Tài liệu về mạng AS i của hãng siemens

86 623 1
Tài liệu về mạng  AS i của hãng siemens

Đang tải... (xem toàn văn)

Tài liệu hạn chế xem trước, để xem đầy đủ mời bạn chọn Tải xuống

Thông tin tài liệu

01415_Kompaktstarter 12.08.1998 10:45 Uhr Seite AS-Interface Kompaktstarter Compact Starter Handbuch Manual Bestell-Nr./Order No.: 3RK1702-2GB10-2AA0 Important Information, Contents System Description Installation Wiring Commissioning Hand-held Controller Technical Data SIGUARD Safety Integrated AS-Interface Compact Starter Manual Appendix Selection Help A Order Numbers B Index Order No.: 3RK1702-2GB10-2AA0 Safety guidelines This manual contains notices which you should observe to ensure your own personal safety, as well as to protect the product and connected equipment These notices are highlighted in the manual by a warning triangle and are marked as follows according to the level of danger: Safety note Contains important information for the acceptance test and the safety-related use of the product Danger Indicates that death, severe personal injury or substantial property damage will result if proper precautions are not taken Warning Indicates that death, severe personal injury or substantial property damage can result if proper precautions are not taken Warning Indicates that minor personal injury or property damage can result if proper precautions are not taken Caution indicates that property damage can result if proper precautions are not taken Important Draws your attention to particularly important information on the product, handling the product, or to a particular part of the documentation Qualified personnel Only qualified personnel should be allowed to install and work on this equipment Qualified persons are defined as persons who are authorized to commission, to ground, and to tag circuits, equipment, and systems in accordance with established safety practices and standards Correct usage Note the following: Warning This device and its components may only be used for the applications described in the catalogue or the technical descriptions, and only in connection with devices or components from other manufacturers which have been approved or recommended by Siemens This product can only function correctly and safely if it is transported, stored, set up, and installed correctly, and operated and maintained as recommended Brands SIMATIC®, SIMATIC HMI® and SIMATIC NET® are brands of SIEMENS AG Some other designations used in these documents are also brands; the owner's rights may be violated if they are used by third parties for their own purposes Copyright Siemens AG 2003 All rights reserved Disclaimer of liability The reproduction, transmission or use of this document or its contents is not permitted without express written authority Offenders will be liable for damages All rights, including rights created by patent grant or registration of a utility model or design, are reserved We have checked this manual to ensure that its contents are correct and applicable in relation to the hardware and software it describes Despite all our endeavors, however, discrepancies cannot be wholly excluded and so we cannot guarantee complete correctness and applicability However, the data in this manual are reviewed regularly and any necessary corrections included in subsequent editions Suggestions for improvement are welcomed Technical Assistance: Telephone: Fax: E-mail: Internet: SIEMENS AG Industry Sector Postfach 48 48 90026 NÜRNBERG GERMANY Siemens Aktiengesellschaft +49 (0) 911-895-5900 (8°° - 17°° CET) +49 (0) 911-895-5907 technical-assistance@siemens.com www.siemens.de/lowvoltage/technical-assistance SIEMENS AG Technical Assistance Würzburger Str 121 D-90766 Fürth Siemens AG 2003 Technical data subject to change without notice System Description 1-1 1.1 1.2 1.3 1.4 What is the Actuator-Sensor Interface (AS-i)? What are the AS-i Compact Starters DS2DI and RS2DI? What are the AS-i Compact Starters EDS2DI and ERS2DI? Connection Example Installation 2-1 2.1 2.2 Installing the Compact Starter Dimensions 2-2 2-3 Wiring 3-1 3.1 3.2 3.2.1 3.2.2 3.2.3 3.3 3.3.1 3.3.2 3.3.3 3.4 3.4.1 3.4.2 3.4.3 3.5 Rules for Wiring Making up Connecting Cables Wiring the Power Connectors Electrical Design Additional Inputs IN1 and IN2 Commissioning 4.1 4.1.1 4.1.2 4.1.3 4.1.4 4.2 4.2.1 4.2.2 4.2.3 4.2.4 Compact Starters DS2DI and RS2DI Compact Starters without a Braking Contact Making up Connecting Cables Wiring the Power Connectors Electrical Design Compact Starters with a 24 V DC Braking Contact Making up Connecting Cables Wiring the Power Connectors Electrical Design Compact Starters with a 400 V AC resp 500 V DC Braking Contact 3-2 3-4 3-4 3-5 3-7 3-8 3-8 3-9 3-11 3-12 3-12 3-13 3-15 3-17 4-1 Addressing Before Commissioning Operation Diagnostics Compact Starters EDS2DI and Addressing Before Commissioning Operation Diagnostics 5.1 5.2 5.3 5.4 Functions and View Operation LEDs Buttons ERS2DI Hand-held Controller GWA 4NEB 640 0909-32 DS02 1-2 1-3 1-4 1-5 4-2 4-2 4-3 4-4 4-5 4-8 4-8 4-9 4-11 4-13 5-1 5-2 5-3 5-4 5-5 i English Deutsch Contents Contents Technical Data 6-1 6.1 6.2 6.3 6.4 6.5 6.6 6.7 6.8 6.9 Compact Starter Data Voltages and Currents Braking Current Circuit Additional Inputs IN1 and IN2 Data pertaining to the Compact Starters DS2DI and RS2DI Data pertaining to the Compact Starters EDS2DI and ERS2DI Shipping and Storage Conditions Mechanical and Climatic Environment Conditions Electromagnetic Compatibility SIGUARD Safety Integrated 7.1 7.1.1 7.1.2 7.1.3 7.1.4 Suggested Circuits Safety Category (EN 954-1) Safety Category (EN 954-1) Safety Category (EN 954-1) Safety Category (EN 954-1) A Selection Help A-1 A.1 A.2 Application Examples Motor List A-2 A-3 B Order Numbers B-1 B.1 B.2 B.3 Electromechanical Compact Starters DS2DI and RS2DI Electronic Compact Starters EDS2DI and ERS2DI Accessories B-2 B-4 B-5 6-2 6-3 6-4 6-4 6-5 6-6 6-7 6-8 6-9 7-1 7-2 7-2 7-2 7-3 7-3 Index ii GWA 4NEB 640 0909-32 DS02 Deutsch 1 English System Description Section Page 1.1 What is the Actuator-Sensor Interface (AS-i)? 1-2 1.2 What are the AS-i Compact Starters DS2DI and RS2DI? 1-3 1.3 What are the AS-i Compact Starters EDS2DI and ERS2DI? 1-4 1.4 GWA 4NEB 640 0909-32 DS02 Subject Connection Example 1-5 1-1 System Description 1.1 What is the Actuator-Sensor Interface (AS-i)? Deutsch What is AS-i? When a system is installed, the input/output modules are normally installed centrally in the programmable logic controller If inputs and outputs are made at long distances from the programmable logic controller, there may be long runs of cabling which are not immediately comprehensible, and electromagnetic interference may impair reliability English In such systems, we recommend you to use the AS-i. The AS-i is an open bus system, that means: • The controller CPU with the AS-i master is located centrally • The I/O (input/output) system operates locally in a distributed fashion What does AS-i consist of? The actuator-sensor interface consists of active and passive nodes, socalled master and slaves Up to 31 slaves in any network structure can be connected to a master AS-i slaves and AS-i master are interconnected by a 2-wire line used to transmit both data and power to the slave electronics Modules in IP 65/67 BERO proximity switch ET 200X Distributed I/O Device AS-Interface Compact starter X1 X2 X3 X1 X2 X3 Energy bus SIGNUM command devices AS-i Master and AS-i Slave AS-i master is the link between controller and the distributed I/O system The AS- master exchanges data with the AS-i slave and monitors the bus The I/O devices are connected as AS-i slaves DP slaves process data locally from the sensors and signal control elements in such a manner that they can be transferred over the AS-i bus 1-2 GWA 4NEB 640 0909-32 DS02 System Description AS-i compact starters DS2DI and RS2DI are electromechanical motor starters • They are suitable for switching and protecting any three-phase loads up to 5.5 kW with 400 V AC • They are available as either direct-on-line starters (DS2DI) or reversing starters (RS2DI) with adjustment ranges from 0.14 to 0.2 A and to 12 A respectively • They can be equipped with a 24 V DC, max A, or 500 V DC, max 0.2 A, braking contact as an option AS-i compact starters DS2DI and RS2DI have the following connections: • power connections for feeding and looping through the load supply voltage and for connecting the actual load, • an M12 socket (double wired) for connecting sensors, • a connection for a hand-held controller, • an addressing jack for setting the slave address The diagram below shows the components of an electromechanical  AS-i compact starter View Transparent cover, open SIEMENS Addressing jack LEDs – Communication – Auxiliary power – Function status AS-i AUX PWR STATE Circuit-breaker – Scale for current setting – Toggle switch – Test opening SUB-D socket (for hand-held controller only!) Power socket X2 for connecting – load – brake Power connector X1 for feeding – load supply voltage – 24 V DC braking voltage  (on versions with a  braking contact) Interlock GWA 4NEB 640 0909-32 DS02 Power socket X3 for looping through – load supply voltage – 24 V DC braking voltage  (on versions with a  braking contact) M12 socket X4 for connecting sensors 1-3 English Characteristics Deutsch 1.2 What are the AS-i Compact Starters DS2DI and RS2DI? System Description 1.3 What are the AS-i Compact Starters EDS2DI and ERS2DI? Deutsch Characteristics AS-i compact starters EDS2DI and ERS2DI are electronic motor starters English • They are suitable for switching and protecting any three-phase loads up to 2.2 kW with 400 V AC • They are available as either direct-on-line starters (EDS2DI) or reversing starters (ERS2DI) with adjustment ranges from 0.6 to 2.18 A and 2.0 to 5.95 A respectively • They can be equipped with a 24 V DC, max A, or 400 V AC, max 0,5 A, or 500 V DC, max 0.2 A, braking contact as an option AS-i compact starters EDS2DI and ERS2DI have the following connections: • power connections for feeding and looping through the load supply voltage and for connecting the actual load, • an M12 socket (double wired) for connecting sensors, • a connection for a hand-held controller, • an addressing jack for setting the slave address View The diagram below shows the components of an electronic AS-i compact starter Transparent cover, open LEDs SIEMENS Addressing jack LEDs – Communication – Auxiliary power – Function status – – – – READY RUN FAULT OVERLOAD AS-i AUX PWR STATE Rotary encoder switches and for setting the current TEST/RESET button SUB-D socket (for hand-held controller only!) Power connector X1 for feeding – load supply voltage – 24 V DC braking voltage  (on versions with a  braking contact) Interlock 1-4 Rotary encoder switch tripping REMOTE/LOCAL Power socket X2 for connecting – load – brake Power socket X3 for looping through – load supply voltage – 24 V DC braking voltage  (on versions with a  braking contact) M12 socket X4 for connecting sensors GWA 4NEB 640 0909-32 DS02 Selection Help A.1 Application Examples Deutsch The table below contains various applications together with the type and number of AS-i compact starters that you need for each application You can actuate both pole-changing motors and motors with separate windings Applications English Without brake Direct-on-line starter One dir of rotation One speed 1) 1) One dir of rotation One speed Two dir of rotation One speed One dir of rotation Two speeds Two dir of rotation Two speeds Notes Reversing starter with braking contact Two dir of rotation Two speeds With brake Direct-on-line starter with braking contact Two dir of rotation One speed One dir of rotation Two speeds Reversing starter 1 2) 2) 2) 3) 2) 3) 1) The two speeds must be mutually interlocked in the user program with the feedback contactor of the other starter 2) see 1), but in addition the output brake of one starter must remain set during switchover and activation of the other starter 3) This version is suitable if you want to loop the 24 V DC braking voltage through to the next drive The 24 V DC braking voltage cannot be looped through via a compact controller without braking contact A-2 GWA 4NEB 640 0909-32 DS02 Selection Help The following tables contain the operating values of squirrel-cage motors of basic design Source: Siemens Three-Phase AC Low-Voltage Motors Catalog Speed 3000 rpm two-pole Rated power kW Rated speed rpm Efficiency % Power factor cos  Rated current A 0.83 0.52 25 2725 64 0.82 0.69 2750 67 0.80 1.00 2790 71 0.81 1.38 2850 74 0.83 1.76 1.1 2835 76 0.84 2.45 1.5 2860 78 0.82 3.40 2.2 2850 80 0.85 4.65 2895 83 0.86 6.10 2895 85 0.87 7.80 5.5 2910 84 0.84 11.30 0.18 1315 59 0.76 0.58 0.25 1325 61 0.73 0.81 0.35 1375 66 0.77 1.05 0.55 1395 71 0.79 1.42 0.75 1395 74 0.79 1.86 1.1 1410 74 0.81 2.65 1.5 1410 74 0.81 3.60 2.2 1420 78 0.78 5.20 1430 80 0.80 6.80 1435 83 0.79 9.00 5.5 GWA 4NEB 640 0909-32 DS02 60 0.75 50 Hz 400 V 2680 0.55 Speed 1500 rpm four-pole 0.18 0.37 50 Hz 400 V 1450 86 0.81 English Motor List Deutsch A.2 Motor List 11.40 A-3 Selection Help Deutsch Speed 1000 rpm six-pole Rated power kW Rated speed rpm Efficiency % Power factor cos  Rated current A 0.69 0.25 825 59 0.74 0.83 910 62 0.72 1.19 900 65 0.73 1.67 895 67 0.77 2.10 900 71 0.75 3.00 1.5 930 72 0.75 4.00 2.2 945 76 0.72 5.80 945 70 0.75 7.30 940 79 0.75 9.70 0.12 655 51 0.59 0.58 0.18 675 51 0.66 0.78 0.25 670 52 0.62 1.12 0.35 655 61 0.76 1.16 0.55 650 65 0.76 1.62 0.75 665 65 0.77 2.15 1.1 675 72 0.76 2.90 1.5 710 72 0.71 4.25 2.2 695 76 0.71 5.90 700 79 0.69 7.90 English 0.71 1.1 A-4 53 0.75 50 Hz 400 V 830 0.55 Speed 750 rpm eight-pole 0.18 0.35 50 Hz 400 V 715 77 0.72 10.40 GWA 4NEB 640 0909-32 DS02 Deutsch B English Order Numbers Section Page B.1 Electromechanical Compact Starters DS2DI and RS2DI B-2 B.2 Electronic Compact Starters EDS2DI and ERS2DI B-4 B.3 GWA 4NEB 640 0909-32 DS02 Subject Accessories B-5 B-1 Order Numbers B.1 Electromechanical Compact Starters DS2DI and RS2DI Deutsch Direct-on-line Starters DS2DI Adjustment range* Order number A Order number-extension English Basic version Versions with braking contact 24 V DC 500 V DC 0.14 - 0.20 3RK1 322-0BS02- 0AA0 0AA1 0AA4 0.18 - 0.25 3RK1 322-0CS02- 0AA0 0AA1 0AA4 0.22 - 0.32 3RK1 322-0DS02- 0AA0 0AA1 0AA4 0.28 - 0.40 3RK1 322-0ES02- 0AA0 0AA1 0AA4 0.35 - 0.50 3RK1 322-0FS02- 0AA0 0AA1 0AA4 0.45 - 0.63 3RK1 322-0GS02- 0AA0 0AA1 0AA4 0.55 - 0.80 3RK1 322-0HS02- 0AA0 0AA1 0AA4 0.70 - 1.00 3RK1 322-0JS02- 0AA0 0AA1 0AA4 0.90 - 1.25 3RK1 322-0KS02- 0AA0 0AA1 0AA4 1.10 - 1.60 3RK1 322-1AS02- 0AA0 0AA1 0AA4 1.40 - 2.00 3RK1 322-1BS02- 0AA0 0AA1 0AA4 1.80 - 2.50 3RK1 322-1CS02- 0AA0 0AA1 0AA4 2.20 - 3.20 3RK1 322-1DS02- 0AA0 0AA1 0AA4 2.80 - 4.00 3RK1 322-1ES02- 0AA0 0AA1 0AA4 3.50 - 5,00 3RK1 322-1FS02- 0AA0 0AA1 0AA4 4.50 - 6.30 3RK1 322-1GS02- 0AA0 0AA1 0AA4 5.50 - 8.00 3RK1 322-1HS02- 0AA0 0AA1 0AA4 7.00 - 10.0 3RK1 322-1JS02- 0AA0 0AA1 0AA4 9.00 - 12.0 3RK1 322-1KS02- 0AA0 0AA1 0AA4  * For assignment to performance of 400 V AC squirrel-cage motors see Appendix A.2 B-2 GWA 4NEB 640 0909-32 DS02 Order Numbers Adjustment range* Order number A Deutsch Reversing Starters RS2DI Order number-extension Basic version Versions with braking contact 24 V DC 500 V DC 3RK1 322-0BS02- 1AA0 1AA1 1AA4 0.18 - 0.25 3RK1 322-0CS02- 1AA0 1AA1 1AA4 0.22 - 0.32 3RK1 322-0DS02- 1AA0 1AA1 1AA4 0.28 - 0.40 3RK1 322-0ES02- 1AA0 1AA1 1AA4 0.35 - 0.50 3RK1 322-0FS02- 1AA0 1AA1 1AA4 0.45 - 0.63 3RK1 322-0GS02- 1AA0 1AA1 1AA4 0.55 - 0.80 3RK1 322-0HS02- 1AA0 1AA1 1AA4 0.70 - 1.00 3RK1 322-0JS02- 1AA0 1AA1 1AA4 0.90 - 1.25 3RK1 322-0KS02- 1AA0 1AA1 1AA4 1.10 - 1.60 3RK1 322-1AS02- 1AA0 1AA1 1AA4 1.40 - 2.00 3RK1 322-1BS02- 1AA0 1AA1 1AA4 1.80 - 2.50 3RK1 322-1CS02- 1AA0 1AA1 1AA4 2.20 - 3.20 3RK1 322-1DS02- 1AA0 1AA1 1AA4 2.80 - 4.00 3RK1 322-1ES02- 1AA0 1AA1 1AA4 3.50 - 5,00 3RK1 322-1FS02- 1AA0 1AA1 1AA4 4.50 - 6.30 3RK1 322-1GS02- 1AA0 1AA1 1AA4 5.50 - 8.00 3RK1 322-1HS02- 1AA0 1AA1 1AA4 7.00 - 10.0 3RK1 322-1JS02- 1AA0 1AA1 1AA4 9.00 - 12.0 3RK1 322-1KS02- 1AA0 1AA1 1AA4 English 0.14 - 0.20  * For assignment to performance of 400 V AC squirrel-cage motors see Appendix A.2 GWA 4NEB 640 0909-32 DS02 B-3 Order Numbers B.2 Electronic Compact Starters EDS2DI and ERS2DI Deutsch Direct-on-line Starters EDS2DI Adjustment range* Order number Order number-extension Basic version A English Versions with braking contact 24 V DC 400 V AC 500 V DC 0.6 - 2.18 3RK1 322-0AS12- 0AA0 0AA1 0AA3 0AA4 2.0 - 5.95 3RK1 322-0BS12- 0AA0 0AA1 0AA3 0AA4 Order number Order number-extension Reversing Starters ERS2DI Adjustment range* A Basic version Versions with braking contact 24 V DC 400 V AC 500 V DC 0.6 - 2.18 3RK1 322-0AS12- 1AA0 1AA1 1AA3 1AA4 2.0 - 5.95 3RK1 322-0BS12- 1AA0 1AA1 1AA3 1AA4  * For assignment to performance of 400 V AC squirrel-cage motors see Appendix A.2 B-4 GWA 4NEB 640 0909-32 DS02 Order Numbers Description Order number No of items per pack 3RK1 902-0AP00 Seals for mounting plate (5 straight seals, with profile) 10 3RK1 902-0AR00 Crimping tool for contact pins and jacks 1.5 to 2.5 mm2 3RK1 902-0AH00 Crimping tool for contact pins and jacks 2.5 to 4.0 mm2 3RK1 902-0CT00 Dismantling tool for contact pins and jacks 3RK1 902-0AJ00 Screw caps for power sockets 10 3RK1 902-0CK00 3RK1 902-0CJ00 Screw caps for M12 sockets 10 3RK9 802-0AA00 Hand-held controller with 0.5 m connecting cable 3RK1 902-0AM00 Addressing line 3RK1 901-3HA01 Y-connector 6ES7 194-1KA00-0XA0 Manual for AS-Interface Compact Starter, german/english 3RK1 702-2GB10-2AA0 Manual for AS-Interface Compact Starter, french/italian 3RK1 702-2HB10-2AA0 Power connecting cable x 4.0 mm2, 0.12 m long 3RK1 902-0CH00 Power connecting cable x 4.0 mm2, 0.12 m long 3RK1 902-0CG00 Set of connectors for power supply 2.5 mm2:  connector shell with PG 16, socket insert and jacks 2.5 mm2 3RK1 902-0CA00 Set of connectors for power supply 4.0 mm2:  connector shell with PG 16, socket insert and jacks 4.0 mm2 3RK1 902-0CB00 Set of connectors for looping through power/connecting motor 2.5 mm2:  connector shell with PG 16, pin insert and contact pins 2.5 mm2 3RK1 902-0CC00 Set of connectors for looping through power 4.0 mm2:  connector shell with PG 16, pin insert and contact pins 4.0 mm2 3RK1 902-0CD00 Set of connectors for connecting motor 1.5 mm2:  connector shell with PG 16, pin insert and contact pins 1.5 mm2 3RK1 902-0CE00 Motor connecting cable x 1.5 mm2, m long, with plug 3RK1 902-0CM00 Motor connecting cable x 1.5 mm2, m long, with plug 3RK1 902-0CP00 Motor connecting cable x 1.5 mm2, 10 m long, with plug 3RK1 902-0CQ00 Motor connecting cable x 1.5 mm2, m long, with plug 3RK1 902-0CN00 Motor connecting cable x 1.5 mm2, m long, with plug 3RK1 902-0CR00 Motor connecting cable x 1.5 mm2, 10 m long, with plug 3RK1 902-0CS00 English Mounting plate for AS-i compact starter Deutsch B.3 Accessories Accessories for 9-pole connections GWA 4NEB 640 0909-32 DS02 B-5 Order Numbers Deutsch English B-6 GWA 4NEB 640 0909-32 DS02 Deutsch Numerics 3-wire sensors 3-17 F FAULT signal 4-10, 4-12 A Actuator-Sensor Interface (AS-i) 1-2 Addressing DS2DI, RS2DI 4-2 EDS2DI, ERS2DI 4-8 AS-i Master 1-2 AS-i Slave 1-2 Automatic mode 5-5 English Index G Galvanic isolation 3-11, 3-15, 3-16 B Braking current circuit 6-4 C Circuit-breaker 6-5 Compact starter DS2DI 1-3 EDS2DI 1-4 ERS2DI 1-4 RS2DI 1-3 with a 24 V DC braking contact 3-8 with a 400 V AC braking contact 3-12 with a 500 V DC braking contact 3-12 without a braking contact 3-4 Configuration with AS-i compact starters 1-5 Contactor 6-5 Contact-type signal transmitters 3-17 Continuous mode 5-2, 5-3 Currents 6-3 D Dangerous system states 4-7, 4-15, 5-2, 5-3 Degree of protection IP 65 3-3, 6-2 Direct shutdown 4-10 E Electromechanical motor starter 1-3 Electronic motor starter 1-4 Electronic overload protection 4-10 External short-circuit protection 4-3 GWA 4NEB 640 0909-32 DS02 H Hand-held controller 5-2 I Input signals DS2DI, RS2DI 4-6 EDS2DI, ERS2DI 4-14 IP 65 3-3, 6-2 J Jogging mode 5-2, 5-3 L LEDs compact starter DS2DI and RS2DI 4-5 compact starter DS2DI, RS2DI 1-3 compact starter EDS2DI and ERS2DI 4-13 compact starter EDS2DI, ERS2DI 1-4 hand-held controller 5-4 Local reset 4-11, 4-12 M Main circuit 6-3 Manual mode 5-2, 5-5 Monitoring 5-2 Motor starter electromechanical 1-3 electronic 1-4 O Output signals 4-7 DS2DI, RS2DI 4-15 EDS2DI, ERS2DI 4-14 Overcurrent signal 4-13 Overload release 4-4, 4-10, 4-12 Overload release test 4-3, 4-11 Index-1 Index P Pinout compact starter with a 24 V DC braking contact 3-9 compact starter with a 400 V AC braking contact 3-13 compact starter with a 500 V DC braking contact 3-13 compact starter without a braking contact 3-5 M12 socket 3-17 R Release signal 4-10, 4-12 Remote reset 4-11, 4-12 Remote shutdown 4-10 Reset after FAULT signal 4-12 after overload release 4-12 after release signal 4-12 Rotary encoder switches 4-9 Index-2 S Safeguard against accidental opening 4-4, 4-11 Screw caps 3-3 Set current Ie 4-3, 4-9 Set values 4-9 Stop interval 4-3 T Testing the motor 5-2 Tripping REMOTE/LOCAL  rotary encoder switch 4-10 V Voltages 6-3 GWA 4NEB 640 0909-32 DS02 Sender (please fill out) Name Company / Department SIEMENS AG A&D CD MM Postfach 1954 92220 Amberg Address Telephone Fax Fax: ++49-9621-80-3337 System Manual AS-Interface Compact Starter with 2DI Have you found any typographical errors while reading this manual? Please use this form to tell us about them. We would also welcome any ideas and suggestions you may have GWA 4NEB 640 0909-32 DS02      Technical Assistance: Telephone: Fax: E-mail: Internet: +49 (0) 911-895-5900 (8°° - 17°° CET) +49 (0) 911-895-5907 technical-assistance@siemens.com www.siemens.de/automation/technical-assistance SIEMENS AG Technical Assistance Würzburger Str 121 D-90766 Fürth SIEMENS AG Industry Sector 90026 NÜRNBERG GERMANY Siemens Aktiengesellschaft Änderungen vorbehalten Changes without prior notice Best.- Nr / Order No.: 3RK1702-2GB10-2AA0 ... DS2DI and RS2DI indicate the following statuses: LED Function Indication AS- i AS- i communication Steady green light Status AS- i communication OK English Diagnosis via LEDs Steady red light Auxiliary... DS02 Commissioning Diagnosis via LEDs During operation, the LEDs on the compact starters EDS2DI and ERS2DI indicate the following statuses: Function Indication Status AS- i AS- i communication Steady... V) Simultaneous activation of clockwise and anticlockwise rotation Overcurrent signal Flashing red Main circuit on Overload release test Flashing red Flashes quickly Flashes slowly Main circuit

Ngày đăng: 05/06/2015, 17:44

Từ khóa liên quan

Mục lục

  • AS-Interface Compact Starter

    • Overview

    • Safety guidelines

    • Contents

    • 1 System Description

      • 1.1 What is the Actuator-Sensor Interface (AS-i)?

      • 1.2 What are the AS-i Compact Starters DS2DI and RS2DI?

      • 1.3 What are the AS-i Compact Starters EDS2DI and ERS2DI?

      • 1.4 Connection Example

      • 2 Installation

        • 2.1 Installing the Compact Starter

        • 2.2 Dimensions

        • 3 Wiring

          • 3.1 Rules for Wiring

          • 3.2 Compact Starters without a Braking Contact

            • 3.2.1 Making up Connecting Cables

            • 3.2.2 Wiring the Power Connectors

            • 3.2.3 Electrical Design

            • 3.3 Compact Starters with a 24 V DC Braking Contact

              • 3.3.1 Making up Connecting Cables

              • 3.3.2 Wiring the Power Connectors

              • 3.3.3 Electrical Design

              • 3.4 Compact Starters with a 400 V AC resp. 500 V DC Braking Contact

                • 3.4.1 Making up Connecting Cables

                • 3.4.2 Wiring the Power Connectors

                • 3.4.3 Electrical Design

                • 3.5 Additional Inputs IN1 and IN2