www.adc.com • +1-952-938-8080 • 1-800-366-3891
105
Fiber Frames
Introduction 106
Fiber Distribution Frames (FDF) 108
Next Generation Frames (NGF) 132
OMX
™
600 Optical Distribution Frames 151
Off-Frame Splicing Solutions 159
www.adc.com • +1-952-938-8080 • 1-800-366-3891
106
6/04 • 1247379
MSO Market Solutions
Fiber Frames
Introduction
ADC’s Fiber Frame Products
• Provide a centralized point for:
- Termination
- Splice
- Jumper storage
- Passive optical components
• Reduce maintenance costs
• Assure increased subscriber retention
• Prevent fiber congestion
• Physical fiber protection
• Widest choice of frame solutions
Fiber Distribution Frames
• Patented individual angled left/right adapters
eliminate 90 degree bends of optical patch cords
• Clear cable routing paths
• Integrated bend radius protection
• Front and rear access or all front access options
• Quick and easy circuit restoration due to superior
patch cord storage options
• Allows integration of advanced optical components
for capacity/service upgrades and local testing
• Dedicated splice bay options available for off-frame splicing:
ADC recommends this option for greater flexibility, more
cost-effective use of office space and reduced time and cost
for installation and maintenance.
www.adc.com • +1-952-938-8080 • 1-800-366-3891
107
6/04 • 1247379
MSO Market Solutions
Next Generation Frame Products
• Unmatched termination density
• Easy access to connectors and patch cords
within a fully loaded frame
• Clear cable routing paths
• Integrated bend radius protection
• Equipment bays for mounting 19" and 23"
equipment within the NGF lineup
• Integrated jumper storage promotes quick and
easy circuit restoration
• Allows integration of advanced optical components
for capacity/service upgrades and local testing
OMX
™
600 Fiber Frame Solution
• 600mm x 300mm footprint
• 10 module mounting positions
• Total front-access frame
• Allows integration of advanced optical
components for capacity/service upgrades
and local testing
• Shipped with lockable front doors
• Dedicated splice bay options available for
off-frame splicing: ADC recommends this
option for greater flexibility, more cost-effective
use of office space and reduced time and cost
for installation and maintenance.
• OMX Interbay Management Panel
- Off-frame jumper slack storage
- Bend radius protection
- 150mm x 300mm
Fiber Frames
Introduction
www.adc.com • +1-952-938-8080 • 1-800-366-3891
108
6/04 • 1247379
MSO Market Solutions
2
7
8
5
6
4
9
3
Main Components of the Front Load FDF
Front Load fiberframes can be ordered and shipped as a single unit. Simply specify the required
components and ADC will assemble the frame for you. Certain items must be ordered as separate line
items and shipped separately for on-site installation; these items are indicated below.
How To Order a Front Load Frame
Select the desired bay based on height.
Select the desired Front Load modules
Connector Modules: Available in 72 position, 96 position and a 12-pack plug-in configuration. The
72 position module is recommended for most applications. Also available in 144 position using ADC’s
LX.5
®
connectors.
Splice Modules: Accommodate splicing for connector modules. (Remember that splice trays and cable
clamps must be ordered separately.)
Storage Modules: Used to store jumpers when 5" bay spacing is not available (storage modules are not
mandatory when the interbay management panel is used).
Value-Added Modules (VAM): 12 position VAM chassis available for Front Load frames. The Front Load
VAM chassis holds up to 12 single VAM plug-ins.
NOTE: Rear Load modules cannot be installed into a Front Load bay.
Metal doors
Upper and lower half bay doors are recommended to protect fibers on the rear side of the bay.
Interbay management panels (ordered and shipped as separate line items)
The interbay management panel mounts between bays in the same manner as a 5" (12.7 cm) bay spacer.
This panel is optional but is recommended for all applications of the frame. An interbay panel should be
mounted on each side of a fiber frame. For underfloor cabling/raised floor applications an underfloor guard
box is required.
Optional Equipment
Rear fiber storage panel (cross-connect applications only)
Provides cable management and service loop storage of fiber optic patch cords which are typically
routed between an ADC fiber distribution frame (FDF) and the fiber optic terminal (FOT) equipment.
Cannot be used on OSP bays where cable clamps are used.
End guards (ordered and shipped as separate line item).
Splice trays
Each splice module will accept up to (16) 12-position single splice trays or (8) 24-position dual splice
trays. Splice trays must be ordered in addition to the splice module.
Pigtail assemblies
Pigtails can be factory loaded into the bay. Once installed they are 100% tested to ensure their
performance in the field.
Blank panels
As necessary for vacant positions.
Cable clamps (ordered and shipped as separate line item)
One cable clamp is required for each cable brought into the frame.
Communication panels
If a communication panel is desired, it will occupy one module location in the bay.
Fiber optic patch cords.
FiberGuide
®
Fiber Management System.
1
Fiber Distribution Frames
Front Load Frames
10
11
12
13
www.adc.com • +1-952-938-8080 • 1-800-366-3891
109
6/04 • 1247379
MSO Market Solutions
Configuration and Order Form
This page may be copied and used to configure a Front Load frame. The configuration drawing may then
be attached to an order.
Front Load frames include front vertical cable
guides and rear fanning triangles. Interbay
management panels and end guards shown
here are ordered separately. Write catalog
numbers for modules in each location on drawing.
*14" lower troughs are recommended for most
applications; however, other lower troughs are
available. Contact ADC’s Technical Assistance
Center at 1-800-366-3891.
1
5
10
15
20
25
30
35
2.00"
7.00'
25.88"
39
4.50"
8
7
6
5
4
3
2
1
14" HORIZ CABLE TROUGH*
5"
2.5"
Bay ________________________ ________
Modules
Metal doors ________________________ ________
Interbay management panel ________________________ ________
Optional Equipment
Rear fiber storage panel ________________________ ________
End guards ________________________ ________
Splice trays ________________________ ________
Pigtail assemblies ________________________ ________
Blank panels ________________________ ________
Cable clamps ________________________ ________
Communication panel ________________________ ________
Fiber optic patch cords
FiberGuide
®
Fiber Management System
Write catalog number in each
location on drawing above
Order on separate form
Order on separate form
Catalog Number Quantity
Special Configuration Instructions
(Example: install modules at factory, location of pigtails in bay, AC outlet, etc.)
Fiber Distribution Frames
Front Load Frames
www.adc.com • +1-952-938-8080 • 1-800-366-3891
110
6/04 • 1247379
MSO Market Solutions
Front Load Fiber Distribution Frame with 14" (35.56 cm) Trough
2.00"
7.00'
1
5
10
15
20
25
30
35
39
4.50"
25.88"
2.5"
5"
8
7
6
5
4
3
2
1
14" HORIZ CABLE TROUGH
(12) CABLE
TIE BRACKETS
(INCLUDED
WITH FDF)
2"
GUARD
BOX
5.00"
5.00"
7' INTERBAY
MANAGEMENT PANEL
E-501-L139 (2)
7' END GUARD
UEGP-7PW (2)
Front Load FDF
E-501-L88
1
5
10
15
20
25
30
35
39
GROUND LUG WITH #6
COPPER WIRE TINNED
(INCLUDED WITH FDF)
.75" REAR
25.88"
FANNING
TRIANGLES
(INCLUDED
WITH FDF)
Recommended Bay Style
Front View*
• Used in cross-connect or interconnect applications when splicing is done within the frame
• Modules attach to front vertical cable guides
• Only ADC Front Load FDF modules can be used in this bay
• Rear Load modules cannot be installed into a Front Load bay
• Up to eight 8" (20.32 cm) modules can be installed in one Front Load bay
• 7' (2.14 m) bay supports up to 1152 terminations
• Front Load FDFs include unequal flange network type (4.5" guard box) rack, 14" lower horizontal
cable trough, front vertical cable guides, rear fanning triangles, ground wire kit and cable tie brackets
Description
Network Style Unequal Flange Front
Load Bay with 14" (35.56 cm) Trough
7' (2.14 m)
9' (2.76 m)
11.5' (3.52 m)
Catalog Number
1
E-501-L88
E-501-L89
E-501-L90
Ordering Information
Dimensions (HxWxD)
7
'
x 26
"
x 12
"
(2.14 m x 66.04 cm x 30.48 cm)
9'
x 26
"
x 12
"
(2.76 m x 66.04 cm x 30.48 cm)
11.5'
x 26
"
x 12
"
(3.52 m x 66.04 cm x 30.48 cm)
Note: Interbay management panels and end guards are ordered separately.
For existing lineups with 8" or 16" lower cable troughs, call ADC Technical Assistance Center 1-800-366-3891.
Side View
Rear View
1
These products are available in black; add “-B” to the end of the catalog number.
Fiber Distribution Frames
Front Load Frames
*Interbay management panels and end guards shown are for reference only. They are ordered separately.
www.adc.com • +1-952-938-8080 • 1-800-366-3891
111
6/04 • 1247379
MSO Market Solutions
Metal Doors
For Use on Front Load Frames Only
Half Bay Metal Doors
The upper and lower half bay doors completely
cover the rear of the bay. Constructed of metal,
these doors are hinged on both sides and latch
securely, protecting fiber from damage and snags.
8" (20.32 cm) Metal Doors
Individual metal doors are available for the rear of
the bay. Six inch doors are designed for the upper
and lower most positions on the bay. Eight inch
doors are designed for the back of the various
modules within the bay. Constructed of metal,
these doors are hinged on both sides and latch
securely to protect fibers on the rear of the bay.
To provide individual doors for the entire bay, two
6" doors and eight 8" doors are needed.
8" metal doors are standard on Rear Load modules.
Order only for Front Load frames.
TOP HALF
DOOR KIT
BOTTOM
HALF
DOOR KIT
39
35
30
25
20
15
10
5
1
DETAIL A
6" DOOR KIT
DOOR ASSY
SEE DETAIL A
8" DOOR KITS
6" DOOR KIT
39
35
30
25
20
15
10
5
1
FRAME
FANNING
TRIANGLE
Description
Half bay metal doors
Mount into Front Load frames or
WECO hole spaced racks only
Upper half bay
Lower half bay
Individual module metal door
Mount into Front Load frames or
WECO hole spaced racks only
6" top or bottom of bay
8" module
Catalog Number
1
E-501-L157
E-501-L156
E-501-L154
E-501-L155
Ordering Information
Dimensions (HxW)
38" x 23" (96.52 x 58.42 cm)
38" x 23" (96.52 x 58.42 cm)
6" x 23" (15.24 x 58.42 cm)
8" x 23" (20.32 x 58.42 cm)
1
These products are available in black; add “-B” to the end of the catalog number.
Fiber Distribution Frames
Front Load Frame Hardware
www.adc.com • +1-952-938-8080 • 1-800-366-3891
112
6/04 • 1247379
MSO Market Solutions
Fiber Distribution Frames
Front Load Frame Connector Modules
Connector Module — 72, 96 or 144 Termination
• The patented angle retainer allows removal of the adapter from the front of the module without the
use of tools providing access to the connector on the inside of the panel for cleaning
• Fanning strips maintain 1.5" (3.81 cm) bend radius, provide organization, hold fibers in place at
point of entry to the module
• Removable transparent, smoked plastic cover encloses front of module; protects fibers and
connectors from disturbance
• Designation card, identifying each cable, is visible when cover is opened or closed
• An accessory mounting kit is required when installing a Front Load module into a plain, 23" WECO
drilled, unequal flange rack (Non-ADC Front Load Frame)
• 72 position connector modules are numbered 1-36 on the left, 37-72 on the right. 96 position
connector modules are numbered 1-48 on the left, 49-96 on the right. Standard modules are
numbered vertically (see Figure 1). Horizontally numbered connector modules are also available.
20.40"
8.70"
4.91"
8.00"
20.40"
8.70"
4.91"
8.00"
72 Termination Connector Module
Figure 1
96 Termination Connector Module
Figure 2
Number of
Terminations
72
96
144
Ordering Information
Catalog Number
1
E-501-L13
E-501-AL13
E-501-L145
E-501-AL145
E-501-L14
E-501-AL14
E-501-L6
E-501-AL6
E-501-L14-H1
E-501-AL14-H1
E-501-L6-H1
E-501-AL6-H1
E-501-L519
E-501-L591
Singlemode
Adapter Type
SC ultra polish
SC 8° angled polish
FC ultra polish
FC 8° angled polish
SC ultra polish
SC 8° angled polish
FC ultra polish
FC 8° angled polish
SC ultra polish
SC 8° angled polish
FC ultra polish
FC 8° angled polish
LX.5
®
angled polish
LC ultra polish
Numbered
Vertically
Vertically
Vertically
Vertically
Vertically
Vertically
Vertically
Vertically
Horizontally
Horizontally
Horizontally
Horizontally
Vertically
Vertically
1
These products are available in black; add “-B” to the end of the catalog number.
www.adc.com • +1-952-938-8080 • 1-800-366-3891
113
6/04 • 1247379
MSO Market Solutions
The pigtails have an overall protective jacket with 12 color-coded 900µm stranded fibers inside. Each
12-fiber pigtail bundle is numbered making it easy to identify each bundle and route them to the desired
splice tray. They are over 5 meters long so they can be routed from any connector module to the splice
module within the frame.
Positions
72
96
144
Ordering Information
Catalog Number
1
FDF-MOD003
FDF-MOD010
FDF-MOD002
FDF-MOD962
FDF-MOD973
FDF-MOD969
FDF-MOD970
E-501-L581
E-501-L591-SP
Singlemode Connector Type
SC ultra polish
SC 8° angled polish
FC ultra polish
SC ultra polish
SC 8° angled polish
FC ultra polish
FC 8°angled polish
LX.5
®
angled polish
LC ultra polish
1
6
31
36
37
42
56
72
2
3
4
5
6
1
41
48
8
7
49
89
96
56
Figure 1
Figure 2
Fiber Distribution Frames
Front Load Frame Modules with Pigtails
1
These products are available in black; add “-B” to the end of the catalog number.
Other connector and pigtail assembly types are available. Please contact ADC.
Fiber Pigtail Assemblies
Ordering Information
Catalog Number
FPM-07/0-M006.17M-46
FPM-0E/0-M006.17M-46
FPM-02/0-M006.17M-46
FPM-0D/0-M006.17M-46
FPM-0X/0-M006.17M-46
FPM-0K/0-M006.17M-46
Singlemode Connector Type
SC ultra polish
SC 8° angled polish
FC ultra polish
FC 8° angled polish
LX.5
®
angled polish
LC ultra polish
Fiber pigtail assemblies are used within a frame and typically
routed from the backside of a connector module to the splice
module where they are spliced to OSP fibers. ADC offers 5 meter
stranded pigtail assemblies that consist of 12 color-coded 900µm
fibers covered in an overall jacket referred to as a soft wall
bundle. The flexible jacket provides physical protection for the
individual fibers as they are routed from the connector module
to the splice module.
Buffered Fiber
900 micron
PVC Jacket
0.64 mm thick
Soft Wall
(12 Fiber Shown)
www.adc.com • +1-952-938-8080 • 1-800-366-3891
114
6/04 • 1247379
MSO Market Solutions
Front Load Splice Module
Description
Splice module with eight (8) drawers
For Front Load Frames
Cable clamp (0.4" - 1.2" O.D.)
Catalog Number
1
E-501-L33
E-501-L40
Ordering Information
Dimensions (HxWxD)
8.0" x 21.6" x 10.0"
(20.32 x 54.86 x 25.40 cm)
8.00"
21.60"
10.00"
4.94"
Top View
Front Load Splice Module
Loaded with Pigtails
Front Load Splice Module
E-501-L33
• Maximum capacity of 192 splices with stranded fiber, 384 splices with ribbon fiber using ADC’s
new moisture blocking kit for IFC and OSP ribbon fibers.
• Each splice drawer holds two single or one dual splice tray
• Splice trays are available with heat shrink fusion, bare fusion or mechanical (Elastomeric)/mass fusion
• Each drawer designed to handle twenty-four 900 micron pigtails or twelve 3 mm pigtails
• Cover encloses the splice module for protection from normal frame activity
• Pigtail and OSP buffer tubes enter and exit through openings on the back of the module
• Patented slack take-up wheel keeps constant tension on the fiber cable and prevents binding when
drawer is closed
• Cable clamps must be ordered separately and attach to the rear cable management of the frame
Fiber Distribution Frames
Front Load Frame Splice Modules
1
These products are available in black; add “-B” to the end of the catalog number.
[...]... 1x24 1x48 1x48 1x72 1x72 1x96 1x96 1x144 1x144 IFC IFC IFC IFC IFC IFC IFC IFC IFC IFC IFC House Cable* + House Cable* + stranded fiber stranded fiber ribbon fiber stranded fiber ribbon fiber stranded fiber ribbon fiber stranded fiber ribbon fiber stranded fiber ribbon fiber SMF-28 SMF-28 Sumitomo SMF-28 Sumitomo SMF-28 Sumitomo SMF-28 Sumitomo SMF-28 Sumitomo When selecting ADC’s house cable, the... Communication panel _ Fiber optic patch cords Order on separate form FiberGuide® Fiber Management System Order on separate form Bay • Modules Interbay management panel 6/04 1247379 4.50" Optional Equipment Special Configuration Instructions (Example: AC outlet) www.adc.com • +1-952-938-8080 • 1-800-366-3891 116 Fiber Distribution Frames Rear Load Frames Rear Load Fiber Distribution Frame with... 125 Fiber Distribution Frames Front and Rear Load Frame Hardware Rear Fiber Storage Panel • Provides cable management and service loop storage of fiber optic patch cords typically routed between an ADC fiber distribution frame (FDF) and the fiber optic terminal (FOT) equipment • Can be installed in existing lineups • Mounts on either left or right duct area of FDF • Attaches to 7', 9' or 11.5' frames. .. clamp 7 Communication panels If a communication panel is desired, it will occupy one module location in the bay 8 Fiber optic patch cords 9 FiberGuide® Fiber Management System 6/04 4 • Optional Equipment www.adc.com • +1-952-938-8080 • 1-800-366-3891 115 Fiber Distribution Frames Rear Load Frames Configuration and Order Form This page may be copied and used to configure a Rear Load frame The configuration... 864 Fiber Terminations Conventional Frame: 648 Fiber Terminations LGX Style High Density: 1152 Fiber Terminations Horizontal Trough Space 30" 5" Lower Maximum number of terminations allowed in a frame lineup before exceeding 2" pileup* 10,488 1,1247379 10" (5"Upper and Lower) 3,680 2 mm Jumpers FMDF: 1728 Fiber Terminations Conventional Frame: 648 Fiber Terminations LGX Style High Density: 1152 Fiber. .. FC angled polish LX.5® angled polish X (144 only) LC ultra polish K (144 only) 6 D 0 7 L 2 Q X Cable Exit Direction 4 U IFC Type Singlemode † 7 ZB 72 fiber stranded ZC 96 fiber stranded ZD 144 fiber stranded KA EG FJ 72 fiber ribbon 96 fiber ribbon 144 fiber ribbon Connector #2 Singlemode Upward Downward K No connector/ stub end SC ultra polish SC angled polish FC ultra polish FC angled polish LX.5®.. .Fiber Distribution Frames Rear Load Frames How To Order A Rear Load Frame When fiber products are ordered with a factory terminated intrafacility fiber cable (IFC), they must be ordered as individual line items and shipped separately from the bay Other modules specified can... shrink fusion Mechanical (elastomeric) Mass Fusion Catalog Number * Used with 8 fiber soft-wall bundled pigtail assembly, maximum 32 fibers per drawer Other splice types are available Please contact ADC 6/04 • 1247379 MSO Market Solutions Splice Trays www.adc.com • +1-952-938-8080 • 1-800-366-3891 121 Fiber Distribution Frames Front and Rear Load Frame Hardware Rack Installation Kits 0.78 (2) ON 23"... 1728 (864) Frame Capacity (SLIM) 864 (432) * SC and FC 144 blocks are compatible with all existing 30" wide NGF frames and with 30" wide Zone 4 rated frames NGF purchased after November 1, 2001 www.adc.com • +1-952-938-8080 • 1-800-366-3891 133 Next Generation Frames MSO Market Solutions Fiber Main Distributing Frame (FMDF) The FMDF is the cornerstone of the NGF product line This innovative frame has... NGF-F3MDF7A100-30-Z4 - 30" wide F3MDF is recommended for use with the 96 position Fiber Termination Blocks and is required when using 144 position FTBs - Each frame section includes heavy duty floor anchor bolts for concrete floor applications www.adc.com • +1-952-938-8080 • 1-800-366-3891 135 Next Generation FramesFiber Slim Rack The Fiber Slim Rack is designed for lower density applications than the FMDF . 1-800-366-3891
105
Fiber Frames
Introduction 106
Fiber Distribution Frames (FDF) 108
Next Generation Frames (NGF) 132
OMX
™
600 Optical Distribution Frames 151
Off-Frame. module location in the bay.
Fiber optic patch cords.
FiberGuide
®
Fiber Management System.
1
Fiber Distribution Frames
Front Load Frames
10
11
12
13
www.adc.com