart 5.1 : Chart 5.1 APJ1000 valve module typical configurations APJ1000 valve module typical configuration Item Parts number Parts description Note NH-100 Nozzle heating See Figure 1.1 APJ1001 Piezoelectric module 10 APJ1002 Syringe bracket 11 APJ1003 Screw 12 APJ1004 Ceramic gasket 13 APJ1005 Screw ×2 ×2 14 APJ1006_* Firing pin See chart5.2 15 APJ1007 Spring 16 APJ1008 Bracing piece 17 APJ1009 Sealing packing 18 APJ1011 Luer taper 19 APJ1010 spigot joint 20 APJ1012 Luer bracket 21 APJ1013 O-ring 22 APJ1014 Screw 23 APJ1015 Flow channel 24 APJ1016 Seal ring 25 APJ1017 Support pillar 26 APJ1018 O-ring 27 APJ1019 Nozzle cage 28 APJ1020 Screw ×2 29 APJ1021 nozzle See figure 5.2 ×2 Dismantling device 30 APJ1022 Nozzle spanner 31 APJ1023 Guidance spanner 32 APJ1024 Nozzle dismantling cover 33 APJ1025 hairbrush 34 APJ1026 odontorine 35 APJ1027 Nozzle cleaner Optional configuration of firing pin: Chart 5.2 parts number of firing pin configuration and nozzle specification Item Parts number Parts description 36 APJ1006-1 Nozzle 50um 37 APJ1006-2 Nozzle 75um 38 APJ1006-3 Nozzle 100um 39 APJ1006-4 Nozzle 200um 40 APJ1006-5 Nozzle 300um 41 APJ1006-7 Nozzle 400um 42 APJ1006-8 Nozzle 125um 43 APJ1006-9 Nozzle 150um 44 APJ1006-10 Nozzle 100um-2.5 45 APJ1006-11 Nozzle 100um-5 46 APJ1006-12 Nozzle 200um-5 47 APJ1021-1 0.75mm exclusive firing pin 48 APJ1021-2 1.0mm exclusive firing pin 49 APJ1021-3 1.5mm exclusive firing pin 50 APJ1021-4 2.0mm exclusive firing pin note 50* 5.2 APJ1021-5 1.5mm hard firing pin The other optional configuration- cassette glue barrel, syringe feeding When using mass flow dispensing, APJ1000 jetting valve can connect feeding tube which transport by cassette glue barrel, pressure tank and other bulk storing equipment to realize dispensing continuously And when dispensing flux is smaller, syringe feeding can be adopted directly The Figure is as follows: Figure4.3 optional configuration of APJ1000 dispensing valve Parts number chart of cassette glue barrel joint Item Parts number Parts description 51 APJ1029 Syringe stand of incubation tube feeding 52 APJ1028 Incubation tube feeding Not e Maintenance APJ1000 needs appropriate cleaning and maintenance after each using to prolong its vulnerable parts life and make sure the consistency and high quality of dispensing After long time using (usually one week), the valve needs completely maintenance 6.1 Cleaning and Maintenance of fluid contacting parts Core maintenance of APJ1000 dispensing valve is the fluid contacting parts, in case fluid solidification, blocking in the tube after long time nonuse Cleaning and maintenance steps are as follows: (1) Close feeding pressure and turn the pressure to 0; break the controller power line and remove signal cable, heating connecting line and so on (2) Dismount APJ1000 jetting valve from fixed panel of platform (3) Use nozzle spanner, overlook it and unscrew it in clockwise rotation Nozzle spanner Nozzle cage Figure6.1 The direction of unscrewing nozzle cage (4) Take down nozzle cage, nozzle, nozzle fastening and sealing O-ring carefully from fluid channel; as the Figure 6.2 shows that using cleaning swab scrub glue on surface of unscrewing nozzle Then using 1.5 nozzle cleaner export glue in the nozzle fastening and using cleaning swab scrub glue on the mural of internal fluid channel Nozzle cleaning: export glue in the pore of nozzle by using odontorine, then blowing out left glue by pneumatic gun Repeat this operation to ensure that there is no glue in dispensing nozzle; Method of odontorine unchoking nozzle is as the following Figure 6.3 Finally, put nozzle and nozzle fastening into ultrasonic wave clean at least 10 min, then blowing solvent in the surface of nozzle Then to observe condition of pore nozzle and if there still have glue, the cleaning step needs to repeat SPECIAL ATTENTION: These parts need to be taken down from erect flow channel in case scratch or lose O-ring is forbidden to soak into cleaning solvent, including ethyl alcohol Guidance spanner O-ring Superior branch of nozzle Nozzle cage Nozzle Figure 6.2 dismounting and cleaning of nozzle odontorine nozzle Figure6.3 method of dismounting nozzle (5) Use 2.5mm hex wrenches to unscrew M3 socket head cap screw to separate fluid channel and valve Fluid channel should be taken down carefully Because seal ring has some force of friction, after unscrewing to an extent, fluid channel needs to be hardly pulled down As the Figure 6.4 shows Fluid module Figure 6.4 dismounting underneath chamber (6) After dismantling liquid channel, erect liquid channel and Luer bracket need to be split off by 2.5mm hex wrenches; then the Luer taper is unscrewed by the other end of dispensing spanner Cleaning inside wall which has liquid by 1.5mm nozzle cleaner and hairbrush, after then, Luer taper, Luer bracket and erect liquid are all put in ultrasonic equipment at least 10 minutes Specific information is as the follow Figure 6.5 All dismantling O-ring, sealing packing and (、、) spring seal can’t be soaked by cleaning solvent, including ethyl alcohol Luer Taper Luer Stand O-ring M3 screw Sealing packing Spring seal Erect liquid channel Figure6.5 dismantling of liquid module Specific cleaning procedure of Luer taper, Luer brakcet, and erect liquid channel Nozzle cleaner Hair brush Figure6.6 The cleaning method of liquid channel (7) Procession of dismantling of firing pin: when it is necessary, using the end of two convex foot of guide wretch dismantle firing pin Show as the Figure6.7 The surface of firing pin is cleaned by dust-free cloth which is dipped in cleaning solution Firing guide Guide wretch Firing pin Figure6.7 dismantling and cleaning method of firing pin (8)After finishing steps above and ensuring each part is cleaned Please assemble them in inverted sequence in accordance with dismantling sequence Note: In case of temporary discomfort afer cleaning, the quick-wear injector nozzle should not be installed directly on the rubber valve It should be kept properly and separately, lest the rubber valve accidentally fall or hit the sharp parts and damage the nozzle fault diagnosis APJ1000 is devoted to give the most cost-effective equipment to customers, because it’s a stable product which is easy to maintain and customers can easily adjust and maintain according to the following chart when facing the common fault in production If there still have any other problems, please contact with our professional technical supports, they will give better advice to you So please don’t to dismantle blindly in case invocatable damage Chart7.1 fault handling instructions Fault performance Possible cause Handling method No glue exudation from nozzle Nozzle plugging Nozzle cleaning Viscosity is too high Increase heating temperature Feeding pressure is too low Increase feeding pressure to 0.1~0.3Mpa Loose or break cable or electric connection Check connection of all systemcable and electricity Parameter setting is wrong Check the parameter setting of controller Easily 、、 hanging glue Glue splash Glue leakage Controller fault Check whether there error information of controller Viscosity is too high Increase heating temperature, decrease viscosity of glue Range is too short Adjust upward stroke parameters of valve on controller to increase range Parameters setting of switch is unreasonable Adjust rising time, opening time falling time and delay time of controller Range is too large Adjust rising stroke parameters of controller to decrease range Height of nozzle is too high Decrease height of nozzle with work piece Nozzle leakage Check whether the valve is on power, if it’s on power-up state normally, then to check sealing of firing pin and nozzle Peep hole leakage If there has excessive glue on chamber, seal ring (APJ1037) is damaged *Note: Usually, the higher temperature glue will decrease viscosity of glue to produce higher rate of flowing But before using, sensibility of glue to temperature must be checked Too higher temperature isn’t benefit for viscosity but to accelerate solidification of glue or lead it denaturation consumable replacement part 8.1 wearing part list Axxon APJ1000 dispensing valve has excellent part quality to make sure its long service life in like products The Chart8.1 lists all wearing replacement parts of Axxon APJ1000 Customers can buy one or more suit in real production Chart 8.1 Wearing replacement parts Item Parts number Description note 14 APJ1006-* Firing pin See details in 5.2 17 APJ1009 Sealing gasket 21 APJ1013 O-ring 24 APJ1016 Sealing plug 26 APJ1018 O-ring 29 APJ1021-* nozzle See details in 5.2 8.2 spare parts list Timely and correctly maintenance is very important to improve production efficiency and prolong service life Axxon APJ1000 dispensing valve sends relevant tools and other cleaning suit and other spare parts which can make maintenance easier The chart 8.2 lists spare parts Chart 8.2 spare parts list Item Part mark description note 30 APJ1022 Nozzle wretch 31 APJ1023 Guide spanner 32 APJ1024 Nozzle extrusion tool 33 APJ1025 Hairbrush 34 APJ1026 odontorine 35 APJ1027 Nozzle cleaner 53 APJ1041 nonwavens Dry scrub 54 APJ1043 lubricate Lubricate guide friction position matters need attention The full understanding and preparation of the items in this chapter can be more beneficial to the use of products and help customers to be more efficient and safer production 9.1 Recommendation of required objects in factory Electron microscope: to observe focus or bubble and other fault Ultrasonic cleaning device: cleaning channel, saving maintenance time Pneumatic gun: cleaning raffinate on surface, efficiency and shortcut Industrial alcohol (solvent): dissolving medium, cleaning in wall of channel and prevent glue pollution when change another glue Collective vessel of raffinate: depollution workbench 9.2 Setting parameter of dispensing volume In the process of dispensing volume adjustment, there has four features to change the volume directly: feeding pressure, firing pin range, nozzle specification and adjustment time and dot number of piezoelectric Different applicable condition needs different parameter and accessories cooperating together that can make idealized production effect, and we don’t recommend to change any parameters blindly We abide by using the minimum dots number and shortest time to produce the best product Unlimited increase dots number and opening time will increase friction and can’t realize dispensing result Specific applicable configuration will be guided by our professional technical supports 9.3 Heating module Valve that needs to add heating module should be checked the fixation of thermal probe and heating block On the process of using, once the condition of falling or leaking has happened, please turn off the temperature control device as soon as possible 10 Specification of operational key points In order to make customers better use this type of product, the summary specification of APJ1000 is as follows: If the equipment is not applicable at some time, you’d better to close the power of controller Reason: If equipment has power but don’t work for a long time, it will not operate so fluently when it open again and parameter needs to be reset usually Turning off the power and opening it again, the equipment can be used again with previous parameter Prohibit hot plug Reason: when valve power on, plugging the signal line on valve body may lead overshoot and cause damage to valve which may give irreversible damage to dispensing performance Must having heat dissipation after long time successive using Reason: decreasing temperature can output more stable and cooling air pressure which is usually in 0.02~0.05MPa, cooling air must be filtered lest short circuit by moisture Shorten range as much as possible and try not to use full range; Reason: ceramics driven has more powerful signal to move more quickly which will be more sensible to electric signal and easier to be interrupted After the valve is opened, the nozzle should be tightened to seal Reason: piezoelectric only needs very small output displacement can realize dispensing If it is tightened too much, it will be condensed a part of output position and decrease performance So it shouldn’t be tightened too much Hard disk temperature controlling Monitor hard disk temperature When hard disk temperature is too hot, the last executive order is shut down Valve temperature controlling Monitor valve temperature When valve temperature is too hot, the last executive order is shut down 11 Afer sales service The term of service of APJ1000 is rated life of the product which is delivered to the appointed place Malfunction in normal use condition, local agencies can provide free maintenance and part change (except accessories included) If one of the following situations occurs, it does not belong to the free warranty service category, and the corresponding person shall be charged labor and material costs, and the warranty period of the equipment is full: Valve can’t operate normally because of inappropriate working condition, overburden working or trying some applicant beyond valve performance Valve modified by oneself and lead valve can’t operate or no trouble inside and outside or damage Valve can’t operate normally because of violation operation or inappropriate operation or other human factors Valve can’t operate normally because of earthquake, flood or other force majeure which is irrelevant to the valve itself Valve performance is decreased or can’t operate because daily maintenance is not enough Any other improper condition ... chart5.2 15 APJ1007 Spring 16 APJ1008 Bracing piece 17 APJ1009 Sealing packing 18 APJ1011 Luer taper 19 APJ1 010 spigot joint 20 APJ1012 Luer bracket 21 APJ1013 O-ring 22 APJ1014 Screw 23 APJ1015 Flow... Spring 16 APJ1008 Support pin 17 APJ1009 Sealing package 18 APJ1011 Luer contact 19 APJ1 010 Incubation tube feeding support 20 APJ1012 Luer taper 21 APJ1013 O-circle 22 APJ1014 screw 23 APJ1015 Fluid... 24 APJ1016 Seal ring 25 APJ1017 Support pin 26 APJ1018 O-circle 27 APJ1019 Nozzle cage 28 APJ1020 screw 29 APJ1021 Nozzle ×2 ×2 ×2 ×2 Dismounting Device 30 APJ1022 Nozzle spanner 31 APJ1 023 Guide