Tài liệu Next Generation Frame 600 mm Products Table of Contents doc

30 372 0
Tài liệu Next Generation Frame 600 mm Products Table of Contents doc

Đang tải... (xem toàn văn)

Tài liệu hạn chế xem trước, để xem đầy đủ mời bạn chọn Tải xuống

Thông tin tài liệu

Next Generation Frame (NGF) 600 mm Product Family Ordering Guide Next Generation Frame 600 mm Products Table of Contents Frames Fiber Main Distributing Frame (FMDF) Front Facing Fiber Main Distributing Frame (F3MDF) Fiber Slim Rack Blocks Fiber Termination Blocks (FTB) Unterminated Cable Clamping Kit Fiber Termination Blocks Preterminated 7-8 Fiber Combination Blocks (FCB) 9-11 Sliding Adapter Packs 12 Mini Value-Added Modules (Mini VAMs) 13-21 Accessories Fiber Optic Terminal Jumper Storage Bay 22 Equipment Bay 23 End Guard 24 Cable Clamp Kits 24 Rack Installation Kits 24 AC Outlet Kits 24 Ultra Physical Contact Fiber Optic Patch Cords 25-26 Index 27 6/03 • 852 Next Generation Frame 600 mm Products Introduction w w w a d c c o m • + - - - 8 • - 0 - 6 - Next Generation Frame 600 mm Products 852 Next Generation Frame 600 mm Products Introduction Unprecedented growth in the telecommunications industry has driven wide-spread deployment of optical fiber over the past few years As a result, many service providers are finding that their existing fiber frames and troughs are overflowing with large masses of optical fiber patch cords In addition, the rapid deployment of SONET/SDH, fiber in the loop and video initiatives has created the demand for increased termination density at the fiber distributing frame Service providers must build a sound network infrastructure that will provide a solid base for delivering the new and enhanced broadband services promised by the ever-advancing information superhighway What's Next? It's clear that simply adding additional fiber frames to an existing FDF lineup is not the answer, as conventional fiber frames allow only a small number of bays in a lineup before the horizontal trough system becomes unmanageable A more innovative fiber management plan is needed that will provide unlimited expansion as well as alleviate jumper pile-up in the horizontal troughs With the introduction of its Next Generation Frame family of products, ADC offers the innovative solution that service providers have been waiting for Designed specifically to provide higher density while improving fiber cable management, the Next Generation Frame product family allows for virtually unlimited growth Frames ADC's Next Generation Frame product line has fiber frames designed to fit a variety of termination, splice, and storage applications Each frame option is designed with an emphasis on superior cable management and ease of use, including features such as ample trough space for cable and jumpers, easy access to connectors, and storage for jumpers The frame sections are shipped from the factory fully equipped with all cable management hardware including a built-in jumper storage panel Fiber Termination Blocks (FTB) Fiber Termination Blocks (FTBs) are available with SC, FC, ST® and E-2000 adapters in block configurations of 48, 72 or 96 positions Also, 144 position FTBs are available using LX.5® and LC adapters FTBs utilize sliding adapter packs to gain easy access to both the front and rear connectors There is also a block configuration available to accommodate Mini Value-Added Modules (Mini VAMs) for applications requiring splitters or WDMs FTBs can be ordered with or without IFC or outside plant cable Fiber Combination Blocks Blocks (FCB) Fiber Combination Blocks (FCBs) provide termination and on-frame splicing capabilities, all in one block The block occupies two mounting positions on the frame section They are available with SC, FC, ST® and E-2000 adapters in block configurations of 48, 72 or 96 positions Also, 144 position FCBs are available using LX.5® or LC adapters Features and Benefits Ample Trough Space Sliding Adapter Packs Reduces jumper pile-up and congestion - Reduces maintenance time due to easy removal and tracing of jumpers - Minimizes risk of microbends or damage to fiber Promotes high density Provides easy access to connectors - Saves valuable floor space - Reduces time required for operations and maintenance 6/03 • Built-in Jumper Storage Panel Minimizes number of required jumper lengths Maintains fiber bend radius Simplifies frame installation - Saves money by reducing the number of different jumper lengths that have to be kept in inventory - Minimizes risk of microbends or damage to fiber w w w a d c c o m • + - - - 8 Intelligent Cable Routing System No fiber cross-over points Multiple vertical troughways - Reduces maintenance time due to easier removal and tracing of jumpers and minimizes fiber “weaving” • - 0 - 6 - 1 Next Generation Frame 600 mm Products The FMDF is the cornerstone of the NGF product line This innovative frame has six rear horizontal troughs This abundant trough space minimizes fiber pile up and congestion leading to easier jumper traceability and removal The frame has twelve Fiber Termination Block (FTB) mounting positions equally divided between vertical columns on the left and right sides of the frame as shown in the figure below The frame is 600 mm wide x 600 mm deep The built-in jumper storage panel will store up to meters of jumper slack Left Vertical Right Vertical Horizontal Trough (6) Jumper Storage Panel FTB Mounting Position (12) 600 mm Front ISO View 600 mm Front View Side View Ordering Information Description 600 mm FMDF Frame Section Dimensions Catalog Number 2.2 m x 600 mm x 600 mm NGF-ETSIMDF6060 6/03 • 852 Next Generation Frame 600 mm Products Fiber Main Distributing Frame (FMDF) w w w a d c c o m • + - - - 8 • - 0 - 6 - Next Generation Frame 600 mm Products The F3MDF is designed for single-sided access applications and may be mounted up against a wall or back-to-back to save floor space Unlike the FMDF, the more compact F3MDF is equipped with a single 230 mm horizontal trough The F3MDF has twelve FTB mounting positions equally divided between vertical columns on the left and right sides of the frame as shown in the figure below The frame is 600 mm wide x 480 mm deep The built-in jumper storage panel will store up to meters of jumper slack Left Vertical Jumper Storage Panel Right Vertical FTB Mounting Position (12) 2.2 m Horizontal Trough (6) 600 mm Front ISO View 480 mm Front View Side View Ordering Information Description 600 mm F3MDF Frame Section Dimensions Catalog Number 2.2 m x 600 mm x 480 mm NGF-ETSIF3MDF6048 3/03 • 852 Next Generation Frame 600 mm Products Front Facing Fiber Main Distributing Frame (F3MDF) w w w a d c c o m • + - - - 8 • - 0 - 6 - Next Generation Frame 600 mm Products The Fiber Slim Rack is designed for lower density applications than the FMDF or F3MDF It has six FTB mounting positions and is designed for single-sided access applications The Slim Rack is intended for use in a single frame application and should not be used in a multiframe lineup The built-in jumper storage panel will store up to meters of jumper slack When ordering FTBs for the Slim Rack, remember that only left oriented blocks are used on this frame FTB Mounting Position Jumper Storage Panel 2.14 m 480 mm Front ISO View 480 mm Front View Side View Ordering Information Description NGF Fiber Slim Rack Frame Section Dimensions Catalog Number 2.14 m x 480 mm x 480 mm NGF-SLM7A100 3/03 • 852 Next Generation Frame 600 mm Products Fiber Slim Rack w w w a d c c o m • + - - - 8 • - 0 - 6 - Next Generation Frame 600 mm Products Next Generation Frame 600 mm Products Fiber Termination Blocks (FTB) Unterminated FTBs without fiber can be ordered fully loaded with adapters or empty (no adapters), in which case the adapter packs for the block must be ordered separately (see page 12) Before ordering, determine the block orientation and cable exit direction Unterminated FTBs may be ordered with a “left” orientation (mounts on the left side of the frame) or a “right” orientation (mounts on the right side of the frame) The cable exit direction will be either “upward” (cables terminated to the rear side of the block exit up toward the top of the frame) or “downward” (cables terminated to the rear side of the block exit down toward the bottom of the frame) All blocks with adapters only are configured to terminate single or dual jumpers on the rear of the block If a multi-fiber breakout style cable (i.e., OSP/IFC) is to be terminated to the rear of the block, a separate clamping kit is required (see page 6) Catalog Number NGF-TB Block Style Block Orientation 1 SC L FC/ST® E-2000 LX.5®/LC R Left Right Adapter Type Singlemode Cable Exit Direction Block Configuration A 48 U D L Upward Downward B 72 C 96 M 144 (LX.5® or LC only)* Q V N * 144 blocks using style 1, 2, or cannot be used in 26" wide NGF frames X K Adapter Type SC ultra polish (62.5/125) SC ultra polish, Multimode zirconia sleeve SC 8° angled polish OR SC FC ultra polish A FC FC ultra polish, ST® zirconia sleeve Y LX.5® FC 8° angled polish (144 only) ST® ultra polish P LC E-2000 angled polish (144 only) LX.5® ultra polish (144 only) LX.5® angled polish (144 only) LC ultra polish (144 only) Block Style General adapter type required in the FTB Block Configuration Maximum number of terminations that the FTB will accommodate when fully loaded Block Orientation Vertical column of the frame the FTB is to be mounted on Cable Exit Direction Direction the equipment jumpers or OSP cable will exit from the FTB Adapter Type Specific adapter type required in the FTB 6/03 • 852 Definition of Variables w w w a d c c o m • + - - - 8 • - 0 - 6 - Next Generation Frame 600 mm Products Cable Clamping Kit Clamping kit includes: Cable clamp, protective cover and fanout bracket It is required when terminating a multifiber breakout style cable to the rear of the block Protective Cover Fanout Bracket 72 position block loaded with jumpers 72 position block loaded with multifiber breakout cable 72 position block with clamping kit Ordering Information Description Catalog Number Block style originally purchased All 48- and 72-position blocks 96-position blocks with rear cable management as shown above (blocks ordered before June 2002 96- or 144-position Left Up Blocks 96- or 144-position Right Up Blocks 96- or 144-position Left Down Blocks 96- or 144-position Right Down Blocks NGF-ACCOSPKIT02 NGF-ACCOSPKIT01 NGF-ACCRCMSLU NGF-ACCRCMSRU NGF-ACCRCMSLD NGF-ACCRCMSRD Rear Cable Management Tray for 144 Block Conversion Kit 6/03 • 852 Next Generation Frame 600 mm Products Fiber Termination Blocks w w w a d c c o m • + - - - 8 • - 0 - 6 - Next Generation Frame 600 mm Products Preterminated FTBs are available with either indoor or outdoor rated cable in ribbon or stranded configurations All blocks are 100% factory tested to guarantee continuity and reliable connections Preterminated FTBs make installation quick and easy, reducing labor costs Before ordering, determine the block orientation and cable exit direction Preterminated FTBs may be ordered with a “left” orientation (mounts on the left side of the frame) or a “right” orientation (mounts on the right side of the frame) The cable exit direction will be either “upward” (cables terminated to the rear side of the block exit up toward the top of the frame) or “downward” (cables terminated to the rear side of the block exit down toward the bottom of the frame) Preterminated Fiber Termination Blocks arrive from the factory with either IFC or OSP Cables Fiber cable easily uncoils during installation Fiber Termination Block ships inside the drum Fiber Termination Block loaded with multifiber breakout cable Ordering information follows on next page Block Style General adapter type required in the FTB Block Configuration Maximum number of terminations that the FTB will accommodate when fully loaded Block Orientation Vertical column of the frame the FTB is to be mounted on Cable Exit Direction Direction the equipment jumpers or OSP cable will exit from the FTB Adapter/Connector #1 Specific adapter/connector type required in the FTB Refers to the adapter/ connector type at the FTB Connector #2 Specific connector type required at the cable end opposite the FTB Cable Type Type of cable to be terminated to the FTB Cable Length Required length of the cable terminated to the FTB 6/03 852 Definition of Variables • Next Generation Frame 600 mm Products Fiber Termination Blocks (FTB) Preterminated w w w a d c c o m • + - - - 8 • - 0 - 6 - Next Generation Frame 600 mm Products Preterminated FTBs NGF-TB Cable Length XXX Length in Block Style 1 meters Adapter Type Singlemode SC FC/ST® E-2000 LX.5®/LC Block Configuration A B C M L 48 72 96 144 (LX.5® or LC only)** Q V N X Block Orientation L R K Left Right IFC Type Singlemode † ZB SC ultra polish SC ultra polish, zirconia sleeve SC 8° angled polish FC ultra polish FC ultra polish, zirconia sleeve FC 8° angled polish ST® ultra polish E-2000 angled polish LX.5® ultra polish (144 only) LX.5® angled polish (144 only) LC ultra polish (144 only) ZC ZD AA BA CA 2A 7A VA DA FH GA HA MA JA KA EG FJ KB EF FK OR Adapter/Connector #1 Multimode (62.5/125) Cable Exit Direction U Upward D A Y P Downward SC FC ST® LX.5® (144 only) LC (144 only) L Q V N X K No connector/stub end SC ultra polish SC ultra polish, zirconia sleeve SC 8° angled polish FC ultra polish FC ultra polish, zirconia sleeve FC 8° angled polish ST® ultra polish E-2000 angled polish LX.5® ultra polish (144 only) LX.5® angled polish (144 only) LC ultra polish (144 only) • Connector #2 Multimode (62.5/125) 6/03 A Y P 72 fiber stranded 96 fiber stranded 144 fiber stranded 12 fiber stranded 24 fiber stranded 36 fiber stranded 48 fiber stranded 54 fiber stranded 72 fiber stranded 96 fiber stranded 144 fiber stranded 12 fiber ribbon 24 fiber ribbon 36 fiber ribbon 48 fiber ribbon 72 fiber ribbon 96 fiber ribbon 144 fiber ribbon 72 fiber ribbon 96 fiber ribbon 144 fiber ribbon Glass Type House Cable* House Cable* House Cable* Corning Corning Corning Corning Corning Corning Corning Corning Sumitomo Sumitomo Sumitomo Sumitomo Sumitomo Sumitomo Sumitomo Alcatel Alcatel Alcatel OR Connector #2 Singlemode 852 Next Generation Frame 600 mm Products Catalog Number OR IFC Type Multimode (62.5/125) AM 12 fiber stranded BM 24 fiber stranded DM 36 fiber stranded 2M 48 fiber stranded VM 72 fiber stranded WM 96 fiber stranded Glass Type Corning Corning Corning Corning Corning Corning OSP Cable Type Singlemode VP VT VU VW EN FL FM OR 72 fiber ribbon dielectric 72 fiber stranded dielectric 96 fiber ribbon dielectric 96 fiber ribbon dielectric 96 fiber stranded dielectric 144 fiber stranded dielectric 144 fiber ribbon dielectric Glass Type Alcatel Pirelli Alcatel Pirelli Pirelli Pirelli Pirelli †Other cable types are available upon request Please contact your ACD representative No connector/stub end SC FC ST® LX.5® (144 only) LC (144 only) * House cable will use Corning SMF28, Sumitomo, Alcatel or similar singlemode fiber based on current market availability ** 144 blocks using style 1, 2, or cannot be used in 26" wide NGF frames See previous page for definition of variables w w w a d c c o m • + - - - 8 • - 0 - 6 - Next Generation Frames Next Generation Frame 600 mm Products Value-Added Module System Video Splitter Module Ordering Information Catalog Number NGF-V Module Option Input front, output front Input rear, output front Split Ratio 2000 1x2 2100 1x2 2200 1x2 2300 1x2 2350 1x2 2400 1x2 2500 1x2 2600 1x2 2700 1x2 2800 1x2 2900 1x2 2950 1x2 2030 1x2 3900 1x3 4900 1x4 5300 1x5 6000 1x6 Input Connector/Adapter Singlemode 2U FC ultra polish 2A FC angled polish 7U SC ultra polish 7A SC angled polish 4U ST® ultra polish 8A E-2000 angled polish LU LX.5® ultra polish LA LX.5® angled polish KU LC ultra polish 00 Bare fiber or Multimode** 2M FC 62.5/125 2N FC 50/125 9A SC 50/125 9B SC 62.5/125 5F ST® 50/125 5U ST® 62.5/125 LM LX.5® PM LC 00 Bare fiber 7000 1x7 8000 1x8 50/50 55/45 60/40 65/35 66.6/33.3 70/30 75/25 80/20 85/15 90/10 95/5 99/1 50/50 33/33/33 25/25/25/25 20/20/20/20/20 16.6/16.6/16.6 16/6/16.6/16.6 14.3/14.3/14.3/14.3 14.3/14.3/14.3 12.5/12.5/ 12.5 Output Connector/Adapter Singlemode 2U FC ultra polish Multimode** 2A FC angled polish 2M FC 62.5/125 7U SC ultra polish or 2N FC 50/125 7A SC angled polish 9A SC 50/125 4U ST® ultra polish 9B SC 62.5/125 8A E-2000 angled polish 5F ST® 50/125 LU LX.5® ultra polish ® ® 5U ST 62.5/125 LA LX.5 angled polish LM LX.5® KU LC ultra polish PM LC 00 Bare fiber 00 Bare fiber Splitter Type LEAVE Wideband 1310 and BLANK 1550 nm G 1310 nm wavelength flattened J 1550 nm wavelength flattened Output Pigtail Length† (in meters) Example: 00 = No pigtail 01 = meter 10 = 10 meters Input Pigtail Length† (in meters) Example: 00 = No pigtail 01 = meter 10 = 10 meters † Leave 00 for adapter option Number of Splitters A Single splitter B Dual splitter C Triple splitter REAR Input Front, Output Front REAR FRONT FRONT OUT OUT IN • 852 Output Front INPUT 6/03 IN OUT 1xN INPUT OUTPUT OUTPUT **Contact ADC for multimode specifications and available split ratios OUT 1xN Other split ratios are available Call ADC Technical Assistance Center at 1-800-366-3891 OUTPUT OUTPUT OUTPUT OUTPUT INPUT Input Rear, Output Front w w w a d c c o m • Input Front, Output Rear + - - - 8 • - 0 - 6 - 14 Next Generation Frames Singlemode Wideband Optical Splitter Specifications Other splitter configurations are available Please call ADC Technical Assistance Center, 1-800-366-3891 Splitter Number Splitter Type 2000 2100 2200 2300 2350 2400 2500 2600 2700 2800 2900 2950 2030 3900 4900 5300 6000 7000 8000 9000 A110 B111 C112 D113 E114 F115 G116 M132 1x2 1x2 1x2 1x2 1x2 1x2 1x2 1x2 1x2 1x2 1x2 1x2 2x2 1x3 1x4 1x5 1x6 1x7 1x8 1x9 1x10 1x11 1x12 1x13 1x14 1x15 1x16 1x32 Splitter Ratio 50/50 55/45 60/40 65/35 66.6./33.3 70/30 75/25 80/20 85/15 90/10 95/5 99/1 50/50 33/33/33 25/25/25/25 20/20/20/20/20 16.6/16.6/ 16.6 14.3/14.3/ /14.3 12.5/12.5/ 12.5 11.1/11.1/ /11.1 10/10/10 /10 9.1/9.1/ /9.1 8.3/8.3/ /8.3 7.7/7.7/ /7.7 7.14/7.14/ /7.14 6.66/6.66/ /6.66 6.25/6.25/ 6.25 3.13/3.13/ 3.13 Maximum Insertion Loss* 3.7/3.7 3.2/4.1 2.7/4.7 2.3/5.3 2.2/5.5 2.0/6.0 1.6/6.8 1.3/7.8 1.0/9.2 8/11.2 5/14.4 0.3/22.5 3.7/3.7 5.9/5.9/5.9 7.4/7.4/7.4/7.4 8.6/8.6/8.6/8.6/8.6 9.8/9.8/9.8/ /9.8 10.6/10.6/ /10.6 11.3/11.3/ /11.3 11.5/11.5/ /11.5 12.1/12.1/ /12.1 13.1/13.1/ /13.1 13.3/13.3/ /13.3 13.8/13.8/ /13.8 13.8/13.8/ /13.8 14.5/14.5/ /14.5 14.9/14.9/ 14.9 18.5/18.5/ 18/5 Typical Insertion Loss* 3.1/3.1 2.7/3.6 2.3/4.1 2.0/4.7 1.9/5.0 1.7/5.4 1.4/6.2 1.1/7.1 8/8.4 6/10.2 4/13.2 NA/NA 3.1/3.1 5.0/5.0/5.0 6.2/6.2/6.2/6.2 7.3/7.3/7.3/7.3/7.3 8.1/8.1/8.1 /8.1 8.9/8.9/ /8.9 9.5/9.5/ /9.5 9.9/9.9/ /9.9 10.4/10.4/ /10.4 10.9/10.9/ /10.9 11.3/11.3/ /11.3 11.6/11.6/ /11.6 11.8/11.8/ /11.8 12.4/12.4/ /12.4 12.6/12.6/ 12.6 15.8/15.8/ 15.8 * Does not include connector loss See table on the following page or call ADC Technical Assistance Center, 1-800-366-3891 Maximum Insertion Loss Maximum insertion loss is the upper limit of insertion loss for the coupler and applies over the entire wavelength range specified in the bandpass Typical Insertion Loss Typical insertion loss is the expected insertion loss value for the coupler measured at the specified center wavelength (i.e., 1310 nm and/or 1550 nm) 6/03 • 852 Next Generation Frame 600 mm Products Value-Added Module System w w w a d c c o m • + - - - 8 • - 0 - 6 - 15 Next Generation Frames Singlemode Optical Splitter Specifications MATERIAL Fiber: Jacket: Housing: Corning SMF-28 0.900 mm hytrel tube Stainless steel tube OPTICAL Bandpass Wavelength 1: Wavelength 2: Directivity: Reflectance: Polarization Stability: 1260/1360 nm 1430/1580 nm 55 dB minimum < -55 dB dB maximum MECHANICAL Cable Retention: 45 kg (1.0 lb.) maximum for 25 mm and 900 mm fiber, kg (2.2 lbs.) maximum for cabled fiber assemblies 300 cycles; 45 kg (1.0 lb.) maximum load (fiber cable only) 100 cycles; 45 kg (1.0 lb.) maximum load (fiber cable only) 10-55 Hz per FOTP II condition I drops from 1.5 meters All materials used in fabrication of coupler housing meet UL 94, Level V-I requirements Flex: Twist: Vibration: Impact: Flammability: ENVIRONMENTAL Humidity: Thermal Aging: Temperature Cycling: 336 hours, 60°C at 95% relative humidity 336 hours, 85°C 336 hours, -40°C to 85°C Singlemode Optical Connector Specifications INSERTION LOSS (dB) RETURN LOSS (dB) Ultra Polish PC Connectors: 0.3 dB maximum 0.15 dB typical 57 dB minimum Angled Polish Connectors: 0.5 dB maximum 0.2 dB typical 65 dB minimum 6/03 • 852 Next Generation Frame 600 mm Products Value-Added Module System w w w a d c c o m • + - - - 8 • - 0 - 6 - 16 Next Generation Frames 852 Next Generation Frame 600 mm Products Value-Added Module System WDM Module Ordering Information Catalog Number NGF-W Configuration MUX front, DEMUX front MUX rear, DEMUX front Mux Port Connector/Adapter 2U FC ultra polish 2A FC angled polish 4U ST® ultra polish 7U SC ultra polish 7A SC angled polish 8A E-2000 angled polish LU LX.5® ultra polish LA LX.5® angled polish KU LC ultra polish 00 Bare fiber WDM Type (λ , λ ) A Undirectional multiplexer C Undirectional demultiplexer E Bidirectional λ Tx/λ Rx G Bidirectional λ Rx/λ Tx J 45 dB isolation, pass 1310 K 45 dB isolation, pass 1550 L (Dual only) unidirectional multiplexer, undirectional demultiplexer* M (Dual only) bidirectional λ Tx/λ Rx, bidirectional λ Tx/λ Rx Demux Port Connector/Adapter 2U FC ultra polish 2A FC angled polish 4U ST® ultra polish 7U SC ultra polish 7A SC angled polish 8A E-2000 angled polish LU LX.5® ultra polish LA LX.5® angled polish KU LC ultra polish 00 Bare fiber 2 2 * WDM Type "L" includes (1) unidirectional multiplexer (standard isolation) and (1) unidirectional demultiplexer (isolation specified by next character) Mux Port Pigtail Length Length† (in meters) Example: 00 = No pigtail 01 = meter 10 = 10 meters † Leave 00 for adapter option Wavelength A 1310 (λ )/1550(λ ) B 1533 (λ )/1557(λ ) E 1550 (λ )/1625(λ ) F 1310 (λ )/1625(λ ) 2 2 Isolation Standard High Very high In the ordering charts, the abbreviation “mux” references the multiplexed side of the WDM, the side where two optical signals coexist on one fiber The abbreviation “demux” references the demultiplexed side of the WDM, the side where each signal appears on its own fiber Both unidirectional and bidirectional WDMs are available as shown below UNIDIRECTIONAL MULTIPLEXER 1310 • Demux Port Pigtail Length Length† (in meters) Example: 00 = No pigtail 01 = meter 10 = 10 meters Module Configuration A Single B Dual C Triple UNIDIRECTIONAL DEMULTIPLEXER 1310 1550 1310 1550 DEMUX MUX MUX BIDIRECTIONAL TRANSMISSION 1310 DEMUX 1310 1550 6/03 1550 1310 1550 DEMUX MUX 1550 1310 1310 1550 MUX DEMUX 1550 w w w a d c c o m • + - - - 8 • - 0 - 6 - 17 Next Generation Frames WDM Module Mux Front, Demux Front REAR FRONT REAR Demux Demux WDM Mux Rear, Demux Front Mux FRONT WDM Demux Demux Mux 6/03 • 852 Next Generation Frame 600 mm Products Value-Added Module System w w w a d c c o m • + - - - 8 • - 0 - 6 - 18 ... • 852 Next Generation Frame 600 mm Products Introduction w w w a d c c o m • + - - - 8 • - 0 - 6 - Next Generation Frame 600 mm Products 852 Next Generation Frame 600 mm Products. .. 480 mm x 480 mm NGF-SLM7A100 3/03 • 852 Next Generation Frame 600 mm Products Fiber Slim Rack w w w a d c c o m • + - - - 8 • - 0 - 6 - Next Generation Frame 600 mm Products Next Generation Frame. .. minimum 6/03 • 852 Next Generation Frame 600 mm Products Value-Added Module System w w w a d c c o m • + - - - 8 • - 0 - 6 - 16 Next Generation Frames 852 Next Generation Frame 600 mm Products Value-Added

Ngày đăng: 10/12/2013, 17:15

Từ khóa liên quan

Tài liệu cùng người dùng

  • Đang cập nhật ...

Tài liệu liên quan