Subject to availability and technical change without notice Copyright © 2003 MK 0637-0013-15_Krone-U_FTP450_23_Kat.6_e.doc KRONE F/FTP 450/23 F/FTP 450/23 FRNC Cat. 6 Cable Application The KRONE F/FTP 450/23 cable is designed for applications up to 450 MHz and provides transmission performance meeting Category 6 specifications. This cables are low skew products, i.e. the difference in propagation delay between the individual pairs is very low. This is increasingly being requested for Gigabit Ethernet. The suitability of the cable for high-bit-rate transmission systems ensures a high degree of future proofing. Additional features are the slim design and low weight of the cables. Each pair is individually shielded (FTP). The cable thus exceeds the requirements for EN 55022 Class B emission and EN 55024 immunity, enabling networks to be built which are compliant with the standards on electromagnetic compatibility. Characteristics For up to 450 MHz Excellent electrical characteristics Each pair is individually shielded with foil (FTP) Drain wire between foiled pairs Halogenfree version LS0H (Low Smoke Zero Halogen) Flame retardant to IEC 60332-1 and DIN VDE 0472, part 804, test type C Non corrosive to IEC 60754-2 Low smoke to IEC 61034 Print: “KRONE PREMISNET CAT6 F/FTP LSZH FR 4P AWG23 SBC ISO/IEC 11801/ EN50173-1 IEC 60332-1 CAT C“ <week/year> CA KRONE 0637001315 <METERMARKER> + <Charge> Design Type designation Category Diameter conductor Number of pairs Fire rating (MJ/m) Halogen- free Tensile strength for installation [N] Outside-ø [mm] Weight [kg/km] F/FTP 450/23 4P LS0H-1 6 AWG 23 4 0,57 yes 145 7,4 58 * Cable description in compliance to ISO/IEC 11801 (2002) appendix E Simplex (F/FTP 450/23 4P) Cu-conductor AWG 23 Foam/Skin-PE-Insulation Pair foil shield 2 wires stranded foil Sheath zero halogen, flame retardant Drain wire page 2 of 2 Subject to availability and technical change without notice Copyright © 2003 MK 0637-0013-15_Krone-F/FTP 450_23_Kat.6_e.doc KRONE F/FTP 450/23 F/FTP 450/23 FRNC Cat. 6 Cable Electrical Characteristics at 20°C Frequency in MHz 1 10 16 20 31,25 62,5 100 250 450 Attenuation in dB/ 100 m per Standard * 2,1 6,0 7,6 8,5 10,8 15,5 19,9 33,0 - Typical data dB / 100 m 1,9 5,5 7,1 7,8 9,9 14,0 17,7 28,1 38,6 Near-end crosstalk loss in dB per Standard * 66,0 59,3 56,2 54,8 51,9 47,4 44,3 38,3 - Typical data dB / 100 m 100,0 100,0 100,0 100,0 100,0 95,0 93,0 88,0 83,0 PSNEXT in dB/ 100 m per Standard * 64,0 57,3 54,2 52,8 49,9 45,4 42,3 36,3 - Typical data dB / 100 m 98,0 98,0 98,0 98,0 98,0 93,0 91,0 86,0 80,0 ELFEXT in dB/ 100 m per Standard * 66,0 50,0 45,9 44,0 40,1 34,1 30,0 22,0 - Typical data dB / 100 m 93,0 93,0 93,0 93,0 90,0 84,0 81,0 67,0 51,0 PSELFEXT in dB/ 100 m per Standard * 64,0 47,0 43,0 41,0 37,1 31,1 27,0 19,0 - Typical data dB / 100 m 91,0 91,0 91,0 91,0 86,0 82,0 79,0 66,0 50,0 ACR in dB 98,1 94,5 92,9 92,2 90,1 72,0 75,3 59,9 44,4 *) Standard: Requirements on 100 m installed Category 6 cable for Class E cabling links (corresponds to pr EN 50288-5-1) Max. loop resistance: 146 Ohm/km Max. resistance difference: 1% Insulation resistance: > 5000 MOhm x km Impedance Zo at 0,064 MHz: 125 Ohm ± 20% Impedance Zo at 1 - 100 MHz: 100 Ohm ± 15% Impedance Zo at 101 - 250 MHz: 100 Ohm ± 18% Transfer impedance: < 10 mOhm per meter bei 10 MHz Longitudinal conversion loss dB/ref. Length = 1000 m: > 46 dB bei 64 kHz Longitudinal conversion loss dB/ref. Length = 100 m: > 40 dB bei 1 MHz Longitudinal conversion loss dB/ref. Length = 100 m: > 20 dB bei 100 MHz Mutual capacity: 43 pF/m Max. capacitance at 0,001 MHz: 1000 pF/km Propagation velocity > 10 MHz (NVP*c): 0,79 c Propagation delay ≥ 10 MHz: 4,2 ns/m Skew: 4 ns/100m Mechanical Characteristics Wire insulation: Zero halogen foam/skin material Sheath material: FRNC Deployment area: Dry and damp rooms Max. temperature range during installation: 0°C up to +50 °C Max. operating temperature: -20 up to +60°C Min. bend radius for single flexure: 40 mm Min. bend radius during installation or pulling: 60 mm Ordering Information Type designation: F/FTP 450/23 4P FRNC Delivery: 1000 m on one way drum Ordering number 4 pairs: 7053 3 271-55 . Copyright © 2003 MK 063 7-0013-15 _Krone- U_FTP450_23_Kat .6_ e.doc KRONE F/FTP 450/23 F/FTP 450/23 FRNC Cat. 6 Cable Application The KRONE F/FTP 450/23 cable is designed. without notice Copyright © 2003 MK 063 7-0013-15 _Krone- F/FTP 450_23_Kat .6_ e.doc KRONE F/FTP 450/23 F/FTP 450/23 FRNC Cat. 6 Cable Electrical Characteristics

Ngày đăng: 23/10/2013, 00:15

TỪ KHÓA LIÊN QUAN