Daikin skyair ga R 22 hai chieu

39 191 1
Daikin skyair ga R  22 hai chieu

Đang tải... (xem toàn văn)

Tài liệu hạn chế xem trước, để xem đầy đủ mời bạn chọn Tải xuống

Thông tin tài liệu

Simultaneous operation system TWIN & TRIPLE & DOUBLE TWIN MULTI CEILING SUSPENDED TYPE Indoor unit Model Name Outdoor unit Power supply Cooling capacity 1a/1b kW Btu/h kcal/h Power consumption 1a/1b Indoor unit Outdoor unit kW Colour Airflow rate (H) m3/min cfm dB(A) Sound level (H/L) mm Dimensions (HXWXD) kg Machine weight ¡ Certified operation range CWB Colour Compressor Type kW Motor output Refrigerant charge (R-22) kg dB(A) Sound level mm Dimensions (HXWXD) kg Machine weight Certified operation range ¡CDB mm Piping Liquid (Flare) connections Gas mm mm Drain Indoor unit Outdoor unit mm m Max interunit piping length m Max installation level difference Heat insulation DUCT CONNECTION MIDDLE STATIC PRESSURE TYPE 200 250 71 100 125 140 FHY100BVE × FHY125BVE × FHY35BVE × FHY50BVE × FHY60BVE × FHY71BVE × R71LUV1 R100LUV1 R200KUY1 R250KUY1 R125LUY1 R140LUY1 R71LUY1 R100LUY1 VE: Phase, 220—240/220 V, 50/60 Hz V1: Phase, 220—240 V, 50 Hz Y1: Phase, 380—415 V, 50 Hz 22.5/22.2 27.1/26.6 7.8/7.7 10.6/10.5 13.0/12.8 14.5/14.2 76,800/75,800 92,500/90,800 26,600/26,200 36,100/35,700 44,500/43,600 49,400/48,400 19,400/19,100 23,300/22,900 6,700/6,600 9,100/9,000 11,200/11,000 12,500/12,200 3.20/3.20 (V1) 3.95/3.95 (V1) 7.7/7.6 9.7/9.7 4.98/4.98 5.17/5.17 3.18/3.18 (Y1) 3.90/3.90 (Y1) White 17 24 30 13 16 13 847 1,059 458 458 564 600 42/37 44/39 37/32 38/33 38/33 39/35 195X1,160X680 195X960X680 195X1,160X680 195X1,590X680 195X1,400X680 195X960X680 23 24 26 27 32 35 14 to 25 Ivory white Hermetically sealed scroll type 2.24 3.00 3.75 4.50 5.5 9.0 2.8 3.7 3.7 4.1 5.3 5.7 (Charged for 30 m) (Charged for 30 m) (Charged for 30 m) (Charged for 30 m) (Charged for m) (Charged for m) 48 49 49 54 60 61 1,170X900X320 1,170X900X320 1,345X900X320 1,220X1,280X690 1,440X1,280X690 770X900X320 72 (V1), 71 (Y1) 87 (V1), 84 (Y1) 98 109 178 202 -5 to 52 21 to 46, -15 to 46 (Option installed) o/ 9.5 o/ 9.5 o/ 9.5 o/ 12.7 o/ 15.9 o/ 9.5 o/ 15.9 (Flare) o/ 19.1 (Flare) o/ 19.1 (Flare) o/ 19.1 (Flare) o/ 25.4 (Flange) o/ 28.6 (Flange) I.D o/ 20XO.Do/ 26 I.Do/ 20XO.Do/ 26 I.Do/ 20XO.Do/ 26 I.Do/ 20XO.Do/ 26 I.D o/ 20XO.D o/ 26 I.Do/ 20XO.Do/ 26 o/ 26.0 (Hole) o/ 26.0 (Hole) o/ 26.0 (Hole) o/ 26.0 (Hole) 50 (equivalent length 70 m) 30 Both liquid and gas piping 200 200 140 FHY71BVE × FHY50BVE × FHY50BVE × R200KUY1 R200KUY1 R140LUY1 VE: Phase, 220—240/220 V, 50/60 Hz Y1: Phase, 380—415 V,50 Hz 14.5/14.2 22.5/22.2 kW 22.5/22.2 49,600/48,400 76,800/75,800 Btu/h 76,800/75,800 12,500/12,200 19,400/19,100 kcal/h 19,400/19,100 kW 5.17/5.17 7.7/7.6 7.7/7.6 Power consumption 1a/1b White Colour Indoor m3/min 13 17 13 Airflow rate (H) unit 458 cfm 600 458 dB(A) 39/35 38/33 38/33 Sound level (H/L) 195X1,160X680 195X960X680 195X960X680 mm Dimensions (HXWXD) 24 27 24 kg Machine weight 14 to 25 Certified operation range ¡CWB Ivory white Colour Outdoor Hermetically sealed scroll type Compressor Type unit 5.5 5.5 4.50 kW Motor output 4.1 (Charged for 30 m) 5.3 (Charged for m) 5.3 (Charged for m) kg Refrigerant charge (R-22) 60 60 dB(A) 54 Sound level mm 1,220X1,280X690 1,345X900X320 1,220X1,280X690 Dimensions (HXWXD) kg 109 178 178 Machine weight -5 to 52 Certified operation range ¡CDB 21 to 46, -15 to 46 (Option installed) mm Piping Liquid (Flare) o/ 12.7 o/ 12.7 o/ 9.5 connections Gas mm o/ 25.4 (Flange) o/ 25.4 (Flange) o/ 19.1 (Flare) mm Drain Indoor unit I.D o/ 20XO.D o/ 26 I.Do/ 20XO.Do/ 26 I.Do/ 20XO.Do/ 26 Outdoor unit mm o/ 26.0 (Hole) m 50 (equivalent length 70 m) Max interunit piping length 30 m Max installation level difference Both liquid and gas piping Heat insulation Indoor unit Model Name Outdoor unit Power supply Cooling capacity 1a/1b 250 FHY60BVE × R250KUY1 Model Name Power supply Cooling capacity 1a/1b Indoor unit Outdoor unit Power consumption 1a/1b Colour Fan Airflow rate (H) Indoor unit External static pressure Sound level (H) Dimensions (HXWXD) Machine weight Certified operation range Colour Outdoor Compressor Type unit Motor output Refrigerant charge (R-22) Sound level Dimensions (HXWXD) Machine weight Certified operation range Piping Liquid (Flare) connections Gas (Flange) Drain Indoor unit Outdoor unit Max interunit piping length Max installation level difference Heat insulation kW Btu/h kcal/h kW m3/min cfm Pa(mmH2O) dB(A) mm kg ¡CWB kW kg dB(A) mm kg ¡CDB mm mm mm mm m m 200 250 200 FDYM04FAV1 × FDYM05FAV1 × FDYM03FAV1 × R200KUY1 R250KUY1 R200KUY1 V1: Phase, 220—240 V, 50 Hz Y1: Phase, 380—415 V, 50 Hz 22.5/22.2 27.1/26.6 22.5/22.2 76,800/75,800 92,500/90,800 76,800/75,800 19,400/19,100 23,300/22,900 19,400/19,100 7.7/7.6 9.9/9.9 8.0/7.9 -26 35 20 917 1,235 706 98(10) 98(10) 98(10) 39 44 39 295X1,500X680 295X1,500X680 295X1,100X680 56 57 42 14 to 25 Ivory white Hermetically sealed scroll type 9.0 5.5 5.5 5.3 (Charged for m) 5.7 (Charged for m) 5.3 (Charged for m) 60 61 60 1,440X1,280X690 1,220X1,280X690 1,220X1,280X690 178 178 202 -5 to 52 o/ 15.9 o/ 12.7 o/ 12.7 o/ 25.4 o/ 28.6 o/ 25.4 o/ 25I.D.,o/ 32O.D o/ 25I.D.,o/ 32O.D o/ 25I.D.,o/ 32O.D 50 (equivalent length 70 m) 30 Both liquid and gas piping Note : Models R200KU and R250KU are recommended for commercial facilities Rated cooling capacities are based on the following conditions: 1a Suction temp., 27¡CDB, 19.5¡CWB; outdoor temp 35¡CDB Equiv refrigeration piping, m (horizontal) 1b Suction temp., 27¡CDB, 19.0¡CWB; outdoor temp 35¡CDB Equiv refrigeration piping, m (horizontal) Anechoic chamber conversion value, measured according to JIS parameters and criteria During operation these values are somewhat higher owing to ambient conditions Values shown are for a single unit only 27.1/26.6 92,500/90,800 23,300/22,900 9.7/9.7 16 564 38/33 195X1,160X680 26 9.0 5.7 (Charged for m) 61 1,440X1,280X690 202 o/ 15.9 o/ 28.6 (Flange) I.Do/ 20XO.Do/ 26 - Note : Models R200KU and R250KU are recommended for commercial facilities Rated cooling capacities are based on the following conditions: 1a Indoor temp., 27¡CDB, 19.5¡CWB; outdoor temp 35¡CDB Equiv refrigeration piping, m (horizontal) 1b Indoor temp., 27¡CDB, 19.0¡CWB; outdoor temp 35¡CDB Equiv refrigeration piping, m (horizontal) (R71LU-R140LU is 7.5 m.) Anechoic chamber conversion value, measured according to JIS parameters and criteria During operation these values are somewhat higher owing to ambient conditions Values shown are for a single unit only This value is for when year-round cooling kit (option) is installed 47 48 CEILING MOUNTED CASSETTE TYPE Outdoor unit Power supply Cooling capacity 1a/1b kW Btu/h kcal/h kW Btu/h kcal/h kW kW Heating capacity Cooling 1a/1b Heating Unit Colour Decoration panel m3/min Airflow rate (H) cfm dB(A) Sound level (H/L) mm Dimensions Unit (H×W×D) mm Decoration panel kg Machine weight Unit kg Decoration panel ¡CWB Cooling Certified operation range Heating ¡CDB Colour Compressor Type Motor output kW Power consumption Indoor unit Outdoor unit 35 FHYC35KVE Indoor unit Model Name Refrigerant charge (R-22) Sound level (Cooling/Heating) Dimensions (H×W×D) Machine weight Cooling Certified operation range Heating Piping Liquid (Flare) connections Gas (Flare) Drain Indoor unit Outdoor unit Max interunit piping length Max installation level difference Heat insulation kg dB(A) mm kg ¡CDB ¡CWB mm mm mm mm m m 50 FHYC50KVE 60 FHYC60KVE 71 140 100 125 FHYC71KVE FHYC100KVE FHYC125KVE FHYC140KVE RY100LUV1 RY71LUV1 RY35FV1A RY50GAV1A RY60GAV1A RY125LUY1 RY140LUY1 RY71LUY1 RY100LUY1 VE: Phase 220—240/220 V, 50/60 Hz V1: Phase 220—240 V, 50 Hz Y1: Phase, 380—415 V, 50 Hz 14.5/14.2 5.27/5.2 6.24/6.15 3.79/3.75 7.8/7.7 10.5/10.4 13.0/12.8 12,900/12,800 18,000/17,800 21,300/21,000 26,600/26,200 35,700/35,300 44,500/43,600 49,400/48,400 3,260/3,230 9,000/8,900 4,530/4,470 5,370/5,290 6,700/6,600 11,200/11,000 12,500/12,200 16.3 4.22 7.9 11.2 14.2 5.8 7.0 56,000 14,400 27,000 38,100 48,400 19,800 23,900 14,000 3,630 6,800 9,600 12,200 4,990 6,020 4.95/4.95 3.01 /3.01 (V1), 2.99/2.99 (Y1) 3.93 /3.93 (V1), 3.88/3.88 (Y1) 1.92/1.91 2.35/2.33 1.51/1.50 4.89/4.89 4.84 1.37 2.84 (V1), 2.82 (Y1) 3.64 (V1), 3.60 (Y1) 4.68 1.68 2.26 -White 14 15 19 19 33 35 28 494 529 670 670 1,164 1,235 988 33/29 33/29 35/30 35/30 39/34 42/36 44/37 230×840×840 230×840×840 230×840×840 230×840×840 288×840×840 288×840×840 288×840×840 40×950×950 40×950×950 40×950×950 40×950×950 40×950×950 40×950×950 40×950×950 24 24 24 24 28 28 28 5 5 5 14 to 23 12 to 25 15 to 28 15 to 27 Ivory white Hermetically sealed rotary type Hermetically sealed scroll type 3.00 3.75 1.3 1.7 2.2 2.24 4.50 3.7 3.7 1.12 1.55 1.75 2.8 4.1 (Charged for 10 m) (Charged for 10 m) (Charged for m) (Charged for 30 m) (Charged for 30 m) (Charged for 30 m) (Charged for 30 m) 47/48 540×750×270 41 o/ 6.4 o/ 12.7 I.Do/ 25×O.Do/ 32 o/ 18.0 (Hole) 20 49/51 685×800×300 51 19.4 to 46 -10 to 15.5 o/ 6.4 o/ 15.9 I.Do/ 25×O.Do/ 32 o/ 18.0 (Hole) 15 54/54 685×880×350 75 48/49 49/52 49/52 54/56 770×900×320 1,170×900×320 1,170×900×320 1,345×900×320 101 73 (V1), 72 (Y1) 89 (V1), 86 (Y1) 112 -5 to 46 -10 to 15 o/ 6.4 o/ 9.5 o/ 9.5 o/ 9.5 o/ 9.5 o/ 15.9 o/ 15.9 o/ 19.1 o/ 19.1 o/ 19.1 I.Do/ 25×O.Do/ 32 I.Do/ 25×O.Do/ 32 I.Do/ 25×O.Do/ 32 I.Do/ 25×O.Do/ 32 I.Do/ 25×O.Do/ 32 o/ 18.0 (Hole) o/ 26.0 (Hole) o/ 26.0 (Hole) o/ 26.0 (Hole) o/ 26.0 (Hole) 30 50 (equivalent length 70 m) 30 Both liquid and gas piping CEILING SUSPENDED TYPE Indoor unit Model Name Outdoor unit Power supply Cooling capacity 1a/1b Heating capacity Power consumption Indoor unit Outdoor unit Cooling 1a/1b Heating Colour Airflow rate (H) Sound level (H/L) Dimensions (HXWXD) Machine weight Cooling Certified operation range Heating Colour Compressor Type Motor output Refrigerant charge (R-22) Sound level (Cooling/Heating) Dimensions (HXWXD) Machine weight Cooling Certified operation range Heating Piping Liquid (Flare) connections Gas (Flare) Drain Indoor unit Outdoor unit Max interunit piping length Max installation level difference Heat insulation 71 100 125 FHY71BVE FHY100BVE FHY125BVE RY71LUV1 RY100LUV1 RY50GAV1A RY60GAV1A RY35FV1A RY125LUY1 RY100LUY1 RY71LUY1 VE: Phase 220—240/220 V, 50/60 Hz V1: Phase 220—240 V, 50 Hz Y1: Phase, 380—415 V, 50 Hz 5.0/4.85 6.3/6.15 7.8/7.7 10.5/10.4 13.0/12.8 3.5/3.5 kW 16,900/16,600 21,400/21,000 12,100/11,900 26,600/26,200 35,700/35,300 44,500/43,600 Btu/h 4,260/4,200 5,390/5,300 3,040/3,000 6,700/6,600 9,000/8,900 11,200/11,000 kcal/h 7.1 5.5 11.2 14.2 4.1 7.9 kW 24,200 18,800 14,000 27,000 38,100 48,400 Btu/h 4,750 6,100 3,520 6,800 9,600 12,200 kcal/h 2.17/2.16 3.14/3.12 4.85/4.85 3.04/3.04 (V1), 3.02/3.02 (Y1) 3.82/3.82 (V1), 3.77/3.77 (Y1) kW 1.58/1.57 1.96 2.94 1.37 2.98 (V1), 2.95 (Y1) 3.69 (V1), 3.64 (Y1) 4.77 kW White 30 m3/min 13 16 17 24 13 1,059 cfm 458 564 600 847 458 dB(A) 44/39 38/33 38/33 39/35 42/37 37/32 mm 195X1,590X680 195X960X680 195X1,160X680 195X1,160X680 195X1,400X680 195X960X680 kg 23 24 26 27 32 35 ¡CWB 14 to 23 12 to 25 ¡CDB 15 to 28 15 to 27 Ivory white Hermetically sealed rotary type Hermetically sealed scroll type kW 1.3 1.7 2.2 2.24 3.00 3.75 1.12 1.55 1.75 2.8 3.7 3.7 kg (Charged for 10 m) (Charged for 10 m) (Charged for m) (Charged for 30 m) (Charged for 30 m) (Charged for 30 m) 35 FHY35BVE dB(A) mm kg ¡CDB ¡CWB mm mm mm mm m m 47/48 540X750X270 41 o/ 6.4 o/ 12.7 I.D o/ 20XO.D o/ 26 o/ 18.0 (Hole) 20 50 FHY50BVE 49/51 685X800X300 51 19.4 to 46 -10 to 15.5 o/ 6.4 o/ 15.9 I.Do/ 20XO.Do/ 26 o/ 18.0 (Hole) 15 60 FHY60BVE 54/54 685X880X350 75 49/52 49/52 1,170X900X320 1,170X900X320 101 89 (V1), 86 (Y1) -5 to 46 -10 to 15 o/ 6.4 o/ 9.5 o/ 9.5 o/ 9.5 o/ 15.9 o/ 15.9 o/ 19.1 o/ 19.1 I.Do/ 20XO.Do/ 26 I.Do/ 20XO.Do/ 26 I.Do/ 20XO.Do/ 26 I.Do/ 20XO.Do/ 26 o/ 18.0 (Hole) o/ 26.0 (Hole) o/ 26.0 (Hole) o/ 26.0 (Hole) 30 50 (equivalent length 70 m) 30 Both liquid and gas piping Note : Rated cooling capacities are based on the following conditions: 1a Indoor temp., 27¡CDB, 19.5¡CWB; outdoor temp 35¡CDB Equiv refrigeration piping, m (horizontal) 1b Indoor temp., 27¡CDB, 19.0¡CWB; outdoor temp 35¡CDB Equiv refrigeration piping, m (horizontal) (RY71LU-RY140LU is 7.5 m.) Rated heating capacities are based on the following conditions: Indoor temp., 20¡CDB; outdoor temp., 7¡CDB, 6¡CWB Equiv refrigeration piping, m (horizontal) (RY71LU-RY140LU is 7.5 m.) Anechoic chamber conversion value, measured according to JIS parameters and criteria During operation these values are somewhat higher owing to ambient conditions 49 48/49 770X900X320 73 (V1), 72 (Y1) CEILING SUSPENDED CASSETTE TYPE Model Name Outdoor unit Power supply Cooling capacity 1a/1b Heating capacity Power consumption Indoor unit 71 FUY71FJV1 RY71LUV1 RY71LUY1 Indoor unit Cooling 1a/1b Heating Colour Airflow rate (H) Sound level (H/L) Dimensions (HXWXD) Machine weight Cooling Certified operation range Heating Colour Outdoor Compressor Type unit Motor output Refrigerant charge (R-22) Sound level (Cooling/Heating) Dimensions (HXWXD) Machine weight Cooling Certified operation range Heating Piping Liquid (Flare) connections Gas (Flare) Drain Indoor unit Outdoor unit Max interunit piping length Max installation level difference Heat insulation kW Btu/h kcal/h kW Btu/h kcal/h kW kW m3/min cfm dB(A) mm kg ¡CWB ¡CDB kW kg dB(A) mm kg ¡CDB ¡CWB mm mm mm mm m m 100 125 FUY100FJV1 FUY125FJV1 RY100LUV1 RY125LUY1 RY100LUY1 V1: Phase 220—240 V, 50 Hz Y1: Phase, 380—415 V, 50 Hz 7.8/7.7 13.0/12.8 10.5/10.4 26,600/26,200 44,500/43,600 35,700/35,300 6,700/6,600 9,000/8,900 11,200/11,000 7.9 11.2 14.2 27,000 38,100 48,400 6,800 9,600 12,200 4.90/4.90 3.02/3.02 (V1), 3.00/3.00 (Y1) 3.99/3.99 (V1), 3.94/3.94 (Y1) 4.61 2.87 (V1), 2.84 (Y1) 3.66 (V1), 3.62 (Y1) White 19 29 32 670 1,023 1,129 43/38 44/39 40/35 230X895X895 230X895X895 165X895X895 25 31 31 12 to 25 15 to 27 Ivory white Hermetically sealed scroll type 2.24 3.00 3.75 2.8 (Charged for 30 m) 3.7 (Charged for 30 m) 3.7 (Charged for 30 m) 48/49 49/52 49/52 770X900X320 1,170X900X320 1,170X900X320 89 (V1), 86 (Y1) 73 (V1), 72 (Y1) 101 -5 to 46 -10 to 15 o/ 9.5 o/ 9.5 o/ 9.5 o/ 15.9 o/ 19.1 o/ 19.1 I.Do/ 20XO.Do/ 26 o/ 26.0 (Hole) o/ 26.0 (Hole) o/ 26.0 (Hole) 50 (equivalent length 70 m) 30 Both liquid and gas piping CEILING MOUNTED CASSETTE CORNER TYPE Model Name Power supply Cooling capacity 1a/1b Heating capacity Indoor unit Outdoor unit kW Btu/h kcal/h kW Btu/h kcal/h kW kW Cooling 1a/1b Heating Unit Colour Indoor Decoration panel unit m3/min Airflow rate (H) cfm dB(A) Sound level (H/L) mm Dimensions Unit (HXWXD) mm Decoration panel kg Machine weight Unit kg Decoration panel ¡CWB Cooling Certified ¡CDB operation range Heating Colour Outdoor Compressor Type unit Motor output kW kg Refrigerant charge (R-22) dB(A) Sound level (Cooling/Heating) mm Dimensions (HXWXD) kg Machine weight ¡CDB Cooling Certified ¡CWB operation range Heating mm Piping Liquid (Flare) connections mm Gas (Flare) mm Drain Indoor unit mm Outdoor unit m Max interunit piping length m Max installation level difference Heat insulation Power consumption 35 FHYK35FJV1 45 FHYK45FJV1 60 FHYK60FJV1 RY35FV1A RY50GAV1A RY60GAV1A 71 FHYK71FJV1 RY71LUV1 RY71LUY1 V1: Phase, 220—240 V, 50 Hz Y1: Phase, 380—415 V, 50 Hz 7.8/7.7 5.0/4.85 6.3/6.15 3.5/3.5 26,600/26,200 16,900/16,600 21,400/21,000 12,100/11,900 5,390/5,300 6,700/6,600 4,260/4,200 3,040/3,000 7.1 4.1 5.5 7.9 14,000 18,800 24,000 27,000 3,520 4,740 6,080 6,800 1.47/1.46 1.95/1.94 2.87/2.85 3.01/3.01 (V1), 2.99/2.99 (Y1) 1,25 1.72 2.65 2.91 (V1), 2.88 (Y1) -White 17 12 17 12 600 423 600 423 41/36 39/34 41/36 39/33 215X1,310X710 215X1,110X710 215X1,110X710 215X1,310X710 70X1,240X800 70X1,240X800 70X1,440X800 70X1,440X800 30 31 33 33 8.5 8.5 9.5 9.5 14 to 23 12 to 25 15 to 27 15 to 28 Ivory white Hermetically sealed scroll type Hermetically sealed rotary type 2.24 1.3 1.7 2.2 1.55 (Charged for 10 m) 1.75 (Charged for m) 2.8 (Charged for 30 m) 1.12 (Charged for 10 m) 47/48 49/51 54/54 48/49 540×750×270 685×800×300 685×880×350 770×900×320 41 51 75 73 (V1), 72 (Y1) -5 to 46 19.4 to 46 -10 to 15 -10 to 15.5 o/ 6.4 o/ 6.4 o/ 6.4 o/ 9.5 o/ 12.7 o/ 15.9 o/ 15.9 o/ 15.9 I.Do/ 25×O.Do/ 32 I.Do/ 25×O.Do/ 32 I.Do/ 25×O.D o/ 32 I.D o/ 25×O.D o/ 32 o/ 18.0 (Hole) o/ 18.0 (Hole) o/ 18.0 (Hole) o/ 26.0 (Hole) 20 30 50 (equivalent length 70 m) 15 30 Both liquid and gas piping Note : Rated cooling capacities are based on the following conditions: 1a Indoor temp., 27¡CDB, 19.5¡CWB; outdoor temp 35¡CDB Equiv refrigeration piping, m (horizontal) 1b Indoor temp., 27¡CDB, 19.0¡CWB; outdoor temp 35¡CDB Equiv refrigeration piping, m (horizontal) (RY71LU-RY125LU is 7.5 m.) Rated heating capacities are based on the following conditions: Indoor temp., 20¡CDB; outdoor temp., 7¡CDB, 6¡CWB Equiv refrigeration piping, m (horizontal) (RY71LU-RY125LU is 7.5 m.) Anechoic chamber conversion value, measured according to JIS parameters and criteria During operation these values are somewhat higher owing to ambient conditions 50 FLOOR STANDING TYPE CEILING MOUNTED BUILT-IN TYPE 35 FHYB35FV1 Indoor unit Model Name Outdoor unit Power supply Cooling capacity 1a/1b kW Btu/h kcal/h kW Btu/h kcal/h kW kW Heating capacity Cooling 1a/1b Heating Unit Colour Decoration panel m3/min Airflow rate (H) cfm dB(A) Sound level (H/L) mm Dimensions Unit (HXWXD) mm Decoration panel kg Machine weight Unit kg Decoration panel ¡CWB Cooling Certified operation range Heating ¡CDB Colour Compressor Type Motor output kW Power consumption Indoor unit Outdoor unit kg Refrigerant charge (R-22) Sound level (Cooling/Heating) Dimensions (HXWXD) Machine weight Cooling Certified operation range Heating Piping Liquid (Flare) connections Gas (Flare) Drain Indoor unit Outdoor unit Max interunit piping length Max installation level difference Heat insulation dB(A) mm kg ¡CDB ¡CWB mm mm mm mm m m 71 100 125 FHYB71FV1 FHYB100FV1 FHYB125FV1 RY71LUV1 RY100LUV1 RY35FV1A RY50GAV1A RY60GAV1A RY125LUY1 RY100LUY1 RY71LUY1 V1: Phase, 220—240 V, 50 Hz Y1: Phase, 380—415 V, 50 Hz 3.5/3.5 7.8/7.7 10.5/10.4 13.0/12.8 5.0/4.85 6.3/6.15 12,100/11,900 26,600/26,200 35,700/35,300 44,500/43,600 16,900/16,600 21,400/21,000 3,040/3,000 6,700/6,600 9,000/8,900 11,200/11,000 5,390/5,300 4,260/4,200 4.1 7.9 11.2 14.2 5.5 7.1 14,000 27,000 38,100 48,400 18,800 24,200 3,520 6,800 9,600 12,200 6,100 4,750 3.07/3.07 (V1), 3.05/3.05 (Y1) 3.92/3.92 (V1), 3.87/3.87 (Y1) 1.97/1.96 2.91/2.89 1.53/1.52 4.67/4.67 1.92 2.71 1.34 4.63 3.06 (V1), 3.03 (Y1) 3.75 (V1), 3.70 (Y1) -White 14 17 19 27 35 11.5 494 600 670 953 1,235 405 39/34 41/35 41/35 41/35 44/38 38/32 300X700X800 300X1,000X800 300X1,000X800 300X1,400X800 300X1,400X800 300X700X800 55X880X500 55X1,100X500 55X1,100X500 55X1,500X500 55X1,500X500 55X880X500 30 31 41 41 51 52 3.5 3.5 4.5 4.5 6.5 6.5 14 to 23 12 to 25 15 to 28 15 to 27 Ivory white Hermetically sealed rotary type Hermetically sealed scroll type 1.7 2.2 2.24 3.00 3.75 1.3 1.55 1.75 2.8 3.7 3.7 1.12 (Charged for 10 m) (Charged for 10 m) (Charged for m) (Charged for 30 m) (Charged for 30 m) (Charged for 30 m) 47/48 540X750X270 41 o/ 6.4 o/ 12.7 I.D o/ 25XO.D o/ 32 o/ 18.0 (Hole) 20 45 FHYB45FV1 49/51 685X800X300 51 19.4 to 46 -10 to 15.5 o/ 6.4 o/ 15.9 I.Do/ 25XO.Do/ 32 o/ 18.0 (Hole) 15 60 FHYB60FV1 54/54 685X880X350 75 48/49 770X900X320 73 (V1), 72 (Y1) 49/52 49/52 1,170X900X320 1,170X900X320 101 89 (V1), 86 (Y1) -5 to 46 -10 to 15 o/ 6.4 o/ 9.5 o/ 9.5 o/ 9.5 o/ 15.9 o/ 15.9 o/ 19.1 o/ 19.1 I.Do/ 25XO.Do/ 32 I.Do/ 25XO.Do/ 32 I.Do/ 25XO.Do/ 32 I.Do/ 25XO.Do/ 32 o/ 18.0 (Hole) o/ 26.0 (Hole) o/ 26.0 (Hole) o/ 26.0 (Hole) 30 50 (equivalent length 70 m) 30 Both liquid and gas piping WALL MOUNTED TYPE Outdoor unit Power Supply Cooling capacity 1a/1b Heating capacity Power consumption Indoor unit Cooling 1a/1b Heating Colour Airflow rate (H) Sound level (H/L) Dimensions (HXWXD) Machine weight Cooling Certified operation range Heating Colour Outdoor Compressor Type unit Motor output Refrigerant charge (R-22) Sound level (Cooling/Heating) Dimensions (HXWXD) Machine weight Cooling Certified operation range Heating Piping Liquid (Flare) connections Gas (Flare) Drain Indoor unit Outdoor unit Max interunit piping length Max installation level difference Heat insulation 51 Outdoor unit Cooling capacity 1a/1b kW Btu/h kcal/h kW Btu/h kcal/h kW kW 71 FAY71LVE RY71LUV1 RY71LUY1 VE: Phase, 220—240/220 V, 50/60 Hz 7.8/7.7 26,600/26,200 6,700/6,600 7.9 27,000 6,800 2.92/2.92 (V1), 2.90/2.90 (Y1) 2.85 (V1), 2.82 (Y1) m3/min cfm dB(A) mm kg ¡CWB ¡CDB 19 670 43/37 290X1,050X230 13 kW kg dB(A) mm kg ¡CDB ¡CWB mm mm mm mm m m 2.24 2.8 (Charged for 30 m) 48/49 770X900X320 73 (V1), 72 (Y1) o/ 9.5 o/ 15.9 I.Do/ 13XO.Do/ 18 o/ 26.0 (Hole) 100 FAY100FAVE RY100LUV1 RY100LUY1 V1: Phase, 220—240 V, 50 Hz Y1: Phase, 380—415 V, 50 Hz 10.5/10.4 35,700/35,300 9,000/8,900 11.2 38,100 9,600 3.82/ 3.82 (V1), 3.77/ 3.77 (Y1) 3.66 (V1), 3.61 (Y1) White 23 811 45/41 360X1,570X200 26 12 to 25 15 to 27 Ivory white Hermetically sealed scroll type 3.00 3.7 (Charged for 30 m) 49/52 1,170X900X320 89 (V1), 86 (Y1) -5 to 46 -10 to 15 o/ 9.5 o/ 19.1 I.Do/ 20XO.Do/ 26 o/ 26.0 (Hole) 50 (equivalent length 70 m) 30 Both liquid and gas piping Note : Rated cooling capacities are based on the following conditions: (FHYB) 1aSuction temp., 27¡CDB, 19.5¡CWB; outdoor temp 35¡CDB Equiv refrigeration piping, m (horizontal) 1b Suction temp., 27¡CDB, 19.0¡CWB; outdoor temp 35¡CDB Equiv refrigeration piping, m (horizontal) (RY71LU-RY125LU is 7.5 m.) (FAY) 1aIndoor temp., 27¡CDB, 19.5¡CWB; outdoor temp 35¡CDB Equiv refrigeration piping, m (horizontal) 1b Indoor temp., 27¡CDB, 19.0¡CWB; outdoor temp 35¡CDB Equiv refrigeration piping, 7.5 m (horizontal) Rated heating capacities are based on the following conditions: (FHYB) Suction temp., 20¡CDB; outdoor temp., 7¡CDB, 6¡CWB Equiv refrigeration piping, m (horizontal) (RY71LU-RY125LU is 7.5 m.) (FAY) Indoor temp., 20¡CDB; outdoor temp., 7¡CDB, 6¡CWB Equiv refrigeration piping, 7.5 m (horizontal) Anechoic chamber conversion value, measured according to JIS parameters and criteria During operation these values are somewhat higher owing to ambient conditions kW Btu/h kcal/h kW Btu/h kcal/h kW kW Heating capacity Power consumption Indoor unit Cooling 1a/1b Heating Colour Airflow rate (H) Sound level (H/L) Dimensions (HXWXD) Machine weight Cooling Certified operation range Heating Colour Outdoor Compressor Type unit Motor output Refrigerant charge (R-22) Sound level (Cooling/Heating) Dimensions (HXWXD) Machine weight Cooling Certified operation range Heating Piping Liquid (Flare) connections Gas (Flare) Drain Indoor unit Outdoor unit Max interunit piping length Max installation level difference Heat insulation m3/min cfm dB(A) mm kg ¡CWB ¡CDB kW kg dB(A) mm kg ¡CDB ¡CWB mm mm mm mm m m 71 100 FVY71LAVE FVY100LAVE RY71LUV1 RY100LUV1 RY71LUY1 RY100LUY1 VE: Phase, 220—240/220 V, 50/60 Hz V1: Phase, 220—240 V, 50 Hz 7.8/7.7 10.5/10.4 26,600/26,200 35,700/35,300 6,700/6,600 9,000/8,900 7.9 11.2 27,000 38,100 6,800 9,600 3.95/3.95 (V1), 3.90/3.90 (Y1) 3.12/3.12 (V1), 3.10/3.10 (Y1) 3.00 (V1), 2.97 (Y1) 3.75 (V1), 3.70 (Y1) White 18 28 635 988 41/35 46/40 1,850X600X270 1,850X600X350 39 46 12 to 25 15 to 27 Ivory white Hermetically sealed scroll type 3.00 2.24 3.7 (Charged for 30 m) 2.8 (Charged for 30 m) 48/49 49/52 1,170X900X320 770X900X320 89 (V1), 86 (Y1) 73 (V1), 72 (Y1) -5 to 46 -10 to 15 o/ 9.5 o/ 9.5 o/ 19.1 o/ 15.9 I.Do/ 20XO.Do/ 26 I.Do/ 20XO.Do/ 26 o/ 26.0 (Hole) o/ 26.0 (Hole) 50 (equivalent length 70 m) 30 Both liquid and gas piping 125 FVY125LAVE RY125LUY1 Y1: Phase, 380—415 V, 50 Hz 13.0/12.8 44,500/43,600 11,200/11,000 14.2 48,400 12,200 4.99/4.99 4.73 32 1,129 49/43 1,850X600X350 47 3.75 3.7 (Charged for 30 m) 49/52 1,170X900X320 101 o/ 9.5 o/ 19.1 I.D o/ 20XO.D o/ 26 o/ 26.0 (Hole) DUCT CONNECTION LOW STATIC PRESSURE TYPE Indoor unit Model Name Indoor unit Model Name Indoor unit Model Name Outdoor unit Power supply Cooling capacity 1a/1b kW Btu/h kcal/h kW Btu/h kcal/h kW kW Heating capacity Power consumption Indoor unit Cooling 1a/1b Heating Colour Airflow rate (H) Fan Outdoor unit External static pressure Driving system Sound level (H/L) Dimensions(HXWXD) Machine weight Cooling Certified operation range Heating Colour Compressor Type Motor output dB(A) mm kg ¡CWB ¡CDB kW kg Refrigerant charge (R-22) Sound level (Cooling/Heating) Dimensions (HXWXD) Machine weight Cooling Certified operation range Heating Piping Liquid (Flare) connections Gas (Flare) Drain Indoor unit Outdoor unit Max interunit piping length Max installation level difference Heat insulation m3/min cfm Pa(mmH2O) dB(A) mm kg ¡CDB ¡CWB mm mm mm mm m m 35 FDYB35KAVE 50 FDYB50KAVE 60 FDYB60KAVE 71 FDYB71KAVE RY71LUV1 RY35FV1A RY50GAV1A RY60GAV1A RY71LUY1 VE: Phase, 220—240/220 V, 50/60 Hz V1: Phase, 220—240 V, 50 Hz Y1: Phase, 380—415 V, 50 Hz 3.79/3.75 5.27/5.20 6.24/6.15 7.8/7.7 12,900/12,800 18,000/17,800 21,300/21,000 26,600/26,200 3,260/3,230 4,530/4,470 5,370/5,290 6,700/6,600 4.22 5.80 7.0 7.9 14,400 23,900 27,000 19,800 3,630 4,990 6,020 6,800 1.51/1.50 2.01/2.00 2.38/2.36 3.08/3.08 (V1), 3.06/3.06 (Y1) 1.33 1.78 2.29 2.91 (V1), 2.88 (Y1) -13 18 460 635 20 (2) Direct drive (2 speed) 41/ 38 43/40 260X900X580 260X1,300X580 22 23 31 14 to 23 12 to 25 15 to 28 15 to 27 Ivory white Hermetically sealed rotary type Hermetically sealed scroll type 1.3 1.7 2.2 2.24 1.12 1.55 1.75 2.8 (Charged for 10 m) (Charged for 10 m) (Charged for m) (Charged for 30 m) 47/48 540X750X270 41 49/51 685X800X300 51 19.4 to 46 -10 to 15.5 o/ 6.4 o/ 15.9 54/54 685X880X350 75 o/ 6.4 o/ 12.7 o/ 6.4 o/ 15.9 48/49 770X900X320 73 (V1), 72 (Y1) -5 to 46 -10 to 15 o/ 9.5 o/ 15.9 3/4B o/ 18.0 (Hole) 20 o/ 18.0 (Hole) Note : Rated cooling capacities are based on the following conditions: (FVY) 1aIndoor temp., 27¡CDB, 19.5¡CWB; outdoor temp 35¡CDB Equiv refrigeration piping, m (horizontal) 1b Indoor temp., 27¡CDB, 19.0¡CWB; outdoor temp 35¡CDB Equiv refrigeration piping, 7.5 m (horizontal) (FDYB) 1aSuction temp., 27¡CDB, 19.5¡CWB; outdoor temp 35¡CDB Equiv refrigeration piping, m (horizontal) 1b Suction temp., 27¡CDB, 19.0¡CWB; outdoor temp 35¡CDB Equiv refrigeration piping, m (horizontal) Rated heating capacities are based on the following conditions: (FVY) Indoor temp., 20¡CDB; outdoor temp., 7¡CDB, 6¡CWB Equiv refrigeration piping, 7.5 m (horizontal) (FDYB) Suction temp., 20¡CDB; outdoor temp., 7¡CDB, 6¡CWB Equiv refrigeration piping, m (horizontal) Anechoic chamber conversion value, measured according to JIS parameters and criteria During operation these values are somewhat higher owing to ambient conditions o/ 18.0 (Hole) 30 15 o/ 26.0 (Hole) 50 (equivalent length 70 m) 30 Both liquid and gas piping 52 DIMENSIONS (Unit: mm) Indoor unit CEILING MOUNTED CASSETTE TYPE Support for centralised control from else where., using a PC with a Web browser (Optional) Special Function Sending of e-mail alerts to a specified address when malfunctions occur (Optional) Special Function Built-in Ethernet port for connecting to the Internet or an intranet 55 840 55 295 240 Suspension bolt 4-M8 M10 260 270 315 840 80 100=200 85 40 350 Special Function Simple interlock function Unification adapter for computerised control [DCS302A52] Special Function Unified ON/OFF and status monitoring from the central monitoring panel 1500mm or more Required space 1500mm or more 1500mm or more 1500mm or more When the discharge grill is closeout,the required space is 200mm or more A C 14-M4 Hole (prepared hole) 40 50 155 165 40 350 B 230 240 165 FHYC100KVE-140KVE 288 298 195 55 Branch duct connection A Liquid pipe connection Gas pipe connection Drain pipe connection Power supply connection 195 150 Notes: Location of unit’s Name Plate For Main body: Switch Box Cover inside surface of suction grille For decoration panel: Panel frame inside surface of suction grille When installing an optional accessory, refer to the installation drawings For fresh air intake kit Inspection port is necessary For high efficiency filter unit Inspection port is not necessary In case of using wireless remote controller, this position will be a signal receiver Refer to the drawing of wireless remote controller in detail Remote control code and control wiring connection Air discharge grille Air suction grille Port for water supply Corner decoration cover 10 Drain hose CEILING SUSPENDED TYPE Special Function 1120 1160 FHY100BVE 1360 1400 FHY125BVE 1550 1590 KIS95 RG71A RG140A RG180A R71LU R100LU R125LU R140LU KIS95 - KKPJ5F180 - KPW937A4 KKP937A4 - KHR58C21 KHD58C21A - RY35F RY50G(A) R60G(A) KHD58D33 KRK5F80V1 KRK5F140V1 KRK5F160V1 - RY71LU RY100LU RY125LU RY140LU KKPJ5F180 KHR58C21 KHD58C21A KHD58D33 - Note: 1One set includes pieces for 5units A (Hanging position) Hanging bolt 4-M8~M10 Position : Hole of wall for taking out in piping back (View from the front) 90 155 300 or more 55 (Required space) 13 Kit name Cooling only For twin multi For triple multi For double twin multi R200KU KHD58C23A KHR58P322H KHRJ5F224F R250KU KHD58C24A KHRJ5F280F Heat pump RY250KU RY200KU KHD58C23A KHD58C24A KHR58P322H KHRJ5F224F KHRJ5F280F 80 11 40 195 680 B 30 or more (Service space) 30 or more (Service space) o/ 45 55 14 The Front Obstacle Floor side Brand name plate (Note.2) Drain pipe connection VP20 (For left piping) 80 Remark 105 15 225 275 - R71FU R100FU R125FU 10 300 275 Heat pump For height installaion Touch Controller Kit name R35G R50G R60G 65 60 Necessary for optional interface adaptor for SkyAir series (DTA112BA51) with the Cooling only 50 Position slit hole for taking out in piping back (View from the front) 127 HRV (Required space) D -NET Plus Adapter Indoor Unit (option) [DCS601A52] 145 60 115 60 FHY71BVE 12 85 102 160 185 192 36 FH(Y)60BVE 1120 1160 Number of indoor unit expanded from 64 to 128 R25J R35J 170 105 90 18 17 16 142 58 65 960 135 920 40 FH(Y)50BVE From the floor side 2500 or more 155 Trouble reports Outdoor unit Drain piping kit Central drain plug Air direction adjustment grille Drain plug Refrigerant branch piping For twin multi For triple multi Year-round cooling kit 960 Special Function Mobile Phone * Limitations apply to some models and functions For details please contact your local sales office Remark B 920 135 (Required space) D -NET A FH(Y)35BVE 210 ¥ Connection to power consumption metre when using power proportional distribution function (Optional) Forced OFF command from fire alarm monitoring panel 260 Pi Port Trouble reports Colour LCD Touch panel Icon display Multilingual (English, French, German, Spanish, Italian, or Chinese) 59 Branch duct connection 840 80 100=200 85 (Hanging position) Forced OFF contact input Special Function Labor saving Overall energy savings Simplified BMS Refrigerant branch piping 12-M4 Hole (prepared hole) Remote monitoring and control RS-232C Name of option 55 [FHYC100KVE-140KVE] DCS601C51 Yearly schedule Power proportional distribution* (option) Auto cool/heat change-over Temperature Limitation Name of option For fresh air intake kit connection (direct installation type) B view Required space [FH(Y)C35KVE-71KVE] 55 FH(Y)C35KVE-71KVE PCMCIA Flash Memory Special Function 80 B 1000 or more Required space Special Function 60 160 420 A New communication functions in the user-friendly icon based multilingual controller simplity centralised control of the system ¥ CSV output of power proportional distribution results (Optional) C view 4-4M4 Hole (prepared hole) 75 55 Doubling of number of connectable indoor unit by adding a D -NET PLUS adapter (Optional) Branch duct connection A view Note: This optional accessory requires DTA102A52 This optional accessory requires DTA107A55 This optional accessory requires KRP1B100 Installation plate for adaptor PCB (KRP4A95) is necessary In case of using KRC17-2B or field supplied remote controller, 3-Minutes Timer (field supplied) is required Special Function C 165 155 40 350 80 BRC1C61 BRC4C62 DCS302CA611 DCS301BA611 DST301BA611 DCS601C511 KRP1BA573 KRP4AA533 DTA102A52 KRP1B100 - 780 Suspension position 860~890 Ceiling opening 10 95 110 BRC1C61 BRC4C62 DCS302CA611 DCS301BA611 DST301BA611 DCS601C511 KRP4AA514 DTA102A52 - BRC1D61 - 80 100=200 85 150 BRC1C61 BRC4C64 DCS302CA611 DCS301BA611 DST301BA611 DCS601C511 KRP4AA514 DTA102A52 - 300 or less 950 KRC47-2A KRC47-4A - KRC47-3A KRC47-3A/ KRC17-2B KRC47-5 DCS302CA612 DCS301BA612 DST301BA612 DCS601C512 KRCS01-1B DTA107A55 - BRC1D61 - 950 860~890 Ceiling opening 680 Suspension position 420 125 150 B BRC1C61 KRC47-2A KRC47-4A BRC4C62 DCS302CA611 DCS301BA611 DST301BA611 DCS601C511 KRP1BA54 KRP4AA52 KRP1B100 DTA102A52 KDGF19A45 KDGF19A71 KDGF19A45 KDGF19A71 KKD19A1 KKD19A1 BRC1D61 - 750 Wired LCD remote controller Digital remote controller Digital remote controller for duct heater use Wireless remote controller Central remote controller Unified ON/OFF controller Schedule timer intelligent Touch Controller Remote sensor (for indoor temperature) Central control adaptor kit Adaptor for wiring Wiring adaptor for electrical appendices Switch box for adaptor kit Interface adaptor for SkyAir series Installation box for adaptor PCB Suction grille Drain pan cover KRC47-1A BRC1D61 - Note3 06K/08K/ 10K Adjustable(0~550) KRC47-1A Wired LCD remote controller with weekly schedule timer Remote controller C 200 Remark 40 A 30 10 Name of option High static pressure type Heat pump Cooling only FD03K/ FD15K/ FDY06KA/08KA/ 04K/05K/ 20K 10KA/15KA/20KA Middle static pressure type Heat pump Cooling only FDMG71A/ FDYM03FA/ FDYM03FA/ 100A/125A/ 04FA/05FA/ 04FA/05FA/ 140A/180A 06FA 06FA Low static pressure type Heat pump Cooling only FDBG25A/ FDBG60A/ FDYB35KA/ FDYB60KA/ 35A/50A 71A 50KA 71KA 1000 or more Required space 165 DUCT CONNECTION TYPE Notes: Location of unit’s Name Plate: Bottom of fan housing inside the suction grille In case of using wireless remote controller, this position will be a signal The remote control code is the standard attached (0.5 mm2 wicks O.D 5.4) (It is attached to VRV.) 80 105 170 Air discharge grille Air suction grille Air filter Gas pipe connection Liquid pipe connection Drain pipe conneciton Earth terminal (inside the electric components box) (M4) Suspension bracket Backward piping and wiring connection opening lid 10 Upward piping and wiring connection opening lid 11 Right side pipe connection 12 Left back drain pipe connection 13 Left side drain pipe connection 14 Right side drain pipe connection 15 Hole of wall for taking out in piping back 16 Upward drain pipe connection 17 Upward gas pipe connection 18 Upward liquid pipe connection 60 ... controller for duct heater use Wireless remote controller Central remote controller Unified ON/OFF controller Schedule timer intelligent Touch Controller Remote sensor (for indoor temperature)... drawing of wireless remote controller in detail Remote control code and control wiring connection Air discharge grille Air suction grille Port for water supply Corner decoration cover 10 Drain hose... Central control adaptor kit Adaptor for wiring Wiring adaptor for electrical appendices Switch box for adaptor kit Interface adaptor for SkyAir series Installation box for adaptor PCB Suction grille

Ngày đăng: 29/11/2017, 04:27

Tài liệu cùng người dùng

Tài liệu liên quan