Page 1 of 6 Ducted cable TECHNICALSPECIFICATIONS We would like to comment the technical aspects as follows: Our proposed offer fully complies with ITU-T G.652, IEC, EIA standards, and has the following characteristics: CABLE DESIGN - 2… 96 fibres. - Operating wavelength at 1310 nm and 1550 nm. - Non-metallic central member. - Loose buffer tubes (dual layer design) SZ stranded. - Interstices and buffer fully filled. - Dielectric strength member (non-metallic) - Outer PE jacket. - Suitable as METAL -FREE ducted cable (DU). OPTICAL AND MECHANICAL CHARACTERISTICS OF A SINGLE MODE FIBRE Refractive index profile: step Design: matched cladding Coating diameter: 245 µ m ± 5 µ m Cladding diameter: 125 µ m ± 1 µ m Mode field diameter (1310nm): 9.2 µ m ± 0.4 µ m Mode field diameter (1550nm): 10.5 µ m ± 1 µ m Mode field concentricity error: ≤ 0.5 µ m Cladding non circularity: ≤ 1% Effective group index of refraction N eff (1310nm): 1.4675 Effective group index of refraction N eff (1550nm): 1.4681 Numerical aperture: 0.13 Cut off wavelength of cabled fibre: ≤ 1250 nm Attenuation at 1310nm (nominal): 0.34 dB/km Attenuation at 1550nm (nominal): 0.19 dB/km Dispersion in the 1285 to 1330nm window: ≤ 3.5 ps/nm x km Dispersion at 1550nm: ≤ 18 ps/nm x km Zero dispersion wavelength 1301.5 ≤ λ o ≤ 1321.5 nm Zero dispersion slope ≤ 0.092 ps/(nm 2 .Km) Polarization Mode Dispersion (PMD) ≤ 0.2 ps/sqrt(Km) Fibre Curling length ≥ 4m Page 2 of 6 CORE MATERIAL The core of the fibre optic, with a higher refractive index compared to the cladding, is made of SiO 2 (Silicon dioxide) doped with GeO 2 (Germanium dioxide). CLADDING MATERIAL The cladding of the fibre optic is made of SiO 2 (Silicon dioxide). TYPE OF PRIMARY COATING The primary coating is made of an UV-curable acrylate. It is applied in two layers, each of a different Young’s modulus. The inner layer is somewhat softer than the outer one. This coating protects the fibre against microbending losses and against abrasion. Fibre color coding: Fibre 1 blue Fibre 7 red Fibre 2 orange Fibre 8 black Fibre 3 green Fibre 9 yellow Fibre 4 brown Fibre 10 violet Fibre 5 grey Fibre 11 pink Fibre 6 white Fibre 12 aqua DIMENSION OF PRIMARY COATING The dimension of the primary coating is 250 µ m ± 15 µ m. MECHANICAL CHARACTERISTICS OF THE PRIMARY COATING The primary coating is easily strippable by means of a mechanical stripping tool. No chemicals are required. MECHANICAL CHARACTERISTICS OF THE FIBRE Proof test stress: 8N for 1 second; strain: 1% Breaking strength of the fibre: ≥ 150 N/mm 2 Page 3 of 6 BUFFER TUBE TECHNIQUE In the loose buffer tube technique the primary coated fibre is accommodated in a secondary coating, called buffer tube. The buffer tube may contain one or more fibres; the fibres are loosely laying in the tube, statistically in the center of the tube. Due to stranding of the buffers an overlength is produced. (The overlength depends on stranding radius, tube diameter and lay length). That means if a tensile force is applied to the cable, an elongation in a wide range will not result in fibre strain and no attenuation increase is observed. The loose buffer technique is also coping best to temperature induced contractions or dilatations of the cable. The structure is as well a good protection against transverse compression. As a result the whole cable construction is, within a wide range, insensitive to external influences. REVERSE LAY (SZ) STRANDING The elements (loose buffer tubes and if necessary filling elements) are stranded around a central member according to the reverse lay method, which means, that the direction of stranding reverses after a predetermined number of revolutions. At the reverse point the elements are laying parallel to the axis of the cable. A binder is wound around the elements in order to retain them in the proper position. Page 4 of 6 MANUFACTURING OF A DUCTED FIBRE OPTIC CABLE Around a FRP (Fibre Reinforced Plastic) central member, buffer tubes and if necessary filling elements are stranded to form the core of the cable. The central member serving mainly as antibuckling element will be overcoated with a PE jacket if required, to obtain the correct stranding radius. The buffer tubes contain up to 12 fibres and are filled with a paraffine oil based filling compound. Color coding buffer tube 1 blue buffer tube 5 grey buffer tube 2 orange buffer tube 6 white buffer tube 3 green buffer tube 7 red buffer tube 4 brown buffer tube 8 black As well the interstices of the core are filled with a filling compound in order to block any possible water ingress. Aramid yarns are then stranded around the optical module to provide the required tensile strength. Finally an outer PE-jacket (approximate thickness 2mm is extruded). Please refer to the cross sectional drawing which we enclose. MARKING The marking of durable quality, is printed on the cable at regular interval of one meter length. The type of legend marking on the cable is as follows: Manufacturer’s Name. Part number. Cable type Number of Fibres. Date of manufacturing. Metering mark Page 5 of 6 DELIVERY LENGTH Nominal length of ducted cable in each drum is 1Km ± 10% or multiple (2,3,4,5,6,7,8) unless clearly specified at time of ordering. The wooden drum is non-returnable and will be marked with arrows to indicate the direction of rotation. Each drum will have a reel label with the following information: Drum No Batch No Type of cable No of fibres Cable length Inner end marking Outer end marking Gross weight Year/Month of manufacture TECHNICAL CHARACTERISTICS: Cable type: Fibre count 2-30 32-48 50-96 Diameter approx. [ mm ] 11.3 13.3 14.1 Weight approx. [ kg/km ] 96 137 144 Min. bending radius - during installation - installed [ mm ] [ mm ] 250 220 300 270 310 280 Tensile strength - short term (during installation) - long term (installed) [ N ] [ N ] 2700 1300 2700 1300 2700 1300 Compressive stress/crush (Attenuation increase fully reversible) [ N/10cm ] 2000 2000 2000 Impact resistance (E=3Nm, r = 300mm) [ impacts ] (Attenuation increase fully reversible) 30 30 30 Operating temperature range [ o C ] -30 70 -30 70 -30 70 Installation temperature range [ o C ] -5 50 -5 50 -5 50 Page 6 of 6 Outer PE jacket nom. thickness 2mm Filling element Dielectric strength member Interstices fully filled Dielectric central member Buffer tube, filled with 6 singlemode fibres. Outer diameter approx.: 11.3 mm Weight approx.: 96kg/km DUCTED CABLE . Page 1 of 6 Ducted cable TECHNICAL SPECIFICATIONS We would like to comment the technical aspects as follows: Our proposed offer. Inner end marking Outer end marking Gross weight Year/Month of manufacture TECHNICAL CHARACTERISTICS: Cable type: Fibre count 2-30 32-48 50-96 Diameter