1. Trang chủ
  2. » Công Nghệ Thông Tin

Tài liệu Fiber Frames ppt

70 184 0

Đang tải... (xem toàn văn)

Tài liệu hạn chế xem trước, để xem đầy đủ mời bạn chọn Tải xuống

THÔNG TIN TÀI LIỆU

Thông tin cơ bản

Định dạng
Số trang 70
Dung lượng 3,2 MB

Nội dung

www.adc.com • +1-952-938-8080 • 1-800-366-3891 105 Fiber Frames Introduction 106 Fiber Distribution Frames (FDF) 108 Next Generation Frames (NGF) 132 OMX ™ 600 Optical Distribution Frames 151 Off-Frame Splicing Solutions 159 www.adc.com • +1-952-938-8080 • 1-800-366-3891 106 6/04 • 1247379 MSO Market Solutions Fiber Frames Introduction ADC’s Fiber Frame Products • Provide a centralized point for: - Termination - Splice - Jumper storage - Passive optical components • Reduce maintenance costs • Assure increased subscriber retention • Prevent fiber congestion • Physical fiber protection • Widest choice of frame solutions Fiber Distribution Frames • Patented individual angled left/right adapters eliminate 90 degree bends of optical patch cords • Clear cable routing paths • Integrated bend radius protection • Front and rear access or all front access options • Quick and easy circuit restoration due to superior patch cord storage options • Allows integration of advanced optical components for capacity/service upgrades and local testing • Dedicated splice bay options available for off-frame splicing: ADC recommends this option for greater flexibility, more cost-effective use of office space and reduced time and cost for installation and maintenance. www.adc.com • +1-952-938-8080 • 1-800-366-3891 107 6/04 • 1247379 MSO Market Solutions Next Generation Frame Products • Unmatched termination density • Easy access to connectors and patch cords within a fully loaded frame • Clear cable routing paths • Integrated bend radius protection • Equipment bays for mounting 19" and 23" equipment within the NGF lineup • Integrated jumper storage promotes quick and easy circuit restoration • Allows integration of advanced optical components for capacity/service upgrades and local testing OMX ™ 600 Fiber Frame Solution • 600mm x 300mm footprint • 10 module mounting positions • Total front-access frame • Allows integration of advanced optical components for capacity/service upgrades and local testing • Shipped with lockable front doors • Dedicated splice bay options available for off-frame splicing: ADC recommends this option for greater flexibility, more cost-effective use of office space and reduced time and cost for installation and maintenance. • OMX Interbay Management Panel - Off-frame jumper slack storage - Bend radius protection - 150mm x 300mm Fiber Frames Introduction www.adc.com • +1-952-938-8080 • 1-800-366-3891 108 6/04 • 1247379 MSO Market Solutions 2 7 8 5 6 4 9 3 Main Components of the Front Load FDF Front Load fiber frames can be ordered and shipped as a single unit. Simply specify the required components and ADC will assemble the frame for you. Certain items must be ordered as separate line items and shipped separately for on-site installation; these items are indicated below. How To Order a Front Load Frame Select the desired bay based on height. Select the desired Front Load modules Connector Modules: Available in 72 position, 96 position and a 12-pack plug-in configuration. The 72 position module is recommended for most applications. Also available in 144 position using ADC’s LX.5 ® connectors. Splice Modules: Accommodate splicing for connector modules. (Remember that splice trays and cable clamps must be ordered separately.) Storage Modules: Used to store jumpers when 5" bay spacing is not available (storage modules are not mandatory when the interbay management panel is used). Value-Added Modules (VAM): 12 position VAM chassis available for Front Load frames. The Front Load VAM chassis holds up to 12 single VAM plug-ins. NOTE: Rear Load modules cannot be installed into a Front Load bay. Metal doors Upper and lower half bay doors are recommended to protect fibers on the rear side of the bay. Interbay management panels (ordered and shipped as separate line items) The interbay management panel mounts between bays in the same manner as a 5" (12.7 cm) bay spacer. This panel is optional but is recommended for all applications of the frame. An interbay panel should be mounted on each side of a fiber frame. For underfloor cabling/raised floor applications an underfloor guard box is required. Optional Equipment Rear fiber storage panel (cross-connect applications only) Provides cable management and service loop storage of fiber optic patch cords which are typically routed between an ADC fiber distribution frame (FDF) and the fiber optic terminal (FOT) equipment. Cannot be used on OSP bays where cable clamps are used. End guards (ordered and shipped as separate line item). Splice trays Each splice module will accept up to (16) 12-position single splice trays or (8) 24-position dual splice trays. Splice trays must be ordered in addition to the splice module. Pigtail assemblies Pigtails can be factory loaded into the bay. Once installed they are 100% tested to ensure their performance in the field. Blank panels As necessary for vacant positions. Cable clamps (ordered and shipped as separate line item) One cable clamp is required for each cable brought into the frame. Communication panels If a communication panel is desired, it will occupy one module location in the bay. Fiber optic patch cords. FiberGuide ® Fiber Management System. 1 Fiber Distribution Frames Front Load Frames 10 11 12 13 www.adc.com • +1-952-938-8080 • 1-800-366-3891 109 6/04 • 1247379 MSO Market Solutions Configuration and Order Form This page may be copied and used to configure a Front Load frame. The configuration drawing may then be attached to an order. Front Load frames include front vertical cable guides and rear fanning triangles. Interbay management panels and end guards shown here are ordered separately. Write catalog numbers for modules in each location on drawing. *14" lower troughs are recommended for most applications; however, other lower troughs are available. Contact ADC’s Technical Assistance Center at 1-800-366-3891. 1 5 10 15 20 25 30 35 2.00" 7.00' 25.88" 39 4.50" 8 7 6 5 4 3 2 1 14" HORIZ CABLE TROUGH* 5" 2.5" Bay ________________________ ________ Modules Metal doors ________________________ ________ Interbay management panel ________________________ ________ Optional Equipment Rear fiber storage panel ________________________ ________ End guards ________________________ ________ Splice trays ________________________ ________ Pigtail assemblies ________________________ ________ Blank panels ________________________ ________ Cable clamps ________________________ ________ Communication panel ________________________ ________ Fiber optic patch cords FiberGuide ® Fiber Management System Write catalog number in each location on drawing above Order on separate form Order on separate form Catalog Number Quantity Special Configuration Instructions (Example: install modules at factory, location of pigtails in bay, AC outlet, etc.) Fiber Distribution Frames Front Load Frames www.adc.com • +1-952-938-8080 • 1-800-366-3891 110 6/04 • 1247379 MSO Market Solutions Front Load Fiber Distribution Frame with 14" (35.56 cm) Trough 2.00" 7.00' 1 5 10 15 20 25 30 35 39 4.50" 25.88" 2.5" 5" 8 7 6 5 4 3 2 1 14" HORIZ CABLE TROUGH (12) CABLE TIE BRACKETS (INCLUDED WITH FDF) 2" GUARD BOX 5.00" 5.00" 7' INTERBAY MANAGEMENT PANEL E-501-L139 (2) 7' END GUARD UEGP-7PW (2) Front Load FDF E-501-L88 1 5 10 15 20 25 30 35 39 GROUND LUG WITH #6 COPPER WIRE TINNED (INCLUDED WITH FDF) .75" REAR 25.88" FANNING TRIANGLES (INCLUDED WITH FDF) Recommended Bay Style Front View* • Used in cross-connect or interconnect applications when splicing is done within the frame • Modules attach to front vertical cable guides • Only ADC Front Load FDF modules can be used in this bay • Rear Load modules cannot be installed into a Front Load bay • Up to eight 8" (20.32 cm) modules can be installed in one Front Load bay • 7' (2.14 m) bay supports up to 1152 terminations • Front Load FDFs include unequal flange network type (4.5" guard box) rack, 14" lower horizontal cable trough, front vertical cable guides, rear fanning triangles, ground wire kit and cable tie brackets Description Network Style Unequal Flange Front Load Bay with 14" (35.56 cm) Trough 7' (2.14 m) 9' (2.76 m) 11.5' (3.52 m) Catalog Number 1 E-501-L88 E-501-L89 E-501-L90 Ordering Information Dimensions (HxWxD) 7 ' x 26 " x 12 " (2.14 m x 66.04 cm x 30.48 cm) 9' x 26 " x 12 " (2.76 m x 66.04 cm x 30.48 cm) 11.5' x 26 " x 12 " (3.52 m x 66.04 cm x 30.48 cm) Note: Interbay management panels and end guards are ordered separately. For existing lineups with 8" or 16" lower cable troughs, call ADC Technical Assistance Center 1-800-366-3891. Side View Rear View 1 These products are available in black; add “-B” to the end of the catalog number. Fiber Distribution Frames Front Load Frames *Interbay management panels and end guards shown are for reference only. They are ordered separately. www.adc.com • +1-952-938-8080 • 1-800-366-3891 111 6/04 • 1247379 MSO Market Solutions Metal Doors For Use on Front Load Frames Only Half Bay Metal Doors The upper and lower half bay doors completely cover the rear of the bay. Constructed of metal, these doors are hinged on both sides and latch securely, protecting fiber from damage and snags. 8" (20.32 cm) Metal Doors Individual metal doors are available for the rear of the bay. Six inch doors are designed for the upper and lower most positions on the bay. Eight inch doors are designed for the back of the various modules within the bay. Constructed of metal, these doors are hinged on both sides and latch securely to protect fibers on the rear of the bay. To provide individual doors for the entire bay, two 6" doors and eight 8" doors are needed. 8" metal doors are standard on Rear Load modules. Order only for Front Load frames. TOP HALF DOOR KIT BOTTOM HALF DOOR KIT 39 35 30 25 20 15 10 5 1 DETAIL A 6" DOOR KIT DOOR ASSY SEE DETAIL A 8" DOOR KITS 6" DOOR KIT 39 35 30 25 20 15 10 5 1 FRAME FANNING TRIANGLE Description Half bay metal doors Mount into Front Load frames or WECO hole spaced racks only Upper half bay Lower half bay Individual module metal door Mount into Front Load frames or WECO hole spaced racks only 6" top or bottom of bay 8" module Catalog Number 1 E-501-L157 E-501-L156 E-501-L154 E-501-L155 Ordering Information Dimensions (HxW) 38" x 23" (96.52 x 58.42 cm) 38" x 23" (96.52 x 58.42 cm) 6" x 23" (15.24 x 58.42 cm) 8" x 23" (20.32 x 58.42 cm) 1 These products are available in black; add “-B” to the end of the catalog number. Fiber Distribution Frames Front Load Frame Hardware www.adc.com • +1-952-938-8080 • 1-800-366-3891 112 6/04 • 1247379 MSO Market Solutions Fiber Distribution Frames Front Load Frame Connector Modules Connector Module — 72, 96 or 144 Termination • The patented angle retainer allows removal of the adapter from the front of the module without the use of tools providing access to the connector on the inside of the panel for cleaning • Fanning strips maintain 1.5" (3.81 cm) bend radius, provide organization, hold fibers in place at point of entry to the module • Removable transparent, smoked plastic cover encloses front of module; protects fibers and connectors from disturbance • Designation card, identifying each cable, is visible when cover is opened or closed • An accessory mounting kit is required when installing a Front Load module into a plain, 23" WECO drilled, unequal flange rack (Non-ADC Front Load Frame) • 72 position connector modules are numbered 1-36 on the left, 37-72 on the right. 96 position connector modules are numbered 1-48 on the left, 49-96 on the right. Standard modules are numbered vertically (see Figure 1). Horizontally numbered connector modules are also available. 20.40" 8.70" 4.91" 8.00" 20.40" 8.70" 4.91" 8.00" 72 Termination Connector Module Figure 1 96 Termination Connector Module Figure 2 Number of Terminations 72 96 144 Ordering Information Catalog Number 1 E-501-L13 E-501-AL13 E-501-L145 E-501-AL145 E-501-L14 E-501-AL14 E-501-L6 E-501-AL6 E-501-L14-H1 E-501-AL14-H1 E-501-L6-H1 E-501-AL6-H1 E-501-L519 E-501-L591 Singlemode Adapter Type SC ultra polish SC 8° angled polish FC ultra polish FC 8° angled polish SC ultra polish SC 8° angled polish FC ultra polish FC 8° angled polish SC ultra polish SC 8° angled polish FC ultra polish FC 8° angled polish LX.5 ® angled polish LC ultra polish Numbered Vertically Vertically Vertically Vertically Vertically Vertically Vertically Vertically Horizontally Horizontally Horizontally Horizontally Vertically Vertically 1 These products are available in black; add “-B” to the end of the catalog number. www.adc.com • +1-952-938-8080 • 1-800-366-3891 113 6/04 • 1247379 MSO Market Solutions The pigtails have an overall protective jacket with 12 color-coded 900µm stranded fibers inside. Each 12-fiber pigtail bundle is numbered making it easy to identify each bundle and route them to the desired splice tray. They are over 5 meters long so they can be routed from any connector module to the splice module within the frame. Positions 72 96 144 Ordering Information Catalog Number 1 FDF-MOD003 FDF-MOD010 FDF-MOD002 FDF-MOD962 FDF-MOD973 FDF-MOD969 FDF-MOD970 E-501-L581 E-501-L591-SP Singlemode Connector Type SC ultra polish SC 8° angled polish FC ultra polish SC ultra polish SC 8° angled polish FC ultra polish FC 8°angled polish LX.5 ® angled polish LC ultra polish 1 6 31 36 37 42 56 72 2 3 4 5 6 1 41 48 8 7 49 89 96 56 Figure 1 Figure 2 Fiber Distribution Frames Front Load Frame Modules with Pigtails 1 These products are available in black; add “-B” to the end of the catalog number. Other connector and pigtail assembly types are available. Please contact ADC. Fiber Pigtail Assemblies Ordering Information Catalog Number FPM-07/0-M006.17M-46 FPM-0E/0-M006.17M-46 FPM-02/0-M006.17M-46 FPM-0D/0-M006.17M-46 FPM-0X/0-M006.17M-46 FPM-0K/0-M006.17M-46 Singlemode Connector Type SC ultra polish SC 8° angled polish FC ultra polish FC 8° angled polish LX.5 ® angled polish LC ultra polish Fiber pigtail assemblies are used within a frame and typically routed from the backside of a connector module to the splice module where they are spliced to OSP fibers. ADC offers 5 meter stranded pigtail assemblies that consist of 12 color-coded 900µm fibers covered in an overall jacket referred to as a soft wall bundle. The flexible jacket provides physical protection for the individual fibers as they are routed from the connector module to the splice module. Buffered Fiber 900 micron PVC Jacket 0.64 mm thick Soft Wall (12 Fiber Shown) www.adc.com • +1-952-938-8080 • 1-800-366-3891 114 6/04 • 1247379 MSO Market Solutions Front Load Splice Module Description Splice module with eight (8) drawers For Front Load Frames Cable clamp (0.4" - 1.2" O.D.) Catalog Number 1 E-501-L33 E-501-L40 Ordering Information Dimensions (HxWxD) 8.0" x 21.6" x 10.0" (20.32 x 54.86 x 25.40 cm) 8.00" 21.60" 10.00" 4.94" Top View Front Load Splice Module Loaded with Pigtails Front Load Splice Module E-501-L33 • Maximum capacity of 192 splices with stranded fiber, 384 splices with ribbon fiber using ADC’s new moisture blocking kit for IFC and OSP ribbon fibers. • Each splice drawer holds two single or one dual splice tray • Splice trays are available with heat shrink fusion, bare fusion or mechanical (Elastomeric)/mass fusion • Each drawer designed to handle twenty-four 900 micron pigtails or twelve 3 mm pigtails • Cover encloses the splice module for protection from normal frame activity • Pigtail and OSP buffer tubes enter and exit through openings on the back of the module • Patented slack take-up wheel keeps constant tension on the fiber cable and prevents binding when drawer is closed • Cable clamps must be ordered separately and attach to the rear cable management of the frame Fiber Distribution Frames Front Load Frame Splice Modules 1 These products are available in black; add “-B” to the end of the catalog number. [...]... 1x24 1x48 1x48 1x72 1x72 1x96 1x96 1x144 1x144 IFC IFC IFC IFC IFC IFC IFC IFC IFC IFC IFC House Cable* + House Cable* + stranded fiber stranded fiber ribbon fiber stranded fiber ribbon fiber stranded fiber ribbon fiber stranded fiber ribbon fiber stranded fiber ribbon fiber SMF-28 SMF-28 Sumitomo SMF-28 Sumitomo SMF-28 Sumitomo SMF-28 Sumitomo SMF-28 Sumitomo When selecting ADC’s house cable, the... Communication panel _ Fiber optic patch cords Order on separate form FiberGuide® Fiber Management System Order on separate form Bay • Modules Interbay management panel 6/04 1247379 4.50" Optional Equipment Special Configuration Instructions (Example: AC outlet) www.adc.com • +1-952-938-8080 • 1-800-366-3891 116 Fiber Distribution Frames Rear Load Frames Rear Load Fiber Distribution Frame with... 125 Fiber Distribution Frames Front and Rear Load Frame Hardware Rear Fiber Storage Panel • Provides cable management and service loop storage of fiber optic patch cords typically routed between an ADC fiber distribution frame (FDF) and the fiber optic terminal (FOT) equipment • Can be installed in existing lineups • Mounts on either left or right duct area of FDF • Attaches to 7', 9' or 11.5' frames. .. clamp 7 Communication panels If a communication panel is desired, it will occupy one module location in the bay 8 Fiber optic patch cords 9 FiberGuide® Fiber Management System 6/04 4 • Optional Equipment www.adc.com • +1-952-938-8080 • 1-800-366-3891 115 Fiber Distribution Frames Rear Load Frames Configuration and Order Form This page may be copied and used to configure a Rear Load frame The configuration... 864 Fiber Terminations Conventional Frame: 648 Fiber Terminations LGX Style High Density: 1152 Fiber Terminations Horizontal Trough Space 30" 5" Lower Maximum number of terminations allowed in a frame lineup before exceeding 2" pileup* 10,488 1,1247379 10" (5"Upper and Lower) 3,680 2 mm Jumpers FMDF: 1728 Fiber Terminations Conventional Frame: 648 Fiber Terminations LGX Style High Density: 1152 Fiber. .. FC angled polish LX.5® angled polish X (144 only) LC ultra polish K (144 only) 6 D 0 7 L 2 Q X Cable Exit Direction 4 U IFC Type Singlemode † 7 ZB 72 fiber stranded ZC 96 fiber stranded ZD 144 fiber stranded KA EG FJ 72 fiber ribbon 96 fiber ribbon 144 fiber ribbon Connector #2 Singlemode Upward Downward K No connector/ stub end SC ultra polish SC angled polish FC ultra polish FC angled polish LX.5®.. .Fiber Distribution Frames Rear Load Frames How To Order A Rear Load Frame When fiber products are ordered with a factory terminated intrafacility fiber cable (IFC), they must be ordered as individual line items and shipped separately from the bay Other modules specified can... shrink fusion Mechanical (elastomeric) Mass Fusion Catalog Number * Used with 8 fiber soft-wall bundled pigtail assembly, maximum 32 fibers per drawer Other splice types are available Please contact ADC 6/04 • 1247379 MSO Market Solutions Splice Trays www.adc.com • +1-952-938-8080 • 1-800-366-3891 121 Fiber Distribution Frames Front and Rear Load Frame Hardware Rack Installation Kits 0.78 (2) ON 23"... 1728 (864) Frame Capacity (SLIM) 864 (432) * SC and FC 144 blocks are compatible with all existing 30" wide NGF frames and with 30" wide Zone 4 rated frames NGF purchased after November 1, 2001 www.adc.com • +1-952-938-8080 • 1-800-366-3891 133 Next Generation Frames MSO Market Solutions Fiber Main Distributing Frame (FMDF) The FMDF is the cornerstone of the NGF product line This innovative frame has... NGF-F3MDF7A100-30-Z4 - 30" wide F3MDF is recommended for use with the 96 position Fiber Termination Blocks and is required when using 144 position FTBs - Each frame section includes heavy duty floor anchor bolts for concrete floor applications www.adc.com • +1-952-938-8080 • 1-800-366-3891 135 Next Generation Frames Fiber Slim Rack The Fiber Slim Rack is designed for lower density applications than the FMDF . 1-800-366-3891 105 Fiber Frames Introduction 106 Fiber Distribution Frames (FDF) 108 Next Generation Frames (NGF) 132 OMX ™ 600 Optical Distribution Frames 151 Off-Frame. module location in the bay. Fiber optic patch cords. FiberGuide ® Fiber Management System. 1 Fiber Distribution Frames Front Load Frames 10 11 12 13 www.adc.com

Ngày đăng: 17/01/2014, 11:20

TỪ KHÓA LIÊN QUAN

w