Cooling • Refrigeration • Condition as a refrigerant - Low boiling point - Latent heat evaporated of the refrigerant should be high - Pressure condensed should be low properly - The va
Trang 2▶ FATC CONTROL PANEL
▶ FATC CONTROL LOGIC
▶ FATC SELF-DIAGNOSIS
▶ A/C DIAGNOSIS
▶ A/C TROUBLESHOOTING
Trang 3Generation information
• Heat transfer
• Heat-transfer is developed the thermodynamics laws of
conduction, radiation, and convection.
• Conduction • Radiation
Trang 5Water Temperature Above 100 ℃.
Water is not boiled.
Pressure Cap Installed Pressure Cap Removed
Trang 6Removing Heat
Absorbing Heat
Trang 7Cooling
• Refrigeration
• Condition as a refrigerant
- Low boiling point
- Latent heat evaporated of the refrigerant should be high
- Pressure condensed should be low properly
- The vapor volume should be small
- The gas vomited of the compressor should be low
- The critical temperature should be enough high
- Low corrosion
- Non – conductor
Trang 9Cooling
• Refrigeration
• Expression formula of refrigerant
A number in one figure: Fluorine atomic quantity (n)
A number in tenth figures: Hydrogen atomic quantity (n+1)
A number in one hundred figures: Carbon atomic quantity (n-1)
R –
C: n = 2 H: n = 2 F: n = 4
C: n = 1 H: n = 0 F: n = 2 Cl: n = 2
CH 2 FCF 3 CCl 2 F 2
R – 134a (HFC –134a) R-12 (CFC – 12)
Trang 10120.91 102.03
Molecular weight
-29.79 -26.14
Boiling point (1atm,℃)
-155.0 -108.0
Freezing point (℃)
111.8 101.29
Critical temperature (℃)
3.15 kg/㎠ (0℃) 2.98 kg/㎠ (0℃)
Saturated vapor pressure
15.51 kg/㎠ (60℃) 17.11 kg/㎠ (60℃)
36.43 kcal/㎠ (0℃)
47.04 kcal/㎠ (0℃) Evaporation latent heat
No No
Inflammability
95~150 Year 8~11 Year
Remaining time in the atmosphere
Good Bad
Mineral oil solubility
No Possible (burning)
Toxicity
27.33 kcal/㎠ (60℃) 33.18 kcal/㎠ (60℃)
R-12 R-134a
REFRIGERANT
Trang 11Cooling cycle
• There are 4 operations of the cooling cycle.
Blower Motor Evaporator
Expansion Valve Heat absorbed
Compressor Condenser
Heat removed
Receiver Drier
Trang 122 The liquid refrigerant transferred from the expansion valve within the evaporator and the vapor of the refrigerant is existed
Trang 133 It is so called a condensed heat The heat emitted at the higher temperature from the refrigerant of high temperature, high pressure that counted the heat when being condensed.
Trang 15Components of air conditioner
• Compressor(swash plate type)
• Function : suction, compress, pumping
Trang 16Components of air conditioner
Discharge valve
Valve plate Suction valve
Piston
Swash plate
Shaft seal
Shaft Ball
• Compressor(swash plate type)
Trang 17Components of air conditioner
SUCTION & DISCHARGE STROKE
Trang 18Discharge
valve
Trang 19Components of air conditioner
• Magnetic clutch
Compressor Compressor
• Function : Magnetic clutch turns on and delivers engine power
to compressor.
• Operation
a) When current is flowing to magnetic coil (ON)
- Pulley assembly and clutch pad are connected each other.
b) When current isn’t flowing to magnetic coil (OFF)
- Pulley assembly and clutch pad are not connected each other.
Trang 20Components of air conditioner
• Safety valve (Pressure Relief Valve)
Release the high pressurized refrigerant and oil
- Operating pressure: 35.3~42.2kg/㎠
Trang 21Components of air conditioner
• Belt lock safety function
• Function : When developing the engine, 1- belt type is mainly
applied to reduce the loss of the power If the inner of the A/con
compressor connected to 1-belt is stick or occurred the clutch
slip, the belt can be cut.
Trang 22Components of air conditioner
• Condenser
R-134A, PARALLEL FLOW TYPE
Trang 23Components of air conditioner
• Receiver drier
3) VAPOR BUBBLE SEPARATION
2) REFRIGERANT STORAGE
Vapor Liquid
DESICCANT
FILTER PAD FILTER PAD
FUNCTION
1) REFRIGERANT PURIFICATION
Trang 25Components of air conditioner
• Pressure switch
• 1 Low pressure: If there is no refrigerant in the A/con system,
open the s/w, cut to be supplied the power into the compressor
clutch
• 2 High pressure: If the pressure is higher than the normal,
open the s/w and cut to be supplied the power
(Normal condition) (High-pressure switch operation)
Trang 26Components of air conditioner
• Triple pressure switch
MEDIUM (3) MEDIUM (4)
LOW & HIGH (1) LOW & HIGH (2)
MEDIUM
(1) (3) (4) (2)
ELECTRIC DIAGRAM
Low & high switch : Compressor control
Middle switch : Condenser fan control
HIGH
MIDDLE
LOW
ECM
Trang 27Components of air conditioner
• Triple pressure switch
ON
ON ON ON
OFF
OFF 2.3 ~ 15.5
Pressure decreasing Pressure decreasing Excessive pressure
1 COMPRESSOR & CONDENSER FAN CONTROL TABLE
Trang 28Components of air conditioner
• LOW & HIGH SWITCH (kg/cm2)
(Middle switch)
Trang 29Components of air conditioner
• Expansion valve
• Function : The purpose of the expansion valve is to allow
high-pressure liquid to expand as it enters the evaporator
Trang 30Components of air conditioner
• Evaporator
• Function : The cold refrigerant passes through the coils of the
evaporator, which vaporizes and absorbs heat from the
passenger compartment
Trang 32Components of air conditioner
• Thermostat
• Operation : It is connected to the magnetic clutch of the
compressor in series It disengages the magnetic clutch when
the evaporator fins surface temperature is below about 0±1℃.
Trang 33Components of air conditioner
• Heater unit
• Function : The heat from the coolant is transferred to the
passenger compartment through the heater core
Trang 34HEATER CORE FLOOR
Trang 35HEATER CORE FLOOR
(MAX COOL)
Trang 36Filter replacement period is 5000 ~ 12,000km But this can be shorten if
the road condition is bad causing more dust and black smoke in the air
3 HOW TO REPLACE
① Remove the glove box
② Pull the locking part of the air
filter cover
Air filter cover
Trang 38- current : 18.3 ±1.3a (max)
④ Temperature range in use : -30℃ ~ 80 ℃
Trang 39FATC INPUT & OUTPUT
CONTROL MODULE
CONTROL MODULE
ECM
MIX DOOR MODE DOOR
COMPRESSOR
BLOWER SPEED
INTAKE ACTUATOR AQS CONTROL
INTAKE ACTUATOR
Trang 40SYSTEM LOCATION
A/C Relay, Blower Relay (Junction Box)
Hi Speed Blower Relay
In-car Sensor &
Trang 41BLOWER SPEED CONTROL DEVICE
1 POWER TR
① INSTALL LOCATION
Trang 42BLOWER SPEED CONTROL DEVICE
② POWER TR AND PIN ASSIGNMENT
COLLECTOR
Trang 43* CODITION: IG ON, FATC ON
③ POWER TR INSPECTION METHOD 1
BLOWER SPEED CONTROL DEVICE
B+
6
10.5 ± 0.5 5
9.0 ± 0.5 4
7.3 ± 0.5 3
5.6 ± 0.5 2
4.0 ± 0.5 1
VOLTAGE(V) BLOWER
SPEED
Trang 44④ POWER TR INSPECTION METHOD 2
* CODITION: IG ON, FATC OFF
Measure voltage:
Variable (up/down blower speed switch)
* CAUTION: Do not pull off the TR during blower operation.
BLOWER SPEED CONTROL DEVICE
Trang 45BLOWER SPEED CONTROL DEVICE
2 HIGH SPEED BLOWER RELAY
INSTALL LOCATION
HI SPEED BLOWR RELAY
Trang 46V * Check the voltage pressing the intake switch
Trang 47TEMP DOOR ACTUATOR
TEMP DOOR ACTUATOR is located in the bottom of the heater unit The actuator controls the position of the temperature blend door based on the
voltage signal from the FATC module Potentiometer inside actuator sends a feedback signal to the controller and controller cuts off the voltage signal
coming from the controller when the required door position is achieved
Trang 49I C
5 4 3 2 1
G + + + + + G + + + + + G + + + + + G + + + + + G
MODE
VENT Bi-LEV FLOOR
M I X DEF
VENT (A12) BI-LEVEL (A2)
FLOOR (A13) MIX (A3) DEF (A14)
Trang 50FIN SENSOR
1 DESCRIPTION
Fin sensor is installed in the evaporator in order to detect the temperature
of evaporator It prevents evaporator from freezing
2 FIN SENSOR
① LOCATION
: inserted into the evaporator pin
3 2 1
Trang 51FIN SENSOR
② CHARACTERISTICS OF FIN SENSOR
③ ON/OFF TEMPERATURE: 0 ~ 0.5℃ OFF
Trang 52FATC CONTROL MODULE
Trang 53INCAR SENSOR
The in-car sensor is located on the lower crash pad as shown in the picture
It contains a thermister, which measures the temperature of the air inside
the passenger compartment It senses the passenger compartment
temperature, changes the resistance value, and enters the corresponding
voltage into the automatic temperature control module (FATC)
Trang 55PHOTO SENSOR
The photo sensor is located on the left side of crash pad assembly
It contains a photovoltaic (sensitive to sunlight) diode
Characteristics of photo sensor
Trang 56PHOTO SENSOR (FATC)
+ -
Trang 57AMBIENT SENSOR
The ambient temperature sensor is located in front of the condenser fan
shroud This sensor detects the temperature of outside air and sends
voltage signals to the controller
Trang 58(B7) (A7)
Trang 60AQS (FATC OPTION:DOMESTIC AREA ONLY)
The Air Quality System detects exhaust gas of neighboring vehicles and
intercepts automatically AQS controls the inlet of car automatically and can be easily installed to the existing vehicle Manual operation is also available
9 ~ 16V DC 12V DC -30 ~ 105℃
less 1 sec Reaction time
Detectable gas
SPECIFICATION Operating voltage
Rated voltage Operating temperature
Trang 61AQS (FATC OPTION:DOMESTIC AREA ONLY)
* LOCATION: In front of condenser
* AQS SWITCH
Trang 62FATC CONTROL MODULE
- Normal → 5V
- Gas detected → 0V
AQS
Trang 63HUMIDITY SENSOR
LOCATION: Lower Crash Pad
Trang 64HUMIDITY SENSOR
Humidity sensor detects the relative humidity of the car’s cabin This sensor converts it into the voltage signal and sends the signal to the FATC controller
HUMIDITY VOLTAGE (V) HUMIDITY VOLTAGE (V)
Trang 665) Humidity range: below 99% RH(Relative Humidity)
6) Terminals: 3 terminals ( DC 5V, Ground, Sensor output)
3 Block Diagram
HUMIDITY SENSOR
Trang 67CONTROL PANNEL (FATC, AQS)
AQS switch
Fre/Rec switch
Ambient temperature check switch
A/C ON/OFF switch
Defrost switch
Blower speed
up/down switch
A/C AUTO switch System OFF switch
Mode switch
Temperature up/down switch
1 FATC WITH AQS
Trang 68CONTROL PANNEL (FATC,NON AQS)
2 FATC WITHOUT AQS
Trang 69TEMPERATURE UNIT CHANGE
* Setting unit: ℃ (Battery disconnection)
Temp unit change: ℃ ℉
Trang 70* Setting unit: ℃ (Battery disconnection)
Temp unit change: ℃ ℉
Trang 71- SYSTEM OFF or MANUAL STATE ▶ AUTO SW
▶ A/C SYSTEM AUTOMATICALLY CONTROLLED
- MODE DOOR: DEF MODE
- A/C: ON
- INTAKE DOOR: FRESH MODE
- OTHERS: SAME STATE AS BEFORE 'OFF' '- A/C ON
- A/C OFF (IF PUSH THE SWITCH AGAIN)
Trang 72CONTROL PANNEL SWITCH FUNCTION
FUNCTION
- SYSTEM OFF: BLOWER, COMPRESSOR OFF
- TEMP DOOR: AUTOMATICALLY CONTROLLED
- MODE DOOR:
▶ AUTO CONTROL (IF 'AUTO' BEFORE 'OFF') ▶ SAME POSITION (IF 'MANUAL' BEFORE 'OFF')
- INTAKE DOOR ▶ REC (IF 'AUTO' BEFORE 'OFF') ▶ SAME POSITION (IF 'MANUAL' BEFORE 'OFF')
Trang 741 In-car temperature correction
When the in-car sensor detects a sudden steep temperature change,
controller corrects the temperature differences slowly
- 1℃ up / 4sec delay
- 1℃ down / 4sec delay
2 Ambient temperature correction
When the ambient sensor detects a sudden steep temperature change,
controller corrects the temperature differences slowly
- 1℃ up / 3 min delay (ex Underground, tunnel)
- 1℃ down / 4sec delay
CONTROL LOGIC
Trang 753 Heat radiation correction
When the photo sensor detects a sudden steep solar radiation change,
controller compensates it slowly
- 350 → 1000 (W/m2) / 1 min delay
- 350 ← 1000 (W/m2) / 5 min delay
4 Temp door control
Temp door angle (0% ~ 100%) is automatically controlled according to
the selected temperature and other sensor signals
: Available selected temperature range
- MAX COOL: 17℃
- MAX HOT: 32℃
- 17℃ ↔ 32℃, 0.5℃ step (62℉ ↔ 90℉, 1℉ step)
CONTROL LOGIC
Trang 765 Blower speed control
- AUTO mode: linear control
- MANUAL mode: 7 step control
6 Mode control
- AUTO: Mode changes automatically according to the selected
temperature and other sensor signals
- Manual: Mode changes when the mode switch is selected
VENT → B/L → FLOOR → MIX → VENTCONTROL LOGIC
Trang 777 Intake door mode
- The FRE/REC door state can be changed at AUTO mode according to
the input data combination
8 Compressor ON/OFF control (AUTO mode)
- Fin sensor: lower 0.5℃▶ Compressor OFF
over 3℃▶ Compressor ON
9 MAX HOT function (When 32℃ is selected at AUTO mode)
▶ Temp door: MAX HOT side
▶ Mode door: Floor mode
▶ Intake door: FRE mod
▶ Compressor: OFF
▶ Blower speed: MAX high
CONTROL LOGIC
Trang 7810 MAX COOL function (When 17℃is selected at AUTO mode)
▶ Temp door: MAX COOL side
▶ Mode door: VENT mode
▶ Intake door: REC mode
• AUTO low: 12 seconds
• AUTO low ▶ AUTO high:
30 secondsCONTROL
11 WARM AIR PREVENTION FUNCTION (Initial A/C operation)
Trang 79A 60 seconds
Ambient Temp (℃) Time (A)
Trang 80SELF DIAGNOSIS
Ignition switch : OFF→ON Setting Temp : 25 ℃
Press the Mode S/W more than 3 times within 5 seconds during
pressing the A/C switch
Return to original condition
All graphics on the display blinks 2 times per 0.5seconds and the
“dcc” character on the setup temperature display panel blinks 2
times per 0.5 seconds, starts self diagnosis.
DTC code turns on/off per 1 second periodically.
If DTC codes are two or more than, each DTC code blinks 2 times
over again.
• Case 1
Trang 81SELF DIAGNOSIS
• Case 2
Trang 82-• Case 1