www.adc.com • +1-952-938-8080 • 1-800-366-3891
343
Circuit-Switched Telephony Solutions
Homeworx
™
Host Digital Terminal (GR-303) 344
Homeworx
™
Digital Network Interface Unit 348
Homeworx
™
Clocking and Timing Slot Interchange Unit 350
Homeworx
™
Coax Master Unit 352
Homeworx
™
Shelf Control Unit 354
Homeworx
™
Protection Switch and Test Unit 356
Homeworx
™
Power Supply Unit 358
Home Integrated Services Unit 360
Multidwelling Integrated Services Unit 365
www.adc.com • +1-952-938-8080 • 1-800-366-3891
344
6/04 • 1247379
MSO Market Solutions
Homeworx
™
HDT (GR-303)
The Host Digital Terminal (HDT) comprises all of the “common equipment” functions of the voice and data
portion of the ADC Homeworx product line. Normally located in the center office/headend with direct
connection to a local digital switch (LDS) or digital network element (DNE).
Features
• Provides point-to-multi-point transport system
• Up to 3072 call reference values (CRVs) per HDT
• Multihosting capacity, up to 4 hosts
• Accommodates 2-28/DS1/Inputs at the network interface
• GR-303 switch interface
• 1024 x 1024 full access, non-blocking DS0 cross-connect capability
• Supports a maximum of 672 DS0 transport capacity over a HFC network
• All active electronic circuits are packaged on field-replaceable plug-in modules, supports a total
of 21 modules
• A stratum 4 equipment node, but shall operate at a lower stratum level (higher frequency accuracy) when
synchronized to a reference input
• 1536 total ISU hardware addresses (512 per CXMU)
www.adc.com • +1-952-938-8080 • 1-800-366-3891
345
6/04 • 1247379
MSO Market Solutions
Homeworx
™
HDT (GR-303)
HFC System Components
The primary components which make up the Homeworx HFC transport system are as follows:
• Host Digital Terminal (HDT): Provides telephony interface between Switching Network and HFC
Transport Network
• Integrated Services Unit (ISU): Provides modem interface to coaxial distribution network and service
interface to customers.
• Network Element Management: Provides primary interface between Homeworx System components
and customer Operations Systems (OSs)
HDT Module Types
Application
HDT Module Type Quantity In Chassis
Digital Network Interface Unit (DNIU) 8 – 7 quad-DS1 modules + 1 protection module
Protection Switch & Test Conversion Unit (PSTU) 1 – no protection since not service-affecting
Clock & Timeslot Interchange Unit (CTSU) 2 – 1 active, 1 standby/protection module
Coax Master Unit (CXMU) 6 – 3 active, 3 standby/protection modules
Shelf Control Unit (SCNU) 2 – 1 active, 1 standby/protection module;
Power Supply Unit (PWRU) 2 – 2 load-sharing modules
AC & RF
RF CATV DROP
TELEPHONY
DROP
TAP
LINE
EXT.
LEG 2 LEG 3 LEG 4
LEG 1
COMBINED RF &
TELEPHONY ON COAX
AC & RF
OPTICAL
NODE
SUBDIVISION
C
H.
U
N
I
T
C
H.
U
N
I
T
C
H.
U
N
I
T
C
H.
U
N
I
T
MISU-16
Optical
XMT/RCV
HDT
CENTRAL OFFICE/HEADEND
TEL/
VID
RX
TEL/
VID
TX
L
H
R
X
R
X
R
X
R
X
T
X
T
X
T
X
T
X
P
S
/
C
M
P
S
/
C
M
C
T
S
U
P
R
O
T
C
T
S
U
M
A
I
N
P
T
S
U
D
N
I
U
P
R
O
T
D
N
I
U
D
N
I
U
D
N
I
U
D
N
I
U
D
N
I
U
D
N
I
U
D
N
I
U
C
X
M
U
P
R
O
T
C
X
M
U
M
A
I
N
C
X
M
U
P
R
O
T
C
X
M
U
M
A
I
N
C
X
M
U
P
R
O
T
C
X
M
U
M
A
I
N
S
C
N
U
P
R
O
T
PWRU
LDS
COT
DCS
50-750 MHz VIDEO
SOURCE AND
5-49 MHz VIDEO CONTROL
INFORMATION RECEIVERS
COMBINED DOWNSTREAM
VIDEO RF 620-774 MHz
UPSTREAM VIDEO
INFORMATION 5-45 MHz
PWRU
S
C
N
U
M
A
I
N
SPLITTER/COMBINER
www.adc.com • +1-952-938-8080 • 1-800-366-3891
346
6/04 • 1247379
MSO Market Solutions
Homeworx
™
HDT (GR-303)
HDT Functions
HDT Physical Characteristics
System Specifications
Host Digital Terminal
The primary function of each HDT module is as follows:
• DNIU: Provides GR-303 interface to the digital network
• PSTU: Provides the switching function for DNIU
• CTSU: Provides the DS0 timeout grooming capability and all system synchronization functions
• CXMU: Provides the modem functionality and RF interface to the HFC transport system
• SCNU: Provides all OAM&P functions in the system
• PWRU: Converts -48 VDC from a central office battery into the required HDT shelf voltage
Physical Characteristics
Dimensions (HxWxD): 13.95" x 21.4" x 12"
Weight: 127 lbs (fully loaded)
Operating Temperature: 41°F to 104°F long term steady state, 23°F to 122°F short term steady state
Power Consumption: 210 watts (fully loaded including protection cards)
Voltage Requirement: -48 VDC ±5
The front of the HDT chassis is covered with a front panel/door which has an opening for a visual system
alarm indicator.
DS1 NETWORK INTERFACE
Maximum Number of DS1 Interfaces:
DS1 Input Frequency:
DS1 Pulse Shape:
Impedance:
Line Build-out:
Synchronization Timing:
DS1 Physical Interface:
DS1 Framing Formats:
Modes of Operation:
Maximum Amount of Hosts:
Protection Switch Time:
Timeslot Interchange:
COAXIAL LINE INTERFACE
RF SPECIFICATIONS
Number of Coaxial Outputs:
Number of Coaxial Inputs:
Impedance:
Maximum Bandwidth per CXMU:
Tunable RF Modem Frequency Range
Downstream:
Upstream:
RF Modem Frequency Step Size:
Downstream:
Upstream:
Number of DS0s per 6 MHz:
28 (672 DS0s)
1.544 Mbps ±130 ppm
per GR-499
100 OHMs
0 - 655 ft
External BITS, Line, Internal
Amphenol (plug)
SLC-96, SF, ESF
GR-303
4
Less than 50 msec on all HDT cards
1024 x 1024 64 Kbps TSI
3 Tx wrk CXMUs, 3 Tx protect CXMUs
3 Rx wrk CXMUs, 3 Rx protect CXMUs
75 OHMs
6 MHz upstream and downstream (240 DS0s)
620-744 MHz
18-42 MHz usable, 5-42 operational
every 2 MHz
every 1 MHz
240
www.adc.com • +1-952-938-8080 • 1-800-366-3891
347
6/04 • 1247379
MSO Market Solutions
Homeworx
™
HDT (GR-303)
Ordering Information
Ordering Information
Catalog Number
HDT-SHLF35 – B12
HDT-SHLF35 – B6
HDT-SHLF35 – F12
HDT-SHLF35 – F6
Description
HDT-Chassis, 12 BNC No SPL/CMB
HDT-Chassis, 6 BNC w/SPL/CMB
HDT-Chassis, 12 F No SPL/CMB
HDT-Chassis, 6 F w/SPL/CMB
For additional information and assistance in system configuration, please contact ADC.
www.adc.com • +1-952-938-8080 • 1-800-366-3891
348
6/04 • 1247379
MSO Market Solutions
The digital network interface unit (DNIU) provides the GR-303 interface to the digital network and DSX-1
termination.
Features
• Each DNIU plug-in unit provides termination for 4DS1 network lines
• The DNIU can also interface to a digital network element (DNE), such as a channel bank or DS1
cross-connect system to deliver non-switched services
• Six LEDs on the front of the DNIU: (Fail, Active, LPBK-A, LPBK-B, LPBK-C, LPBK-D)
• 7 working and 1 protect cards per HDT (GR-303)
• 2-28 DS1 Inputs at the network interface
• 672 DS0s per HDT
• Protection switching time less than 50 msec on all HDT cards
• G.706 DS1 framing formats
• GR-909, DS1 pulse shape
• 3072 call reference values (CRVs) per HDT
Homeworx
™
DNIU
Digital Network Interface Unit
www.adc.com • +1-952-938-8080 • 1-800-366-3891
349
6/04 • 1247379
MSO Market Solutions
Homeworx
™
DNIU
Digital Network Interface Unit
Ordering Information
Ordering Information
Catalog Number
HDT-DNIU01
Description
Digital Network Interface Unit
For additional information and assistance in system configuration, please contact ADC.
Specifications
PHYSICAL
Weight:
Dimensions (HxWxD):
HDT Mounting Reference:
POWER
-48 VDC Power Consumption:
INTERFACE
DS1 Interface
Capacity:
Compatibility:
Cable Length:
Cable Connector Type:
ENVIRONMENTAL
(HDT Chassis, Fully Loaded)
Heat Dissipation:
Temperature Range
Operating (Normal):
Operating (Short Term):
Storage:
Humidity Range
(Non-Condensing)
Operating:
Storage:
Flammability Rating:
1 lbs (.45 kg)
9.50" x .062" x 9.50"
Plug-in card to the HDT-DNIU labeled slots
5 watts per unit (maximum)
28 DS1 lines per HDT
GR-303
450 ft maximum
50 pin (GR-303)
140 BTU/hour, maximum
32°F to 95°F (0°C to 35°C)
32°F to 120°F (0°C to 50°C)
40°F to 158°F (40°C to 70°C)
20% to 80%
5% to 95%
UL 94 V-1 or better
www.adc.com • +1-952-938-8080 • 1-800-366-3891
350
6/04 • 1247379
MSO Market Solutions
Homeworx
™
CTSU
Clocking and Time Slot Interchange Unit
The CTSU plug-in unit provides the clocking and timeslot interchange functions for the HDT. One CTSU
provides the clocking functions required for normal system operation. A second CTSU can also be installed
and used as a back-up unit in case the first unit should fail. There are two LEDs on the front of the CTSU.
Features
• Maximum 2 cards per HDT
• All clock sources in the HDT are redundant to protect the network against single-point failure
• Provides physical control of all telephony operations
• Terminating point for all LE GR-303/US communications channel messaging
www.adc.com • +1-952-938-8080 • 1-800-366-3891
351
6/04 • 1247379
MSO Market Solutions
Ordering Information
Ordering Information
Catalog Number
HDT-CTSU02
Description
CTSU Clock/Time Slot Unit (GR-303)
For additional information and assistance in system configuration, please contact ADC.
Specifications
PHYSICAL
Weight:
Dimensions (HxWxD):
HDT Mounting Reference:
POWER
-48 VDC Power Consumption:
ENVIRONMENTAL
(HDT Chassis, Fully Loaded)
Heat Dissipation:
Temperature Range
Operating (Normal):
Operating (Short Term):
Storage:
Humidity Range
(Non-Condensing)
Operating:
Storage:
Flammability Rating:
1 lbs (.45 kg)
9.50" x .062" x 9.50"
Plug-in card to the HDT-CTSU labeled slots
6 watts per unit (maximum)
140 BTU/hour, maximum
32°F to 95°F (0°C to 35°C)
32°F to 120°F (0°C to 50°C)
40°F to 158°F (40°C to 70°C)
20% to 80%
5% to 95%
UL 94 V-1 or better
Homeworx
™
CTSU
Clocking and Time Slot Interchange Unit
www.adc.com • +1-952-938-8080 • 1-800-366-3891
352
6/04 • 1247379
MSO Market Solutions
Homeworx
™
CXMU
Coax Master Unit
The CXMU provides the modem functionality and RF interface to the HFC transport system. It delivers
unmatched bandwidth efficiency, trunk group sizing and RF concentration with no additional bandwidth
requirements for channel hopping. Utilizing QAM and OFDM, it provides more revenue per 6 MHz channel
by supporting any level of POTS type service to any subscriber take rate. Superior natural immunity to
impulse noise.
Features
• 240 DS0s per modem (64k channels)
• 3 working 3 protect cards per HDT
• 1 to 1 protection (unique to ADC)
• 1024 customer reference values (CRVs) per CXMU
• 6 MHz channel (5 MHz working, 1 MHz guardband) adjustable in 2 MHz steps
• 512 ISU hardware addresses per CXMU
• 3072 phone numbers (CRVs) per HDT
• Two LEDs located on the front of the CXMU (Active and Fail)
• Multicarrier RF transmission scheme (32-QAM, OFDM)
• Spectral efficiency = 3.26 BITS per Hz
[...]... 1-800-366-3891 353 Homeworx™ SCNU 1247379 MSO Market Solutions Shelf Control Unit Provides all operation, administration, management and provisioning (OAMP) functions in the system Provides monitoring and control functions for the HDT and for other telephony network elements Processes all communications between the network element manager and the telephony network elements Features • A second SCNU can... ISU-TERM-RFTBM01 ISU-TERM-CPETBM01 For assistance with system configuration, please contact ADC 6/04 • 1247379 MSO Market Solutions Description www.adc.com • +1-952-938-8080 • 1-800-366-3891 364 Homeworx™ MSO Market Solutions MISU-16 Multi-dwelling Integrated Services Unit Carrier-class cable telephony is delivered to the customer premise by the MISU-16 Multi-dwelling Integrated Services Unit, providing access... PWRU can support the HDT if the other fails • The HDT chassis requires two battery feeds, one for each PWRU 6/04 • 1247379 MSO Market Solutions Power Supply Unit www.adc.com • +1-952-938-8080 • 1-800-366-3891 358 Homeworx™ PWRU Power Supply Unit Specifications MSO Market Solutions PHYSICAL Weight: Dimensions (HxWxD): HDT Mounting Reference: 2.34lbs (1.06 kg) 4.5" x 2.7" x 9.5" Plug in card to the HDT-PWRU... www.adc.com • +1-952-938-8080 • 1-800-366-3891 360 Homeworx™ HISU Home Integrated Services Unit Ideal for the Residential Market MSO Market Solutions The HISU is ideally suited for the residential market - single-family homes, duplexes, and townhouses needing up to four lines of telephony, plus cable TV as desired The HISU is also an excellent fit to service the needs of the business SOHO market - small office... Upgrade is cost-effective, with minimal impact on technical support • Field-upgradable hot plug-in • No service outage during the upgrade 6/04 • 1247379 MSO Market Solutions The Dual Terminal Block Module (DTBM) terminates two lines of telephony, and is designed for fast, efficient connection of telephone wiring The Protected Dual Terminal Block Module (PDTBM) provides the same function as the DTBM,... shelf • Less than 50 msec protection switching time on all HDT cards 6/04 1247379 MSO Market Solutions Protection Switch and Test Unit • Two LEDs located on front of the card (Fail, Active) www.adc.com • +1-952-938-8080 • 1-800-366-3891 356 Homeworx™ PSTU Protection Switch and Test Unit Specifications MSO Market Solutions PHYSICAL Weight: Dimensions (HxWxD): HDT Mounting Reference: 1 lbs (.45 kg) 9.50"... until the actual subscriber is ready for telephony services • Each QPMU supports up to four POTS lines • Modem is included in the QPMU module 6/04 • 1247379 Features • Modular design enables added capacity as needed www.adc.com • +1-952-938-8080 • 1-800-366-3891 366 Homeworx™ MISU-16 Multi-dwelling Integrated Services Unit Specifications 6/04 • 1247379 MSO Market Solutions CONFIGURATIONS POTS line Increments...Homeworx™ CXMU Coax Master Unit Specifications 1247379 MSO Market Solutions PHYSICAL Weight: Dimensions (HxWxD): HDT Mounting Reference: 2 lbs (1 kg) 9.50" x 1 3/8" x 9.50" Plug-in card to the HDT-CXMU labeled slots POWER -48 VDC Power Consumption: 16 watts per unit... lightning protection • Stability in adverse conditions www.adc.com • +1-952-938-8080 • 1-800-366-3891 361 Homeworx™ HISU Home Integrated Services Unit Dual Terminal Block Module Supports Two Lines of Telephony Features Benefits • Easy to use screw terminals • Quick installation • Multiple wire pairs per terminal • Flexibility for various environments • Multiple gauge wire supported • Accommodating... installation sites Dual POTS Service Module Enables Easy Upgrade to 4 Lines The Dual POTS Service Module (DPSM) enables service providers to deploy two additional lines of telephone service to existing telephony subscribers who have pre-version 3.0 HISUs This module simply plugs into the HISU, and supports a second Dual Terminal Block Module for the two additional lines And with its hot plug-in design, . www.adc.com • +1-952-938-8080 • 1-800-366-3891
343
Circuit-Switched Telephony Solutions
Homeworx
™
Host Digital Terminal (GR-303) 344
Homeworx
™
Digital. load-sharing modules
AC & RF
RF CATV DROP
TELEPHONY
DROP
TAP
LINE
EXT.
LEG 2 LEG 3 LEG 4
LEG 1
COMBINED RF &
TELEPHONY ON COAX
AC & RF
OPTICAL
NODE