1. Trang chủ
  2. » Luận Văn - Báo Cáo

Real-time Monitoring technology of Mass spectrometry Speaker

34 576 0

Đang tải... (xem toàn văn)

Tài liệu hạn chế xem trước, để xem đầy đủ mời bạn chọn Tải xuống

THÔNG TIN TÀI LIỆU

Thông tin cơ bản

Định dạng
Số trang 34
Dung lượng 7,8 MB

Nội dung

Real-time Monitoring technology of Mass spectrometry Speaker : Achong Outline IMS PTR-MS SIFT-MS Application of IMS IMS-TOF IMS-IMS-TOF Application of PTR-MS PIT-MS Real-time Monitoring Mass spectrometry Environmental science Biochemical and medical diagnosis Workplace safety Security check EI source Analysis of atmospheric air is especially challenging using electron ionization mass spectrometry, because the gas loading of the ion source by N2 and O2 (as well as water vapor) can be excessive. 70 ev Real-time Monitoring MS Soft chemical ionization Measurement in Real-Time Without pre-concentration system I. IMS (ion mobility spectrometer) Ion mobility mass spectrometry (Eiceman,1991; Baumbach, 2001) Analytical Chemistry, A390-A397, November 1, 2004 Ion mobility (K) Journal of Bimolecular Technique, Vol.13, Issue 2, June, 2002 Ion Mobility-Mass Spectroscopy Witt & Bowers: JACS. 2000, 122, 3458. Ion mobility mass spectrometry Advantages: Multiform ion source could be applied. Some isomer could be separated. Real-time measurement Disadvantages: Lower mass resolution Lower sensitivity to allow accurate analysis of complex mixtures. Standard is requisite II. PTR-MS (proton-transfer reaction) Proton-transfer reaction-mass spectrometry (Lagg A, Taucher J, Hansel A, Lindinger W. 1994.) http://info.uibk.ac.at/c/c7/c722/umwelt/html/animation.html [...]... http://www.syft.com/ SIFT mass spectrometry Advantages: application of multiple reagent ions (H3O+, NO+ and O2+) quantification in real-time discriminate isomers in Real-Time Disadvantages: The kinetic parameters of the reagent ion and the analyte ion must be known Selected ion flow tube mass spectrometry for no-line trace gas analysis David Smith and Patrik Spanel Reference : Mass Spectrometry Reviews,... [H3O+]o(1 - e-k[R]t) = [H30+]o[R]kt J Mass Spectrom Ion Processes, 173 (1998) 191-241 J Mass Spectrom Ion Processes, 173 (1998) 191-241 J Mass Spectrom Ion Processes, 173 (1998) 191-241 PTR mass spectrometry Advantages: Soft ionization and low matrix effect Real-time measurement Low limit of detection (0.5 ppbv for 1-min measurements) Disadvantages: A large number of VOCs could not be identified and... Reviews, 2005, 24, 661– 700 Application of IMS IMS/TOF IMS/IMS/TOF Ion Mobility/TOFMS Anal Chem 2003, 75,6202-6208 Pulse sequence of IMS & TOF Anal Chem 2003, 75,6202-6208 example spectrum Analytical Chemistry, 1998 Vol 70, No 11, June 1, Anal Chem 2003, 75,6202-6208 collision-induced dissociation http://proteomics.med.ncku.edu.tw/proteomicsweb/Liao_94_1007.ppt IMS/IMS/TOF Anal Chem 2006, 78,4161-4174 operational... 78,4161-4174 Application of PTRMS PIT-MS PIT-MS http://cires.colorado.edu/~gouw/Instruments/PITMS/PITMS.html PIT-MS proton-transfer ion trap -mass spectrometry J Am Soc Mass Spectrom 2005, 16, 1316–1324 CID process on ion-trap MS http://www.chem.agilent.com/cag/Other/IonTrap_fig2.gif calibration measurement of the PIT-MS J Am Soc Mass Spectrom 2005, 16, 1316–1324 single CID measurement of m/z 59 ambient air... calibration measurement of the PIT-MS J Am Soc Mass Spectrom 2005, 16, 1316–1324 single CID measurement of m/z 59 ambient air pure acetone pure propanal J Am Soc Mass Spectrom 2005, 16, 1316–1324 CID of propanal and acetone m/z=59 m/z=41 m/z=31 J Am Soc Mass Spectrom 2005, 16, 1316–1324

Ngày đăng: 28/04/2014, 13:18

TỪ KHÓA LIÊN QUAN

TÀI LIỆU CÙNG NGƯỜI DÙNG

TÀI LIỆU LIÊN QUAN