T10206 DN02 P0BTL 840001 battery charger system

20 94 0
T10206 DN02 P0BTL   840001 battery charger system

Đang tải... (xem toàn văn)

Tài liệu hạn chế xem trước, để xem đầy đủ mời bạn chọn Tải xuống

Thông tin tài liệu

Mô tả về hệ thống Battery charge trong nhà máy nhiệt điện.................................................................................................................................................................................................................................................................................................................................................................................................................................................................

78 79 80 81 82 83 84 85 86 87 88 89 90 °C/cell Client Tag No : Battery Type: Ambient Temp.: No °C/cell No 91 92 93 94 95 96 97 98 99 100 101 102 103 104 105 106 107 108 109 110 111 112 113 114 115 116 117 118 119 120 121 122 123 124 125 126 127 128 129 130 131 132 133 134 135 °C/cell 136 137 138 139 140 141 142 143 144 145 146 147 148 149 150 151 152 153 154 155 156 157 158 159 160 161 162 163 164 165 166 167 168 169 170 171 172 173 174 175 176 177 178 179 180 Page 13 of 20 Rev B BATTERY CHECK LEVEL ACID LIQUID E 720.101 G.096-1GB-1 GUTOR Order No No 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 Charge time: Charge current: L M : H No 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60 61 62 63 64 65 66 67 68 69 70 71 72 73 74 75 76 77 78 79 80 81 82 83 84 85 86 87 88 89 90 Client Tag No : L M H No 91 92 93 94 95 96 97 98 99 100 101 102 103 104 105 106 107 108 109 110 111 112 113 114 115 116 117 118 119 120 121 122 123 124 125 126 127 128 129 130 131 132 133 134 135 Battery Type: Ambient Temp.: L M H No 136 137 138 139 140 141 142 143 144 145 146 147 148 149 150 151 152 153 154 155 156 157 158 159 160 161 162 163 164 165 166 167 168 169 170 171 172 173 174 175 176 177 178 179 180 L M H Page 14 of 20 Rev B BATTERY EQUALIZER CHARGE RECORD E 720.101 G.096-1GB-1 GUTOR Order No : 1110076001-01 Client Tag No Charge time: Hrs Charge current: 2.4 Adc No 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 Volt/cell No 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60 61 62 63 64 65 66 67 68 69 70 71 72 73 74 75 76 77 78 79 80 81 82 83 84 85 86 87 88 89 90 : 08-DCU-04 Type: ALCAD , HC12P Charge voltage: 145.2 V Volt/cell No 91 92 93 94 95 96 97 98 99 100 101 102 103 104 105 106 107 108 109 110 111 112 113 114 115 116 117 118 119 120 121 122 123 124 125 126 127 128 129 130 131 132 133 134 135 Volt/cell No Volt/cell 136 137 138 139 140 141 142 143 144 145 146 147 148 149 150 151 152 153 154 155 156 157 158 159 160 161 162 163 164 165 166 167 168 169 170 171 172 173 174 175 176 177 178 179 180 Page 15 of 20 Rev B BATTERY CHECK LEVEL ACID LIQUID E 720.101 G.096-1GB-1 GUTOR Order No Charge time: Charge current: No 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 L M H : No 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60 61 62 63 64 65 66 67 68 69 70 71 72 73 74 75 76 77 78 79 80 81 82 83 84 85 86 87 88 89 90 Client Tag No : Battery Type: Ambient Temp.: L M H No 91 92 93 94 95 96 97 98 99 100 101 102 103 104 105 106 107 108 109 110 111 112 113 114 115 116 117 118 119 120 121 122 123 124 125 126 127 128 129 130 131 132 133 134 135 L M H No 136 137 138 139 140 141 142 143 144 145 146 147 148 149 150 151 152 153 154 155 156 157 158 159 160 161 162 163 164 165 166 167 168 169 170 171 172 173 174 175 176 177 178 179 180 L M H Page 16 of 20 Rev B BATTERY DISCHARGE RECORD E 720.101 G.096-1GB-1 GUTOR Order No : 1110076001-01 Charge time: 10Hrs Charge current: 2.4Adc No Volt/cell No Volt/cell No 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 91 92 93 94 95 96 97 98 99 100 101 102 103 104 105 106 107 108 109 110 111 112 113 114 115 116 117 118 119 120 121 122 123 124 125 126 127 128 129 130 131 132 133 134 135 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60 61 62 63 64 65 66 67 68 69 70 71 72 73 74 75 76 77 78 79 80 81 82 83 84 85 86 87 88 89 90 Client Tag No : 08-DCU-04 Type: ALCAD , HC12P Charge voltage: 154.2 V Volt/cell No Volt/cell 136 137 138 139 140 141 142 143 144 145 146 147 148 149 150 151 152 153 154 155 156 157 158 159 160 161 162 163 164 165 166 167 168 169 170 171 172 173 174 175 176 177 178 179 180 Page 17 of 20 Rev B DC ALARM TEST E 720.101 G.096-1GB-1 GUTOR Order No : Client Tag No : 1.Alarms Perform lamp test and check that all Led’s illuminate Indication Relay frontpanel Board OK OK Rectifier mains fault Rectifier failure DC Overcurrent Overtemperature Battery discharged DC out of tolerance Main DC fuse blown Battery disconnected Control power fault Fan failure Option Option Option Option Option Option A077: X004 A025: X009 A077: X012 A077: X009 A077: X007 A077: X005 A077: X008 A077: X006 A077: X011 A077: X013 N.A N.A N.A N.A A077: X014 A077: X015 Option Option DC Earth + DC Earth - N.A N.A N.A N.A Common alarm A025: X007 Performed by: GUTOR Print: William Tan Sign: Date: Observe Safety Precautions! Page 18 of 20 Rev B DC FUNCTION TEST E 720.101 G.096-1GB-1 GUTOR Order No : Client Tag No : Functional test for complete system Condition: Complete System is working in normal operation and no alarm is pending Both Rectifier systems are in Normal Operation and load sharing Open Rectifier mains input breaker (Q001) of Rectifier then Rectifier goes to Standby Rectifier in Normal Operation and takes over all the load Open Rectifier main input breaker (Q001) of Rectifier 2, both Rectifier goes to Battery Operation Close Rectifier mains input breaker (Q001) of Rectifier then Rectifier goes back to Normal Operation and take all the load Rectifier goes to Standby Closer Rectifier main input breaker (Q001) of Rectifier both Rectifier goes to Normal Operation and load sharing Reset all the Alarms and clear the alarms log stack Tests performed successfully? Yes No Performed by: GUTOR Print: William Tan Sign: Date: Observe Safety Precautions! Page 19 of 20 Rev B 3.0 ATTACHMENTS Attachment 3.1 Charger Application Attachment 3.2 Schedule commissioning Attachment 3.3 Specification of load bank test Attachment 3.4 Battery test guide Attachment 3.5 Material safety data sheet Attachment 3.6 1120069_Relay-Charger Attachment 3.7 Filling acid Battery Procedure Page 20 of 20 ... Client Tag No : Functional test for complete system Condition: Complete System is working in normal operation and no alarm is pending Both Rectifier systems are in Normal Operation and load sharing... Rectifier mains fault Rectifier failure DC Overcurrent Overtemperature Battery discharged DC out of tolerance Main DC fuse blown Battery disconnected Control power fault Fan failure Option Option... Rev B 3.0 ATTACHMENTS Attachment 3.1 Charger Application Attachment 3.2 Schedule commissioning Attachment 3.3 Specification of load bank test Attachment 3.4 Battery test guide Attachment 3.5 Material

Ngày đăng: 11/02/2019, 09:00

Mục lục

  • 1.0 GENERAL PURPOSE

    • 1.1 INTRODUCTION & COMMISSIONING BOUNDARY

    • 1.2 SCOPE OF COMMISSIONING PACKAGE

    • 1.3 THE SAFETY KNOWLEDGE IN OPERATION

    • 2.0 INSPECTION & TEST ITEM

Tài liệu cùng người dùng

Tài liệu liên quan