1. Trang chủ
  2. » Giáo Dục - Đào Tạo

Catalog nikken english vol2

56 198 0

Đang tải... (xem toàn văn)

Tài liệu hạn chế xem trước, để xem đầy đủ mời bạn chọn Tải xuống

THÔNG TIN TÀI LIỆU

Nội dung

NIKKEN TEMPORARY MATERIALS CATALOG NIKKEN INTERNATIONAL ASIA CO., LTD VOL NK SUPPORT CÔNG TY TNHH NIKKEN INTERNATIONAL ASIA SYSTEM NK SUPPORT CÔNG TY TNHH NIKKEN INTERNATIONAL ASIA SYSTEM CÔNG TY TNHH NIKKEN INTERNATIONAL ASIA NK SUPPORT CÔNG TY TNHH NIKKEN INTERNATIONAL ASIA SYSTEM SCAFFOLDING BY FRAME SCAFFOLDING BY NKL SYSTEM CÔNG TY TNHH NIKKEN INTERNATIONAL ASIA Exclusive member of NKL scaffold system (ø42.7) NIKKEN RENTACOM GROUP NIKKEN RENTACOM CO.,LTD NIKKEN LEASE KOGYO-MANILA BRANCH NIKKEN INTERNATIONAL MYANMAR 10 NIKKEN LEASE KOGYO-JAKARTA AGENCY Exclusive member of shoring system Drawing of AX beam Illustration image At places where side beam is arranged, plywood of beam form work needs to be cut 8mm innerly At joint of plywood, put battern cleat to AX beam and fix with nails Illustration image Support system for beam form work needs to be supported laterally by columns limit of supporting laterally by column as much as possible Max 150 00 Max Max 400 250~300 Notes for using Don't cast concrete partially at one place Don't load partially on AX beam Don't use old plywood or urqualified ones for beam Support bar of form - work is placed with the largest distance 400 mm; distance of thread rod 700 mm NIKKEN INTERNATIONAL ASIA CO.,LTD 33 Rolling scaffold system Support system for form-work of beam HK1400 10.35Kg HKB Code 3.3Kg Weight HKJ 2.0Kg HKTB 1.8Kg 84 84 Upper jack HKJ 72 Steel 50x50x2,3 190 100 100 100 190 330 Wingnut M16 HKTB B 100 330 40 40 H Bracket HKB Conecting bolt M16 250 Hole Ø17 mm 50=200 500 Stringer -100x40x3 (double) HK1400 50=200 250 1400 Default lateral pressure per set is 10.00 KN Width of adjustment beam: B = 300 mm ~ 700 mm Height of adjustment beam: H = 300mm ~ 700mm Installation of support system for form-work of beam NIKKEN INTERNATIONAL ASIA CO.,LTD 34 Other exclusive materials Mobile ladder Name Mobile ladder Code Height H (mm) Width W (mm) Length L (mm) Weight Load (Kg) MY 18 1456~1817 799~865 2606~2834 26,9 150 1456 ( Min) 1817 ( Max) 602 1616 2606 ( Min) 2834 ( Max) Installation NIKKEN INTERNATIONAL ASIA CO.,LTD 35 Strength test result of NK support system NIKKEN INTERNATIONAL ASIA CO.,LTD 36 Strength test result of NK support system NIKKEN INTERNATIONAL ASIA CO.,LTD 37 Strength test result of NK support system (Ø 48.6) According to chapter 240, section 3, item of Japan Industrial Safety and Health law: Incase allowable load which is declared by manufacturer is not clear, the materials are not allowed to be used as shoring support If basing on test result, in case the test condition is the same as actuality, safety coefficient must be from Allowable load and fracture load test No No Assortment Test load kN Allowable load kN (Safety factor) Test mothod No Assortment Test load kN Allowable load kN (Safety factor) Test mothod P Load testing NK-D NK-D NK-D NK-D NK-D NK-D NK-D NK-D NK-D NK-D NK-D NK-D NK-D NK-D 4,050 Joint NK-D NK-D Compressive strength 99.425/vertical of vertical (397.7/4vertical) NK-D 1,800 Exclusive Brace 28.5/vertical (3.48) 1,219 Compressive strength of upper jack 501 NK-D NK-D Load testing 186.2 65.0/vertical (2.86) NK-D 1,219 (in case of fixed pedestal) P Load testing NK-D NK-D NK-D NK-D NK-D NK-D NK-D NK-D NK-D NK-D NK-D 4,050 Joint NK-D NK-D NK-D NK-D NK-D NK-D NK-D NK-D NK-D NK-D 65.0/vertical (2.00) NK-D NK-D Compressive strength 130.875/vertical of vertical (523.5/4vertical) NK-D NK-D Vertical Direction NK-D NK-D 1,200 Exclusive Brace 1,219 NK-D 10.0/vertical (3.09) 30.96 Joint’s bending strength (New type) 250 P NK-D Horiontal Direction 1,219 D NK-D NK- Load testing 13.06 4.0/vertical (3.26) 250 Tensile load Vertical Direction Vertical’s joint (Joint: NKJ) tensile strength 17.0/vertical (3.28) 55.90 10.0/vertical (3.42) 34.27 250 Joint’s bending strength Horiontal Direction 4.0/vertical (2.90) 11.63 Tensile load 250 [Plan] P Compressive strength of base jack 65.0/vertical (4.24) 276.1 501 HL12 L=1.2m Horizontal bending strength incase of central concentrated load 4.5/vertical (2.30) 10.37 (20.75/2vertical) [Side view] HL18 L=1.8m 6.32 (12.64/2vertical) 3.0/vertical (2.10) (in case of fixed pedestal) L NIKKEN INTERNATIONAL ASIA CO.,LTD 38 Strength test result of NK support system (Ø48.6) Allowable load and fracture load test Assortment Brace Strength (H=1 8m) Test load kN Allowable load kN (Safety factor) Test mothod w=1.829m 23.52 (NKB1818) (94.1/4vertical) [Plan] 6.0/vertical (3.92) w=1.524m (NKB1518) 6.0/vertical [Side view] w=1.219m (NKB1218) 6.0/vertical W w=0.914m (NKB0918) 1,800 w=0.610m (NKB0618) Test load kN Test mothod Allowable load kN (Safety factor) Central load 14 NK side bracket's strength 27.375 (109.5/4vertical) Central 12.90 load (51.6/4vertical) (shortest) 450 1,060 4.0/vertical (6.84) 4.0/vertical (3.22) 6.0/vertical 3.5/vertical w=1.829m (NKB1812) Assortment 450 No Central 4.925 load (19.7/4vertical) (longest) 2.0/vertical (2.46) 1,670 (2,278) 12.0/vertical [Plan] w=1.219m 25.45 [Side view] (NKB1212) (101.8/4vertical) 12.0/vertical (2.12) w=0.914m 24.22 (NKB0912) (96.9/4vertical) 12.0/vertical (2.01) w=0.610m (NKB0618) 11 NK bracket diagonal brace comprehensive strength NK bracket joint's 12 bending strength Vertical Direction (Upper part) W Brace Strength (H=1 2m) 12.0/vertical 1,200 16.07 (64.3/4vertical) 75.38 2,103 10 w=1.524m (NKB1512) Exclusive bolt 7.0/vertical (2.29) 14.0/vertical (5.38) 10.0/vertical (3.68) 36.84 250 Vertical Direction (Lower part) 10.0/vertical (3.54) 35.45 250 Tensile loading 13 NK bracket tensile strength 41.30 10.0/vertical (4.13) NIKKEN INTERNATIONAL ASIA CO.,LTD 39 Strength test of NKL (Ø 42.7) Allowable load and fracture load test No Assortment Test load kN Test method Allowable load kN (Safety factor) No 9.8/vertical (2.15) 10.0/vertical (3.54) Assortment Test load kN Test method Allowable load kN (Safety factor) 900 Load testing Joint 1,900 4,590 Compressive strength 21.22/vertical of vertical (84.88/4vertical) 1,590 Exclusice Brace 1,219 1,219 Tensile load Vertical's joint (Joint pin NKJ) tensile strength Joint 35.4 Tensile load P Vertical 24.9 Direction (49.8/2vertical) 10.0/vertical (2.49) Joint's bending strength (New type) 250 P Horizontal Direction 4.0/vertical (3.35) 13.4 250 【Plan】 9.75 HL12L L=1.219m (19.5/2horizontal) Horizontal bending strength in case of central concentrated load 4.0/horizontal (2.43) 【Side view】 P HL18L 6.35 L=1.829m (12.7/2horizontal) 3.0/horizontal (2.11) L w=1.829m 7.7 (NKX18) (30.8/4vertical) 2.0/vertical (3.85) 【Plan】 w=1.524m Brace Strength w=1.219m (H=1.8m) 【Side view】 P w=0.914m (NKX09) w=0.610m 10 W 1,950 NIKKEN INTERNATIONAL ASIA CO.,LTD 40 Introduction of construction site 41 Introduction of construction site Building work Support W15mxH14m Molex 42 Introduction of construction site Building work W230mxH5m ■ Hamatetsu steel factory 10 Bridge W18m×D11m×H8m ■ Nhat Tan Bridge 11 Building work W6m×H14m ■ Seowon Intech project 43 Introduction of construction site 12 Building work W114m×H14m ■ Toyota factory project 13 Building work W20m×D15m×H7m W15m×D15m×H7m ■ P&G project 14 Bridge Support W18m×D16m×H20m ■ Nhat Tan project 15 Building work W202m×H16m ■ LEO project 44 NIKKEN TEMPORARY MATERIALS CATALOG VOL Issued: November 2016 Edited by Nikken International Asia Co., Ltd 45 Any unauthorized duplication or reproduction without permission is strictly prohibited Ha Noi Warehouse: Address at Vina- Fuji Co.,Ltd, Quang Minh II Industrial Zone, Me Linh, Ha Noi Ho Chi Minh Warehouse: Address at Khai Hoan Joint Stock Company, Street 7, Tam Phuoc Industrial Zone, Bien Hoa, Dong Nai NIKKEN INTERNATIONAL ASIA CO., LTD Address : 6th Floor, Toyota My Dinh Bld., No 15 Pham Hung Str., My Dinh Ward, Nam Tu Liem Dist., Ha Noi Tel : (+84) 043-7688-942 Fax : (+84) 043-7688-943 Warehouse: Vina- Fuji Co.,Ltd, Quang Minh II Industrial Park, Me Linh, Ha Noi Address : M Floor, Huy Minh Building, Ly Tu Trong Street, Ben Nghe Ward, Dist 1, HCM City Tel : (+84) 083-9390-882 Fax : (+84) 083-9390-869 Warehouse: Khai Hoan Joint Stock Company, Road No 7, Tam Phuoc Industrial Park, Tam Phuoc, Dong Nai 44 ... TNHH NIKKEN INTERNATIONAL ASIA Exclusive member of NKL scaffold system (ø42.7) NIKKEN RENTACOM GROUP NIKKEN RENTACOM CO.,LTD NIKKEN LEASE KOGYO-MANILA BRANCH NIKKEN INTERNATIONAL MYANMAR 10 NIKKEN. .. SUPPORT CÔNG TY TNHH NIKKEN INTERNATIONAL ASIA SYSTEM NK SUPPORT CÔNG TY TNHH NIKKEN INTERNATIONAL ASIA SYSTEM CÔNG TY TNHH NIKKEN INTERNATIONAL ASIA NK SUPPORT CÔNG TY TNHH NIKKEN INTERNATIONAL... 30.5 43 Φ9 768.3 Φ4 43 60.35 Φ L3 NIKKEN INTERNATIONAL ASIA CO.,LTD Exclusive member of NKL scaffold system (Ø42.7) Set up stair Repeat the same steps as above NIKKEN INTERNATIONAL ASIA CO.,LTD

Ngày đăng: 03/11/2019, 08:27

TỪ KHÓA LIÊN QUAN

w