MRI safety

30 9 0

Đang tải... (xem toàn văn)

Tài liệu hạn chế xem trước, để xem đầy đủ mời bạn chọn Tải xuống

THÔNG TIN TÀI LIỆU

Thông tin cơ bản

Định dạng
Số trang 30
Dung lượng 1,09 MB

Nội dung

MRI Safety This slide show will educate all healthcare providers about the safe delivery of care in the magnetic resonance (MR) environment This slide presentation has been adapted for Nursing from an original presentation compiled by: Deborah Schwengel, M.D Christopher Pressley, M.D Kaadze Wright, M.D Robert W Evers, BSRT, MR, CV THE MAGNETIC FIELD IS AT FULL POWER ALWAYS ….IT IS ALWAYS “ON” EMPLOYEE SAFETY ALL EMPLOYEES MUST BE SCREENED TO WORK IN A MAGNETIC FIELD ENVIRONMENT JUST LIKE THE PATIENTS NO EXCEPTIONS MRI PROCEDURE SCREENING FORM To ensure patient safety, completion of the MRI screening form is required prior to every MRI scan Units can assist & expedite the MRI's triage process by completing this form in advance and faxing to 2-8582 This form is located online at: http://www.rad.jhmi.edu/requisitions.htm MRI Screening Sheet All Patients will need this form filled out before an MRI can be done Ideally, the form should be filled out by: a The Patient If the patient cannot fill it out: b Family Members If there are no family members: c Referring MD What to in an Emergency • If there is a Patient Emergency in MRI… – GET THE PATIENT OUT OF THE ROOM – NO CODE OR CODE LIKE PROCEDURES WILL BE RUN IN THE MRI ROOM BURNS • It is “possible” for patients to get 1st, 2nd, or even 3rd degree burns in an MRI if items such as ECG cables are looped and are touching the patients skin (even if these devices are MRI compatible) – All “cables” should not touch the patients skin directly, and should NOT be in a LOOPED configuration What can you take into a magnetic field? • ONLY ITEMS THAT ARE MRI COMPATIBLE Such as… – Brass – Aluminum – Plastic – IF YOU ARE NOT SURE IF AN OBJECT IS MRI SAFE…DON’T TAKE IT INTO THE ROOM ASK A TECHNOLOGIST!!!!!!!! Magnetic Field • What “objects” can you take into a magnetic field? Anything that doesn’t contain iron To be safe…TAKE NOTHING INTO A MAGNETIC FIELD Work closely with the Technologist who works in that type of environment each day Question Everything Site Access Restriction: Screening • All patients presenting for a non emergent scan must be screened by two MR personnel, including one with level qualifications • A detailed history on possible implants or metallic objects must be obtained in writing and signed by appropriate medical licensed personnel • Do not rely on verbal history alone Pacemakers There several reports in the literature describing the occurrence of sudden death in the MR for patients with implanted (but MR compatible) pacers To date the mechanism of these fatalities is unclear but is thought to be secondary to the induction of fatal arrythmias Therefore pacemakers are currently a contraindication to MR scanning Forces in the MR Environment • Magnetic field – missile effect: TRANSLATION – rotational effect: ROTATION/TORQUE Translational Force • this term describes the force which attracts ferrous objects to the center of the magnetic field • may act to transform ferrous objects into missiles as they accelerate toward the magnet • the force is greatest when the difference in field strength across the object is greatest; where delta T or difference in field strength from point A to point B is maximized A B Rotational Force • this force relates to the North - South orientation of the scanner’s magnetic field • ferrous objects will attempt to align their long axes with this orientation • this force will rotate objects until they are aligned and is greatest at the very center of the field (unlike the translational force which is greatest where the difference in magnetic field across the object is greatest) Another danger in MRI -QUENCH! • MR scanners are supercooled with inert gases such as helium • If these cryogens BOIL OFF either intentionally or unintentionally, a quench has occurred THIS IS EXTREMELY BAD • An INTENTIONAL quench is done in an emergency to run the magnetic field to ZERO in order to remove a projectile/patient from the scanner in extreme emergencies • If a quench occurs, remove all staff from the room immediately Another danger in MRI -QUENCH! • THE WORRY WITH A QUENCH IS THE POTENTIAL FOR ASPHIXIATION AND FROST-BITE TO THE HEALTH CARE WORKER AND PATIENT Pregnant Patients or Personnel: • Pregnant patients regardless of trimester are only scanned if the results of the study will change the care of the patient • Pregnant MR personnel are encouraged not to stay in the room during the scanning process Introduction to the zone system for maintaining safety in the MRI suite Site Access Restriction – All personnel with access to MR must have either level or level qualifications – Level personnel are minimally trained in MR safety and can ensure their own safety and the safety of a patient in the MR environment – All JHH anesthesiologists must have level qualifications Site Access Restriction • Level personnel are extensively knowledgeable about the MR environment, the potential hazards of the agents and equipment used, and MR safety precautions • The MR safety director, and all MR radiology technologists are level personnel Safety Zones • Zone : This is a public access area with no restrictions • Zone : This is a semi restricted area where patients and hospital staff can interact • Zone : This area is completely physically restricted from non MR personnel especially the general public Remember this mnemonic: MRI = Metal Results (in) Injury The End ... EMPLOYEE SAFETY ALL EMPLOYEES MUST BE SCREENED TO WORK IN A MAGNETIC FIELD ENVIRONMENT JUST LIKE THE PATIENTS NO EXCEPTIONS MRI PROCEDURE SCREENING FORM To ensure patient safety, completion of the MRI. .. medical device is safe in the MRI environment • The MRI staff are always equipped with the latest information on device safety • Questions should be directed to the chief MRI technologist Pacemakers... in MRI? ?? – GET THE PATIENT OUT OF THE ROOM – NO CODE OR CODE LIKE PROCEDURES WILL BE RUN IN THE MRI ROOM BURNS • It is “possible” for patients to get 1st, 2nd, or even 3rd degree burns in an MRI

Ngày đăng: 13/08/2020, 09:10