1. Trang chủ
  2. » Kỹ Thuật - Công Nghệ

Distrubuted control system training Part 5

71 531 0

Đang tải... (xem toàn văn)

Tài liệu hạn chế xem trước, để xem đầy đủ mời bạn chọn Tải xuống

THÔNG TIN TÀI LIỆU

Cấu trúc

  • Slide 1

  • Slide 2

  • Slide 3

  • Slide 4

  • Slide 5

  • Example of Graphic builder

  • Slide 7

  • Slide 8

  • Slide 9

  • Slide 10

  • Slide 11

  • Creating Builder (.edf) Files

  • Window operation and monitoring authority

  • Parts of the Graphic builder

  • Slide 15

  • Slide 16

  • Slide 17

  • Slide 18

  • Slide 19

  • Setting the Cavas Properties (Image)

  • Setting the Cavas Properties (Image)

  • Setting the Cavas Properties (Image)

  • Layer Window Pane

  • Inserting Objects from the Home Tab

  • Inserting Objects from the Stencil Area

  • Objects properties - general

  • Objects properties - Line

  • Objects properties - Fill

  • Buttons and Data Display Properties

  • Buttons and Data Display Properties

  • Buttons and Data Display Properties

  • Buttons and Data Display Properties

  • Buttons and Data Display Properties

  • Buttons and Data Display Properties

  • Buttons and Data Display Properties

  • Buttons and Data Display Properties

  • Buttons and Data Display Properties

  • Buttons and Data Display Properties

  • Assigning Function- call window

  • Buttons and Data Display Properties

  • System Function Keys

  • System Function Keys

  • System Function Keys

  • System Function Keys

  • Buttons and Data Display Properties

  • Buttons and Data Display Properties

  • Buttons and Data Display Properties

  • Buttons and Data Display Properties

  • Buttons and Data Display Properties

  • Buttons and Data Display Properties

  • Buttons and Data Display Properties

  • Buttons and Data Display Properties

  • Buttons and Data Display Properties

  • Buttons and Data Display Properties

  • Buttons and Data Display Properties

  • Buttons and Data Display Properties

  • Buttons and Data Display Properties

  • Creating new Stencil

  • Creating new Stencil

  • Creating new Linked Part

  • Creating New Linked Part

  • Modify Existing Linked Part

  • Save Linked Part

  • Custom Face Plate (1)

  • Custom Face Plate (2)

  • Custom Face Plate (3)

  • Custom Face Plate (4)

  • Aligning tag data and engineering units

  • Aligning tag data and engineering units

  • THANK YOU FOR YOUR ATTENTION!

  • Slide 71

Nội dung

June 2012 Yokogawa Electric Corporation YOKOGAWA VIETNAM CO.LTD Copyright © Yokogawa Electric Corporation SERVICE DEPARTMENT ENGINEERING COURSE Yokogawa Vietnam Co Ltd Service Department YOKOGAWA VIETNAM CO.LTD Copyright © Yokogawa Electric Corporation SERVICE DEPARTMENT ENGINEERING Schedule for the day: Day Graphics Generation YOKOGAWA VIETNAM CO.LTD Copyright © Yokogawa Electric Corporation SERVICE DEPARTMENT INTRODUCTION The Graphic Generation Guide provides general specifications, detailed information and steps on how to generate graphic window using CENTUMVP Graphic Builder This document discuss specific functions of the Graphic Builder menus, tools and properties This document is composed of the following chapters: • • • • • Input documents for Graphic generation Graphic Worksheet (optional) Graphic Builder Graphic Window Display Graphic Linked Parts OKOGAWA VIETNAM CO,LTD Copyright © Yokogawa Electric Corporation ERVICE DEPARTMENT Example of Graphic builder YOKOGAWA VIETNAM CO.LTD Copyright © Yokogawa Electric Corporation SERVICE DEPARTMENT Example of Graphic builder Ribbon Pan & Zoom pane Canvas pane Layer Window pane Output Area pane Property Grid pane YOKOGAWA VIETNAM CO.LTD Copyright © Yokogawa Electric Corporation SERVICE DEPARTMENT Graphic Builder Mode Engineering Mode Start directly from System view or from other Builder in SW Standalone Mode Start as an individual application from the Window Start Menu OKOGAWA VIETNAM CO,LTD Copyright © Yokogawa Electric Corporation ERVICE DEPARTMENT Graphic Builder Mode Function Engineering Mode Standalone Builder file (.edf) Working file (.wkf) Standalone file (.sva) Standalone file (.sva) Linked part files (.lpx) Opening Graphic files Linked Part files (.lpx) Download file to HIS Supported Checking the existence of function blocks and User can specify whether to perform the windows when saving to a file checking Saving a working file Supported OKOGAWA VIETNAM CO,LTD Copyright © Yokogawa Electric Corporation ERVICE DEPARTMENT Not Supported Checking is not performed Not Supported Capacity of Graphic View Capacity CENTUM VP Communication Data 400data/view (Data links) conditions per Object Modifier Condition 200 per view OKOGAWA VIETNAM CO,LTD Copyright © Yokogawa Electric Corporation ERVICE DEPARTMENT Faceplate Window 16 Faceplate per window Touch Targets 400 per View Graphs Graphs / view Generics Name Sets 200 per view Components 1500 per view Graphic Builder File Types  Builder File The builder files are the master files of graphic builder The extension for this type of file is edf This type of file can be edited in engineering mode only  Standalone File When the created graphic file has conflict contents with the builder settings, the builder will display an error and refuse to save and download the graphic file Under this circumstance, you can save the file using this type with a different name the extension for this type of file is sva You can edit this file on graphic builder by importing the sva file on the graphic builder  Linked parts files The linked part files are the files of the objects of Graphic View The objects can be simply used as graphical components for creating a graphic file The object and the linked part files are closely linked, when you revise the object of the linked part file, the object use in graphic file will change to follow the revision  Working files A current created or edited graphic file can be save as a working file (.wkf) A working file can be created even the file contents conflict with builder settings The working file can be edited only in engineering mode OKOGAWA VIETNAM CO,LTD Copyright © Yokogawa Electric Corporation ERVICE DEPARTMENT Buttons and Data Display Properties Function Type: others parameter: enter program syntax example: F MSPaint.exe Push Button & Touch Target Others YOKOGAWA VIETNAM CO.LTD Copyright © Yokogawa Electric Corporation SERVICE DEPARTMENT (opens the Microsoft Paint) Creating new Stencil Click YOKOGAWA VIETNAM CO.LTD Copyright © Yokogawa Electric Corporation SERVICE DEPARTMENT Creating new Stencil Specify stencil Name Stencil Name YOKOGAWA VIETNAM CO.LTD Copyright © Yokogawa Electric Corporation SERVICE DEPARTMENT Creating new Linked Part Drag and Drop YOKOGAWA VIETNAM CO.LTD Copyright © Yokogawa Electric Corporation SERVICE DEPARTMENT Creating New Linked Part YOKOGAWA VIETNAM CO.LTD Copyright © Yokogawa Electric Corporation SERVICE DEPARTMENT Modify Existing Linked Part YOKOGAWA VIETNAM CO.LTD Copyright © Yokogawa Electric Corporation SERVICE DEPARTMENT Save Linked Part YOKOGAWA VIETNAM CO.LTD Copyright © Yokogawa Electric Corporation SERVICE DEPARTMENT Custom Face Plate (1) How to create 1.Create the graphic window 2.Save the graphic file (same as other graphics) ・ Specified “$CFPTAG” to the tag name in builder (Generic name) ・” $CFPTAG” is replace to actual tag when it was call on HIS 3.Save to for custom face plate folder by using “Save as” command 4.Select the save folder CENTUMVP/his/spconf/cfp The rule of file name: ・ Tagname.sva (1FIC200.sva) for specific tag name ・ PID.sva for specific function block type Note: 1.Custom faceplate file is only available on own HIS If you want to use it on other HIS, you must copy the same to other HIS manually 2.Height of Custom face plate, it must create less than height of resolution YOKOGAWA VIETNAM CO.LTD Copyright © Yokogawa Electric Corporation SERVICE DEPARTMENT Custom Face Plate (2) YOKOGAWA VIETNAM CO.LTD Copyright © Yokogawa Electric Corporation SERVICE DEPARTMENT Custom Face Plate (3) Click Click the the “Save “Save as” as” YOKOGAWA VIETNAM CO.LTD Copyright © Yokogawa Electric Corporation SERVICE DEPARTMENT Custom Face Plate (4) Example of Custom faceplate Mode change button Trend window Call the tuning window Data bar (SV, MV, OPLO, OPHI) Data bar (PV) Data entry window (INC/DEC type) Photo display YOKOGAWA VIETNAM CO.LTD Copyright © Yokogawa Electric Corporation SERVICE DEPARTMENT Aligning tag data and engineering units Engineer can control the aligning of tag data and engineering data Option Left Description Example Displays data and engineering Option Description Right Tight Aligns data and engineering units to the right Compact Displays data and engineering Center units in columns, and aligns data units in columns, and aligns data and engineering units to the left of their respective columns Left Tight Aligns data and engineering units to the left to the right of its column, and the engineering unit to the left of its column Note that this is the default option Center Displays data and engineering Distributed units in columns, and aligns units in columns, and aligns data data and engineering to the left of its column, and the units to the center of their engineering unit to the right of respective columns Right Displays data and engineering its column Aligns data and engineering units to the right Note: Compact center is default setting YOKOGAWA VIETNAM CO.LTD Copyright © Yokogawa Electric Corporation SERVICE DEPARTMENT Proprietary info goes here… Page 68 Example Aligning tag data and engineering units Right Center Left Compact Center YOKOGAWA VIETNAM CO.LTD Copyright © Yokogawa Electric Corporation SERVICE DEPARTMENT Proprietary info goes here… Page 69 End of presentation THANK YOU FOR YOUR ATTE NTION! YOKOGAWA YOKOGAWA VIETNAM VIETNAM CO,LTD CO.LTD Copyright © Yokogawa Electric Corporation SERVICE SERVICE DEPARTMENT DEPARTMENT Working OKOGAWA VIETNAM CO,LTD Copyright © Yokogawa Electric Corporation ERVICE DEPARTMENT ... Copyright © Yokogawa Electric Corporation SERVICE DEPARTMENT ENGINEERING Schedule for the day: Day Graphics Generation YOKOGAWA VIETNAM CO.LTD Copyright © Yokogawa Electric