Hướng dẫn kết nối màn hình HMI delta với biến tần Fuji

3 8 0
Hướng dẫn kết nối màn hình HMI delta với biến tần Fuji

Đang tải... (xem toàn văn)

Thông tin tài liệu

Hướng dẫn màn hình HMI Delta kết nối với biến tần Fuji Series HMI Connection Manual Fuji Frenic Inverter HMI Factory Setting Baud rate 9600, 8, None, 2 Controller Station Number 1(Note1) Control Area Status Area NoneNone Connection a RS 485 (DOP AAE Series) b RS 485 (DOP AS57 Series) DOP series Terminal Block Controller R+ DX+ R DX DOP series 9 pin D sub male (RS 485) Controller D (1) D (4) DX D+ (2) D+ (3) DX+ 50 V1 00 Revision March, 2010 Series HMI Connection Manual c RS 485 (DOP AS35AS38 Series) d RS 485 (DOP B Series) DOP series 9 pin D su.

Series HMI Connection Manual Fuji Frenic Inverter HMI Factory Setting: Baud rate: 9600, 8, None, Controller Station Number: 1(Note1) Control Area / Status Area: None/None Connection a RS-485 (DOP-A/AE Series) DOP series Controller pin D-sub male (RS-485) D- (1) DXD- (4) D+ (2) DX+ D+ (3) b RS-485 (DOP-AS57 Series) DOP series Controller Terminal Block 50 R+ DX+ R- DX- V1.00 Revision March, 2010 Series HMI Connection Manual Hướng dẫn kết nối PLC với HMI Delta DOP c RS-485 (DOP-AS35/AS38 Series) DOP series Controller Terminal Block (RS-485) R- (1) DXT- (4) R+ (2) DX+ T+ (3) d RS-485 (DOP-B Series) DOP series Controller pin D-sub male (RS-485) D+ (1) DX+ D- (6) DX- Definition of PLC Read/Write Address a Registers Type Format Word No (n) Read/Write Range Data Length Note Fundamental functions Fn F0 – F42 Word Extension terminal En E1 – E47 Word Cn C1 – C33 Word motor Parameters Pn P1 – P9 Word High speed frequency Hn H3 – H39 Word Alternative motor An A1 – A18 Word Optional functions On O1 – O29 Word Setting data function Sn S1 – S12 Word Monitoring data functions Mn M1 – M48 Word functions Control functions of frequency parameters V1.00 Revision March, 2010 www.plc.today 51 Series HMI Connection Manual b Contacts Format Type Read/Write Range Word No (n) Bit No (b) Fundamental functions Fn.b F0.0 – F42.15 Extension terminal En.b E1.0 – E47.15 Cn.b C1.0 – C33.15 motor Parameters Pn.b P1.0 – P9.15 High speed frequency Hn.b H3.0 – H39.15 Alternative motor An.b A1.0 – A18.15 Optional functions On.b O1.0 – O29.15 Setting data function Sn.b S1.0 – S12.15 Monitoring data functions Mn.b M1.0 – M48.15 Note functions Control functions of frequency parameters NOTE 1) Controller Station Number range from to 31, and Number 99 is for radio broadcast 2) Not all address is applicable to radio broadcast Please refer to Fuji Frenic Inverter manual for details on radio broadcast address 3) Not all address can be read and write Please refer to Fuji Frenic Inverter manual for details on read/ write characteristics 52 V1.00 Revision March, 2010 ...Series HMI Connection Manual Hướng dẫn kết nối PLC với HMI Delta DOP c RS-485 (DOP-AS35/AS38 Series) DOP series Controller Terminal... to radio broadcast Please refer to Fuji Frenic Inverter manual for details on radio broadcast address 3) Not all address can be read and write Please refer to Fuji Frenic Inverter manual for details... functions Control functions of frequency parameters V1.00 Revision March, 2010 www.plc.today 51 Series HMI Connection Manual b Contacts Format Type Read/Write Range Word No (n) Bit No (b) Fundamental

Ngày đăng: 08/06/2022, 00:12

Tài liệu cùng người dùng

Tài liệu liên quan