Next Generation Frame High Density Fiber Solutions

12 308 0
Next Generation Frame High Density Fiber Solutions

Đang tải... (xem toàn văn)

Tài liệu hạn chế xem trước, để xem đầy đủ mời bạn chọn Tải xuống

Thông tin tài liệu

Fiber Main Distribution Frame 219 Fiber Termination Blocks (FTBs) 220 Fiber Combination Blocks (FCBs) 224 Sliding Adapter Packs 226 Value-Added Module System 227 Accessories 228 • 3/06 www.adc.com • +1-952-938-8080 • 1-800-366-3891 217 Next Generation Frame – High Density Fiber Solutions Introduction 218 102094AE TrueNet® Structured Cabling Next Generation Frame High Density Fiber Solutions Next Generation Frame Introduction Frames Fiber Termination Blocks (FTB) Fiber Termination Blocks (FTBs) are available with SC adapters in block configurations of 96- and 144-positions, and with LC adapters in 144- and 192-positions FTBs utilize sliding adapter packs to gain easy access to both the front and rear connectors There is also a block configuration available to accommodate Mini Value-Added Modules (Mini-VAMs) for applications requiring splitters or WDMs FTBs can be ordered with adapters only or with factory terminated IFC or outside plant cable Fiber Combination Blocks (FCB) Fiber Combination Blocks (FCBs) provide termination and on-frame splicing capabilities, all in one block They are available with SC adapters in block configurations of 96- or 144-positions, or with LC adapters in 144- or 192-positions Features and Benefits Ample Trough Space Reduces jumper pile-up and congestion - Reduces maintenance time due to easy removal and tracing of jumpers - Minimizes risk of microbends or damage to fiber Built-in Jumper Storage Panel Minimizes number of required jumper lengths Maintains fiber bend radius Simplifies frame installation - Saves money by reducing the number of different jumper lengths that have to be kept in inventory - Minimizes risk of microbends or damage to fiber Enclosed system ensures easy cable access without fiber cross-over points ã 102094AE TrueNetđ Structured Cabling ADC’s Next Generation Frame product line is designed to fit a variety of termination, splice, and storage applications This frame is designed with an emphasis on superior cable management and ease of use, including features such as ample trough space for cable and jumpers, easy access to connectors, and storage for jumpers The frame sections are shipped from the factory fully equipped with all cable management hardware including a built-in jumper storage panel 3/06 Next Generation Frame – High Density Fiber Solutions ADC developed its innovative Next Generation Frame (NGF) for high-fiber count applications At 2304 terminations in a single frame, its unique, user-friendly design and superior cable management provide enterprise customers an optimum solution to handle applications with high fiber counts such as data centers Traditionally offered in putty white, the NGF now comes in a black color www.adc.com • +1-952-938-8080 • Sliding Adapter Packs Promotes high density Provides easy access to connectors - Saves valuable floor space - Reduces time required for operations and maintenance Intelligent Cable Routing System No fiber cross-over points Multiple vertical troughways - Reduces maintenance time due to easier removal and tracing of jumpers and minimizes fiber “weaving” Bend Radius Protection at Every Turn - NGF provides complete bend radius at every turn to ensure network performance and reliability 1-800-366-3891 218 Next Generation Frame The FMDF is the cornerstone of the NGF product line This innovative frame has six 5-inch horizontal troughs for a total of 30 inches of horizontal trough space This abundant trough space minimizes fiber pile up and congestion leading to easier jumper traceability and removal The frame has twelve Fiber Termination Block (FTB) mounting positions equally divided between vertical columns on the left and right sides of the frame as shown in the figure below The frame is available in 30-inch wide version painted textured black The 30-inch wide frame provides additional vertical trough space for the highest termination density applications The built-in jumper storage panel will store up to 3.5 7' meters (12 feet) of jumper slack Right Vertical Horizontal Trough (6) 7' FTB Mounting Position (12) 7' 30" 19" Front ISO View Ordering Information 30" 24" Front View Side View 19" 30" Description Maximum Termination Capacity Dimensions (HxWxD) Catalog Number 24" 30" FMDF frame section Color: Black 7' x 30" x 24" (2.14m x 76.2cm x 61cm) 19" 1728 (SC)/2304 (LC) NGFB-MDF7A100-30 Each frame section includes heavy duty floor anchor bolts for concrete floor applications 24" www.adc.com • +1-952-938-8080 • 1-800-366-3891 219 Next Generation Frame – High Density Fiber Solutions Left Vertical Jumper Storage Panel 3/06 • 102094AE TrueNet® Structured Cabling Fiber Main Distributing Frame (FMDF) Next Generation Frame TrueNetđ Structured Cabling 102094AE ã 3/06 Next Generation Frame – High Density Fiber Solutions Fiber Termination Blocks (FTB) – Unterminated (Adapter Only) FTBs without fiber can be ordered fully loaded with adapters Before ordering, determine the block orientation and cable exit direction Unterminated FTBs may be ordered with a “left” orientation (mounts on the left side of the frame) or a “right” orientation (mounts on the right side of the frame) The cable exit direction will be either “upward”* (cables terminated to the rear side of the block exit up toward the top of the frame) or “downward” (cables terminated to the rear side of the block exit down toward the bottom of the frame) All blocks with adapters only are configured to terminate single or dual jumpers on the rear of the block If a multifiber breakout style cable (i.e., OSP/IFC) is to be terminated to the rear of the block, a separate clamping kit and replacement rear storage area kit is required (see next page) FTBs cannot be ordered with a combination of singlemode and multimode adapters If this combination is desired, ADC recommends purchasing a fully loaded adapter only termination block, and separate sliding adapter packs to customize the block on-site 144-Position Right Upward FTB Shown Catalog Number NGFB-TB Block Style 1 SC LC Block Orientation L R Left Right SC Style Blocks C M Cable Exit Direction 96 144 LC Style Blocks M Q Adapter Type Singlemode OR U D K Adapter Type Multimode SC ultra polish LC ultra polish Upward Downward OR T C P 144 192 SC ST® SC aqua, zirconia sleeve1 LC aqua, zirconia sleeve1 LC When deploying Laser Optimized Fiber, ADC automatically includes color coded high quality adapters with zirconia alignment sleeves with its factory terminated blocks to maximize lifetime performance of the system ADC recommends the same practice for customers terminating their fiber in the field See following page for definition of variables www.adc.com • +1-952-938-8080 • 1-800-366-3891 220 Next Generation Frame Fiber Termination Blocks (FTB) Configuration Information Block Style General adapter type required in the FTB Block Configuration Maximum number of terminations that the FTB will accommodate when fully loaded Block Orientation Vertical column of the frame the FTB is to be mounted on Cable Exit Direction Direction the equipment jumpers or OSP cable will exit from the FTB Adapter Type Specific adapter type required in the FTB Cable Clamping/Block Conversion Kits Adapter-only blocks are configured to accommodate single fiber jumpers or multifiber breakout cables If loading a preterminated intrafacility (IFC) cable or a preterminated OSP cable is desired, additional hardware will be required Block conversion kits are available to convert adapter only blocks to blocks that will accept preterminated IFC or OSP style cables The conversion kits contain the cable management hardware, brackets and cable clamps required to convert the block The kit required will depend on the block style originally purchased Protective Cover Fanout Bracket 72-Position Block Loaded with Jumpers 72-Position Block Loaded with Multifiber Breakout Cable 72-Position Block with Clamping Kit Ordering Information • 102094AE Cable Clamp 3/06 Description Catalog Number Block style originally purchased 96- or 144-position left up blocks 96- or 144-position right up blocks 96- or 144-position left down blocks 96- or 144-position right down blocks NGFB-ACCRCMSLU NGFB-ACCRCMSRU NGFB-ACCRCMSLD NGFB-ACCRCMSRD Rear Cable Management Tray for 144 Block Conversion Kit www.adc.com • +1-952-938-8080 • 1-800-366-3891 221 Next Generation Frame – High Density Fiber Solutions TrueNet® Structured Cabling Definition of Variables Next Generation Frame Fiber Termination Blocks (FTB) Preterminated TrueNetđ Structured Cabling 102094AE ã 3/06 Next Generation Frame – High Density Fiber Solutions Configuration Information Preterminated FTBs are available with either indoor or outdoor rated cable in ribbon or stranded configurations All blocks are 100% factory tested to guarantee continuity and reliable connections Preterminated FTBs make installation quick and easy, reducing labor costs Before ordering, determine the block orientation and cable exit direction Preterminated FTBs may be ordered with a “left” orientation (mounts on the left side of the frame) or a “right” orientation (mounts on the right side of the frame) The cable exit direction will be either “upward” (cables terminated to the rear side of the block exit up toward the top of the frame) or “downward” (cables terminated to the rear side of the block exit down toward the bottom of the frame) Preterminated Fiber Termination Blocks Arrive from the Factory with Either IFC or OSP Cables Fiber Cable Easily Uncoils During Installation Fiber Termination Block Ships Inside the Drum IFC Cables Loaded into FTB Definition of Variables Block Style General adapter type required in the FTB Block Configuration Maximum number of terminations that the FTB will accommodate when fully loaded Block Orientation Vertical column of the frame the FTB is to be mounted on Cable Exit Direction Direction the equipment jumpers or OSP cable will exit from the FTB Adapter/Connector #1 Specific adapter/connector type required in the FTB Refers to the adapter/connector type at the FTB Connector #2 Specific connector type required at the cable end opposite the FTB Cable Type Type of cable to be terminated to the FTB Cable Length Required length of the cable terminated to the FTB Ordering information follows on next page www.adc.com • +1-952-938-8080 • 1-800-366-3891 222 Next Generation Frame Fiber Termination Blocks (FTB) – Preterminated FTBs Catalog Number NGFB-TB Cable Length XXX Length in meters Adapter Type Singlemode SC LC SC Style Blocks 96 144 C M P T 144 192 C Block Orientation Left Right L R ZB 72-fiber stranded Adapter/Connector #1 Multimode OR M Q IFC Type Singlemode † SC ultra polish LC ultra polish OR LC Style Blocks K IFC Type Multimode (62.5/125 riser) † VM 72-fiber stranded WM 96-fiber stranded 144-fiber stranded FZ SC LC SC aqua (zirconia sleeve)1 LC aqua (zirconia sleeve)1 OR D Upward Downward OR Connector #2 Singlemode K No connector/stub end SC ultra polish SC ultra polish, zirconia sleeve LC ultra polish Connector #2 Multimode 102094AE P T C OR OR No connector/stub end SC LC SC aqua (zirconia sleeve) LC aqua (zirconia sleeve) OR IFC Type Multimode (50/125 riser) † WB 72-fiber stranded WC 96-fiber stranded VZ 144-fiber stranded IFC Type Multimode (50/125 laser optimized to 300m riser) † WF 72-fiber stranded WE 96-fiber stranded WG 144-fiber stranded Indoor/Outdoor Dry Loose Tube Cable (50/125 plenum) † PR 72-fiber stranded 96-fiber stranded PL PS 144-fiber stranded OSP Cable Type Singlemode † ADC recommends the use of aqua multimode connectors for designation of 10 Gigabit applications VT VW EN FL FM 72-fiber stranded dielectric 96-fiber ribbon dielectric 96-fiber stranded dielectric 144-fiber stranded dielectric 144-fiber ribbon dielectric † Other cable types are available upon request Please contact your ADC representative • 3/06 OR Cable Exit Direction U ZC 96-fiber stranded ZD 144-fiber stranded Next Generation Frame – High Density Fiber Solutions TrueNet® Structured Cabling Block Style See previous page for definition of variables www.adc.com • +1-952-938-8080 • 1-800-366-3891 223 Next Generation Frame Fiber Combination Blocks (FCB) TrueNet® Structured Cabling 102094AE Fiber Combination Blocks provide a place to terminate pigtails and splice IFC/OSP cables on the frame The blocks are available with SC adapters in block configurations of 96- or 144-position or with LC adapters in configurations of 144- or 192-positions The block is available with factory wired pigtails for easy installation Splice trays are shipped with the block if ordered with pigtails; otherwise trays must be ordered separately The block is shipped with a cable clamp for OSP/IFC The FCB occupies two mounting positions on a frame section Before ordering, determine the block orientation FCBs may be ordered with a “left” orientation (mounts on the left side of the frame) or a “right” orientation (mounts on the right side of the frame) Ordering information follows on next page Definition of Variables Block Style General adapter type required in the FCB Block Configuration Maximum number of terminations that the FCB will accommodate when fully loaded Block Orientation Vertical column of the frame the FCB is to be mounted on Adapter/Connector Type Specific adapter/connector type required in the FCB Pigtail Type Type of pigtail required Number of Pigtail Assemblies Number of pigtails to be preinstalled in the FCB Splice Chip Type of splice chip required for splice trays • 3/06 Next Generation Frame – High Density Fiber Solutions Configuration Information www.adc.com • +1-952-938-8080 • 1-800-366-3891 224 Next Generation Frame Fiber Combination Blocks (FCB) Catalog Number Adapter Type Singlemode SC Style Blocks C 96 M 144 Pigtail Type SC ultra polish LC ultra polish OR Adapter/Connector Type Multimode OR LC Style Blocks M 144 Q 192 SC LC SC aqua LC aqua P T C Block Orientation L Left R Right K F J No pigtails 12-fiber pigtail 12-fiber stranded maxi-strip 12-fiber ribbon 12-fiber pigtail (50/125) 12-fiber pigtail (50/125 laser optimized to 300m) 12-fiber pigtail (50/125 laser optimized to 550m) Number of Pigtail Assemblies XX Number of assemblies Splice Tray No splice tray Heat shrink fusion Mechanical (Elastomeric) Nortel Q PAK (24 fiber HS fusion)  44 termination block requires the use of either: Mechanical (elastomeric) splice tray when using mass fusion ribbon splicing or Nortel QPAK splice tray when using single fiber heat shrink fusion splicing 192 termination block requires use of ribbon splicing or the Mechanical (elastomeric) splice tray 192 termination block not available for stranded fiber splicing 2 ADC recommends the use of aqua multimode connectors for designation of 10 Gigabit applications 3 Splice Trays For Fiber Combination Block For use when splice trays are not included with block at time of order Catalog Number FST - DRS - 3/06 Splice Tray Type Number of Splices 12 24 12 splices 24 splices 00 HS MT NT Empty tray* Heat shrink fusion Mechanical (Elastomeric) Nortel QPAK *Maximum size of chip allowed in empty tray: 0.3"H x 2.5"W x 3.6"L www.adc.com • +1-952-938-8080 • 1-800-366-3891 225 Next Generation Frame – High Density Fiber Solutions Block Style 1 SC LC ã 102094AE TrueNetđ Structured Cabling NGFB-CB Next Generation Frame Sliding Adapter Packs Sliding adapter packs house groups of fiber optic adapters and are mounted in Fiber Termination Blocks to provide easy access to connectors Sliding Adapter Packs are available with SC and LC adapters The adapters come in packs of two, four, six and eight depending on the adapter type and the desired termination density See table below for configuration guidelines TrueNet® Structured Cabling 102094AE Block Configuration Adapter Pack Configuration Adapter Type SC 96-Position 96-Position SC 144-Position (block code 'M') SC, LC 192-Position (block code 'Q') LC Pack/6 Pack/4 Pack/6 Pack/4 Pack Pack Pack Pack Adapter Pack Option F (shown below) J (not shown below) K (not shown below) J (not shown below) Option F (E-2000 shown) Catalog Number NGF- SAP 00 Adapter Type Singlemode K Adapter Pack Option* F J K SC ultra polish LC ultra polish Adapter Type Multimode P T C • 3/06 Next Generation Frame – High Density Fiber Solutions Sliding Adapter Pack Configuration Guidelines OR pack/6 pack pack/4 pack pack/6 pack (all block code "M" blocks) SC LC (144 and 192 only) Aqua SC (zirconia sleeve) Aqua LC (zirconia sleeve) ADC recommends the use of aqua multimode connectors for designation of 10 Gigabit applications 1 www.adc.com • +1-952-938-8080 • 1-800-366-3891 226 Next Generation Frame The NGF VAM chassis is interchangeable with termination, splice, and storage modules Each chassis accommodates up to twelve Mini-VAM modules Features: • Enclosed plug-in modules Optical components are protected from physical and environmental damage • Flexible platform Modules can be created for new applications quickly and easily to meet customer requirements • Monitor and/or test Enables providers to troubleshoot networks without forcing disruption of service • Custom configurations Custom splitter configurations available upon request NGF VAM Chassis Catalog Number NGFB - TB Block Style SC/LC D Cable Exit Direction (Rear) U Upward D Downward Block Orientation L Left R Right 3/06 Please contact ADC for VAM ordering information www.adc.com • +1-952-938-8080 • 1-800-366-3891 227 Next Generation Frame – High Density Fiber Solutions ADC’s Next Generation Frame (NGF) Value-Added Modules are designed to support emerging circuit requirements This high-density fiber frame solution provides unlimited expansion while optimizing fiber cable management The NGF system uses Mini Value-Added Modules to incorporate optical splitters for circuit monitoring and video distribution Mini Value-Added Modules can also be configured with wavelength division multiplexing capabilities to increase transmission capacity over existing fiber lines Various input and output interface options are available ã 102094AE TrueNetđ Structured Cabling Value-Added Module System Next Generation Frame Accessories Cable Clamp Kits Cable clamp kits are available for securing IFC/OSP cable or equipment (FOT) jumpers on the rear of the FTB Each FTB has three cable clamp mounting positions TrueNet® Structured Cabling Description Catalog Number Cable clamp kit for FOT patch cords (included with fiber termination blocks loaded with adapters only) Cable clamp kit for IFC/OSP cables, dielectric cable without grounding hardware (included with fiber termination blocks with IFC) NGF-ACCCLMP04 NGF-ACCCLMP08 Rack Extenders Rack extenders are used to extend the height of a 7' (2.14m) rack to the appropriate ceiling height so that it can be secured overhead Ordering Information Description Catalog Number Rack extender 30" Wide Frames NGFB-ACCEXT12-30 NGFB-ACCEXT24-30 NGFB-ACCEXT54-30 12" (30.48cm) 24" (60.96cm) 54" (137.16cm) Isolation Pad Description Catalog Number All 30" wide FMDF and equipment bays All 30" wide Zone FMDF and equipment bays All 30" wide front facing FMDF and equipment bays NGF-ACCISOP30X24 NGF-ACCISOP30X24Z4 NGF-ACCISOP30X19 • 102094AE Ordering Information 3/06 Next Generation Frame – High Density Fiber Solutions Ordering Information www.adc.com • +1-952-938-8080 • 1-800-366-3891 228 ... 227 Next Generation Frame – High Density Fiber Solutions ADC’s Next Generation Frame (NGF) Value-Added Modules are designed to support emerging circuit requirements This high- density fiber frame. .. 219 Next Generation Frame – High Density Fiber Solutions Left Vertical Jumper Storage Panel 3/06 ã 102094AE TrueNetđ Structured Cabling Fiber Main Distributing Frame (FMDF) Next Generation Frame. .. splice trays • 3/06 Next Generation Frame – High Density Fiber Solutions Configuration Information www.adc.com • +1-952-938-8080 • 1-800-366-3891 224 Next Generation Frame Fiber Combination Blocks

Ngày đăng: 27/10/2013, 00:15

Từ khóa liên quan

Tài liệu cùng người dùng

Tài liệu liên quan