The Morphology of Filamentous Fungi
... viewpoint This point of view is that of a former uni- Fig Development of models The Morphology of Filamentous Fungi versity professor, who started research after the morphology of moulds in 1971 ... ), the number of tips (n) and the length of a hyphal growth unit (Lhgu ) The Lhgu is defined as L t /n 3.2 The Morphology of Filamentous Fungi The various forms of filamentous fungi have advantages ... Length of hyphal growth unit (Lt/n), m mass, kg Mass of a hyphal growth unit, kg per tip Rotational speed of stirrer, s–1 Number of tips in hyphal element, - The Morphology of Filamentous Fungi...
Ngày tải lên: 23/10/2013, 17:20
... ranging from 0.125 to 4µm/ml ii TABLES OF CONTENTS ACKNOWLEDGEMENT i ABSTRACT ii TABLES OF CONTENTS iii LIST OF FIGURES v LIST OF TABLES vi CHAPTER 1 1.1 Background of study 1.2 Research objectives ... colony morphologies of bacterial isolates…………… Page 12 Figure 4.3 Gram stains of V vulnificus, A hydrophila, and S iniae…………Page 13 v LIST OF TABLES Table 4.1 Susceptibility pattern of three bacterial ... API 20E, and API 20STREP, following the instruction of the suppliers 3.3.4 Antimicrobial susceptibility testing The susceptibility patterns of the identified isolates were performed by using disk...
Ngày tải lên: 18/11/2015, 18:46
Nấm sợi (Filamentous Fungi)
... Department of Botany, University of Georgia - M.A.A Schipper, 1973 – A study on variability in Mucorhemalis and related spicies Studies in Mycology, No - M.A.A Schipper, 1978 – On certain species of ... lấy mẫu III Lá tươi vỏ cây: Có nhóm nấm phân lập từ tươi, nhóm thứ nhât nấm bề mặt (phyloplane fungi) Nhóm thứ thuộc nấm gây bệnh, bao gồm ký sinh bắt buộc không bắt buộc Nhóm thứ nấm thực vật ... lập nấm từ mẫu vỏ thực vật khó phân lập loài nấm thực vật gọi nấm nước cạn (terrestrial aquatic fungi) Bởi nhóm nấm sinh trưởng chậm không dễ dàng sinh bào tử nấm bề mặt, nấm gây bệnh hay cácnấm...
Ngày tải lên: 18/08/2012, 20:43
Nấm sợi (Filamentous Fungi)
... Department of Botany, University of Georgia - M.A.A Schipper, 1973 – A study on variability in Mucorhemalis and related spicies Studies in Mycology, No - M.A.A Schipper, 1978 – On certain species of ... Dictyoconidium V Scolecoconidium VI Helicoconidium VII Stauroconidium VIII Miscellaneous fungi IX Synnematous fungi Chúng xin giới thiệu hai khoá phân loại đến chi lớp Nấm Bất toàn Khoá Robert A ... lập nấm từ mẫu vỏ thực vật khó phân lập loài nấm thực vật gọi nấm nước cạn (terrestrial aquatic fungi) Bởi nhóm nấm sinh trưởng chậm không dễ dàng sinh bào tử nấm bề mặt, nấm gây bệnh hay cácnấm...
Ngày tải lên: 18/08/2012, 23:36
... 4.1 Testing programme for Bed Table 4.2 Testing programme for Bed Table 4.3 Testing programme for Bed Table 4.4 Testing programme for Bed Table 4.5 Testing programme for Bed Table 5.1 Volume of ... maximum stroke length of 610mm and the following geometry: outer diameter of 35.6mm cone angle of 60o cone base area of 1000mm2 friction sleeve area of 15000mm2 length of 457mm The penetrometer ... is equal to 10% of the diameter of the base of the pile (BS 8004:1986), or the load at which settlement continues to increase without further increment in load A rate of movement of 0.25 mm/hour...
Ngày tải lên: 07/11/2012, 10:44
Statnamic testing of piles in clay 2
... rates of 0.01mm/s and 100mm/s in each bed are compared in Figure 6.5 to 6.9 The ratios of the maximum measured shaft loads of the CRP test at a rate of 100mm/s to that of the CRP test at a rate of ... results of CRP tests at the rate of 0.01mm/s 143 Chapter Testing data and discussions The comparison of some load-settlement curves are shown in Figures 6.10 to 6.24 Combining the results of all ... that of the first three beds only for the first series of tests After the first series of tests the clay bed was subjected to a triaxial consolidation pressure of 400kPa Although two series of...
Ngày tải lên: 07/11/2012, 10:44
KRONE - Guide Book - TESTING - Field Performance Testing of Copper & Permanent Link Chanel
... Performance Testing V10 050111 Page of TO Passive Testing With Hand-Held Field Testers There are currently three levels of hand-held field tester: Level 2e – for testing up to Class D Level – for testing ... This requirement only applies to PL testing Channel testing still uses the Vendor’s patch cords, which are to be left in situ after testing The configuration of the Permanent Link and Channel is ... Performance Testing of Permanent Links and Channels Testing of telecommunications Permanent Links and Channels to determine performance...
Ngày tải lên: 26/10/2013, 19:15
PERFORMANCE TESTING OF COPPER PERMANENT LINKS AND CHANNEL
... Performance Testing V10 050111 Page of TO Passive Testing With Hand-Held Field Testers There are currently three levels of hand-held field tester: Level 2e – for testing up to Class D Level – for testing ... This requirement only applies to PL testing Channel testing still uses the Vendor’s patch cords, which are to be left in situ after testing The configuration of the Permanent Link and Channel is ... Performance Testing of Permanent Links and Channels Testing of telecommunications Permanent Links and Channels to determine performance...
Ngày tải lên: 27/10/2013, 17:15
Tài liệu ADC KRONE - Guide - FO - Field Performance Testing of Fiber Link - ISO 11801 ppt
... to Method C of TIA/EIA 526-14-A OF Testing ADC KRONE Requirements V7_1&3T Dr2Page of 12 1-Test Cord Method of Reference Setting = Cl 9.1.2 of ISO/IEC 14763-3 Ed2 Similar to Method of IEC 61280-4-1 ... during the early stages of testing to ensure you are getting the results you expect Take appropriate corrective action before further testing if the results are unexpected OF Testing ADC KRONE Requirements ... Method of Reference Setting (Eg SC on tester and SC on both ends of Link) OF Testing ADC KRONE Requirements V7_1&3T Dr2Page of 12 Use of Mandrels or Coils (for both & 1-Test Cord Methods) For MMF,...
Ngày tải lên: 10/12/2013, 02:15
Tài liệu FIELD PERFORMANCE TESTING OF COPPER PERMANENT LINKS AND CHANNEL Class D, Class E, Class EA pdf
... Performance Testing of Permanent Links and Channels There are distinct areas of cable testing; Certification, Qualification and Verification Certification is the most rigorous of all cable testing ... Performance Testing V15 060508 Page of 11 Passive Testing With Hand-Held Field Testers There are currently three levels of hand-held field tester: Level 2e – for testing up to Class D Level – for testing ... This requirement only applies to PL testing Channel testing still uses the Vendor’s patch cords, which are to be left in place after testing The configuration of the Permanent Link and Channel...
Ngày tải lên: 12/12/2013, 12:15
Tài liệu ADC KRONE - Guide - Performance Testing of Optical Fiber Link doc
Ngày tải lên: 20/12/2013, 22:15
Tài liệu PERFORMANCE TESTING OF OPTICAL FIBRE LINKS pptx
... to Method C of TIA/EIA 526-14-A OF Testing ADC KRONE Requirements V7_1&3T Dr2Page of 12 1-Test Cord Method of Reference Setting = Cl 9.1.2 of ISO/IEC 14763-3 Ed2 Similar to Method of IEC 61280-4-1 ... during the early stages of testing to ensure you are getting the results you expect Take appropriate corrective action before further testing if the results are unexpected OF Testing ADC KRONE Requirements ... Method of Reference Setting (Eg SC on tester and SC on both ends of Link) OF Testing ADC KRONE Requirements V7_1&3T Dr2Page of 12 Use of Mandrels or Coils (for both & 1-Test Cord Methods) For MMF,...
Ngày tải lên: 22/12/2013, 12:15
Tài liệu KRONE - Guide - TESTING - Field Performance Testing of Copper & Permanent Link Chanel pdf
... Performance Testing V10 050111 Page of TO Passive Testing With Hand-Held Field Testers There are currently three levels of hand-held field tester: Level 2e – for testing up to Class D Level – for testing ... This requirement only applies to PL testing Channel testing still uses the Vendor’s patch cords, which are to be left in situ after testing The configuration of the Permanent Link and Channel is ... Performance Testing of Permanent Links and Channels Testing of telecommunications Permanent Links and Channels to determine performance...
Ngày tải lên: 24/01/2014, 03:20
Tài liệu KRONE - Guide - TESTING - Field Performance Testing of Copper & Permanent Link Chanel (1) ppt
... Structured cabling deployment of CCTV is preferred by IT departments, who are increasingly tasked with the responsibility of managing such systems and who have knowledge of structured cabling technology ... pairs of a UTP cable, thus reducing the cable requirement Savings can be realised in lower labour and material costs, smaller conduits, fewer cable pulls, common media topology and easier retrofits ... HIGHBAND products are an ideal solution Whilst HIGHBAND might seem to be a premium offering, compared to the cost of a coax based solution, a HIGHBAND Category solution would be more cost effective...
Ngày tải lên: 24/01/2014, 03:20
Tài liệu STUDIES OF AMERICAN FUNGI, MUSHROOMS, EDIBLE, POISONOUS, ETC ppt
... rupture of veil, showing tendency to double annulus on the stem Portions of the veil also dripping from margin of pileus (Natural size.)] =The Color of the Gills.= The color of the gills of the ... objects of nature worthy of observation, if it succeeds in aiding those who are seeking information of the edible kinds, and stimulates some students to undertake the advancement of our knowledge of ... the Fleshy Fungi, Chapter XVIII 229 Uses of Mushrooms, Fungi in the Arts, Chapter XX 204 208 Discomycetes, Chapter XVII 171 231 234 Cultivation of Mushrooms, 237 The Cave Culture of Mushrooms...
Ngày tải lên: 13/02/2014, 12:20
Tài liệu Antimicrobial Susceptibility Testing Protocols ppt
... Antimicrobial Susceptibility Testing .139 Darcie E Roe-Carpenter Chapter Antifungal Susceptibility Testing of Yeasts .173 Ana Espinel-Ingroff and Emilia Cantón Chapter 10 Antifungal Susceptibility ... Cantón Chapter 10 Antifungal Susceptibility Testing of Filamentous Fungi .209 Ana Espinel-Ingroff and Emilia Cantón Chapter 11 Susceptibility Testing of Mycobacteria 243 Barbara A Brown-Elliott, ... the importance of accurate susceptibility testing The clinical microbiology laboratory is often a sentinel for detection of drug-resistant microorganisms Timely notification of susceptibility...
Ngày tải lên: 16/02/2014, 00:20
Ecotoxicological Testing of Marine and Freshwater Ecosystems Emerging Techniques, Trends, and Strategies pot
... Tiered testing approaches Tiered testing refers to a structured, hierarchical procedure for determining data needs relative to decision-making that consists of a series of tiers (levels or steps) of ... Ecotoxicological testing of marine and freshwater ecosystems can be disposed of in an unrestricted fashion (no treatment of the material) in open water as opposed to in some type of confined disposal ... requires grams of sediment compared to an ITW assay that requires liters of sediment When considering the number of samples to be collected, a better analysis of the areal extent of toxicity generally...
Ngày tải lên: 06/03/2014, 18:21
as 2207 1994 non destructive testing ultrasonic testing of
... a distance of 2.5T* from each side of the toe of the weld and over a distance of 2.5T* from each side of the toe of the weld and over a distance of 2.5T* from each side of the toe of the weld ... of discontinuities * † ‡ § UMA-1 and 2, or and 4, over a distance of 2.5T* from each side of the toe of the weld 5† UMA-2 and 2, or and 4, over a distance of 2.5T* from each side of the toe of ... assessment of test results (n) The date and place of test (o) The identification number of test (p) Identification of testing personnel 4.3 TEST REPORT (a) The name of the laboratory or testing...
Ngày tải lên: 12/03/2014, 18:02