Allen-Bradley offers the broadest selection of drive and motor packages designed for optimum variable-speed performance, service life and value. These Control-Matched drive and motor packages are a result of the practi- cal application of advanced electrical/electronic technology – backed by decades of application experience in virtually every industry. For additional information refer to our web site: www.controlmatched.com Control-Matched TM Drives and Motors For Optimum Variable-Speed Value www.rockwellautomation.com Corporate Headquarters Rockwell Automation, 777 East Wisconsin Avenue, Suite 1400, Milwaukee, WI, 53202-5302 USA, Tel: (1) 414.212.5200, Fax: (1) 414.212.5201 Headquarters for Dodge and Reliance Electric Products Americas: Rockwell Automation, 6040 Ponders Court, Greenville, SC 29615-4617 USA, Tel: (1) 864.297.4800, Fax: (1) 864.281.2433 Europe/Middle East/Africa: Rockwell Automation, Herman-Heinrich-Gossen-Strasse 3, 50858 Köln, Germany, Tel: 49 (0) 2234 37941252, Fax: 49 (0) 2234 3794164 Asia Pacifi c: Rockwell Automation, Level 14, Core F, Cyberport 3, 100 Cyberport Road, Hong Kong, Tel: (852) 2887.4788, Fax: (852) 2508.1846 Headquarters for Allen-Bradley Products, Rockwell Software Products and Global Manufacturing Solutions Americas: Rockwell Automation, 1201 South Second Street, Milwaukee, WI 53204-2496 USA, Tel: (1) 414.382.2000, Fax: (1) 414.382.4444 Europe/Middle East/Africa: Rockwell Automation SA/NV, Vorstlaan/Boulevard du Souverain 36, 1170 Brussels, Belgium, Tel: (32) 2 663 0600, Fax: (32) 2 663 0640 Asia Pacifi c: Rockwell Automation, Level 14, Core F, Cyberport 3, 100 Cyberport Road, Hong Kong, Tel: (852) 2887 4788, Fax: (852) 2508 1846 This material is not intended to provide operational instructions. Appropriate Rockwell Automation instruction manuals and precautions should be studied prior to installation, operation or maintenance of equipment. Copyright © 2005 Rockwell Automation, Inc. All rights reserved. Printed in USA. RAPS-1348 3/05-7.5M-K Allen-Bradley Control Matched Motor Catalog Allen-Bradley Control Matched Motor Catalog March 2005 NOTES 1 F-1 mounting 2 1.0 Service Factor 3 Not suitable for use on motors with model number with a, b, or c suffi xes 4 Wye start, Delta run 5 Belted duty only, roller bearing 6 F-2 mounting 7 Companion voltages not available 8 TENV motors are capable of 20:1 speed range operation on drives with no back diode. 9 Motors are not NAFTA qualifi ed 10 These motors meet the hardware requirements of IEEE 45/ABS and are not provided with Marine Plan Documentation 11 Price includes XT features and explosion proof prices include drain on drive end 12 Does not meet NEMA BA for C-Face Footed Motors 13 Furnished without conduit box. Order kit P/N K56G3230 14 Type CH 15 Motors rated 208 - 230/460 are operable to minimum 200 volts 16 Standard TENV motor with standard lead length 17 Class B insulation, 1.0 service factor 18 Class B insulation, 1.25 service factor 19 Class B insulation, 1.35 service factor 20 Class F insulation 21 Double bolt 22 Base used for NEMA & above NEMA frames, 445T 23 Two piece slide rails 24 Includes terminal board 25 Production only after stock depleted. To be superseded by V*S Master Motor 26 See OMS 27 Kits include textile fan cover with drip cover mounted. Suitable for TEFC or TEFC-XT foot and footless design only (not XP or O 28 5.5 inch frame - Aluminum end shield standard enclosure 29 6.3 inch frame - Aluminum end shield standard enclosure 30 Motors usable on 208 volts @ specifi ed amps 31 Suitable for 230/460, 60Hz and 190-220/380-440 volts, 50Hz 32 Stearns brake 33 Reliance AC brake 34 Dodge D series brake 35 Design A, also meets Design E inrush limits 36 1.0 Service factor when operated at 50Hz 37 Derate horsepower 20% when operated at 50hz 38 Consists of sleeve and key to convert 1/2 shaft to 5/8 shaft 39 Coupled Duty only, TS shaft 40 Includes tachometer, stab shaft and mounting hardware 41 Will mount any tachometer having standard NEMA 56 C-face and shaft extension 42 DODGE Short Series Brake 43 Cannot be mounted vertically 44 Scrambler drive - DC integrated control and motor product 45 Maximum value 46 No key - 1.25 long fl at 47 BA dimension does not meet NEMA standards 48 Includes phase insulation. Suitable for inverter duty 49 Includes vertical lifting provision 50 Cast Iron 140 Frame 51 BISSC certifi ed 53 Mounting hole diameter 54 For single phase ratings: O = 7.31: Z = 12.80 55 Refer to previous dimension pages 56 48 through 140T frame ratings are typical full load effi ciency, not nominal effi ciency 57 56 through 140T frame performance data is valid for TENV or TEFC. 180T and larger frame performance data is valid for TEFC ONLY 59 FLA includes harmonic content from PWM power supply 61 TENV motors have a constant torque speed range from 0 to base speed 62 TENV motors have provisions for tachometer mounting as standard 65 Will fi t standard effi cient F model numbers ONLY 71 Nominal effi ciency is base at the 1800 RPM (High RPM) and low speed effi ciency is available just not published 72 Orders shipped from a Rockwell Automation facility in 5 working days. Motor is returnable for a restocking charge of $100 plus 73 Can only be used on motors 1800 RPM and slower with ball bearings 75 Availability limited to current stock 77 Buying motors not manufactured by Rockwell Automation may cause loss of sleep 79 Motor mounted blower is located on drive end 80 Motor has thermostat and provisions for adding fl ange mtd. tach 81 Motor has thermostat and provisions for adding adapter mtd. tach 82 Motor is force ventilated and supplied with blower, and fi lter. 83 May be operated on 50 Hz rectifi ed power supply with full nameplate rating. AC supply voltage must be same as 60 Hz supply; i.e 84 May be operated on 50 Hz rectifi ed power supply with full nameplate rating only when motor is force ventilated with motor mount 85 Cannot be operated at full nameplate rating on 50 Hz rectifi ed power supply 86 Winder Duty - 100% load for 1 minute at 3000 RPM, straight shunt design. Includes blower without fi lter. Tachometer is rated at 87 Motor has thermostat and provision for adding integral AC or DC tachometer or adapter mounted tachometer. 88 Motor is force ventilated and supplied with blower. 89 Motor is force ventilated and supplied with single-phase blower motor rated 1/3 HP, 3450/2850 RPM, 115/230 volts, 60/50 Hz. 90 Includes thermostat 91 Includes Dynapar H20 1024 PPR encoder with mating 10 pin MS connector. Requires 2-7 business days. 92 Blower is piggyback mounted on L440 frames 93 180TC NEMA fl ange size, see appropriate dimension sheet. 94 210TC NEMA fl ange size, see appropriate dimension sheet 95 250TC NEMA fl ange size, see appropriate dimension sheet 96 See appropriate dimension sheet for fl ange size 99 Highlighted for Marketing Review 100 Ball bearing only 101 Not available for Easy Clean product line 102 Not available for XT enclosures 103 Not available for Non-NAFTA motors 104 Not available for 841 XL motors 105 Not available on SABRE and CALIBRE product lines 106 Finned aluminum frame construction 107 Not available on belted duty motors and/or motors with roller bearings 121 Motor is rated for F rise 1000:1 Constant Torque Range, and F Rise 4:1 Constant Torque Range 122 Motor rated for only F rise 4:1 Constant Torque Range Note - All motors highlighted in ROSE are cast iron frames Version Version Note- Controlled by Passport See Version Notes for Revision Changes Bulletin CM100 Component Class - Inverter Duty CM200 Architecture Class - Vector Duty CM300 Sine Wave Class Enclosure DG DPG - Drip-Proof Guarded FV DPG-FV - Drip-Proof Guarded Force Ventilated DP ODP - Open Drip-Proof AO TEAO - Totally Enclosed Air Over BC TEBC - Totally Enclosed Blower Cooled FC TEFC - Totally Enclosed Fan Cooled NV TENV - Totally Enclosed Non Ventilated AA TEDC A/A - Totally Enclosed Dual Cooled Air to Air AW TEDC A/W - Totally Enclosed Dual Cooled Air to Water Bulletin Enclosure Horsepower Base Speed Voltage Effi ciency CT or VT Required Mounting Final Descriptor Version Allen-Bradley Control Matched Motors Catalog String Decoder Horsepower HP as listed 025 25 Horsepower Note “F” is used for a decimal point 030 30 Horsepower F17 0.17 Horsepower 040 40 Horsepower F25 0.25 Horsepower 050 50 Horsepower F33 0.33 Horsepower 060 60 Horsepower 0F5 0.5 Horsepower 075 75 Horsepower F75 0.75 Horsepower 100 100 Horsepower 001 1 Horsepower 125 125 Horsepower 1F5 1.5 Horsepower 150 150 Horsepower 002 2 Horsepower 200 200 Horsepower 003 3 Horsepower 250 250 Horsepower 005 5 Horsepower 300 300 Horsepower 7F5 7.5 Horsepower 350 350 Horsepower 010 10 Horsepower 400 400 Horsepower 015 15 Horsepower 450 450 Horsepower 020 20 Horsepower 500 500 Horsepower 1K0 1000 Horsepower Base Speed As noted - fi rst two digits of base speed 05 500 RPM 12 1200 RPM 06 650 RPM 15 1500 RPM 07 720 RPM 17 1750 RPM 08 850 RPM 18 1800 RPM 09 900 RPM 25 2500 RPM 10 1000 RPM 35 3550 RPM 11 1150 RPM 36 3600 RPM Voltage F 230 Volt, 3 Phase, 60 Hz L 180 V Arm, 100/200 V Field, Str Winding D 380 Volt, 3 Phase, 50 Hz M 240 V Arm, 150 V Field, Str Winding E 400 Volt, 3 Phase, 50 Hz N 240 V Arm, 240 V Field, Str Winding B 460 Volt, 3 Phase, 60 Hz Q 500 V Arm, 300 V Field, Str Winding C 575 Volt, 3 Phase, 60 Hz P 500 V Arm, 150/300 V Field, Stab Winding R 2300 Volt, 3 Phase, 60 Hz T 240 V Arm, 150 V Field, Stab Winding S 4160 Volt, 3 Phase, 60 Hz U 240 V Arm, 240 V Field, Stab Winding H 200/208 Volt, 3 Phase, 60 Hz V 500 V Arm, 300 V Field, Stab Winding G 208-230/460 Volt, 3 Phase, 60 Hz W 90 V Arm, PM Field A 230/460 Volt, 3 Phase, 60 Hz J 180 V Arm, PM Field K 90 V Arm, 50/100 V Field Effi ciency E Energy Effi cient - Meets EPAct Requirements S Standard Effi cient N NEMA Premium P Premium Effi cient X Not Applicable CT or VT required H CT 10:1 Constant Torque 10:1 Speed Range Z CT 1000:1 Constant Torque 1000:1 Speed Range (0 to Base Speed) J CT 2:1 Constant Torque 2:1 Speed Range J CT 2:1 (10) Constant Torque 2:1 Speed Range (capable of 10:1 CT with fan change) M CT 20:1 Constant Torque 20:1 Speed Range K CT 4:1 Constant Torque 4:1 Speed Range K CT 4:1 (10) Constant Torque 4:1 Speed Range (capable of 10:1 CT with fan change) X na Not for use on inverter power V VT 10:1 Variable Torque 10:1 Speed Range V VT 10:1 (2) Variable Torque 10:1 Speed Range (capable of 2:1 CT with fan change) Mounting C C-Face Foot Mounted F C-Face Footless H Foot Mounted U Foot Mounted, Roller Bearing Final Discriptor 4 140 Frame Motor 5 56 Frame Motor 8 180 Frame Motor I Cast iron Frame N Non-cast iron frame S TS shaft length T Nema T shaft length This tool should ONLY be used to DECODE existing catalog strings. It CANNOT be used to create a new part number. Allen Bradley Control Matched Motors Table of Contents General Information CM 100CM 200CM 300Footnotes Table of Contents GENERAL INFORMATION Efficiency Abbreviations . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Agency Approvals/Certifications/Approvals . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Cancellation Charges . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Freight Policy . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Warranty Policy . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Motor Selection and Application . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Conduit Box Location Chart . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Evaluation of Motor Efficiency . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Rush/Breakdown Order Procedures . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Sales Order Change Charges . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Rockwell Automation Motor Service Centers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Documentation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Return Policies . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . RAISE Software File Information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . COMPONENT CLASS For use on inverter for variable torque and constant torque (less than 10:1) applications, no encoder capability, 3 NC thermostats included INVERTER DUTY GENERAL PURPOSE SERIES CM101 – Enclosed Energy Efficient Rolled Steel. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Most Economical Inverter Capable, Totally Enclosed Motor 10:1 VT and 2:1 CT Capability CM102 – Enclosed Energy Efficient Cast Iron. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Most Economical Inverter Capable, Cast Iron Totally Enclosed Motor 10:1 VT and 2:1 CT Capability CM103 – Totally Enclosed Energy Efficient, Premium Efficient, and NEMA Premium . . . . . . . . . . . . Designed for General Purpose Applications 10:1 VT and varying CT Capability CM106 – Open Energy Efficient Rolled Steel. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Most Economical Inverter Capable, Open Motor Available, 10:1 VT and 2:1 CT Capability CM107 – Open Energy Efficient, Premium Efficient, NEMA Premium . . . . . . . . . . . . . . . . . . . . . . . . . General Purpose Open motors 10:1 VT and 2:1 CT Capability Table of Contents - Allen Bradley Control Matched Motors General Information CM 100CM 200CM 300Footnotes 1 1 3 3 4 5 9 10 12 12 12 13 13 13 14 18 22 32 35 HARSH DUTY HARSH ENVIRONMENT SERIES CM111 – Severe Duty . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Designed with features for long life in severe environments such as chemical plants, petroleum refineries, and paper mills 10:1 VT and varying CT Capability CM112 – IEEE 841 XL . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Exceeds IEEE841 mechanical requirements Built extra tough for durability in harsh environments 10:1 VT and varying CT Capability CM113 – Aggregate Duty . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Designed with high starting torque and break down torque for heavily loaded conveyor and crusher applications 10:1 VT and varying CT Capability CM115 – Wash Down Duty . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Designed for service in wash down applications subject to sanitary codes, IP55 10:1 VT and varying CT Capability CM118 – Stainless Steel. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Designed for use in food or chemical applications where painted motors are undesirable, IP55 10:1 VT and varying CT Capability CM100 KITS. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ARCHITECTURE CLASS For use on inverter only for high performance applications, encoder capable, 3 NC thermostats included INDUSTRIAL ENVIRONMENT SERIES CM201 – Vector Duty Enclosed Small AC Motors . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1000:1 CT Capable, TENV and TEFC Enclosures CM202 – Vector Duty Totally Enclosed Cast Iron NEMA AC Motors . . . . . . . . . . . . . . . . . . . . . . . . . . . 1000:1 Capable, TEFC and TENV Enclosures CM202 KITS. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . CM203 – Vector Duty Laminated AC Motors . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1000:1 Capable; DPFV, TEBC, TENV, and TEFC Enclosures CM203 KITS. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . CM205 – DC Motors . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Designed with laminated square frame for more performance in smaller frames DPG-FV and TEFC enclosures CM205 KITS. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . CM206 – Small DC Motors . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Designed for reliability and long life in variable speed applications TEFC and TENV Enclosures Table of Contents - Allen Bradley Control Matched Motors General Information CM 100 CM 200 CM 300 Footnotes 39 49 54 57 62 65 73 76 82 83 106 111 120 123 SINE WAVE CLASS For use on sine wave power for fixed speed applications such as conveyors, blowers, pumps or fans GENERAL PURPOSE SERIES CM301 – Enclosed Energy Efficient Rolled Steel. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Most Economical Totally Enclosed Motor CM302 – Enclosed Energy Efficient Cast Iron. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Most Economical Cast Iron Totally Enclosed Motor CM303 – Totally Enclosed Energy Efficient, Premium Efficient, and NEMA Premium . . . . . . . . . . . . Designed for General Purpose Applications CM306 – Open Energy Efficient Rolled Steel . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Most Economical Open Motor Available CM307 – Open Energy Efficient, Premium Efficient, NEMA Premium . . . . . . . . . . . . . . . . . . . . . . . . . General Purpose Open motors HARSH ENVIRONMENT SERIES CM311 – Severe Duty. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Designed with features for long life in severe environments such as chemical plants, petroleum refineries, and paper mills CM312 – IEEE 841 XL . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Exceeds IEEE841 mechanical requirements Built extra tough for durability in harsh environments CM313 – Aggregate Duty. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Designed with high starting torque and break down torque for heavily loaded conveyor and crusher applications CM315 – Wash Down Duty. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Designed for service in wash down applications subject to sanitary codes, IP55 CM318 – Stainless Steel . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Designed for use in food or chemical applications where painted motors are undesirable, IP55 Table of Contents - Allen Bradley Control Matched Motors General Information CM 100CM 200CM 300Footnotes 128 132 136 146 149 153 163 168 171 176 Allen Bradley Control Matched Motors General Information General Information CM 100CM 200CM 300Footnotes For additional product information refer to Proposal Builder. General Information Efficiency Abbreviations Agency Approvals/Certifications/Definitions NEMA PREMIUM/CEE The Consortium for Energy Efficiency (CEE) a non-profit, public-benefit corporation helps find ways that consumers, businesses and manufacturers can save energy. CEE members include electric and gas utilities, public interest groups, research and development organizations, state energy offices and regional programs. Both the U.S. Environmental Protection Agency (EPA) and the Department of Energy (DOE) are major partners. CEE coordinates market research, facilitates the exchange of information and provides interface with national manufacturers, such as Rockwell Automation by establishing specifications for energy-efficient products and services. The tables below can be used to determine which Allen-Bradley motors meet or exceed the NEMA Premium/CEE specifications. CSA Canadian Standards Association is the clearinghouse and coordinating body for standards activity on a national level. Products covered by CSA are either “Certified” or “Labeled” depending on the standards involved. CSA NRTL/C MARK Hazardous Location Report: LR 6771, LR 19467, LR 46877, LR 53258, LR60344 Ordinary Location Report: LR 7861, LR 40567, LR52580, LR 62409 This monogram indicates the product complies with both USA (UL) and CSA standards. This marking should be accepted by all localities in the USA and Canada. Division II atmosphere is normally not explosive, but under unusual conditions can become explosive. Rockwell Automation has a defined Division II product line and received CSA certification on the following: 180T - 449T AC 1080T - 9600 AC 169AT - 1610AT DC 7MG - 80MG The standard Division II enclosure is TEFC with Severe Duty features. However, other enclosures are available. SE=Standard Efficient EE=Energy Efficient (EPAct compliant where applicable) PE=Premium Efficient NP=NEMA Premium Efficient NEMA Premium/ CEE Efficiency Table NEMA Premium/ CEE Efficiency Table HP RPM Efficiency HP RPM Efficiency 3 3600 86.5 40 3600 92.4 1800 89.5 1800 94.1 1200 89.5 1200 94.1 5 3600 88.5 50 3600 93.0 1800 89.5 1800 94.5 1200 89.5 1200 94.1 7.5 3600 90.2 60 3600 93.6 1800 91.7 1800 95.0 1200 91.0 1200 94.5 10 3600 90.2 75 3600 93.6 1800 91.7 1800 95.4 1200 91.0 1200 94.5 15 3600 91.0 100 3600 94.1 1800 92.4 1800 95.4 1200 91.7 1200 95.0 20 3600 91.0 125 3600 95.0 1800 93.0 1800 95.4 1200 91.7 1200 95.0 25 3600 91.7 150 3600 95.0 1800 93.6 1800 95.8 1200 93.0 1200 95.8 30 3600 91.7 200 3600 95.4 1800 93.6 1800 96.2 1200 93.0 1200 95.8 General Information - Allen Bradley Control Matched Motors 1 General Information CM 100CM 200CM 300Footnotes For additional product information refer to Proposal Builder. C390 C390 is the Canadian efficiency equivalent of EPAct. File number: EEV79350 Requires at least an Energy Efficient electrical design motor to meet C390. CENELEC The European Committee for Electrotechnical Standardization defines compliance standards for CE mark required on motors shipping to Europe. This mark signifies the motor complies with all applicable European Directives. REL-4496-001 (Kings Mountain DC Motors) REL-0296-001 (AC Induction Motors) REL-4596-001 (Gainesville DC Motors) For hazardous locations in Europe or for ATEX certification or “EX” mark or flame proof enclosure, contact your local Rockwell Automation sales representative. Compliance Certification (CC049A and CC019A) Numbers This symbol and certification numbers indicate that certain Allen-Bradley catalog numbers meet or exceed the energy efficiency requirements contained in title 10 of the Code of Federal Regulations Part 431 (10 CFR Part 431), Energy Conservation Program for Certain Commercial and Indus- trial Equipment and Part C of the Energy Policy and Conservation Act, 42 U.S.C. 6311 et seq. Allen-Bradley motors covered by the certification (Energy Efficient "EE", Premium Efficient "PE", and NEMA Premium “NP”) are footnoted in the catalog with CC049A and CC019A com- pliance certification numbers. Basic guidelines: • 1-200 hp (.75-150 kw) • Open, Enclosed, or Explosion Proof • 2, 4, or 6 pole (single speed) • Continuous duty • Squirrel cage rotor (NEMA) or cage rotor (IEC) • Foot mounted, including foot mounted with flanges or detachable feet • NEMA T frame or IEC metric equivalent • NEMA Design A or B, IEC Design N • 60 hz • 230 or 460 volt or both These are general guidelines and not intended to be used as the final determination of compliance. For specific questions pertaining to this compliance, please contact your Rockwell Automation sales representative. IEEE Institute of Electrical and Electronic Engineers is a Technical Organization that publishes various recommended practices, which have been adopted as Industry Standards. Recommended practices do not require approval action or special testing. Rockwell Automation may furnish specialized equipment in accordance with this specification. ISO 9000 Certification Rockwell Automation’s continued commitment to quality and worldwide acceptance is evidenced by the Madison, IN, Athens, GA, Gainesville, GA, Kings Mountain, NC and Stratford, Ontario motor plants’ certification to the ISO 9001 international quality standard. Many of Rockwell Automation’s other locations are also ISO 9000 certified. Please contact your local Rockwell Automation representative for additional information on the ISO 9000 standards and Rockwell Automation compliance. NEC National Electrical Code is an ASA Standard “NFPA-70” sponsored by the National Fire Protection Association for the purpose of safeguarding persons and buildings from electrical hazard arising from the use of electricity for light, heat, power, and other purposes. NEMA National Electrical Manufacturers Association. Standards are voluntary standards that represent general practices in the industry. They define a product, process or procedure with reference to nomenclature, composition, construction, dimensions, tolerances, operating characteristics, performance, quality, rating and testing. Specifically, they cover such matters as frame sizes, torque classifications, and basis of rating. NRCAN Natural Resources Canada For Canadian customers, NRCAN regulations require registration and energy efficiency reporting of certain 1-200HP and 0.75-150KW rated motors. The following website address will lead to the NRCAN website and Rockwell Automation forms for both NEMA and IEC motors as well as UMI codes. The address is www.reliance.com/mtr/orgreg.htm. Just click on NRCAN from the column on the left side of this website page. General Information - Allen Bradley Control Matched Motors 2 General Information CM 100 CM 200 CM 300 Footnotes For additional product information refer to Proposal Builder. UL & UR Underwriters’ Laboratories, Inc. is chartered as a non- profit organization to establish, maintain, and operate laboratories for the examination and testing of devices, systems, and materials. The UL presently publishes more than 250 Standards for Safety for materials, devices, constructions and methods. UL also undertakes numerous research projects in areas of safety. /Description Description Division I atmosphere is considered potentially explosive under normal conditions. For hazardous locations in Europe or for ATEX certification or “EX” mark or flame proof enclosure, contact your local Rockwell Automation sales representative. Temperature Codes (“T” Codes) NEC requires explosion-proof motors to indicate the maximum operating surface temperature. A “T” Code is used as the temperature identification value and it is taken from the National Electric Code. The “T” Code is based on the minimum ignition temperature of the substances to be found in the hazardous location. (Ignition temperature is when substance will start to burn or explode) The code, when marked on a motor nameplate, represents the highest temperature that could be obtained on the motor surface under any normal or abnormal operating conditions including locked rotor, single phasing or overloading, and is chosen to be below the ignition temperature of the substance in the hazardous area. The “T” Code designations apply to motors and other types of electrical equipment subject to hazardous location classification. For further information, consult the Motor Technical Reference (MTR) on the Web at http:// www.reliance.com/mtr. Cancellation Charges Non-Stock Motors A minimum charge of $100 will apply to any order cancellation. Cancellation charges for orders received and entered on the manufacturing facility will be determined based on cost incurred. Completion of order includes consideration of the following: • order edit and acknowledgment • capacity allocation • engineering and specification • material commitment (raw, finished, and purchased ) Completion progress to be determined by producing plant customer service. Stock Motors No cancellation charges are incurred if order is cancelled prior to shipment. Freight Policy For complete information, refer to appropriate discount sheet. Frames/Description Environment File Number 48 - 140T Hazardous E6881 182T - 9500 AC Hazardous E10822 180AT - 500AT DC Hazardous E10822 Thermal Protectors Recognized E22031 Motor Components Recognized E54825 Insulation Materials Recognized E39972 Conduit Boxes Hazardous E30225, E40711 Hermetic Recognized SA5484 General Information - Allen Bradley Control Matched Motors 3 General Information CM 100CM 200CM 300Footnotes [...]... to low horsepower ratings or short-time rated motors Totally Enclosed Fan-Cooled - Exterior surface cooled by external fan on motor shaft Motor cooling is dependent on motor speed Totally Enclosed Air-Over - Exterior surface cooled by a ventilating means external to the motor Customer must provide sufficient air flow to cool motor Additional protection for motors used in extremely dirty or humid conditions... = $/KWH = PEEFF = STDEFF = Motor full load horsepower Number of hours per year the motor is in operation Cost of electricity in dollars per kilowatt hour PE motor efficiency Standard motor efficiency If actual motor efficiency is unknown, a Rockwell Automation sales engineer can help you estimate standard motor efficiencies First, calculate the kilowatts saved by using the PE motor: Kilowatts Saved = HP... Matched Motors Documentation The following table indicates motor documentation and reports that can be ordered with your Allen-Bradley motor These catalog numbers must be ordered at the same time the motors are ordered Catalog Number Description List Price Discount Schedule Typical Lead Time MOTOR CERTIFIED DRAWINGS $50 16 4-6 weeks 1301-MTRMFG TYPICAL DIMENSION DRAWING $0 16 Varies 1301-MTRACAD MOTOR. .. DIMENSION DRAWINGS in AUTOCAD 14 FORMAT on DISK $150 16 After Motor Ships 1301-MTRAPP MOTOR APPROVAL DRAWINGS $0 16 4-6 weeks 1301-MTRSTDPD MOTOR STD TABULATED PERFORMANCE DATA $60 16 After Motor Ships 1301-MTRPLIST MOTOR SPARE PARTS LIST $15 16 After Motor Ships RAISE Software - Electronic Product Information Technical Information for specific motors is available prior to order entry through use of Proposal... Dust Ignition Proof - A Dust Ignition Proof motor is a totally enclosed machine designed to operate safely in a flammable dust environment The motor enclosure prevents the admittance of dust inside the motor Also the motor is designed to operate cool enough so as not to ignite any dust which might accumulate on the external surface of the motor Should the motor become blanketed with dust and reduce... Proposal Builder 6 Phase - Motors are designed for either single-phase or three-phase operation as indicated on the price pages Single-phase motors may be operated on one-phase of a three-phase power supply with the rated voltage Operation of a three-phase motor on a single-phase supply will result in motor damage Voltage Single Phase Motors - standard voltages are 115/230 Three Phase Motors - standard voltage... Matched Motors 9 General Information - Allen Bradley Control Matched Motors General Information Evaluating Motor Efficiency Analyze, Compare and Calculate Your Energy Savings The graphs below show how the Allen-Bradley PE motor efficiency and watts loss curves compare to standard industrial averages The table below shows the results of these comparisons in terms of annual energy savings CM 100 Motor Efficiency... a C-face as indicated on the price pages The motor must be mounted on a rigid mounting surface for satisfactory operation Installation - Motor must be in areas or in supplementary enclosures which do not seriously interfere with the ventilation of the motor Frequency - Motors are designed for operation on 50 or 60 Hz as specified on the price pages Many motors designed for operation on 60 Hz power may... Most motors are Design B with a few Design A, C & D For motors having different characteristics than listed, contact Rockwell Automation Synchronous Speed (rpm) = 120 x Power Supply Frequency (HZ) Number of Poles The number of poles is a function of motor design Standard 60 Hz motors are available with synchronous speeds of 3600, 1800, 1200 or 900 rpm The actual operating speed of an AC induction motor. .. motors (SE) 12 months 24 months Energy Efficient motors (EE) 12 months 24 months Premium Efficient motors (PE) 24 months 36 months NEMA Premium Efficient motors (NP) Footnotes From Installation Date 24 months 36 months IEEE-841 motors 48 months 60 months DC Motors – CM205, CM206 12 months 24 months Vector Duty AC motors – CM201, CM202, CM203 24 months 36 months *Whichever warranty period occurs first For additional . Ships 1301-MTRAPP MOTOR APPROVAL DRAWINGS $0 16 4-6 weeks 1301-MTRSTDPD MOTOR STD TABULATED PERFORMANCE DATA $60 16 After Motor Ships 1301-MTRPLIST MOTOR SPARE PARTS LIST $15 16 After Motor Ships General. Non-NAFTA motors 104 Not available for 841 XL motors 105 Not available on SABRE and CALIBRE product lines 106 Finned aluminum frame construction 107 Not available on belted duty motors and/or motors. mark signifies the motor complies with all applicable European Directives. REL-4496-001 (Kings Mountain DC Motors) REL-0296-001 (AC Induction Motors) REL-4596-001 (Gainesville DC Motors) For hazardous