Sơ đồ kết nối PLC Keyence với HMI Delta, hướng dẫn truyền thông, lập trình PLC Keyence, Vẽ màn hình HMI Delta. Series HMI Connection Manual Keyence KV1000 HMI Factory Setting Baud rate 9600 8 Even (RS232) Controller Station Number 0 (no PLC station number in protocol, one on one connection) Control Area Status Area DM 0DM 10 Connection a RS 232 (DOP AAEAS, DOP B Series) Definition of PLC ReadWrite Address a Registers Format Type Word No (n) ReadWrite Range Data Length Note Data Memory DM n DM 0 ~ DM 65535 Word Control Memory CM n CM 0 ~ CM 11999 Word Temporary Data Memory TM n TM 0 ~ TM 511 Word E.
Series HMI Connection Manual Hướng dẫn kết nối PLC với HMI Delta DOP Keyence KV1000 HMI Factory Setting: Baud rate: 9600 Even (RS232) Controller Station Number: (no PLC station number in protocol, one on one connection) Control Area / Status Area: DM-0/DM-10 Connection a RS-232 (DOP-A/AE/AS, DOP-B Series) DOP series Controller pin D-sub male (RS-232) RXD (2) (5) SD TXD (3) (3) RD GND (5) (4) SG Definition of PLC Read/Write Address a Registers Type Format Word No (n) Read/Write Range Data Length Data Memory DM-n DM-0 ~ DM-65535 Word Control Memory CM-n CM-0 ~ CM-11999 Word Temporary Data Memory TM-n TM-0 ~ TM-511 Word Extended Data Memory EM-n EM-0 ~ EM-65535 Word Extended Data Memory FM-n FM-0 ~ FM-32767 Word Address Register Z-n Z-1 ~ Z-12 Word Digital Trimmer AT-n AT-0 ~ AT-7 Word High-speed Counter CTH-n CTH-0 ~ CTH-1 Double Note Word CTC Preset Value PCTC-n PCTC-0 ~ PCTC-3 Double Word Timer Preset Value PT-n PT-0 ~ PT-3999 Double Word Counter Preset Value PC-n PC-0 ~ PC-3999 Double Word V1.01 Revision May, 2011 www.plc.today 71 Series HMI Connection Manual Type High-speed Counter Format Word No (n) CTC-n Data Length Read/Write Range CTC-0 ~ CTC-3 Double Comparator Timer Note Word T-n T-0 ~ T-3999 Double Word Counter C-n C-0 ~ C-3999 Double Word b Contacts Format Type Word No (n) Bit No (b) Read/Write Range Control Relay CR-nbb CR-000 ~ CR-3915 Internal Memory Relay MR-nbb MR-000 ~ MR-99915 Latch LR-nbb LR-000 ~ LR-99915 Relay R-nbb R-000 ~ R-59915 High-speed Counter CTC-b CTC-0 ~ CTC-3 Timer Contact T-b T-0 ~ T-3999 Counter Contact C-b C-0 ~ C-3999 Note comparator 72 V1.01 Revision May, 2011 Series HMI Connection Manual Hướng dẫn kết nối PLC với HMI Delta DOP Keyence KV/KZ Series HMI Factory Setting: Baud rate: 9600, 8, Even, (RS-232) Controller Station Number: (no PLC station number in protocol, one on one connection) Control Area / Status Area: DM-0 / DM-10 Connection a RS-232 (DOP-A, DOP-B Series) KV Series (Note1) DOP series Controller pin D-SUB (RS-232) RJ-11 (RS-232) RXD (2) (5) SD TXD (3) (3) RD GND (5) (4) SG KZ Series (Note1) DOP series Controller pin D-SUB (RS-232) RJ-11 (RS-232) RXD (2) (5) SD TXD (3) (3) RD GND (5) (4) SG Definition of PLC Read/Write Address a Registers Type Format Word No (n) Read/Write Range Data Length Timer T-n T-0 – T-199 Word Counter C-n C-0 – C-199 Word High-speed counter CTH-n CTH-0 – CTH-1 Word High-speed counter CTC-n CTC-0 – CTC-3 Word Note comparator V1.01 Revision August, 2010 www.plc.today 73 Series HMI Connection Manual Type Format Data Length Read/Write Range Word No (n) Data memory DM-n DM-0 – DM-1999 Word Temporary data memory TM-n TM-0 – TM-31 Word Timer preset value PT-n PT-0 – PT-199 Word Counter preset value PC-n PC-0 – PC-199 Word CTC preset value PCTC-n PCTC-0 – PCTC-3 Word Note b Contacts Format Type Read/Write Range Word No (n) Bit No (b) Note Relay R-nbb R-000 – R-6915 Timer T-b T-0 – T-199 Counter C-b C-0 – C-199 CTC-b CTC-0 – CTC-3 High-speed counter comparator NOTE 1) Please be aware the pin definition of SD, RD is reversed in KZ-80T and KV series This protocol regards PLC protocol in KV series, when communicates with KZ series PLC, the following divergence will occur Readable Timer address is not continuous For example: T-0 ~ T-9 can be read T10 cannot be read T11 ~ T20 can be read T21 ~ T50 cannot be read …etc Counter cannot be read For example: Registers: C-, CTH-, CTC-,PC-, PCTC- all cannot be read Contacts: C-, CTC- cannot be read as well 74 V1.01 Revision August, 2010 ... 2011 Series HMI Connection Manual Hướng dẫn kết nối PLC với HMI Delta DOP Keyence KV/KZ Series HMI Factory Setting: Baud rate: 9600, 8, Even, (RS-232) Controller Station Number: (no PLC station... High-speed counter CTC-n CTC-0 – CTC-3 Word Note comparator V1.01 Revision August, 2010 www .plc. today 73 Series HMI Connection Manual Type Format Data Length Read/Write Range Word No (n) Data memory... SD, RD is reversed in KZ-80T and KV series This protocol regards PLC protocol in KV series, when communicates with KZ series PLC, the following divergence will occur Readable Timer address is