1. Trang chủ
  2. » Tất cả

151 liposomal surface coatings of metal coronary artery stents for efficient non viral gene delivery to the injured vasculature

2 1 0

Đang tải... (xem toàn văn)

THÔNG TIN TÀI LIỆU

151 Liposomal Surface Coatings of Metal Coronary Artery Stents for Efficient Non Viral Gene Delivery to the Injured Vasculature Molecular Therapy Volume 20, Supplement 1, May 2012 Copyright © The Amer[.]

CARDIOVASCULAR GENE & CELL THERAPY Due to the extremely short half life of prostacyclin in plasma (42 seconds), it is usually measured indirectly by measuring its stable metabolite, 6-keto-prostaglandin 1α(6KP) Measurements were performed 48 hours after hydrodynamic gene delivery by delivering a fatal dose of ketamine and drawing blood via cardiac puncture 6KP was extracted from plasma using a C18 column and detecting with a 6KP ELISA kit (Cayman Chemical, Ann Arbor, MI, USA) Results: 6KP levels in the plasma of Cox-1/PGIS treated animals exceeded 18pg/ml, as compared to 2pg/ml for control animals By comparison, 6KP levels in humans, reported in a previous study, were

Ngày đăng: 19/11/2022, 11:36

Xem thêm:

TÀI LIỆU CÙNG NGƯỜI DÙNG

TÀI LIỆU LIÊN QUAN

w