Review Mode 2010-04-21 ©SKF Slide [Code] SKF [Organisation] Module Objective(s) To instruct the new GX Series Microlog user on how to review previously collect ROUTE and Non ROUTE measurement results on the Microlog 2010-04-21 ©SKF Slide [Code] SKF [Organisation] Review Mode Overview • Provides opportunity to review measurement results in the field • Opens in ROUTE Review mode, defaults to active ROUTE hierarchy • Uses same hierarchy navigation procedures and data display features as ROUTE mode, except no coded notes option 2010-04-21 ©SKF Slide [Code] SKF [Organisation] Review Mode Function Buttons indicates active POINT has FFT data 2010-04-21 ©SKF Slide [Code] SKF [Organisation] indicates active POINT has overall/process data shift functions review Non ROUTE and Delete collected data for highlighted POINT Reviewing Spectral Data if applicable, view POINTs time waveform data 2010-04-21 ©SKF Slide [Code] SKF [Organisation] return to POINTs FFT data display Cursor / Analysis Features Apply Y-axis scaling H key - display harmonic markers T key – phase “tables” P key - jump to next peak “.” key – immed toggle between display expansion and display compression 2010-04-21 ©SKF Slide [Code] SKF [Organisation] +/- key – display expansion / compression Reviewing MPA POINTs • Press FFT button on first MPA POINT, spectrum displays • Use Next / Previous buttons to view data for other POINTs in MPA group • Press Esc to return to Review mode’s hierarchy show next MPA POINT’s data 1st MPA POINT’s spectrum 2010-04-21 ©SKF Slide [Code] SKF [Organisation] How to Review Process (Overall) Measurements • Review stored process measurement data in overall screen format • Uses same data display features as ROUTE mode, except no coded notes option 2010-04-21 ©SKF Slide [Code] SKF [Organisation] Reviewing Non ROUTE Data • Review Non ROUTE is a shifted function button • Non ROUTE POINTs list by sequential numerical names • Press Enter on POINT name to view data display • Uses same data display features as ROUTE mode (P, H, +/-, etc.), except no coded notes option view the measurement’s Pt Info screen 2010-04-21 ©SKF Slide [Code] SKF [Organisation] Quick Review 2010-04-21 ©SKF Slide 10 [Code] SKF [Organisation] ...Module Objective(s) To instruct the new GX Series Microlog user on how to review previously collect ROUTE and Non ROUTE measurement results