Daikin skyair ga R 22 dieuhoa thuongmai

24 288 2
Daikin skyair ga R 22 dieuhoa thuongmai

Đang tải... (xem toàn văn)

Tài liệu hạn chế xem trước, để xem đầy đủ mời bạn chọn Tải xuống

Thông tin tài liệu

Daikin skyair ga R 22 dieuhoa thuongmai tài liệu, giáo án, bài giảng , luận văn, luận án, đồ án, bài tập lớn về tất cả c...

PCS0911A AIR CONDITIONING SYSTEM COOLING ONLY [50Hz ] The match for tastefully designed offices and stores P eo pl e ar e dr aw n to b e a u tifu lly d e sig n e d stores that ex pres s the lates t People work bes t in offices i m bued w i t h f unc tio n a l b e a u ty Dai ki n’s SkyAi r i s th e ch o ice to b rin g h ig h quality air c onditioning to s tores and offic es lik e this T nks t o i t s man y a d va n ta g e s su ch a s q u iet operation, eas e of us e and flex ible ins tallation, the SkyAir enj o ys an excel l e n t re p u ta tio n th ro u g h o u t the world wherev er it is us ed Cooling only HP Capacity * Btu/h kW The values given for HP–6 HP is for FHC type, 6.5 HP–7 HP is for FDMG type kcal/h 2.5 3.5 18,000 21,000 26,000 30,000 5.3 6.2 7.6 8.8 4,560 5,290 6,550 7,570 FHC18NUV1 FHC21NUV1 FHC26NUV1 FHC30NUV1 R18NUV1 R21NUV1 R26NUV1 / Y1 R30NUV1 / Y1 CEILING MOUNTED CASSETTE TYPE Indoor unit Outdoor unit CEILING SUSPENDED TYPE FH21NUV1 FH26NUV1 FH30NUV1 R21NUV1 R26NUV1 / Y1 R30NUV1 / Y1 FDBG18PUV1 FDBG21PUV1 FDBG26PUV1 R18NUV1 R21NUV1 R26NUV1 / Y1 Indoor unit Outdoor unit LOW STATIC PRESSURE TYPE Indoor unit Outdoor unit DUCT CONNECTION MIDDLE STATIC PRESSURE TYPE Indoor unit Outdoor unit Indoor unit Outdoor unit FDMG26PUV1 FDMG30PUV1 R26NUV1 / Y1 R30NUV1 / Y1 FDMG26NUV1 FDMG30NUV1 R26NUV1 / Y1 R30NUV1 / Y1 R26NUV1 / Y1 R30NUV1 / Y1 OUTDOOR UNIT R18NUV1 R21NUV1 *1 Note : Rated cooling capacities are based on the following conditions: Return air temp., 27°CDB, 19.0°CWB; outdoor temp 35°CDB Equiv refrigeration piping, 7.5 m (horizontal) CEILING SUSPENDED TYPE Simple design and quiet operation auto-swing air flow brings comfort to each and every corner of the room Installation and maintenance are easy CEILING MOUNTED CASSETTE TYPE DUCT CONNECTION TYPE The Theindoor indoorunit unitisisinstall instaled led inside insidethe theceiling ceilingand andduc d uctsts discharge dischargeair airininany anydirec direction tion Comfort Comfortisisprovided providedwithout without even evenknowing knowingthat thatan anair r conditioner conditionerisisinstalled installed Th is u n it is in st a lle d a t center Thilin is gu.n A it irisisinbstloawn lle dina tfour center ce ce ilin g A ir is b lo wn in four d ire ct io n s t o b rin g co mfort cttio t o qburin Odpire e ionns is ie tg co mfort O p e t io n is q u ie t 6.5 36,000 42,000 48,000 51,000 56,000 10.6 12.3 14.1 15.0 16.4 9,100 10,600 12,100 12,900 14,100 FHC36NUV1 FHC42NUV1 FHC48NUV1 R36NUV1 / Y1 R42NUY1 R48NUY1 FH36NUV1 FH42NUV1 FH48NUV1 R36NUV1 / Y1 R42NUY1 R48NUY1 FDMG36PUV1 FDMG42PUV1 FDMG48PUV1 FDMG51PUV1 FDMG56PUV1 R36NUV1 / Y1 R42NUY1 R48NUY1 R51NUY1 R56NUY1 FDMG36NUV1 FDMG42NUV1 FDMG48NUV1 FDMG51NUV1 FDMG56NUV1 R36NUV1 / Y1 R42NUY1 R48NUY1 R51NUY1 R56NUY1 R36NUV1 / Y1 R42NUY1 R48NUY1 R51NUY1 R56NUY1 CEILING MOUNTED FHC-NU CASSETTE TYPE Quiet, decor-blending form and easy installation Sound level 42/36 Cooling only dB(A) High FHC18NU–48NU Low FHC36NU (220V) Option Accessory required for indoor unit Wired LCD remote controller BRC1C61 Note: Remote controller cable not included Cables must be procured locally Wireless LCD remote controller A signal receiver must be added to the indoor unit BRC7C613W Signal receiver unit (Installed type) Wireless remote controller and signal receiver unit are sold as a set Features Fresh air intake kit Long-life filter PE fin *2 High-efficiency filter • Ultra long-life filter • Auto-restart • Others Ceiling soiling prevention *1 Options Filter sign • Pre charged for up to 15 m • Drain pump mechanism High ceiling application • Mould resistant treatment for filter Programme "Dry" • Control features Work & Servicing Timer selector Switchable fan speed • *1Applicable when wired remote controller is used *2Applicable to R36NU–R48NU outdoor units Two selectable temperature-sensors Swing pattern selection Cooling only Auto swing Model Mould prevention Comfort Feature • • • • • • • • Compact body and quiet operation All models from the 18NU to 48NU use the same size panel Multiple unit installations maintain a physical uniformity that is aesthetically pleasing and make it easier to plan ceiling lighting systems and to design interiors Indoor units use an aerodynamically designed Diffuser Turbo Fan 950 mm Unified square panels Draft resistance has been reduced by incorporating, into a single unit, an impeller and a diffuser to control air flow inside the unit The Diffuser Turbo Fan is both quiet during operation and compact Diffuser (220V) dB(A) Same for all models Blade 950 mm Optimal comfort and convenience assured by air discharge modes Air direction Desired situation Draft prevention setting When drafts are unwanted Standard setting Setting to prevent soiling of ceiling For gentle drafts(Ceiling is soiled.) When ceilings must be kept spotless Auto-swing Auto-swing between 10° and 40° Auto-swing between 10° and 65° Auto-swing between 30° and 65° 5-levels air direction setting Settable to different levels between 10° and 40° Settable to different levels between 10° and 65° Settable to different levels between 30° and 65° Draft prevention (In heating mode) At heating startup and thermo OFF*, air discharge is automatically set to a near horizontal 10˚ to prevent direct exposure to cool air drafts Auto air direction control The air direction is set automatically to the memorised position of the previous air direction (Initial setting is 65˚ for heating and 30˚ for cooling.) At heating startup and thermo OFF*, air discharge is automatically set to 30˚ to prevent both direct exposure to cool air drafts and contact with ceilings *When the thermostat turns off 4-way flow pattern 3-way flow pattern Wide air distribution Air discharge opening increases flow without increasing wind speed, hence discharged air reaches farther than before Air discharge distribution comparison •42NU 2-way flow pattern Note: For 3-way or 2-way flow installation, the sealing member for air discharge outlet (option) must be used to close off the unused outlet(s) Air direction can be selected according to installation Note: Operation sound increases when using 2-way or 3-way flow Two selectable temperature-sensors Both indoor unit and wired remote controller (option) contain temperaturesensors Temperature sensing can be set at the unit or, to further improve comfort level, closer to the target area at the wired remote control.This feature require initial setting by the installer (m) (m) 3.2 Super Cassette (m) Conventional model 2.7 2.5 m/sec 2.0 m/sec 1.5 m/sec 1.0 m/sec 2.5 m/sec 2.0 m/sec 1.5 m/sec 1.0 m/sec 0.5 m/sec 0.5 m/sec " " denotes piping direction " " denotes sealing member for air discharge outlet (option) High Low 18NU 21NU 26NU 30NU 36NU 42NU 48NU 33 35 35 39 42 42 42 29 30 30 34 36 36 36 Quick and easy to install Just 240 mm high Installable in tight ceiling spaces (18NU–26NU) 240 mm *1 245 mm *2 *1 298 mm high with 30NU–48NU *2 303 mm high with 30NU–48NU Easy height adjustment Note: Air direction is set to the standard position when the unit is shipped from the factory The position can be changed from the remote controller Multi-Flow System Indoor unit 1 (m) Each corner of the unit has an Adjuster Pocket that lets you easily adjust the unit's suspended height Note: If the wireless remote control option is installed, a light receptor unit is housed in one of the adjuster pockets All models suspended without lift Installable in any direction Suitable for high ceilings Criteria for ceiling height and number of air discharge outlets Number of air discharge outlets used 18NU–26NU 4-way flow Standard Ceiling High ceiling height High ceiling 3-way flow 2-way flow 30NU–48NU 4-way flow 3-way flow 2-way flow 2.7 m 3.0 m 3.5 m 3.2 m 3.6 m 4.2 m 3.0 m 3.3 m 3.8 m 3.6 m 4.0 m 4.2 m 3.5 m 3.5 m 4.2 m 4.2 m - Note: Initial settings are for standard ceiling height and 4-way flow High ceiling settings and are set from the remote controller Provided with drain pump mechanism 750 mm Programme "Dry" Dehumidification is microprocessor controlled to prevent abrupt and uncomfortable changes in air temperature Switchable fan speed: High/Low Easy installation of options The high-performance filter and other options are easily clipped into place There is no need for a screwdriver *Temperature-sensor on indoor unit must be used when the air conditioner is controlled from another room **Wireless remote controller does not have a temperature-sensor CEILING SUSPENDED TYPE FH-NU Upgrade to a quiet and compact system Sound level 46/40 Cooling only High FH21NU–48NU dB(A) Low FH36NU (220V) Option Accessory required for indoor unit Wired LCD remote controller BRC1NU61 Note: Remote controller cable not included Cables must be procured locally Wireless LCD remote controller A signal receiver must be added to the indoor unit BRC7NU66 Signal receiver unit (Installed type) Wireless remote controller and signal receiver unit are sold as a set Features Mould resistant treatment for filter Mould proofing drain pan Pre charged for up to 15 m • • • • *1 Others PE fin Timer selector • Options Long-life filter Programme "Dry" • *1Applicable to R36NU–R48NU outdoor units Control features Auto-restart Switchable fan speed Cooling only Work & Servicing Auto swing Model Mould prevention Comfort Feature • • • Spreads comfortable air throughout the room Auto-swing (up&down) brings comfort to the room Wide air discharge openings produce a spreading 100° airflow Installable on ceilings 3.5 m high Switchable fan speed: High/Middle/Low Quiet operation Sound operation has been reduced on the exposed ceiling suspended type unit (220V) dB(A) Indoor unit High Low 21NU 44 44 45 46 48 49 40 40 40 40 42 43 26NU 30NU 36NU 42NU Programme "Dry" Dehumidification is microprocessor controlled to prevent abrupt and uncomfortable changes in air temperature 100° Air is blown up to 50° in the downward direction Installation flexibility for freedom of design Uniform height and depth Compact design for smallcapacity models to meet tighter dimensional constraints (mm) Indoor unit 21NU 26NU 30NU 36NU 42NU 48NU 195 1,160 1,400 Uses quiet stream fan and other quiet technologies Turbulent flow Straightening is produced vane 50° Height Width Depth 48NU Note : Anechoic chamber conversion value, measured according to JIS parameters and criteria 1,590 680 Weight of all models reduced (down 10% compared with previous models) Transfer and installation work is less arduous Reduced edge space, flexible installation All wiring and internal servicing done from below the unit Pipes more easily rigged, too Plastic panels are used to conceal piping holes Holes can be easily punched out without requiring special tools Quiet stream fan Easier to maintain Long-life filter lasts about half year * maintenance not required * For dust concentration of 0.15 mg/m3 Non-dew flap without bristles Absence of bristles minimises clinging dirt and simplifies cleaning Non-dew flap Easy-clean, flat surfaces It is easy to wipe dirt off the flat side and lower surfaces of the unit For all maintenance tasks, access is from bottom surface The unit fits more snugly into tight spaces For 48NU indoor unit 30 mm or more 1,590 mm 30 mm or more *Water used in the test-run can now be drained from the air discharge opening rather than from the side as was formerly the case Improved-oil resistant grille Oil-resistant plastic is used for the air discharge grille This improves durability in restaurants and other similar environments Note: Intended for use in salons, dining rooms, and ordinary sales floors, this specification is not suitable for kitchens or other harsh environments FDMG-PU FDMG-NU DUCT CONNECTION MIDDLE STATIC PRESSURE TYPE Unit can be mounted in the ceiling and air can be delivered freely by duct Superior freedom of layout The duct system allows the efficient location of discharge outlets in accordance with the room layout Middle static pressure type, usable in a larger than standard space Duct connection is simpler with standard rear intake chambers Ordinary duct (procured locally) Air conditioner 295 mm Ordinary duct (procured locally) 305 mm or more Air intake Air discharge Quiet operation (220V) dB(A) FDMG36PU Sound level Cooling only FDMG26PU–56PU FDMG26NU–56NU 45/37dB(A) High LOW 42 44 45 46 46 47 47 38 36 37 37 37 37 37 FDMG36PU Low FDMG42PU FDMG36PU FDMG48PU FDMG51PU Accessory required for indoor unit FDMG56PU For FDMG-PU Wired LCD remote controller High FDMG30PU (220V) Option Indoor unit FDMG26PU Switchable fan speed: High/Middle/Low (FDMG26NU–56NU) (FDMG26PU–56PU is switchable fan speed: High/Low) Signal receiver unit (Separate type) Wireless remote controller and signal receiver unit are sold as a set Model For FDMG-NU Cooling only Digital remote controller Remote controller KRC47-2A KRC47-1A • *1 *2 *1Applicable when wired remote controller is used (FDMG-PU) *2Applicable to R36NU–R51NU outdoor units Others PE fin BRC4C64 Work & Servicing Control features Comfort Feature Auto-restart A signal receiver must be added to the indoor unit Features Pre charged for up to 15 m Wireless LCD remote controller Drain pipe connection can be done inside the unit Coolant and drain pipe outlets are at the same opening Two selectable temperature-sensors Note: Remote controller cable not included Cables must be procured locally Switchable fan speed BRC1C61 • • DUCT CONNECTION FDBG-PU LOW STATIC PRESSURE TYPE Ideal for quiet, beautiful living spaces Suitable for condominiums and apartments, houses and hotels Compact Small, lightweight, and easy-to-install indoor unit or more Suction chamber Air filter [Duct connection] To prevent increased operation sound, avoid installing the air suction grille directly below the suction chamber Quiet operation Sound level Cooling only FDBG18PU–26PU 43/40dB(A) High Indoor unit High Low FDBG18PU 41 43 43 38 40 40 FDBG21PU Low FDBG26PU FDBG26PU (220V) dB(A) (220V) Accessory required for indoor unit Features Cooling only A signal receiver must be added to the indoor unit BRC4C64 • *1 PE fin Model Wireless LCD remote controller Others Auto-restart Note: Remote controller cable not included Cables must be procured locally Two selectable temperature-sensors BRC1C61 Work & Servicing Control features Comfort Feature Pre charged for up to 10 m Wired LCD remote controller Switchable fan speed Option • • • *1Applicable when wired remote controller is used Signal receiver unit (Separate type) Wireless remote controller and signal receiver unit are sold as a set Simultaneous air conditioning of two rooms and ventilation grille (ventilation opening) (This feature also applies to duct connection middle static pressure type.) When air conditioning two rooms simultaneously, the air discharged into each room must be circulated back to the air conditioner To achieve this, a ventilation duct should be installed for each room or one of the indicated ventilation grilles should be installed on the partitioning wall or under the door between the rooms Partitioning wall Door-installed ventilation grille Wall-installed ventilation grille Under-door cutout Ventilation grille Ventilation grille Under-door cutout Ventilates air through the partitioning wall (See right) Note: The under-door cutout method should be used only when there is a small volume of airflow OUTDOOR UNIT R18NU R21NU Quiet Operation Fitted with wide inlet fan (Applies to R26NU–51NU) Fully shaped aerodynamic propellers are designed to push air with a large wing Wide inlet fan surface This provides both high blow volume and quiet operation with minimal turbulence R26/30NU R36NU Slim-design and low-profile compact outdoor units Pre charged for up to 15 metres (Applies to R36NU–51NU) (Applies to R26NU–51NU) If refrigerant piping length does not exceed 5m (R56NU), 10m (R18NU,R21NU, R26NU), 15m (R36NU, R42NU, R48NU, R51NU), there is no need for on-site gas charging Compactly designed outdoor unit with interior layout optimised for the smooth airflow Allowed refrigerant pipe length and level difference Curved Super Aero Grille restricts the spread of exhaust gas and fits in the same space as conventional outdoor units Smooth running, minimal vibration, low operating sound (Equivalent length 50 m) R21NU 10 m (Equivalent length 50 m) R26NU 10 m (Equivalent length 50 m) 10 m 15 m 15 m 500 30 m 15 m 30 m 15 m 30 m 20m 30 m 20m 30 m 20 m 30 m 20 m 30 m (Equivalent length 50 m) (Equivalent length 50 m) (Equivalent length 50 m) R48NU 15 m (Equivalent length 50 m) 20 m R51NU 15 m 30 m (Equivalent length 50 m) 20 m R56NU 5m (Equivalent length 70 m) 50 m 30 m (mm) (Applies to R26NU–36NU) Max level difference Note: 1Additional refrigerant charging is required if the refrigerant pipe is longer than the length 4-direction piping offers greater layout freedom (Applies to R26NU–56NU) Piping can be run from the front, bottom, right or rear surface according to how the unit is installed Takes installation environment into consideration Even less operation sound (In case of V1: 220V, Y1: 380V) dB(A) 10 m R42NU (Applies to R36NU–56NU) Outdoor unit Sound level R18NUV1 49 54 57 55 57 59 59 R51NUY1 R18NU 50 Equipped with scroll compressor for quiet operation R48NUY1 Max length R36NU To suppress turbulence and achieve quiet operation, the curved ribs of the grille are optimised to meet the outflow of air R42NUY1 Pre charged *1 R30NU (Applies to R26NU–51NU) R30NUV1 R30NUY1 R36NUV1 R36NUY1 R48/51NU Installation and maintenance Compact Fitted with Super Aero Grille R21NUV1 R42NU Durability Heat exchange fins provided with anti-corrosion treatment To achieve increased durability by improved resistance to salt corrosion and atmospheric pollution, coated PE fins (with special acryl pretreatment) are used for the heat exchanger of the outdoor unit Construction Non-treated fin Aluminium PE fin Hydrophilic film Aluminium Corrosion resistant acrylic resin Abundance of functions that provide comfortable air-conditioning in stores and offices See the list of main functions given on the page introducing each indoor unit Work and Servicing Comfort Drain pump mechanism Auto-swing Delivers comfortable airconditioning to all areas, near to and far from the airconditioner Air discharge direction angle can be set (fixed setting) Steeper gradient realises more efficient condensate drainage High-lift is especially useful for long lengths of drain piping Pre charged for up to 15 metres Swing pattern selection If refrigerant piping length does not exceed 15 m, there is no need for on-site gas charging (Applies to R36NU–51NU) (draft prevention, standard, ceiling soiling prevention) You can freely set air discharge positions by remote controller (1) Air direction range in standard position (2) Air direction range in draft prevention position Ceiling soiling prevention function Daikin's innovative air discharge mechanism keeps airflow away from the ceiling Ceiling cleaning is less frequently required Filter sign The filter sign warns you when it is time to clean the filter (3) Air direction range in ceiling soiling prevention position Switchable fan speed High setting provides maximum reach while low setting minimises drafts Programme "Dry" Dehumidification is microprocessor controlled to prevent abrupt and uncomfortable changes in air temperature Useful for reducing uncomfortable humidity without uncomfortable cooling of the room High-ceiling application Delivers air-conditioning comfort all the way down to the floor in air-conditioning zones with high ceilings *When using a wired remote controller the sign is displayed in the LCD When using a wireless remote controller the filter sign lamp illuminates on the signal receiver unit Control features Auto-restart If there is a power outage while the equipment is operating, operations will restart in the same mode as before the power cut when electricity is restored Others PE fin To achieve increased durability by improved resistance to salt corrosion and atmospheric pollution, coated PE fins (with special acryl pretreatment) are used for the heat exchanger of the outdoor unit In high corrosive areas, regular maintenance needs to be carried out Options Note:When units are installed on high ceilings, depending on the model, various restrictions concerning maximum height, air discharge direction, and choice of options may apply Timer selector Operation starts when the preset time of the ON timer elapses and stops when the preset time of the OFF timer elapses High-efficiency filter unit Two types are available: 65% and 90% colorimetry Ultra long-life filter Requires no maintenance for about years* (10,000 h) in stores and offices * For dust concentration of 0.15 mg/m3 Long-life filter Mould prevention Mould resistant treatment for filter Sanitary filter has mould resistant treatment Mould proofing drain pan Mould proofing maintains hygiene by preventing growth in highly humid conditions Maintenance is not required for one year (two years when a ceiling mounted cassette type is used) Fresh-air intake kit You can provide air-conditioning with fresh air from outside Convenient for places where a ventilation fan cannot be installed Note: *Connecting ducts, insect nets, fire dampers, air filters, and other parts should, as required, be procured locally **Outside Air fan interlocked with air conditioning unit is necessary Optional PCB(KRP1C63)is required for interlocking ***It is recommended that the volume of outdoor air introduced through the kit is limited to 10% of the maximum airflow rate of the indoor unit Introducing higher quantities will increase the operating noise and may also influence temperature sending 10 CEILING MOUNTED CASSETTE TYPE Outdoor unit Power supply Cooling capacity 1a/1b Btu/h kW kcal/h kW Power consumption 1a/1b Colour Indoor unit Outdoor unit Unit Decoration panel m3/min Airflow rate (H/L) cfm Sound level (H/L) (220V) dB(A) mm Dimensions Unit (HXWXD) mm Decoration panel kg Unit Machine weight kg Decoration panel °CWB Operation range Colour Compressor Type Motor output kW Refrigerant charge (R-22) Sound level 2, Dimensions (HXWXD) Machine weight Operation range Liquid (Flare) Piping connections Gas (Flare) Drain Indoor unit Outdoor unit Max interunit piping length Max installation level difference Heat insulation 30 26 48 36 42 FHC30NUV1 FHC26NUV1 FHC48NUV1 FHC36NUV1 FHC42NUV1 R30NUV1 R26NUV1 R36NUV1 R48NUY1 R42NUY1 R18NUV1 R21NUV1 R30NUY1 R26NUY1 R36NUY1 V1: Phase, 220–240 V, 50 Hz Y1: Phase, 380–415 V, 50 Hz 18,100/18,000 21,200/21,000 26,300/26,000 30,400/30,000 36,500/36,000 42,700/42,000 49,100/48,000 5.3/5.3 6.2/6.2 7.7/7.6 8.9/8.8 10.7/10.6 12.5/12.3 14.4/14.1 4,580/4,560 5,340/5,290 6,630/6,550 7,670/7,570 9,200/9,100 10,800/10,600 12,400/12,100 2.03/2.02 2.46/2.45 3.07/3.07 3.45/3.45 4.04/4.04 4.79/4.79 5.49/5.49 -White 15/11 19/14 19/14 28/21 33/24 33/24 33/24 529/388 670/494 670/494 988/741 1,164/847 1,164/847 1,164/847 33/29 35/30 35/30 39/34 42/36 42/36 42/36 230X840X840 230X840X840 230X840X840 288X840X840 288X840X840 288X840X840 288X840X840 40X950X950 40X950X950 40X950X950 40X950X950 40X950X950 40X950X950 40X950X950 28 28 24 24 24 28 28 5 5 5 14 to 28 Ivory white Ivory Hermetically sealed scroll type Hermetically sealed rotary type 4.50 1.7 2.2 2.5 3.00 2.5 3.75 2.6 1.20 1.50 2.3 2.0 2.3 2.4 (Charged for 10 m) (Charged for 10 m) (Charged for 10 m) (Charged for 10 m) (Charged for 15 m) (Charged for 15 m) (Charged for 15 m) 18 FHC18NUV1 Indoor unit Model Name kg 21 FHC21NUV1 59 57 57 49 54 55 57 dB(A) mm 540X750X270 685X800X300 770X900X320 770X900X320 1,170X900X320 1,170X900X320 1,345X900X320 92 kg 42 61 70 (V1), 69 (Y1) 70 (V1), 69 (Y1) 81 (V1), 79 (Y1) 87 °CDB 21 to 46 o/ 9.5 mm o/ 6.4 o/ 6.4 o/ 9.5 o/ 9.5 o/ 9.5 o/ 9.5 o/ 19.1 mm o/ 15.9 o/ 15.9 o/ 15.9 o/ 15.9 o/ 19.1 o/ 19.1 mm I.Do/ 25XO.Do/ 32 I.Do/ 25XO.Do/ 32 I.Do/ 25XO.Do/ 32 I.Do/ 25XO.Do/ 32 I.Do/ 25XO.Do/ 32 I.Do/ 25XO.Do/ 32 I.Do/ 25XO.Do/ 32 mm o/ 26.0 (Hole) o/ 18.0 (Hole) o/ 18.0 (Hole) o/ 26.0 (Hole) o/ 26.0 (Hole) o/ 26.0 (Hole) o/ 26.0 (Hole) 30 (equivalent length 50 m) m 20 m 15 Both liquid and gas piping Note : Rated cooling capacities are based on the following conditions: 1a Indoor temp., 27°CDB, 19.5°CWB; outdoor temp 35°CDB Equiv refrigeration piping, 7.5 m (horizontal) 1b Indoor temp., 27°CDB, 19.0°CWB; outdoor temp 35°CDB Equiv refrigeration piping, 7.5 m (horizontal) Anechoic chamber conversion value, measured according to JIS parameters and criteria During operation these values are somewhat higher owing to ambient conditions In case of V1: 220V, Y1: 380V CEILING SUSPENDED TYPE Outdoor unit Power supply Cooling capacity 1a/1b Power consumption 1a/1b Colour Airflow rate (H/L) Indoor unit Outdoor unit Sound level (H/L) (220V) Dimensions (HXWXD) Machine weight Operation range Colour Compressor Type Motor output Refrigerant charge (R-22) Sound level Dimensions (HXWXD) Machine weight Operation range Piping Liquid (Flare) connections Gas (Flare) Drain Indoor unit Outdoor unit Max interunit piping length Max installation level difference Heat insulation 2, 48 36 42 26 30 FH48NUV1 FH36NUV1 FH42NUV1 FH26NUV1 FH30NUV1 R36NUV1 R26NUV1 R30NUV1 R21NUV1 R42NUY1 R48NUY1 R36NUY1 R26NUY1 R30NUY1 V1: Phase, 220–240 V, 50 Hz Y1: Phase, 380–415 V, 50 Hz 36,500/36,000 30,400/30,000 42,700/42,000 49,100/48,000 21,200/21,000 26,300/26,000 10.7/10.6 8.9/8.8 12.5/12.3 14.4/14.1 6.2/6.2 7.7/7.6 9,200/9,100 7,670/7,570 10,800/10,600 12,400/12,100 5,340/5,290 6,630/6,550 5.50/5.50 2.72/2.71 3.48/3.48 4.06/4.06 4.83/4.83 3.10/3.10 White 42-44/24-26 22-23/9-20 26-27/22-23 32-34/22-24 38-40/23-25 22-23/9-20 776-811/317-706 776-811/317-706 917-953/776-811 1,129-1,200/776-847 1,341-1,412/811-882 1,482-1,553/847-917 49/43 46/40 45/40 48/42 44/40 44/40 195X1,590X680 195X1,400X680 195X1,590X680 195X1,590X680 195X1,160X680 195X1,160X680 35 26 26 32 35 35 14 to 28 Ivory white Ivory Hermetically sealed scroll type Hermetically sealed rotary type 4.50 2.2 2.5 2.5 3.00 3.75 2.6 1.50 2.3 2.3 2.0 2.4 (Charged for 10 m) (Charged for 10 m) (Charged for 10 m) (Charged for 15 m) (Charged for 15 m) (Charged for 15 m) 21 FH21NUV1 Indoor unit Model Name Btu/h kW kcal/h kW m3/min cfm dB(A) mm kg °CWB kW kg dB(A) mm kg °CDB mm mm mm mm m m 54 685X800X300 61 57 770X900X320 70 (V1), 69 (Y1) o/ 6.4 o/ 15.9 I.D o/ 20XO.D o/ 26 o/ 18.0 (Hole) o/ 9.5 o/ 15.9 I.Do/ 20XO.D o/ 26 o/ 26.0 (Hole) 15 Note : Rated cooling capacities are based on the following conditions: 1a Indoor temp., 27°CDB, 19.5°CWB; outdoor temp 35°CDB Equiv refrigeration piping, 7.5 m (horizontal) 1b Indoor temp., 27°CDB, 19.0°CWB; outdoor temp 35°CDB Equiv refrigeration piping, 7.5 m (horizontal) Anechoic chamber conversion value, measured according to JIS parameters and criteria During operation these values are somewhat higher owing to ambient conditions In case of V1: 220V, Y1: 380V 11 57 55 770X900X320 1,170X900X320 70 (V1), 69 (Y1) 81 (V1), 79 (Y1) 21 to 46 o/ 9.5 o/ 9.5 o/ 15.9 o/ 19.1 I.D o/ 20XO.Do/ 26 I.Do/ 20XO.D o/ 26 o/ 26.0 (Hole) o/ 26.0 (Hole) 30 (equivalent length 50 m) 20 Both liquid and gas piping 57 1,170X900X320 87 59 1,345X900X320 92 o/ 9.5 o/ 19.1 I.D o/ 20XO.D o/ 26 o/ 26.0 (Hole) o/ 9.5 o/ 19.1 I.Do/ 20XO.D o/ 26 o/ 26.0 (Hole) DUCT CONNECTION MIDDLE STATIC PRESSURE TYPE Indoor unit Model Name Outdoor unit Power supply Cooling capacity 1a/1b Power consumption 1a/1b Colour Fan Airflow rate (H) Indoor unit Rated external static pressure Sound level (H/L) (220V) Dimensions (HXWXD) Machine weight Operation range Colour Outdoor Compressor Type unit Motor output Refrigerant charge (R-22) Sound level 2, Dimensions (HXWXD) Machine weight Operation range Piping Liquid (Flare) connections Gas (Flare) Drain Indoor unit Outdoor unit Max interunit piping length Max installation level difference Heat insulation Btu/h kW kcal/h kW m3/min cfm mmH2O dB(A) mm kg °CWB kW kg dB(A) mm kg °CDB mm mm mm mm m m 26 48 51 30 36 42 FDMG26PUV1 FDMG30PUV1 FDMG36PUV1 FDMG42PUV1 FDMG48PUV1 FDMG51PUV1 FDMG26NUV1 FDMG30NUV1 FDMG36NUV1 FDMG42NUV1 FDMG48NUV1 FDMG51NUV1 R30NUV1 R36NUV1 R26NUV1 R48NUY1 R51NUY1 R42NUY1 R30NUY1 R36NUY1 R26NUY1 V1: Phase, 220–240 V, 50 Hz Y1: Phase, 380–415 V, 50 Hz 26,300/26,000 30,400/30,000 36,500/36,000 42,700/42,000 49,100/48,000 52,200/51,000 8.9/8.8 12.5/12.3 7.7/7.6 15.3/15.0 14.4/14.1 10.7/10.6 7,670/7,570 10,800/10,600 12,400/12,100 13,200/12,900 6,630/6,550 9,200/9,100 3.15/3.15 3.46/3.46 4.16/4.16 4.84/4.84 5.55/5.55 5.90/5.90 -42 42 23 34 37 42 1,482 1,482 811 1,200 1,306 1,482 8.5 10.1 9.8 8.0 8.0 9.8 46/37 47/37 42/38 44/36 45/37 46/37 305X1,350X680 305X1,550X680 305X1,550X680 305X1,550X680 305X1,550X680 305X1,900X680 43 51 52 52 52 58 14 to 28 Ivory Hermetically sealed rotary type Hermetically sealed scroll type 2.5 4.50 4.50 2.5 3.00 3.75 2.3(Charged for 10 m) 2.3(Charged for 10 m) 2.0(Charged for 15 m) 2.4(Charged for 15 m) 2.6(Charged for 15 m) 2.7 (Charged for 15 m) 57 57 59 59 55 57 770X900X320 1,170X900X320 1,170X900X320 1,345X900X320 1,345X900X320 770X900X320 87 92 93 70 (V1), 69 (Y1) 70 (V1), 69 (Y1) 81 (V1), 79(Y1) 21 to 46 o/ 9.5 o/ 9.5 o/ 9.5 o/ 9.5 o/ 9.5 o/ 9.5 o/ 15.9 o/ 19.1 o/ 19.1 o/ 19.1 o/ 19.1 o/ 15.9 3/4B (I.D o/ 21.6XO.D o/ 27.2) o/ 26.0 (Hole) o/ 26.0 (Hole) o/ 26.0 (Hole) o/ 26.0 (Hole) o/ 26.0 (Hole) o/ 26.0 (Hole) 30 (equivalent length 50 m) 20 Both liquid and gas piping 56 FDMG56PUV1 FDMG56NUV1 R56NUY1 57,000/56,000 16.7/16.4 14,400/14,100 6.45/6.45 42 1,482 9.8 47/37 305X1,900X680 58 4.50 2.8 (Charged for m) 56 1,345X880X370 114 o/ 9.5 o/ 19.1 o/ 26.0 (Hole) 50 (equivalent length 70 m) 30 Note : Rated cooling capacities are based on the following conditions: 1a Suction temp., 27°CDB, 19.5°CWB; outdoor temp 35°CDB Equiv refrigeration piping, 7.5 m (horizontal) 1b Suction temp., 27°CDB, 19.0°CWB; outdoor temp 35°CDB Equiv refrigeration piping, 7.5 m (horizontal) Anechoic chamber conversion value, measured according to JIS parameters and criteria During operation these values are somewhat higher owing to ambient conditions In case of V1: 220V, Y1: 380V DUCT CONNECTION LOW STATIC PRESSURE TYPE Indoor unit Model Name Outdoor unit Power supply Cooling capacity 1a/1b Power consumption 1a/1b Colour Airflow rate (H/L) Indoor unit Outdoor unit Rated external static pressure Sound level (H/L) (220V) Dimensions (HXWXD) Machine weight Operation range Colour Compressor Type Motor output Refrigerant charge (R-22) Sound level 2, Dimensions (HXWXD) Machine weight Operation range Liquid (Flare) Piping connections Gas (Flare) Drain Indoor unit Outdoor unit Max interunit piping length Max installation level difference Heat insulation Btu/h kW kcal/h kW m3/min cfm mmH2O dB(A) mm kg °CWB kW kg dB(A) mm kg °CDB mm mm mm mm m m 18 FDBG18PUV1 21 FDBG21PUV1 26 FDBG26PUV1 R26NUV1 R18NUV1 R21NUV1 R26NUY1 V1: Phase, 220–240 V, 50 Hz Y1: Phase, 380–415 V, 50 Hz 18,100/18,000 21,200/21,000 26,300/26,000 5.3/5.3 6.2/6.2 7.7/7.6 4,580/4,560 5,340/5,290 6,630/6,550 2.12/2.11 2.73/2.72 3.33/3.33 -13/11 18/15 18/15 458/388 635/529 635/529 2.0 2.0 2.0 41/38 43/40 43/40 260X900X580 260X1,300X580 260X1,300X580 25 32 32 14 to 28 Ivory white Ivory Hermetically sealed rotary type 1.7 2.5 2.2 1.13 2.3 1.55 (Charged for 10 m) (Charged for 10 m) (Charged for 10 m) 49 540X750X270 42 54 685X800X300 61 21 to 46 o/ 6.4 o/ 15.9 3/4B (I.D o/ 21.6XO.D o/ 27.2) o/ 18.0 (Hole) 30 (equivalent length 50 m) o/ 6.4 o/ 15.9 o/ 18.0 (Hole) 15 57 770X900X320 70 (V1), 69 (Y1) o/ 9.5 o/ 15.9 o/ 26.0 (Hole) 20 Both liquid and gas piping Note : Rated cooling capacities are based on the following conditions: 1a Suction temp., 27°CDB, 19.5°CWB; outdoor temp 35°CDB Equiv refrigeration piping, 7.5 m (horizontal) 1b Suction temp., 27°CDB, 19.0°CWB; outdoor temp 35°CDB Equiv refrigeration piping, 7.5 m (horizontal) Anechoic chamber conversion value, measured according to JIS parameters and criteria During operation these values are somewhat higher owing to ambient conditions In case of V1: 220V, Y1: 380V 12 Indoor unit CEILING MOUNTED CASSETTE TYPE Type Item Decoration panel Sealing member for air discharge outlet Panel spacer Fresh air intake kit Chamber Without the T-joint pipe and fan type With the T-joint pipe,without fan Direct installation type High-efficiency filter (Colorimetric method 65%) (Colorimetric method 90%) Replacement (Colorimetric method 65%) high-efficiency filter (Colorimetric method 90%) High-efficiency filter chamber Replacement long-life filter Ultra long-life filter Replacement ultra long-life filter Branch duct chamber Remote controller Wired type2 Wireless type Central remote controller3 Unified ON/OFF controller3 Schedule timer3 Adaptor for wiring4 Wiring adaptor for electrical appendices3 Interface adaptor for SkyAir series Installation box for adaptor PCB FHC18NU FHC21NU FHC26NU FHC30NU FHC36NU FHC42NU FHC48NU BYC125K-W1, BYC125K-W2 KDBH55D160W KDBP55H160WA KDD55DA160 KDD55DA160K KDDJ55X160 KAF556DA160 KAF557DA160 KAFP552B160 KAFP553B160 KAF556DA80 KAF557DA80 KAFP552B80 KAFP553B80 KDDF55D160 KAF551K160 KAFP55D160 KAF55K160H KDJ55K160 KDJ55K80 BRC1C61 BRC7C613W DCS302CA61 DCS301BA61 DST301BA61 KRP1BA57 KRP4AA53 DTA102A52 KRP1B98 Note: Required for installing high-efficiency filter or ultra long-life filter Wiring for wired remote controller to be procured locally This optional accessory requires DTA102A52 Installation box for adaptor PCB (KRP1B98) is necessary CEILING SUSPENDED TYPE Item Replacement long-life filter Resin net L-type piping kit (for upward direction) Wired type1 Remote controller Wireless type Type FH21NU FH26NU FH30NU FH36NU KAF501DA112 KAF501DA80 KHFJ5F80 FH42NU FH48NU KAF501DA160 KHFJ5F160 BRC1NU61 BRC7NU66 Note: Wiring for wired remote controller to be procured locally DUCT CONNECTION Item Remote controller MIDDLE STATIC PRESSURE TYPE Type FDMG26PU FDMG30PU FDMG36PU Wired type1 Wireless type FDMG42PU FDMG48PU FDMG51PU FDMG56PU FDMG48NU FDMG51NU FDMG56NU BRC1C61 BRC4C64 Note: Wiring for wired remote controller to be procured locally Type Item FDMG26NU FDMG30NU FDMG36NU KRC47-1A KRC47-2A Remote controller Digital remote controller DUCT CONNECTION Item Remote controller FDMG42NU LOW STATIC PRESSURE TYPE Type FDBG18PU FDBG21PU Wired type1 Wireless type FDBG26PU BRC1C61 BRC4C64 Note: Wiring for wired remote controller to be procured locally Outdoor unit Item Drain piping kit Central drain plug 13 Type R18NU R21NU - KIS95 - R26NU R30NU R36NU R42NU KKPJ5F180 R48NU R51NU R56NU DIMENSIONS (Unit: mm) CEILING MOUNTED CASSETTE TYPE FHC18NUV1 / 21NUV1 / 26NUV1 / 30NUV1 / 36NUV1 / 42NUV1 / 48NUV1 950 55 55 12-M4 Hole (prepared hole) 150 Branch duct connection A [FHC30NUV1-48NUV1] 55 840 80 100=200 85 40 350 1500mm or more A B C D E FHC18NUV1-26NUV1 230 240 165 FHC30NUV1-48NUV1 288 298 195 165 195 14-M4 Hole (prepared hole) 150 Notes: Location of unit's Name Plate For Main body: Switch Box Cover inside surface of suction grille For decoration panel: Panel frame inside surface of suction grille When installing an optional accessory, refer to the installation drawings For fresh air intake kit Inspection port is necessary For high efficiency filter unit Inspection port is not necessary In case of using wireless remote controller, this position will be a signal receiver Refer to the drawing of wireless remote controller in detail 1500mm or more 1500mm or more When the discharge grill is closeout,the required space is 200mm or more 40 50 155 165 55 For fresh air intake kit connection (direct installation type) 1500mm or more Branch duct connection A Liquid pipe connection Gas pipe connection Drain pipe connection Power supply connection 195 40 350 Required space Remote control code and control wiring connection Air discharge grille 1000 or more Required space 260 270 315 80 B view 1000 or more Required space 165 125 150 B 40 A 30 10 240 Suspension bolt 4-M8 M10 55 60 4-M4 Hole (prepared hole) 75 B [FHC18NUV1-26NUV1] 55 840 80 100=200 85 Branch duct connection C view 95 110 295 840 420 200 750 Adjustable(0~550) A view 40 350 80 10 160 80 100=200 85 C 300 or less D E 950 780 Suspension position 860~890 Ceiling opening Note3 C 860~890 Ceiling opening 680 Suspension position 420 Air suction grille Port for water supply Corner decoration cover 10 Drain hose CEILING SUSPENDED TYPE FH21NUV1 / 26NUV1 / 30NUV1 / 36NUV1 / 42NUV1 / 48NUV1 10 Hanging bolt 4-M8~M10 115 60 15 11 195 300 or more (Required space) 55 B 30 or more (Service space) 30 or more (Service space) The Front Obstacle Floor side Brand name plate (Note.2) Drain pipe connection VP20 (For left piping) 225 275 300 275 80 Notes: Location of unit's Name Plate: Bottom of fan housing inside the suction grille In case of using wireless remote controller, this position will be a signal receiver Refer to the drawing of wireless remote controller in detail The remote control code is the standard attached (0.5 mm2 wicks O.D 5.4) (It is attached to VRV.) 80 105 170 65 Position slit hole for taking out in piping back (View from the front) 127 A (Hanging position) 680 65 60 80 105 135 (Required space) 1550 1590 50 Position : Hole of wall for taking out in piping back (View from the front) 40 FH48NUV1 145 60 90 155 1550 1590 40 135 FH42NUV1 12 85 102 160 185 192 36 1550 1590 For height installaion From the floor side 2500 or more 155 (Required space) 1360 1400 FH36NUV1 210 1120 1160 FH30NUV1 260 FH26NUV1 13 170 105 90 18 17 16 142 58 B 1120 1160 (Hanging position) A FH21NUV1 o/ 45 55 14 Air discharge grille Air suction grille Air filter Gas pipe connection Liquid pipe connection Drain pipe conneciton Earth terminal (inside the electric components box) (M4) Suspension bracket Backward piping and wiring connection opening lid 10 Upward piping and wiring connection opening lid 11 Right side pipe connection 12 Left back drain pipe connection 13 Left side drain pipe connection 14 Right side drain pipe connection 15 Hole of wall for taking out in piping back 16 Upward drain pipe connection 17 Upward gas pipe connection 18 Upward liquid pipe connection 14 DIMENSIONS (Unit: mm) DUCT CONNECTION MIDDLE STATIC PRESSURE TYPE FDMG26PUV1 151 600 (Suspension bolt pinch) 151 16 727 18-M4 Holes (All around) 29 51 150 263 280 305 206 175 123 152 212 274 50 7XP150=1050 305 1134 1114 1350 1153 1137 1121 7XP150=1050 20-M4 Holes 74 16 10 126 1203 (Suspension bolt pinch) Service space 55 427 680 300 or more 116 146 381 1350 1153 (All around) Note: 1Location of unit's Name Plate: Chamber cap Liquid pipe connection Gas pipe connection Drain pipe connection Ground terminal Switch box Control wiring intake (for remote controller) Control wiring intake (for outdoor unit) Suspension bracket FDMG30PUV1 / 36PUV1 / 42PUV1 / 48PUV1 / 51PUV1 / 56PUV1 A 151 381 126 151 16 305 206 175 123 827 G (All Around) Liquid pipe connection Gas pipe connection Drain pipe connection Ground terminal 29 N (All Around) Switch box Control wiring intake (for remote controller) Control wiring intake (for outdoor unit) Suspension bracket Note: 1Location of unit's Name Plate: Chamber cap A B C E F D FDMG30NUV1/36NUV1/42NUV1/48NUV1 1550 1353 1403 1334 1314 7XP150=1050 FDMG51NUV1/56NUV1 1900 1703 1753 1684 1664 9XP150=1350 15 51 G 18-M4 Holes 22-M4 Holes H J K M L 1550 1353 1337 1321 7XP150=1050 1900 1703 1687 1671 9XP150=1350 N O 20-M4 263 24-M4 269 Holes Holes 10 J K L M 150 O 280 152 212 274 50 D E F H 74 16 C (Suspension bolt pinch) 305 Service space 55 427 680 300 or more 146 600 (Suspension bolt pinch) 116 B DUCT CONNECTION MIDDLE STATIC PRESSURE TYPE FDMG26NUV1 151 300 or more 600 (Suspension bolt pinch) Service space 55 427 680 116 146 381 1350 1153 126 1134 1114 1350 1153 1137 1121 7XP150=1050 51 305 305 206 175 123 152 212 274 50 7XP150=1050 151 16 150 263 280 1203 (Suspension bolt pinch) 727 18-M4 Holes 29 (All around) 20-M4 Holes 74 16 10 (All around) Note: 1Location of unit's Name Plate: Chamber cap Liquid pipe connection Gas pipe connection Drain pipe connection Ground terminal Switch box Control wiring intake (for remote controller) Control wiring intake (for outdoor unit) Suspension bracket FDMG30NUV1 / 36NUV1 / 42NUV1 / 48NUV1 / 51NUV1 / 56NUV1 A 151 B 381 146 116 Service space 55 427 680 600 (Suspension bolt pinch) 300 or more C 126 (Suspension bolt pinch) H D 150 263 280 74 10 305 16 29 274 152 827 G L M 212 50 K 51 F 123 175 206 J 16 E 305 151 (All Around) N (All Around) Liquid pipe connection Gas pipe connection Drain pipe connection Ground terminal Switch box Control wiring intake (for remote controller) Control wiring intake (for outdoor unit) Suspension bracket Note: 1Location of unit's Name Plate: Chamber cap A B C E F D FDMG30NUV1/36NUV1/42NUV1/48NUV1 1550 1353 1403 1334 1314 7XP150=1050 FDMG51NUV1/56NUV1 1900 1703 1753 1684 1664 9XP150=1350 G 18-M4 Holes 22-M4 Holes H J K M L 1550 1353 1337 1321 7XP150=1050 1900 1703 1687 1671 9XP150=1350 N 20-M4 Holes 24-M4 Holes 16 DIMENSIONS (Unit: mm) DUCT CONNECTION LOW STATIC PRESSURE TYPE FDBG18PUV1 / 21PUV1 / 26PUV1 B A 151 Unit(mm) 126 10 or more 5 260 110 170 228 Liquid pipe connection Gas pipe connection Drain pipe connection Ground terminal 29 O (All around) 16 10 151 H I J K L M Switch box Control wiring intake (for remote controller) Control wiring intake (for outdoor unit) Suspension bracket Note: 1Location of unit's Name Plate: Chamber cap FDBG18PUV1 FDBG21PUV1/26PUV1 17 150 219 236 G N (All around) Service space A B C F D E 900 704 755 684 664 3XP150=450 1300 1104 1155 1084 1064 6XP150=900 G 500 700 H 127 102 I 52 16 10 C (Suspension bolt pinch) D E F 260 164 134 107 50 300 or more 55 317 580 500 (Suspension bolt pinch) 137 167 271 J K L M 3XP150=450 674 688 704 900 6XP150=900 1074 1088 1104 1300 N O 10-M4 12-M4 Holes Holes 16-M4 18-M4 Holes Holes OUTDOOR UNIT R18NUV1 700 Holes for anchor bolts (M8 or M10) 520 190 170 60 27 95 237 213 48 290 306 3-Drain outlets 34 72 100 530 15 540 750 270 Terminal cover Earth terminal (M4) Power intake Gas stop valve Name plate 105 34 Liquid stop valve 58 27 Service port Minimum space for air passage H Less than 1000 More than 1000 Space A More than 300 More than 600 A H 100 50 150 A 50 50 R21NUV1 Holes for anchor bolts (M8 or M10) 330 350 98 31 269 540 130 2-Drain outlet 800 Outdoor air thermostat 300 15 Earth terminal (M4) Power intake Name plate 685 645 Liquid stop valve Liquid pipe 95 70 Service port Gas stop valve 75 100 Gas pipe A 50 50 A 100 50 150 H Minimum space for air passage H H 1000 H 1000 A 300 600 18 DIMENSIONS (Unit: mm) OUTDOOR UNIT Hole for anchor bolt 4-M12 48 55 320 350 (345~355) 30 R26NUV1/Y1 R30NUV1/Y1 140 30 30 40 96 140 620 900 6 89 142 19 71 16 223 53 95 19 80 145 52 13 67 70 102 117 58 16 54 95 84 55 54 95 143 89 28 60 329 352 55 770 4 45 376 Gas pipe connection Liquid pipe connection 191 Grounding terminal M5(in switch box) Refrigerant piping intake Power supply wiring intake Control wiring intake Drain connection Note: In some circumstances, with certain machine types, it may not be possible to attach the supplied piping Hole for anchor bolt 4-M12 140 30 41 320 30 96 140 620 900 61 48 350 (345~355) 30 R36NUV1/Y1 7 1170 6 58 70 102 117 19 376 191 148 223 80 52 145 13 67 16 45 95 54 54 19 19 16 71 84 55 410 435 95 157.5 60 89 24 89 142 54 5 Gas pipe connection Liquid pipe connection Service port(in the unit) Grounding terminal Refrigerant piping intake Power supply wiring intake Control wiring intake Drain pipe connection OUTDOOR UNIT R42NUY1, R48NUY1, R51NUY1 A B C D R42NUY1 1170 54 113 579 R48NUY1/51NUY1 1345 55 — — 48 61 320 350 (345~355) 30 Hole for anchor bolt 4-M12 140 30 41 96 140 620 900 30 7 6 19 142 95 53 84 95 54 89 19 D 55 410 435 95 54 60 89 24 C B 223 A 80 145 13 Service port (in the unit) Grounding terminal M5 (in switch box) Refrigerant piping intake 58 70 102 117 376 Power supply wiring intake Control wiring intake 191 Drain pipe connection 30 Hole for anchor bolt 4-M12 146 584 30 35 370 84 38 396 150 880 30 1345 144 84 14 67 115 14 90 Gas pipe connection Liquid pipe connection 391 60 49 61 11 90 14 137 102 11 95 568 49 84 name plate 40 24 95 60 538 275 R56NUY1 Gas pipe connection Liquid pipe connection 45 67 16 16 71 52 Service port(in the unit) Grounding terminal M5(in switch box) Refrigerant piping intake Power supply wiring intake Control wiring intake Drain outlet 20 DIMENSIONS (Unit: mm) REMOTE CONTROLLER Wireless type Remote controller dimensions BRC7C613W BRC4C64 CEILING MOUNTED CASSETTE TYPE Remote controller holder installation procedure 157 Transmitting part Receiver installation procedure Receiver Drain piping side Liquid crystal remote controller (Wireless) Remote controller holder 62 Receiver detail Refrigerant piping side Decoration panel 17.5 BRC7NU66 CEILING SUSPENDED TYPE Transmitting part Remote controller holder installation procedure Receiver installation procedure The Front Receiver detail Receiver 115.5 Remote controller (Wireless) Remote controller holder 54 18.1 Receiver detail 2-5x9 Slot 18 0.535 70 49 Switch box (Ceiling opening) (field Supplied parts) Wired type Remote controller dimensions KRC47-2A 25 18 19 58 38 17 18 23 28 46 Conduit 17 CONTROL BOX Note) Remote controller cord and staple are not attached they are field supplied parts (ß12~ß16) Specifications of cord Vinyl cord with sheath or cable Type (Insulated thickness: mm or more) Size 0.75~1.25 mm2 Total length 500 m * Countries requiring EMC: Shield wire (insulated thickness: mm or more) 44.5 20 25 119 A 24 B B B 17 R2 10 22 25 13 A 25 20 41 38 41.5 A A Note) The dimension of hole a BRC1NU61 111 Through hole 17 ( Distance between remote controller and control box ) Hole type a (mm) A B 10 KRC47-1A 136 124 81 0~5 17 C Exposed body, embedded code 77 Staple B Exposed body, embedded cord 14 117 A EXposed body, exposed cord 92 61 Remote controller installation procedure Cord outlet hole 36 120 21 110 84 120 42 BRC1C61 85 32 More than 90 (Srevice space) 120 72 83.5 106 (Ceiling opening) Service space for ceiling installation Notenot: install more than Do receivers in the vicinity of one another With or more units, there is always the possibility of malfunction [Space required for outdoor unit installation] (Unit: mm) Dimensions inside brackets [ ] indicate case where air direction adjustment guide is adjusted downward The values represent the case for the R26 type through R56 type The dimensions in ( ) are for the R36 and R56 type (The unit values is mm ) In case of R56 model, the values in < > are those when the air discharge direction of the grille is downward For R26NU-56NU When there is an obstruction on the inlet side When there is an obstruction on the outlet side When the overhead space is open When the overhead space is open For single unit installation For single unit installation When there is an obstruction only on the inlet side For series installation (more than two units) 0) 0(1 or ore 500 or m re mo When there are obstructions on both sides ore rm 0o or m ore 100 or m 10 ore When there is an obstruction in the overhead space re mo or ss 500 or le 1000 or more 100 100 For single unit installation For series installation (more than two units) When there are obstructions on both sides 0o ore For series installation (more than two units) 500 or m ss or le 500 1000 or more 100 An obstruction in the overhead space rm ore 200 0) or m 0(3 ore or An obstruction in the overhead space re mo 20 ore rm 0o 100 When there is an obstruction in the overhead space When there are obstructions on both the inlet and outlet sides For single unit installation 500 ss or le 1000 or more When there is an obstruction on the inlet side An obstruction in the overhead space Pattern When the obstruction on the outlet side is higher than the unit itself (There is no limit to the height of the obstruction on the outlet side.) When the overhead space is open ore 100 or m For single unit installation L H 1000 or more When there are obstructions on the inlet side and ss or le both lateral sides 500 For other patterns, please refer to engineering databook An obstruction in the overhead space or mo L re 150 or ore 150 mo re or m For series installation (more than two units) ss 1000 or more 500 or le An obstruction in the overhead space 0o ore or m 500 1000> < ) 100 50( more or For series installation (more than two units) L When there are obstructions on the inlet side and both lateral sides 100 H L rm ore 200 or re (3 00 ore rm 0o > 100 1500 < 0) (30 200 more or ore rm )o 00 mo H H 150 22 Warning Daikin products are manufactured for export to numerous countries throughout the world Prior to purchase, please confirm with your local authorised importer, distributor and/or retailer whether this product conforms to the applicable standards, and is suitable for use, in the region where the product will be used This statement does not purport to exclude, restrict or modify the application of any local legislation Ask a qualified installer or contractor to install this product Do not try to install the product yourself Improper installation can result in water or refrigerant leakage, electrical shock, fire or explosion Use only those parts and accessories supplied or specified by Daikin Ask a qualified installer or contractor to install those parts and accessories Use of unauthorised parts and accessories or improper installation of parts and accessories can result in water or refrigerant leakage, electrical shock, fire or explosion Read the User's Manual carefully before using this product The User's Manual provides important safety instructions and warnings Be sure to follow these instructions and warnings If you have any enquiries, please contact your local importer, distributor and/or retailer Cautions on product corrosion Air conditioners should not be installed in areas where corrosive gases, such as acid gas or alkaline gas, are produced If the outdoor unit is to be installed close to the sea shore, direct exposure to the sea breeze should be avoided If you need to install the outdoor unit close to the sea shore, contact your local distributor Organization: DAIKIN INDUSTRIES, LTD AIR CONDITIONING MANUFACTURING DIVISION JMI-0107 Scope of Registration: THE DESIGN/DEVELOPMENT AND MANUFACTURE OF COMMERCIAL AIR CONDITIONING, HEATING, COOLING, REFRIGERATING EQUIPMENT, COMMERCIAL HEATING EQUIPMENT, RESIDENTIAL AIR CONDITIONING EQUIPMENT, HEAT RECLAIM VENTILATION, AIR CLEANING EQUIPMENT, MARINE TYPE CONTAINER REFRIGERATION UNITS, COMPRESSORS AND VALVES Organization: DAIKIN INDUSTRIES (THAILAND) LTD JQA-1452 Scope of Registration: THE DESIGN/DEVELOPMENT AND MANUFACTURE OF AIR CONDITIONERS AND THE COMPONENTS INCLUDING COMPRESSORS USED FOR THEM Dealer All of the Daikin Group’s business facilities and subsidiaries in Japan are certified under the ISO 14001 international standard for environment management Head Office: Umeda Center Bldg., 2-4-12, Nakazaki-Nishi, Kita-ku, Osaka, 530-8323 Japan Tokyo Office: JR Shinagawa East Bldg., 2-18-1, Konan, Minato-ku, Tokyo, 108-0075 Japan http://www.daikin.com/global_ac/ c All rights reserved Specifications, designs and other content appearing in this brochure are current as of April 2011 but subject to change without notice 04/11/002 YW• SS ... filter Branch duct chamber Remote controller Wired type2 Wireless type Central remote controller3 Unified ON/OFF controller3 Schedule timer3 Adaptor for wiring4 Wiring adaptor for electrical... lateral sides 100 H L rm ore 200 or re (3 00 ore rm 0o > 100 1500 < 0) (30 200 more or ore rm )o 00 mo H H 150 22 Warning Daikin products are manufactured for export to numerous countries throughout... procedure 157 Transmitting part Receiver installation procedure Receiver Drain piping side Liquid crystal remote controller (Wireless) Remote controller holder

Ngày đăng: 29/11/2017, 04:26

Tài liệu cùng người dùng

  • Đang cập nhật ...

Tài liệu liên quan