1. Trang chủ
  2. » Kỹ Thuật - Công Nghệ

Nissan navara np300 (d23) esm tai lieu sua chua phan 8 2

65 11 0

Đang tải... (xem toàn văn)

Tài liệu hạn chế xem trước, để xem đầy đủ mời bạn chọn Tải xuống

THÔNG TIN TÀI LIỆU

Thông tin cơ bản

Định dạng
Số trang 65
Dung lượng 31,84 MB
File đính kèm Nissan Navara NP300_Tai lieu sua chua phan 8-2.zip (31 MB)

Nội dung

Tài liệu hướng dẫn sửa chữa xe Nissan navara np300 (d23) esm tai lieu sua chua phan 8 2 . Cung cấp các thông tin cần thiết cho Kỹ thuật viên tiến hành chẩn đoán, sửa chữa nhanh chóng, chính xác, hiệu quả

HARNESS LAYOUT < WIRING DIAGRAM > PASSENGER COMPARTMENT JRMIC5525GB Revision: 2014 December PG-136 D23 HARNESS LAYOUT < WIRING DIAGRAM > LHD : Engine Control Harness INFOID:0000000011863161 A B C D E F G H I J K L PG N O JRMIC5526GB Revision: 2014 December PG-137 P D23 HARNESS LAYOUT < WIRING DIAGRAM > LHD : Main Harness INFOID:0000000011863162 JRMIC5523GB Revision: 2014 December PG-138 D23 HARNESS LAYOUT < WIRING DIAGRAM > LHD : Body Harness INFOID:0000000011863163 A BODY HARNESS B C D E F G H I J K L PG N O P JRMIC5527GB Revision: 2014 December PG-139 D23 HARNESS LAYOUT < WIRING DIAGRAM > BODY No.2 HARNESS JRMIC5528GB Revision: 2014 December PG-140 D23 HARNESS LAYOUT < WIRING DIAGRAM > LHD : Chassis Harness INFOID:0000000011863164 A B C D E F G H I J K L PG N O JRMIC5529GB Revision: 2014 December PG-141 P D23 HARNESS LAYOUT < WIRING DIAGRAM > LHD : Door Harness INFOID:0000000011863165 FRONT DOOR HARNESS (RH SIDE) JRMIC5531GB Revision: 2014 December PG-142 D23 HARNESS LAYOUT < WIRING DIAGRAM > FRONT DOOR HARNESS (LH SIDE) A B C D E F G H I J K L PG N O JRMIC5532GB P Revision: 2014 December PG-143 D23 HARNESS LAYOUT < WIRING DIAGRAM > REAR DOOR HARNESS (RH SIDE) JRMIC5533GB Revision: 2014 December PG-144 D23 HARNESS LAYOUT < WIRING DIAGRAM > REAR DOOR HARNESS (LH SIDE) A B C D E F G H I J K L PG N O JRMIC5534GB P Revision: 2014 December PG-145 D23 FUSE INSPECTION < BASIC INSPECTION > • Under normal conditions, keep the extended storage fuse switch in ON state Never operate the extended storage fuse switch except when necessary • Type A and D JSMIA0472ZZ - To turn the extended storage fuse switch OFF, pull it up in direction as shown in the figure - To turn the extended storage fuse switch ON, press it in direction as shown in the figure • Type B JSMIA0473ZZ - To turn the extended storage fuse switch OFF, hold of the switch and pull up in direction as shown in the figure - To turn the extended storage fuse switch ON, press it in direction as shown in the figure • Type C JSMIA0794ZZ - To turn the extended storage fuse switch OFF, pull it up in direction as shown in the figure - To turn the extended storage fuse switch ON, press it in direction as shown in the figure Revision: 2014 December PG-186 D23 FUSE INSPECTION < BASIC INSPECTION > How To Remove Extended Storage Fuse Switch A Type A and D Turn the ignition switch OFF Turn the extended storage fuse switch OFF Press pawl and tilt to disengage the extended storage fuse switch Press pawl and tilt to remove the extended storage fuse switch B C D JSMIA0476ZZ NOTE: • Extended storage fuse switch and fuse are removed together Remove fuse from extended storage fuse switch, if necessary • Extended storage fuse switch is for transportation and storage Reinstallation is not required after the removal E F G Type B Turn the ignition switch OFF Turn the extended storage fuse switch OFF Hold and pull up the extended storage fuse switch hard in direction H I J K JSMIA0477ZZ NOTE: L • Extended storage fuse switch and fuse may be removed together Remove fuse from extended storage fuse switch, if necessary • Extended storage fuse switch is for transportation and storage Reinstallation is not required after the PG removal Type C Turn the ignition switch OFF Turn the extended storage fuse switch OFF Hold and pull up the extended storage fuse switch hard in direction N O P JSMIA0795ZZ NOTE: Revision: 2014 December PG-187 D23 FUSE INSPECTION < BASIC INSPECTION > • Extended storage fuse switch and fuse are removed together Remove fuse from extended storage fuse switch, if necessary • Extended storage fuse switch is for transportation and storage Reinstallation is not required after the removal Revision: 2014 December PG-188 D23 FUSIBLE LINK INSPECTION < BASIC INSPECTION > FUSIBLE LINK INSPECTION A How To Check INFOID:0000000010508244 A melted fusible link can be detected either by visual inspection or by feeling with finger tip If its condition is questionable, use circuit tester or test lamp B C D E F G JSMIA1732ZZ Fusible link CAUTION: • If fusible link should melt, it is possible that critical circuit (power supply or large current carrying circuit) is shorted In such a case, carefully check and eliminate cause of malfunction • Never wrap outside of fusible link with vinyl tape Important: Never let fusible link touch any other wiring harness, vinyl or rubber parts H I J K L PG N O P Revision: 2014 December PG-189 D23 BATTERY CHARGING CHART < BASIC INSPECTION > BATTERY CHARGING CHART Slow Charge INFOID:0000000010508245 1.DETERMINE INITIAL CHARGING CURRENT Determine initial charging current from specific gravity Check battery type and determine the specified current using the table NOTE: After starting charging, adjustment of charging current is not necessary Initial Charging Current Setting (Slow Charge) 8.0 (A) 10.0 (A) 130E41L/R 95E41L/R 110D26L/R L3/L3-HR 110D26L-MF 9.0 (A) 115D31L/R 8.5 (A) 95D31L/R 067 [YUASA type code] 80D26L/R 65D26L/R 80D23L/R 027 [YUASA type code] 025 [YUASA type code] 55D23L/R 7.0 (A) 75D31L/R 5.0 (A) 50D23L/R 55B24L(S) 55B24L/R 46B24L/R 38B20L/R 34B20L/R 4.0 (A) 096 [YUASA type code] Below 1.100 34B19L/R CONVERTED SPECIFIC GRAVITY 28B19L/R BATTERY TYPE 14 (A) >> GO TO 2.CHARGE BATTERY Charge battery Check charge voltage 30 minutes after starting the battery charge Is the voltage between 12 V and 15 V? YES >> GO TO NO >> Replace battery 3.CHARGE BATTERY Continue to charge for 12 hours >> GO TO 4.CHECKING SPECIFIC GRAVITY Check specific gravity Refer to PG-177, "How to Handle Battery" Is the specific gravity 1.240 or more? YES >> Complete slow charge Perform “CAPACITY TEST” Refer to PG-180, "Work Procedure" NO >> GO TO 5.CONDUCT ADDITIONAL CHARGE Add charging time depending on specific gravity Additional Charge (Slow Charge) SPECIFIC GRAVITY CHARGING TIME (h) Below 1.150 1.150 - 1.200 1.200 - 1.240 >> Complete slow charge Perform “CAPACITY TEST” Refer to PG-180, "Work Procedure" CAUTION: Revision: 2014 December PG-190 D23 BATTERY CHARGING CHART < BASIC INSPECTION > • Set charging current to value specified in “Initial Charging Current Setting (Slow Charge)” If charger is not capable of producing specified current value, set its charging current as close to that value as possible • Keep battery away from open flame while it is being charged • When connecting charger, connect leads first, then turn on charger Never turn on charger first, as this may cause a spark • If battery temperature rises above 55°C (131°F), stop charging Always charge battery when its temperature is below 55°C (131°F) A B C Standard Charge INFOID:0000000010508246 1.DETERMINE INITIAL CHARGING CURRENT D Determine initial charging current from specific gravity Check battery type and determine the specified current using the table NOTE: After starting charging, adjustment of charging current is not necessary E Initial Charging Current Setting (Standard Charge) 130E41L/R 95E41L/R 110D26L/R L3/L3-HR 110D26L-MF 115D31L/R 95D31L/R 75D31L/R F 096 [YUASA type code] 067 [YUASA type code] 80D26L/R 65D26L/R 80D23L/R 027 [YUASA type code] 025 [YUASA type code] 55D23L/R 50D23L/R 55B24L(S) 55B24L/R 46B24L/R 38B20L/R 34B20L/R 34B19L/R CONVERTED SPECIFIC GRAVITY 28B19L/R BATTERY TYPE G H 1.100 - 1.130 4.0 (A) 5.0 (A) 6.0 (A) 7.0 (A) 8.0 (A) 9.0 (A) 13.0 (A) 1.130 - 1.160 3.0 (A) 4.0 (A) 5.0 (A) 6.0 (A) 7.0 (A) 8.0 (A) 11.0 (A) 1.160 - 1.190 2.0 (A) 3.0 (A) 4.0 (A) 5.0 (A) 6.0 (A) 7.0 (A) 9.0 (A) 1.190 - 1.220 2.0 (A) 2.0 (A) 3.0 (A) 4.0 (A) 5.0 (A) 5.0 (A) 7.0 (A) I J K >> GO TO L 2.CHARGE BATTERY Charge battery for hours PG >> GO TO 3.CHECKING SPECIFIC GRAVITY N Check specific gravity Refer to PG-177, "How to Handle Battery" Is the specific gravity 1.240 or more? YES >> Complete standard charge Perform “CAPACITY TEST” Refer to PG-180, "Work Procedure" NO >> GO TO O 4.CONDUCT ADDITIONAL CHARGE P Add charging time depending on specific gravity Additional Charge (Standard Charge) SPECIFIC GRAVITY CHARGING TIME (h) Below 1.150 3.5 1.150 - 1.200 2.5 1.200 - 1.240 1.5 Revision: 2014 December PG-191 D23 BATTERY CHARGING CHART < BASIC INSPECTION > >> Complete standard charge Perform “CAPACITY TEST” Refer to PG-180, "Work Procedure" CAUTION: • Never use standard charge method on a battery whose specific gravity is less than 1.100 • Set charging current to value specified in “Initial Charging Current Setting (Standard Charge)” If charger is not capable of producing specified current value, set its charging current as close to that value as possible • Keep battery away from open flame while it is being charged • When connecting charger, connect leads first, then turn on charger Never turn on charger first, as this may cause a spark • If battery temperature rises above 55°C (131°F), stop charging Always charge battery when its temperature is below 55°C (131°F) Quick Charge INFOID:0000000010508247 1.DETERMINE INITIAL CHARGING CURRENT Determine initial charging current setting and charging time from specific gravity Check battery type and determine the specified current using the table NOTE: After starting charging, adjustment of charging current is not necessary CONVERTED SPECIFIC GRAVITY 15 20 1.100 1.130 2.5 hours 1.130 1.160 2.0 hours 1.160 1.190 1.5 hours 1.190 1.220 1.0 hour Above 1.220 0.75 hour (45 min.) 25 30 30 130E41L/R 95E41L/R 110D26L/R L3/L3-HR 110D26L-MF 115D31L/R 95D31L/R 75D31L/R 096 [YUASA type code] 067 [YUASA type code] 027 [YUASA type code] 025 [YUASA type code] 80D26L/R 65D26L/R 80D23L/R 55D23L/R 50D23L/R 55B24L(S) 12 55B24L/R 11 46B24L/R 38B20L/R 10 34B20L/R CURRENT [A] 34B19L/R BATTERY TYPE 28B19L/R Initial Charging Current Setting and Charging Time (Quick Charge) 40 CAUTION: • Never use quick charge method on a battery whose specific gravity is less than 1.100 • Set initial charging current to value specified in “Initial Charging Current Setting and Charging Time (Quick Charge)” If charger is not capable of producing specified current value, set its charging current as close to that value as possible • Keep battery away from open flame while it is being charged • When connecting charger, connect leads first, then turn on charger Never turn on charger first, as this may cause a spark • Be careful of a rise in battery temperature because a large current flow is required during quickcharge operation If battery temperature rises above 55°C (131°F), stop charging Always charge battery when its temperature is below 55°C (131°F) • Never exceed the charging time specified in “Initial Charging Current Setting and Charging Time (Quick Charge)”, because charging battery over the charging time can cause deterioration of the battery Revision: 2014 December PG-192 D23 BATTERY CHARGING CHART < BASIC INSPECTION > >> GO TO 2.CHARGE BATTERY A Charge battery B >> Complete quick charge Perform “CAPACITY TEST” Refer to PG-180, "Work Procedure" C D E F G H I J K L PG N O P Revision: 2014 December PG-193 D23 BATTERY < REMOVAL AND INSTALLATION > REMOVAL AND INSTALLATION BATTERY Exploded View INFOID:0000000010521269 JSMIA1735GB Battery fix rod Battery positive terminal cover Battery positive terminal Battery cover Battery tray Battery Battery negative terminal Battery fix frame :N·m (kg-m, in-lb) :N·m (kg-m, ft-lb) Removal and Installation INFOID:0000000010521270 REMOVAL Revision: 2014 December PG-194 D23 BATTERY < REMOVAL AND INSTALLATION > Disconnect the battery cable from the negative terminal CAUTION: To prevent damage to the parts, disconnect the battery cable from the negative terminal first Remove cover of battery positive terminal Disconnect the battery cable from the positive terminal Remove battery fix frame mounting nuts, and then remove battery fix frame Remove battery cover Remove battery A B C INSTALLATION Install in the reverse order of removal CAUTION: To install the battery, carefully read the following instructions • To prevent damage to the parts, connect the battery cable to the positive terminal first • After connecting battery cables, to securely supply battery voltage, ensure that they are tightly clamped to battery terminals for good contact • To securely supply battery voltage, check battery terminal for poor connection caused by corrosion Reset electronic systems as necessary Refer to GI-58, "ADDITIONAL SERVICE WHEN REMOVING BATTERY NEGATIVE TERMINAL : Required Procedure After Battery Disconnection" D E F G H I J K L PG N O P Revision: 2014 December PG-195 D23 BATTERY TRAY < REMOVAL AND INSTALLATION > BATTERY TRAY Exploded View INFOID:0000000010521271 JSMIA1735GB Battery fix rod Battery positive terminal cover Battery positive terminal Battery cover Battery tray Battery Battery negative terminal Battery fix frame :N·m (kg-m, in-lb) :N·m (kg-m, ft-lb) Removal and Installation INFOID:0000000010521272 REMOVAL Remove battery Refer to : PG-194, "Removal and Installation" Revision: 2014 December PG-196 D23 BATTERY TRAY < REMOVAL AND INSTALLATION > Remove battery tray mounting bolts tray from vehicle , and then remove battery A B C JSMIA1739ZZ D INSTALLATION Install in the reverse order of removal E F G H I J K L PG N O P Revision: 2014 December PG-197 D23 BATTERY TERMINAL WITH FUSIBLE LINK < REMOVAL AND INSTALLATION > BATTERY TERMINAL WITH FUSIBLE LINK Exploded View INFOID:0000000010521273 Battery terminal with fusible link Harness connector : N·m (kg-m, ft-lb) JSMIA1737GB Removal and Installation INFOID:0000000010521274 REMOVAL Disconnect the battery cable from the negative terminal Refer to PG-194, "Exploded View" CAUTION: To prevent damage to the parts, disconnect the battery cable from the negative terminal first Remove cover of battery positive terminal Disconnect the battery cable from the positive terminal Refer to PG-194, "Exploded View" Remove harness mounting nut and battery terminal with fusible link mounting nut Disconnect harness connector and remove battery terminal with fusible link INSTALLATION Install in the reverse order of removal CAUTION: To prevent damage to the parts, connect the battery cable to the positive terminal first Revision: 2014 December PG-198 D23 BATTERY CURRENT SENSOR < REMOVAL AND INSTALLATION > BATTERY CURRENT SENSOR A Exploded View INFOID:0000000010508252 B Harness connector Battery current sensor C : N·m (kg-m, ft-lb) D JSMIA1738GB Removal and Installation E INFOID:0000000010508253 REMOVAL F G Disconnect the battery cable from the negative terminal Refer to PG-194, "Exploded View" Disconnect the battery current sensor harness connector Remove the battery current sensor mounting nut Remove the battery current sensor from battery negative cable H INSTALLATION Install in the reverse order of removal I J K L PG N O P Revision: 2014 December PG-199 D23 SERVICE DATA AND SPECIFICATIONS (SDS) < SERVICE DATA AND SPECIFICATIONS (SDS) SERVICE DATA AND SPECIFICATIONS (SDS) SERVICE DATA AND SPECIFICATIONS (SDS) Battery INFOID:0000000010521280 Engine YD25DDTi Type 20 hour rate capacity Cold cranking current (For reference value) Revision: 2014 December [V – Ah] [A] QR25DE (Except Thailand) YS23DDT QR25DE (For Thailand) 110D26L-MF L3-HR L3 12 – 75 12 – 75 12 – 75 720 720 720 PG-200 D23

Ngày đăng: 11/12/2023, 10:05

TỪ KHÓA LIÊN QUAN