Power Test User Manual PONOVO POWER CO , LTD Nội dung Section 1 PowerTest Concept Section 2 PowerTest Basic Section 3 PowerTest Protection Section 4 PowerTest Advanced Section 5 PowerTest Special PowerTest Concept Content 1 PowerTest Installation and Authorization Instruction 6 1 1 Install PowerTest 6 1 2 Install the authorization files 12 2 Main interface 14 2 1 Test Modules composition 15 2 2 Basic 16 2 3 Protection 17 2 4 Advanced 18 2 5 Special 19 2 6 IEC61850 (Valid only for PWF) 20 2 7 New.
Power Test User Manual PONOVO POWER CO., LTD Nội dung Section PowerTest Concept Section PowerTest Basic Section PowerTest Protection Section PowerTest Advanced Section PowerTest Special PowerTest Concept Content PowerTest Installation and Authorization Instruction .6 Install PowerTest 1.2 Install the authorization files 12 Main interface 14 1.1 Test Modules composition 15 2.2 Basic 16 2.3 Protection 17 2.4 Advanced 18 2.5 Special 19 2.6 IEC61850 (Valid only for PWF) 20 2.7 New Modules 21 Setup 22 3.1 System & IEC 23 3.1.1 System set 23 3.1.2 GOOSE Subscription 26 3.1.3 GOOSE Publish 28 3.2 Aux DC 34 3.3 Binary 36 3.4 License 39 Test Manager 40 4.1 Template 40 4.2 Report 43 4.3 Test Plan 43 Calibration 44 Support 45 Basic instruction of PowerTest 46 7.1 How to select the test module 46 7.1.1 Single choice 46 2.1 PONOVO POWER CO., LTD PowerTest Concept 7.1.2 Multiple choices 47 7.2 Typical test page 48 7.3 Drop-Down Menu 50 7.3.1 Template File (F) 50 7.3.2 Task (T) 51 7.3.3 Report(R) 52 7.3.4 Setting(S) 55 7.3.5 View (W) 56 7.3.6 Help (H) 61 7.4 Quick control buttons 62 7.5 Test Item 65 7.6 Parameters 69 7.7 Assessment 72 7.8 Wiring 73 7.9 Characteristic 74 7.10 Report Setting 75 7.11 GOOSE Data 75 7.12 Group Setting 75 7.13 Group Parameter 76 7.14 Group Binary input and output 78 7.15 Tips 79 7.16 View windows 79 7.17 Task List 83 7.18 Test results 85 7.19 Test status 86 7.20 Binary input 86 7.21 Monitor 87 7.22 Control test process 88 7.23 Binary output 89 PONOVO POWER CO., LTD PowerTest Concept Operations 90 8.1 Set Voltage Output 300V 90 8.2 How to Output 600V 92 8.3 How to generate test template 95 8.4 How to user-define distance curve 98 8.5 GPS Instruction 106 8.6 Binary input configuration in QuickTest modules 108 8.7 How to change the IP in the PC 110 PONOVO POWER CO., LTD PowerTest Concept Hướng dẫn cài đặt kích hoạt quyền PowerTest 1.1 Cài đặt PowerTest Tải xuống tệp thiết lập từ Đĩa USB internet Nhấp đúp vào chương trình thiết lập để cài đặt Nó bật lên trình hướng dẫn cài đặt nhấp vào Next để tiếp tục PONOVO POWER CO., LTD PowerTest Concept Sau đó, bật lên Thỏa thuận cấp phép Chọn “I accept the agreement” and click “Next” để tiếp tục Bây thơng tin cài đặt Nhấn Next để tiếp tục PONOVO POWER CO., LTD PowerTest Concept Chọn vị trí đích Đường dẫn C: \ PowerTest 'được khuyến nghị Chọn thành phần bạn mong muốn Đề nghị cài đặt thành phần hoàn chỉnh PONOVO POWER CO., LTD PowerTest Concept Điền vào tên thư mục cài đặt Đó đề nghị để giữ cho gốc Chọn tác vụ bổ sung tạo biểu tượng hình tạo biểu tượng khởi chạy nhanh PONOVO POWER CO., LTD PowerTest Concept Xác nhận tất thông tin cài đặt nhấn vào Cài đặt cài đặt trực tuyến để hồn thành Q trình cài đặt trình PONOVO POWER CO., LTD 10 PowerTest Special 3.5 Set group binary Only binary output will be set here Out Binary Output, Open or Close Output Mode Two modes available, Bin.In and Time OutputTime The output time delay OutputHoldTime Output hold time delay 25 PONOVO POWER CO., LTD PowerTest Special 3.6 View power swing parameters Switch the view button to display swing model and parameters Then the follow window will pop up The power swing center is calculated by taking account of system settings set in group parameters The position of power swing center can be changed by changing the system settings 26 PONOVO POWER CO., LTD PowerTest Special 3.7 Set test point/ item parameters Name Edit here the name for the current test point Pow Angle Start Start power angle Pow Angle End It will be activated when ‘from-to-from’ is selected in ‘Swing Mode’ Swing Cycle The time is used to complete on cycle of power swing (normally set range: 2-5s) Swing Number It is the number of power swing cycle to simulate |Em|/|En| It is the ratio of Em/En The ratio of Em/En will influence the position of power swing center 27 PONOVO POWER CO., LTD PowerTest Special Swing mode selection from-to-from Swing angle will change from angle start to angle end and then from angle end to angle start Increase speed Swing angle will change from angle start to angle end Decrease speed Swing angle will change from angle end to angle start Trip Contact Assign the binary input for sensing the tripping signal from the relay Available binary inputs are A, B, E, F, G,H Acc Signal Contact Incoming Acceleration signal from relay, defined binary input as C Dec Signal Contact Incoming Deceleration signal from relay, defined binary input as D The above two parameters are mostly used when testing out-of-step relay 28 PONOVO POWER CO., LTD PowerTest Special Fault type |Zf| Fault impedance If Fault current Fault time Reference This indicates when the fault will occur after power swing starts KE given as Type There are three types of KE mode available and we need to select the one according to the relay under test KE Module: It is the value of KE Anlge: It is the angle of KE RE/RL & XE/XL Kr: It is the resistance factor Kx: It is the reactive factor ZE/Z1 Module: It is the value of ZE/Z1 Anlge: It is the angle of ZE/Z1 dz/dt Impedance change rate per second The dz/dt will be activated after the dz/dt column is selected When the dz/dt is chosen, the Swing Cycle will be disabled Add Copy the same test point/item at the cursor position Remove Remove the present test point/item, but if there is only one test point/item, it is not allowed to be removed Clear Clear the test results at the present test point/item 29 PONOVO POWER CO., LTD PowerTest Special 3.8 Set Results Click “Results” to enter into the assessment setting and result display page Note: The result area only displays the values of Trip Acc Signal and Dec Signal that can’t be edited 3.9 Set wiring Please refer to Chapter 7.8 Wiring in PowerTest Concept 30 PONOVO POWER CO., LTD PowerTest Special 3.10 Set characteristic Please refer to Chapter 1.7 Input characteristic in PowerTest Protection 3.11 Set GOOSE Data Please refer to Chapter 3.1.3 GOOSE Data in PowerTest Concept 31 PONOVO POWER CO., LTD PowerTest Special 3.12 Power swing example In this example we have made the following settings 32 PONOVO POWER CO., LTD PowerTest Special Transducer This module is used to check the accuracy of transducer Example: test procedure for one typical transducer Transducer parameters Transducer type Transducer connection Transducer range Transducer output type and range Rate voltage: PT ratio Rate current CT ratio Var phase, wires 0-350MVar Current, 0-4mA 110V 400KV/110V 1A 1000A/1A 33 PONOVO POWER CO., LTD PowerTest Special Test connection Set test parameters Name Edit the name here for the current test point Vnom (L-N) It is the nominal L-N voltage of transducer input Current It is the output current to be injected into transducer Angle It is the angle between output voltage and current based on power 34 PONOVO POWER CO., LTD PowerTest Special Frequency It is the fixed frequency at 50Hz Class The accuracy class of transducer and this setting will be used as the assessment criterion Stablizing time The average measuring values during this time will be used to reflect the actual accuracy of the transducer under test Transducer settings Type Select Reactive power test, based on our test requirement Single phase, three phase Select single phase or three phase based on the type of transducer tested Input range It is the measuring range of transducer Output range It is the output range of transducer Output Unit It is the output type of transducer Input Value It is the value with accordance of the current or voltage Primary Side Set the primary side rating in case transducer input reflects the primary side value The CT and PT ratio part will be activated after selecting primary side InputValue according to Angle It is activated when the transducer type is active power or reactive power 35 PONOVO POWER CO., LTD PowerTest Special Add test point Click “Add” to add one new point each time Click “Add Sweep” to add more test points each time Start Start value of the test points Stop Stop value of the test points Step Step value Confirm the setting and we see new test points added in the test list 36 PONOVO POWER CO., LTD PowerTest Special Time Inversed Current (SP) This module is valid for PONOVO relay test PW636i only The operation is the same with module Time Inversed Current in Protection Please refer to Chapter Time inversed current in PowerTest Protection Here we invite you to focus on the wiring connection especially for the following reasons: The maximum current of single port for PW636i is 32A The test cable maximum bears 32A For the two reasons, we adapt different wiring connection showing in below picture Wiring connection 37 PONOVO POWER CO., LTD PowerTest Special Here we take IA and Ia connection as an example Two cables are connected with IA and Ia separately at PW636i, while at relay, the two cables should be connected in parallel See the site connection as below 38 PONOVO POWER CO., LTD Professional Solution Provider For Protection Relay Test PONOVO POWER CO., LTD No.139 Jinghai Third Road, BDA, Beijing, China 100176 Tel : +86 (10) 59089666 Fax : +86 (10) 59089999 www.relaytest.com ...Nội dung Section PowerTest Concept Section PowerTest Basic Section PowerTest Protection Section PowerTest Advanced Section PowerTest Special PowerTest Concept Content PowerTest Installation... PONOVO POWER CO., LTD 32 PowerTest Basic Concept Ghi chú: SMV khả dụng cho PWF thử nghiệm rơle Vui lịng tham khảo hướng dẫn hình thức đầu SMV Hướng dẫn sử dụng- IEC61850EN PONOVO POWER CO., LTD 33 PowerTest... PONOVO POWER CO., LTD PowerTest Concept Chọn vị trí đích Đường dẫn C: PowerTest 'được khuyến nghị Chọn thành phần bạn mong muốn Đề nghị cài đặt thành phần hoàn chỉnh PONOVO POWER CO., LTD PowerTest