1. Trang chủ
  2. » Kỹ Thuật - Công Nghệ

Distrubuted control system training Part 1

89 704 0

Đang tải... (xem toàn văn)

Tài liệu hạn chế xem trước, để xem đầy đủ mời bạn chọn Tải xuống

THÔNG TIN TÀI LIỆU

Thông tin cơ bản

Định dạng
Số trang 89
Dung lượng 19,23 MB

Nội dung

June 2012 Yokogawa Electric Corporation YOKOGAWA VIETNAM CO.LTD Copyright © Yokogawa Electric Corporation SERVICE DEPARTMENT CENTUM VP Engineering Course Yokogawa Vietnam Co Ltd Service Department Email: Anh.DuongThiVan@vn.yokogawa.com YOKOGAWA VIETNAM CO.LTD Copyright © Yokogawa Electric Corporation SERVICE DEPARTMENT CENTUM VP Engineering Course Schedule for the day: Session Starts: 8:00 – 9:30 am Tea Break: 9:30 – 9:45 am Lunch: 12:00 – 1:00 pm Session Resume: YOKOGAWA VIETNAM CO.LTD Copyright © Yokogawa Electric Corporation SERVICE DEPARTMENT 1:00 – 3:00 Tea Break: 3:00 – 3:15 pm Sessions Ends: 4:00 pm pm Course Contents CENTUM VP Engineering Course Day Centum VP System specifications Project Creation and Attribution Utility Project Common Definition Day FCS Configuration I/O Module Configuration Software Switches Configuration Message Configuration Control Drawing Builder YOKOGAWA VIETNAM CO.LTD Copyright © Yokogawa Electric Corporation SERVICE DEPARTMENT Course Contents CENTUM VP Engineering Course Day Regulatory Control Function Sequence Control Function Day HIS Configuration Window Configuration Day Graphic Builder YOKOGAWA VIETNAM CO.LTD Copyright © Yokogawa Electric Corporation SERVICE DEPARTMENT What is CENTUM VP CENTUM VP is the integrated production control system to achieve the safe, reliable, and optimum plant operation for various industries YOKOGAWA VIETNAM CO.LTD Copyright © Yokogawa Electric Corporation SERVICE DEPARTMENT 37 years History and the continuity Dual redundant Token-passing bus for our DCS since 1975 as reliable & robust control bus 2008 2011 CENTUM VP 2001 CENTUM VP R5 2005 CENTUM CS 3000 R3 1998 CENTUM CS 3000 1993 Dual Redundant Vnet/IP CENTUM CS 10 MBPS 1983 1MBPS Dual HIS Dual HIS ICS 1Gbps AVR PICS EWS Token Pass V net HIS FFCS NFCS Redundant 1988 CENTUM-XL CENTUM V ABC ENGS Redundant Token Pass LFCS COPS2 COPSV HF-Bus PFCS FFCS KFCS EOPS 1975 CENTUM CFCS2 CFFS COPS CFCD2 CFCS EFCD • F-Bus CENTUM series has been keeping the operation continuity and the application compatibility for customers to use the CENTUM continuously for a long term 250 KBPS Dual Redundant Token Pass CFCS CFCD YOKOGAWA VIETNAM CO.LTD Copyright © Yokogawa Electric Corporation SERVICE DEPARTMENT • 20,000 + systems have been installed worldwide Yokogawa DCS Evolution YOKOGAWA VIETNAM CO.LTD Copyright © Yokogawa Electric Corporation SERVICE DEPARTMENT Centum Capacity System Centum VP Max no of tags 100 000 (When using LHS4000, up to 1,000,000 per system) Max no of stations 256 Max no of domains 16 Max no of stations per domain 64 (HIS (16) , FCS, BCV, CGW) HIS : Human Interface Station FCS : Field Control Station BCV : Bus Converter YOKOGAWA VIETNAM CO.LTD CGW : Communication Gateway Copyright © Yokogawa Electric Corporation SERVICE DEPARTMENT Page.9 Features of CENTUM VP     Scalability and flexibility – CENTUM VP meets both simple small scale systems and 1,000,000 tag level huge scale systems – CENTUM VP is applicable for various types of applications and for various system architectures Super-high plant operation availability – Seven 9’s (99.9999959) hardware availability – Pair & Spare technology to keep higher control loop availability Operators’ perspective design – Real-time plant operation environment – Intuitive look & feel HMI design Open Architecture – The latest technologies can be applied in the control systems – Easy integration with other subsystems YOKOGAWA VIETNAM CO.LTD Copyright © Yokogawa Electric Corporation SERVICE DEPARTMENT Security Builder – Window Monitoring OFFUSER YOKOGAWA VIETNAM CO.LTD Copyright © Yokogawa Electric Corporation SERVICE DEPARTMENT ONUSER ENGUSER Properties of Function Block FIC100 Security Builder – Window Operation OFFUSER ONUSER ENGUSER Users with S3 rights can write data to Block mode, SV and MV, but users with S2 rights cannot write data to Block mode, SV and MV YOKOGAWA VIETNAM CO.LTD Copyright © Yokogawa Electric Corporation SERVICE DEPARTMENT User Name & User Switching YOKOGAWA VIETNAM CO.LTD Copyright © Yokogawa Electric Corporation SERVICE DEPARTMENT Privilege Level YOKOGAWA VIETNAM CO.LTD Copyright © Yokogawa Electric Corporation SERVICE DEPARTMENT Automatic User Time-Out YOKOGAWA VIETNAM CO.LTD Copyright © Yokogawa Electric Corporation SERVICE DEPARTMENT User Group Users group classified into groups based on their operation and monitoring authorities/Scopes The following attributes are assigned to each user group: User group name, Operation scope, Operation and monitoring scope, Windows scope, Confirmation operation scope, Messaging scope, Comment YOKOGAWA VIETNAM CO.LTD Copyright © Yokogawa Electric Corporation SERVICE DEPARTMENT Valid User Valid User classified into User name based on their users group of operation and monitoring authorities/scopes Users can be defined to automatic user out time, the users automatically changes to OFFUSER when automatic user out time elapsed YOKOGAWA VIETNAM CO.LTD Copyright © Yokogawa Electric Corporation SERVICE DEPARTMENT Operation Mark Builder Tag Label: Up to single-byte characters can be entered as the text on the label (string) The operation mark label maybe temporarily changed during the operation on the HIS Setup window YOKOGAWA VIETNAM CO.LTD Copyright © Yokogawa Electric Corporation SERVICE DEPARTMENT Operation Mark: Privilege level & Color Privilege Level: The privilege level required for a user to attach/remove the operation mark Tag Level write access right on function blocks can be changed Colors: The following colors maybe used on operation Marks and maybe temporarily changed on the HIS Setup window YOKOGAWA VIETNAM CO.LTD Copyright © Yokogawa Electric Corporation SERVICE DEPARTMENT Project Common Item Definition Engineering Unit Symbol Builder Up to 256 engineering unit symbols can be used for one project Engineering Unit symbols nos 1-8 cannot be changed or deleted Default values are from nos 9-126 The following symbol cannot be used to define engineering unit: @, /, (‘),(“), (,) and # YOKOGAWA VIETNAM CO,LTD Copyright © Yokogawa Electric Corporation SERVICE DEPARTMENT Alarm Priority Builder - Alarm Action The alarm processing level is defined for each function block The output operation for each alarm priority can be selected YOKOGAWA VIETNAM CO.LTD Copyright © Yokogawa Electric Corporation SERVICE DEPARTMENT Alarm Priority Builder - Rewarning YOKOGAWA VIETNAM CO.LTD Copyright © Yokogawa Electric Corporation SERVICE DEPARTMENT Alarm Processing Table Alarm Processing Level Numbers: 1- System fixed - High Low - Alarm Logging – 16 User defined - High - Medium - Low - Alarm Logging - Reference Alarm YOKOGAWA VIETNAM CO.LTD Copyright © Yokogawa Electric Corporation SERVICE DEPARTMENT - Medium - System-fixed Status Character String Viewer/ Alarm Processing Table/ Alarm Priority 1- System fixed Alarm Status Bit Positions YOKOGAWA YOKOGAWA VIETNAM VIETNAM CO.LTD CO,LTD Copyright © Yokogawa Electric Corporation SERVICE SERVICE DEPARTMENT DEPARTMENT – 16 User defined End of Presentation THANK YOU FOR YOUR ATTENTION YOKOGAWA YOKOGAWA VIETNAM VIETNAMCO.LTD CO.LTD Copyright © Yokogawa Electric Corporation SERVICE SERVICEDEPARTMENT DEPARTMENT ... BUS 1: 17 2 .16 DD.SS BUS 2: 19 2 .16 8. [12 8+DD] [SSx2] HIS 015 6 Domain Station 56 Network Address: BUS 1: 17 2 .16 1. 56 BUS 2: 19 2 .16 8 .12 9 .11 2 HIS0324 Domain Station 24 Network Address: BUS 1: 17 2 .16 ... 3.24 BUS 2: 19 2 .16 8 .13 1.48 HIS0234 Domain Station 34 Network Address: BUS 1: 17 2 .16 2.34 BUS 2: 19 2 .16 8 .13 0.68 Alternate Addressing for BUS 2: 19 2 .16 8. [12 8+DD] [12 8+DD+SS] YOKOGAWA... system configuration or equipment installation location Connection Cable Standard Transmission Rate Max Distance 10 00BASE-T 1GBps 10 0m 10 00BASE-T 1GBps 10 0m 10 00BASE-LX 1GBps 5km 10 00BASE-T 1GBps

Ngày đăng: 05/03/2017, 16:32

TỪ KHÓA LIÊN QUAN