76 8600 50115i 8600 smart routers fault management configuration guide

102 207 0
76 8600 50115i 8600 smart routers fault management configuration guide

Đang tải... (xem toàn văn)

Tài liệu hạn chế xem trước, để xem đầy đủ mời bạn chọn Tải xuống

Thông tin tài liệu

8600 Smart Routers Fault Management Configuration Guide 76.8600-50115I 12.05.2015 Document Information Revision History Document No Date Description of Changes 76.8600-50115I 12.05.2015 SP7.0 updates for the following network elements: • 8602 Smart Router • 8609 Smart Router • 8611 Smart Router • 8615 Smart Router • 8630 Smart Router • 8660 Smart Router • 8665 Smart Router Interface types updated in 1.1.1 Fault Source Grouping 76.8600-50115H 29.09.2014 • 8602 Smart Router FP1.1 • 8609 Smart Router and 8611 Smart Router FP2.0 • 8615 Smart Router FP1.0 • 8630 Smart Router and 8660 Smart Router FP5.0 Interface list updated in 1.1.1 Fault Source Grouping 76.8600-50115G 26.05.2014 Updates added for: • 8602 Smart Router FP1.0 • 8609 Smart Router and 8611 Smart Router FP1.3 Clarification on fault severity classification added to 1.1.2 Fault Severity 8600 Smart Routers Fault Management Configuration Guide 76.8600-50115I © 2015 Coriant This manual documents the following network elements: 8602 Smart Router 8605 Smart Router 8607 Smart Router 8609 Smart Router 8611 Smart Router 8615 Smart Router 8620 Smart Router 8630 Smart Router 8660 Smart Router 8665 Smart Router The functionality described in this document for 8615 Smart Router is also applicable to 8615 Smart Router stacked, unless otherwise stated © 2015 Coriant All rights reserved This manual is protected by U.S and international copyright laws, conventions and treaties Your right to use this manual is subject to limitations and restrictions imposed by applicable licenses and copyright laws Unauthorized reproduction, modification, distribution, display or other use of this manual may result in criminal and civil penalties The specifications and information regarding the products in this manual are subject to change without notice All statements, information, and recommendations in this manual are believed to be accurate but are presented without warranty of any kind, express or implied Users must take full responsibility for their application of any products Adobe ® Reader ® are registered trademarks of Adobe Systems Incorporated in the United States and/or other countries 76.8600-50115I © 2015 Coriant 8600 Smart Routers Fault Management Configuration Guide 8600 Smart Routers Fault Management Configuration Guide 76.8600-50115I © 2015 Coriant Document Information Terms and Abbreviations 76.8600-50115I © 2015 Coriant Term Explanation AAL ATM Adaptation Layer ACL Access Control List ADSL Asymmetric Digital Subscriber Line AIS Alarm Indication Signal ARP Address Resolution Protocol ATM Asynchronous Transfer Mode BGP Border Gateway Protocol BMP Broadband Management Protocol A communication protocol which is used between 8600 network elements and 8000 intelligent network manager BSD Berkeley Software Distribution CAM Content Addressable Memory CDC Control and DC Power Card (used in 8630 Smart Router and 8660 Smart Router) CLI Command Line Interface CPU Central Processor Unit CU Control functionality (used in 8615 Smart Router and 8665 Smart Router) DHCP Dynamic Host Configuration Protocol ELC1 Ethernet Line Card (used in 8630 Smart Router and 8660 Smart Router) elink Internal resources used to receive traffic streams ELP Ethernet Link Protection Eq swi Switching unit equipment protection FE Fast Ethernet FP Feature Pack FTN Forwarding equivalence class To Next hop label forwarding entry map (for MPLS) FTP File Transfer Protocol GE Gigabit Ethernet GGSN Gateway GPRS Support Node HW Hardware ICMP Internet Control Message Protocol IF Interface IFC Interface Module Concentrator is a line card baseboard and it can be equipped with one or two IFMs There are three variants available: IFC1-A, IFC1-B and IFC2-B (used in 8630 Smart Router and 8660 Smart Router) IFM Interface Module A specific term of the module which can be placed on the IFC line card or 8620 Smart Router baseboard and which consists of the physical interfaces (used in 8620 Smart Router, 8630 Smart Router and 8660 Smart Router) 8600 Smart Routers Fault Management Configuration Guide Document Information ILM Incoming Label Map (for MPLS) IMA Inverse Multiplexing for ATM IP Internet Protocol Ip iw IP interworking IRB Integrated Routing and Bridging LACP Link Aggregation Control Protocol LAG Ethernet Link Aggregation LCP Link Control Protocol LDP Label Distribution Protocol LED Light-Emitting Diode Line card The line card in the 8600 system consists of an Ethernet Line Card (ELC1), Interface Module Concentrator (IFC) and up to two Interface Modules (IFMs) (used in 8630 Smart Router and 8660 Smart Router) In 8000 Intelligent Network Manager and CLI referred to as unit llink Internal resources used to transmit traffic streams LOF Loss Of Frame LOM Loss Of H4 Multiframe LOP Loss of Pointer LOS Loss of signal LSA Link-State Advertisement LSP Label Switched Path LU Traffic functionality (used in 8615 Smart Router and 8665 Smart Router) LU1 Line unit used in 8665 Smart Router MAC Ethernet Media Access Control MFE Management Fast Ethernet MOC Managed Object Class MPLS Multiprotocol Label Switching MPLS-TP Multiprotocol Label Switching -Transport Profile MTU Maximum Transfer/Transmission Unit NE Network Element Node In CLI refers to an NE NPU Network Processor Unit NTP Network Time Protocol OAM Operation, Administration and Maintenance OSPF Open Shortest Path First POS Packet over SDH PPP Point-to-Point Protocol PPS Pulse-per-Second 8600 Smart Routers Fault Management Configuration Guide 76.8600-50115I © 2015 Coriant Document Information 76.8600-50115I © 2015 Coriant PSN Packet Switch Network PTP Precision Time Protocol RAI Remote Alarm Indication RDI Remote Error Indicator/Indication RFC Request for Comments RSVP-TE Resource Reservation Protocol - Traffic Engineering SDH Synchronous Digital Hierarchy SFP Small Form-Factor Pluggable SLP Service Location Protocol SHDSL Single-Line High-bit-rate Digital Subscriber Line SLM Signal Label Mismatch SNMP Simple Network Management Protocol SSF Server Signal Fail SU1 Switch unit used in 8665 Smart Router SW Software TCP Transmission Control Protocol TIM Trace Identifier Mismatch TTSI Trail Termination Source Identifier Unit In CLI refers to a card VPLS Virtual Private LAN Service VPN Virtual Private Network VRF VPN Routing and Forwarding VRRP Virtual Router Redundancy Protocol 8600 Smart Routers Fault Management Configuration Guide 8600 Smart Routers Fault Management Configuration Guide 76.8600-50115I © 2015 Coriant Table of Contents Table of Contents About This Manual 10 Objectives 10 Audience 10 8600 Smart Routers Technical Documentation 10 Document Conventions 14 Interface Numbering Conventions 14 Documentation Feedback 14 8600 Smart Routers Discontinued Products 15 8600 Network Element Faults 16 1.1 1.2 1.3 76.8600-50115I © 2015 Coriant Overview 16 1.1.1 Fault Source Grouping 17 1.1.2 Fault Severity 20 1.1.3 Service Affected Flag 21 1.1.4 Alarm Type 21 1.1.5 LED 21 1.1.6 Fault Status 21 1.1.7 External Alarm Relays 22 1.1.8 System Message Logging 22 1.1.9 References 22 Configuration Examples 23 Fault Tables 24 8600 Smart Routers Fault Management Configuration Guide About This Manual About This Manual This chapter discusses the objectives and intended audience of this manual, 8600 Smart Routers Fault Management Configuration Guide and consists of the following sections: • Objectives • Audience • Related Documentation • Conventions • Documentation Feedback Objectives This manual provides an overview of the 8600 Smart Routers fault management and instructions on how to configure it using command line interface (CLI) and ASCII textual commands with a router's console or remote terminal (Telnet) Audience This manual is designed for administration personnel for configuring 8600 Smart Routers functions with CLI On the other hand, 8000 Intelligent Network Manager provides access to equal functionality for administration personnel with a graphical user interface It is assumed that you have a basic understanding of networks and network interfaces of different technologies (SDH, Ethernet) 8600 Smart Routers Technical Documentation The document numbering scheme consists of the document ID, indicated by numbers, and the document revision, indicated by a letter The references in the Related Documentation table below are generic and include only the document ID To make sure the references point to the latest available document versions, please refer to the relevant product document program on the Tellabs and Coriant Portal by navigating to www.portal.tellabs.com > Product Documentation & Software > Data Networking > 8600 Smart Routers > Technical Documentation The table below reflects the customer document content planned for SR7.0 GA, and is subject to change Before General Availability of SR7.0, the configuration guides have the status of draft, and they not always describe the full functionality 8600 Smart Routers Fault Management Configuration Guide 10 76.8600-50115I © 2015 Coriant Fault Type Severity, Serv Aff, Led Description Resource Associated ([8660,8630 CDC1 / CDC2 / IFC1 / IFC2 / ELC1] / 8620 / 8602 / 8605 / 8607 / 8609 / 8611 / 8615 / [8665 vCU / LU1 / SU1]) Line loop 0x4 (hex) (dec) Communications alarm Warning, -, Yellow Signal looped back towards line ethrJackMau (FP [-/-/2.10/3.0/4.0] /2.10/1.0/1.2/1.0A/1.0/1.1/1.0/ [-/7.0/-]) pdhE1PPITTPBid (FP [-/-/2.2/3.0/-] /2.2/-/1.0/1.0A/1.0/1.1/-/ [-/-/-]) pdhP12CTPBid (FP [-/-/2.7/3.0/-] /2.7/-/1.0/1.0A/1.0/1.1/-/ [-/-/-]) pdhP12sTTPBid (FP [-/-/2.0/-/-] /2.0/-/-/-/-/-/-/ [-/-/-]) pdhDs1PathCTPBid (FP [-/-/2.7/3.0/-] /2.7/-/1.1/1.0A/1.0/1.1/-/ [-/-/-]) pdhDs3PathCTPBid (FP [-/-/-/-/-] /-/-/1.2/-/-/-/-/ [-/-/-]) sdhSPITTPBid (FP [-/-/1.0/3.0/-] /1.0/-/-/-/-/-/-/ [-/-/-]) sdhStsSPITTPBid (FP [-/-/2.5/3.0/-] /2.5/-/-/-/-/-/-/ [-/-/-]) 8600 Network Element Faults 8600 Smart Routers Fault Management Configuration Guide 88 Fault / Spt 76.8600-50115I © 2015 Coriant 76.8600-50115I © 2015 Coriant Fault Type Severity, Serv Aff, Led Description Resource Associated ([8660,8630 CDC1 / CDC2 / IFC1 / IFC2 / ELC1] / 8620 / 8602 / 8605 / 8607 / 8609 / 8611 / 8615 / [8665 vCU / LU1 / SU1]) Link down 0x5 (hex) (dec) Communications alarm Critical, Service affecting, Red The link is down i.e not operational dslBondPortGroup (FP [-/-/-/-/-] /-/-/-/1.1/-/-/-/ [-/-/-]) ethrJackMau (FP [1.0/4.1/1.0/3.0/4.0] /1.0/1.0/1.0/1.0A/1.0/1.1/1.0/ [-/7.0/-]) ethrLag (FP [3.0/4.1/-/-/-] /-/1.0/-/-/1.2/1.2/7.0/ [7.0/-/-]) ethrLagLink (FP [-/-/-/3.0/5.0] /-/1.0/-/-/1.2/1.2/7.0/ [7.0/-/-]) frrInterface (FP [-/-/2.4/3.0/-] /2.4/-/-/-/-/-/-/ [-/-/-]) frrPvcCtp (FP [-/-/2.4/3.0/-] /2.4/-/-/-/-/-/-/ [-/-/-]) hdlcCiscoHdlcInterface (FP [-/-/2.7/3.0/-] /2.7/-/-/-/-/-/-/ [-/-/-]) pppLcp (FP [-/-/1.0/3.0/-] /1.0/-/1.0 SP/1.0A/1.0/1.1/-/ [-/-/-]) pppBridgingCp (FP [-/-/-/-/-] /-/-/1.4/-/1.0/1.1/-/ [-/-/-]) pppIpCp (FP [-/-/1.0/3.0/-] /1.0/-/1.0 SP/1.0A/1.0/1.1/-/ [-/-/-]) pppMplsCp (FP [-/-/1.0/3.0/-] /1.0/-/1.0 SP/1.0A/1.0/1.1/-/ [-/-/-]) pppOsiNlCp (FP [-/-/3.0/3.0/-] /3.0/-/1.4/1.1/1.0/1.1/-/ [-/-/-]) pppMultilinkGroup (FP [-/-/2.8/3.0/-] /2.8/-/1.0 SP/1.0A/1.0/1.1/-/ [-/-/-]) Los detection hw failure 0x50003 (hex) 327683 (dec) Equipment alarm Warning, -, None Loss of signal detection HW failure Los state can not be detected reliably ethrJackMau (FP [-/-/2.7/3.0/4.0] /2.7/-/-/-/-/-/-/ [-/-/-]) 8600 Network Element Faults 89 8600 Smart Routers Fault Management Configuration Guide Fault / Spt Fault Type Severity, Serv Aff, Led Description Resource Associated ([8660,8630 CDC1 / CDC2 / IFC1 / IFC2 / ELC1] / 8620 / 8602 / 8605 / 8607 / 8609 / 8611 / 8615 / [8665 vCU / LU1 / SU1]) Loss of adaptive timing 0xC001E (hex) 786462 (dec) Quality of service alarm Major, Service affecting, Red Loss of adaptive timing Either converging takes longer than expected or holdover state entered pdhP12CTPBid (FP [-/-/2.10/3.0/-] /2.10/-/1.2/1.0A/1.0/1.1/-/ [-/-/-]) pdhDs1PathCTPBid (FP [-/-/2.10/3.0/-] /2.10/-/-/-/-/-/-/ [-/-/-]) Loss of cell delineation 0x20001 (hex) 131073 (dec) Communications alarm Critical, Service affecting, Red Loss of cell delineation fault This alarm is active when loss of cell delineation is detected in the ingress ATM interface This alarm is not valid for the atmInterface associated to atmImaGroup where cell delineation is monitored individually for each IMA links and is reported as cLIF failure atmInterface (FP [-/-/2.0/3.0/-] /2.0/-/1.0/1.0A/1.0/1.1/-/ [-/-/-]) 8600 Network Element Faults 8600 Smart Routers Fault Management Configuration Guide 90 Fault / Spt 76.8600-50115I © 2015 Coriant 76.8600-50115I © 2015 Coriant Fault Type Severity, Serv Aff, Led Description Resource Associated ([8660,8630 CDC1 / CDC2 / IFC1 / IFC2 / ELC1] / 8620 / 8602 / 8605 / 8607 / 8609 / 8611 / 8615 / [8665 vCU / LU1 / SU1]) Loss of frame 0x6 (hex) (dec) Communications alarm Critical, Service affecting, Red Loss of frame alignment (cLOF) pdhP12sTTPBid (FP [-/-/2.0/3.0/-] /2.0/-/1.0/1.0A/1.0/1.1/-/ [-/-/-]) pdhP12sMonTTPBid (FP [-/-/2.9/3.0/-] /2.9/-/1.1/1.0A/1.0/1.1/-/ [-/-/-]) pdhDs1PathTTPBid (FP [-/-/2.5/3.0/-] /2.5/-/1.1/1.0A/1.0/1.1/-/ [-/-/-]) pdhDs1PathMonTTPBid (FP [-/-/2.9/3.0/-] /2.9/-/1.1/1.0A/1.0/1.1/-/ [-/-/-]) pdhDs3PathTTPBid (FP [-/-/-/-/-] /-/-/1.2/-/-/-/-/ [-/-/-]) sdhRsTTPBid (FP [-/-/1.0/3.0/-] /1.0/-/-/-/-/-/-/ [-/-/-]) sdhSectionTTPBid (FP [-/-/2.5/3.0/-] /2.5/-/-/-/-/-/-/ [-/-/-]) syncSciClockE1 (FP [2.5/4.1/-/-/-] /2.5/-/-/1.0A/1.0/1.1/1.0/ [7.0/-/-]) syncSciClockT1 (FP [2.5/4.1/-/-/-] /2.5/-/-/1.0A/1.0/1.1/1.0/ [7.0/-/-]) Loss of multiframe 0x7 (hex) (dec) Communications alarm Critical, Service affecting, Red The multiframe is lost (cLOM) sdhVc4TTPBid (FP [-/-/2.0/3.0/-] /2.0/-/-/-/-/-/-/ [-/-/-]) 8600 Network Element Faults 91 8600 Smart Routers Fault Management Configuration Guide Fault / Spt Fault Type Severity, Serv Aff, Led Description Resource Associated ([8660,8630 CDC1 / CDC2 / IFC1 / IFC2 / ELC1] / 8620 / 8602 / 8605 / 8607 / 8609 / 8611 / 8615 / [8665 vCU / LU1 / SU1]) Loss of pointer 0x8 (hex) (dec) Communications alarm Critical, Service affecting, Red The sdh/sonet AU/TU pointer is lost (cLOP) sdhAu4CTPBid (FP [-/-/1.0/3.0/-] /1.0/-/-/-/-/-/-/ [-/-/-]) sdhTu12CTPBid (FP [-/-/2.0/3.0/-] /2.0/-/-/-/-/-/-/ [-/-/-]) sdhStsCTPBid (FP [-/-/2.5/3.0/-] /2.5/-/-/-/-/-/-/ [-/-/-]) sdhVt15CTPBid (FP [-/-/2.5/3.0/-] /2.5/-/-/-/-/-/-/ [-/-/-]) Loss of power 0x1F0001 (hex) 2031617 (dec) Communications alarm Critical, Service affecting, Red Loss of power dslShdslLine (FP [-/-/-/-/-] /-/-/-/1.0A/-/-/-/ [-/-/-]) 8600 Network Element Faults 8600 Smart Routers Fault Management Configuration Guide 92 Fault / Spt 76.8600-50115I © 2015 Coriant 76.8600-50115I © 2015 Coriant Fault Type Severity, Serv Aff, Led Description Resource Associated ([8660,8630 CDC1 / CDC2 / IFC1 / IFC2 / ELC1] / 8620 / 8602 / 8605 / 8607 / 8609 / 8611 / 8615 / [8665 vCU / LU1 / SU1]) Loss of signal 0x9 (hex) (dec) Communications alarm Critical, Service affecting, Red Signal is lost Link is out of service or not connected For TDM IF, this is declared when received signal has not had any transitions for a period of time or the signal level is too low or laser is switched off For DSL IF, this means that there is no signal level or line is in startup state, or in idle state (SRU) (cLOS) dslShdslLine (FP [-/-/-/-/-] /-/-/-/1.0A/-/-/-/ [-/-/-]) dslAdslZLine (FP [-/-/-/-/-] /-/-/-/1.1/-/-/-/ [-/-/-]) dslAdslZLine2Bond (FP [-/-/-/-/-] /-/-/-/1.1/-/-/-/ [-/-/-]) ethrJackMau (FP [-/-/4.1/4.1/4.1] /-/1.0/-//1.2/1.2/1.0/ [-/7.0/-]) pdhE1PPITTPBid (FP [-/-/2.2/3.0/-] /2.2/-/1.0/1.0A/1.0/1.1/-/ [-/-/-]) pdhDs1LineTTPBid (FP [-/-/2.5/3.0/-] /2.5/-/1.1/1.0A/1.0/1.1/-/ [-/-/-]) pdhDs3LineTTPBid (FP [-/-/-/-/-] /-/-/1.2/-/-/-/-/ [-/-/-]) sdhSPITTPBid (FP [-/-/1.0/3.0/-] /1.0/-/-/-/-/-/-/ [-/-/-]) sdhStsSPITTPBid (FP [-/-/2.5/3.0/-] /2.5/-/-/-/-/-/-/ [-/-/-]) syncSciClock (FP [1.0/4.1/-/-/-] /1.0/-/1.0/1.0A/1.0/1.1/1.0/ [7.0/-/-]) syncPpsClockInput (FP [-/4.1/-/-/-] /-/-/-/-/1.2/-/1.0/ [-/-/-]) sync1588VirtualSciClock (FP [-/4.1/-/-/-] /-/1.0/1.3/1.1/1.0/1.1/1.0/ [-/-/-]) syncGnssClock (FP [-/-/-/-/-] /-/1.0/-/-/1.3/-/-/ [-/-/-]) 8600 Network Element Faults 93 8600 Smart Routers Fault Management Configuration Guide Fault / Spt 76.8600-50115I © 2015 Coriant Fault Type Severity, Serv Aff, Led Description Resource Associated ([8660,8630 CDC1 / CDC2 / IFC1 / IFC2 / ELC1] / 8620 / 8602 / 8605 / 8607 / 8609 / 8611 / 8615 / [8665 vCU / LU1 / SU1]) Multilink max rx delay exceeded 0xE0005 (hex) 917509 (dec) Communications alarm Major, Service affecting, Yellow Maximum configured delay between links exceeded on Rx side This can be caused by asymmetrical member link delay pppMultilinkLink (FP [-/-/2.11/3.0/-] /2.11/-/1.3/1.1/1.0/1.1/-/ [-/-/-]) Multilink max tx delay exceeded 0xE0003 (hex) 917507 (dec) Communications alarm Major, Service affecting, Yellow Maximum configured delay between links exceeded on Tx side pppMultilinkLink (FP [-/-/2.9/3.0/-] /2.9/-/1.2/1.0A/1.0/1.1/-/ [-/-/-]) Multilink member links down 0xE0001 (hex) 917505 (dec) Communications alarm Major, Service affecting, Yellow One or more member links are operationally down Multilink bundle continues operation with the remaining good links (if any) pppMultilinkGroup (FP [-/-/2.7/3.0/-] /2.7/-/1.0 SP/1.0A/1.0/1.1/-/ [-/-/-]) Multilink member max delay exceeded 0xE0004 (hex) 917508 (dec) Communications alarm Major, Service affecting, Yellow Maximum configured delay between links exceeded in one or more members This fault is emitted if difference action is report only pppMultilinkGroup (FP [-/-/2.10/3.0/-] /2.10/-/1.2/1.0A/1.0/1.1/-/ [-/-/-]) Multilink misconfiguration 0xE0006 (hex) 917510 (dec) Communications alarm Major, Service affecting, Yellow There is a misconfiguration between this end and peer multilink bundle on this link The detection is based on Endpoint Discriminator Option pppMultilinkLink (FP [-/-/2.11/3.0/-] /2.11/-/1.3/1.1/1.0/1.1/-/ [-/-/-]) Operational mode hw conflict 0x5000F (hex) 327695 (dec) Equipment alarm Critical, -, Red Ethernet speed / duplex / auto-negotiation configurations conflict with pluggable Transceiver Module (SFP / XFP) capabilities Either mismatching configurations need to changed or Transceiver Module need to be replaced ethrJackMau (FP [-//4.0/4.0/4.0] /4.0/-/-/-/-/-/1.0/ [-/7.0/-]) Phy lack of bandwidth 0x90001 (hex) 589825 (dec) Communications alarm Critical, Service affecting, Red Module cannot allocate all IF capacity it needs so the actual datarate is limited Please, reallocate bandwidth for modules lpoPhyBandwidthUsage (FP [-/-/3.1/3.1/4.0] /3.1/-/-/-/-/-/-/ [-/-/-]) Pw loss of packets state 0xC0023 (hex) 786467 (dec) Communications alarm Critical, Service affecting, Red Too many missing packets detected compared to expected packet rate pdhP12TunnelPw (FP [-/-/3.1/3.1/-] /3.1/-/1.5/-/1.0/1.1/-/ [-/-/-]) pdhCesoPsnTunnelPw (FP [-/-/3.1/3.1/-] /3.1/-/1.5/-/1.0/1.1/-/ [-/-/-]) 8600 Network Element Faults 8600 Smart Routers Fault Management Configuration Guide 94 Fault / Spt 76.8600-50115I © 2015 Coriant Fault Type Severity, Serv Aff, Led Description Resource Associated ([8660,8630 CDC1 / CDC2 / IFC1 / IFC2 / ELC1] / 8620 / 8602 / 8605 / 8607 / 8609 / 8611 / 8615 / [8665 vCU / LU1 / SU1]) Pw remote defect indicator 0xC0020 (hex) 786464 (dec) Communications alarm Major, -, Yellow The pseudowire remote defect indication received from the far end (R bit) pdhP12TunnelPw (FP [-/-/3.1/3.1/-] /3.1/-/1.5/-/1.0/1.1/-/ [-/-/-]) pdhCesoPsnTunnelPw (FP [-/-/3.1/3.1/-] /3.1/-/1.5/-/1.0/1.1/-/ [-/-/-]) Pw tdm failure 0xC0022 (hex) 786466 (dec) Communications alarm Critical, Service affecting, Red The attachment circuit fault indication received from the far end (via Lbit) pdhP12TunnelPw (FP [-/-/3.1/3.1/-] /3.1/-/1.5/-/1.0/1.1/-/ [-/-/-]) pdhCesoPsnTunnelPw (FP [-/-/3.1/3.1/-] /3.1/-/1.5/-/1.0/1.1/-/ [-/-/-]) Pw tdm remote defect indicator 0xC0021 (hex) 786465 (dec) Communications alarm Major, -, Yellow The attachment circuit remote defect indication (dRDI or dRAI) received from the far end (via M bit) pdhCesoPsnTunnelPw (FP [-/-/3.1/3.1/-] /3.1/-/1.5/-/1.0/1.1/-/ [-/-/-]) Remote alarm indicator 0x1B (hex) 27 (dec) Communications alarm Major, -, Yellow RAI alarm indicates that the far-end reveiver has detected a fault This causes ssf signal inside NE due to bidirectionality of IP / MPLS layer pdhDs1PathTTPBid (FP [-/-/2.5/3.0/-] /2.5/-/1.1/1.0A/1.0/1.1/-/ [-/-/-]) pdhDs1PathMonTTPBid (FP [-/-/2.9/3.0/-] /2.9/-/1.1/1.0A/1.0/1.1/-/ [-/-/-]) pdhDs3PathTTPBid (FP [-/-/-/-/-] /-/-/1.2/-/-/-/-/ [-/-/-]) 8600 Network Element Faults 95 8600 Smart Routers Fault Management Configuration Guide Fault / Spt Fault Type Severity, Serv Aff, Led Description Resource Associated ([8660,8630 CDC1 / CDC2 / IFC1 / IFC2 / ELC1] / 8620 / 8602 / 8605 / 8607 / 8609 / 8611 / 8615 / [8665 vCU / LU1 / SU1]) Remote defect indicator 0xA (hex) 10 (dec) Communications alarm Major, -, Yellow The sdh/sonet remote defect indication received from the far end (cRDI) This causes ssf signal inside NE due to bidirectionality of IP / MPLS layer pdhP12sTTPBid (FP [-/-/2.0/3.0/-] /2.0/-/1.0/1.0A/1.0/1.1/-/ [-/-/-]) pdhP12sMonTTPBid (FP [-/-/2.9/3.0/-] /2.9/-/1.1/1.0A/1.0/1.1/-/ [-/-/-]) sdhMsTTPBid (FP [-/-/1.0/3.0/-] /1.0/-/-/-/-/-/-/ [-/-/-]) sdhVc4TTPBid (FP [-/-/1.0/3.0/-] /1.0/-/-/-/-/-/-/ [-/-/-]) sdhVc12TTPBid (FP [-/-/2.0/3.0/-] /2.0/-/-/-/-/-/-/ [-/-/-]) sdhLineTTPBid (FP [-/-/2.5/3.0/-] /2.5/-/-/-/-/-/-/ [-/-/-]) sdhStsTTPBid (FP [-/-/2.5/3.0/-] /2.5/-/-/-/-/-/-/ [-/-/-]) sdhVt15TTPBid (FP [-/-/2.5/3.0/-] /2.5/-/-/-/-/-/-/ [-/-/-]) 8600 Network Element Faults 8600 Smart Routers Fault Management Configuration Guide 96 Fault / Spt 76.8600-50115I © 2015 Coriant 76.8600-50115I © 2015 Coriant Fault Type Severity, Serv Aff, Led Description Resource Associated ([8660,8630 CDC1 / CDC2 / IFC1 / IFC2 / ELC1] / 8620 / 8602 / 8605 / 8607 / 8609 / 8611 / 8615 / [8665 vCU / LU1 / SU1]) Server signal fail 0xB (hex) 11 (dec) Communications alarm Critical, Service affecting, Red Defect in above layer set SSF to below layer (example defect in sdh regeneration section set SSF active to sdh multiplex section) (cSSF) atmInterface (FP [-/-/2.0/3.0/-] /2.0/-/1.0/1.0A/1.0/1.1/-/ [-/-/-]) lpoSlp (FP [-/-/1.0/3.0/4.0] /2.2/1.0/1.0/1.0A/1.0/1.1/1.0/ [-/7.0/-]) sdhRsTTPBid (FP [-/-/1.0/3.0/-] /1.0/-/-/-/-/-/-/ [-/-/-]) sdhMsTTPBid (FP [-/-/1.0/3.0/-] /1.0/-/-/-/-/-/-/ [-/-/-]) sdhVc4TTPBid (FP [-/-/1.0/3.0/-] /1.0/-/-/-/-/-/-/ [-/-/-]) sdhVc12TTPBid (FP [-/-/2.0/3.0/-] /2.0/-/-/-/-/-/-/ [-/-/-]) sdhSectionTTPBid (FP [-/-/2.5/3.0/-] /2.5/-/-/-/-/-/-/ [-/-/-]) sdhLineTTPBid (FP [-/-/2.5/3.0/-] /2.5/-/-/-/-/-/-/ [-/-/-]) sdhStsTTPBid (FP [-/-/2.5/3.0/-] /2.5/-/-/-/-/-/-/ [-/-/-]) sdhVt15TTPBid (FP [-/-/2.5/3.0/-] /2.5/-/-/-/-/-/-/ [-/-/-]) mplsOamLspSink (FP [2.8/4.1/-/-/-] /2.8/-/-/-/-/-/-/ [-/-/-]) Server signal partly fail 0x14 (hex) 20 (dec) Communications alarm Critical, Service affecting, Red Defect in above layer causes partial SSF to below layer (partial SSF is caused e.g if in ppp, mplscp protocol fails but ipcp protocol is OK) lpoSlp (FP [-/-/1.0/3.0/4.0] /1.0/1.0/1.0/1.0A/1.0/1.1/1.0/ [-/7.0/-]) 8600 Network Element Faults 97 8600 Smart Routers Fault Management Configuration Guide Fault / Spt Fault Type Severity, Serv Aff, Led Description Resource Associated ([8660,8630 CDC1 / CDC2 / IFC1 / IFC2 / ELC1] / 8620 / 8602 / 8605 / 8607 / 8609 / 8611 / 8615 / [8665 vCU / LU1 / SU1]) Session down 0x13 (hex) 19 (dec) Communications alarm Critical, Service affecting, None The session is down ipBgpNbrV4 (FP [1.0/4.1/-/-/-] /1.0/1.0/1.0/1.1/1.0/1.1/1.0/ [7.0/-/-]) ipBgpNbrVrfV4 (FP [1.0/4.1/-/-/-] /1.0/1.0/1.3/1.1/1.0/1.1/1.0/ [7.0/-/-]) ipBgpNbrVpmV4 (FP [1.0/4.1/-/-/-] /1.0/1.0/1.0/1.1/1.0/1.1/1.0/ [7.0/-/-]) ipBgpNbrVpnV4 (FP [1.0/4.1/-/-/-] /1.0/1.0/1.0/1.1/1.0/1.1/1.0/ [7.0/-/-]) Shdsl config init failure 0x1F0105 (hex) 2031877 (dec) Communications alarm Critical, Service affecting, Red Endpoint failure during initialization due to paired endpoint not able to support requested configuration dslShdslSegmentEndpoint (FP [-/-/-/-/-] /-/-/-/1.0A/-/-/-/ [-/-/-]) Shdsl line new conf not activated 0x1F010D (hex) 2031885 (dec) Communications alarm Warning, -, None SHDSL line configuration is changed, but not activated Please, restart line handshake to activate dslShdslLine (FP [-/-/-/-/-] /-/-/-/1.0A/-/-/-/ [-/-/-]) Shdsl no neighbor present 0x1F0107 (hex) 2031879 (dec) Communications alarm Critical, Service affecting, Red Endpoint failure during initialization due to no activation sequence detected from paired endpoint dslShdslSegmentEndpoint (FP [-/-/-/-/-] /-/-/-/1.0A/-/-/-/ [-/-/-]) Shdsl protocol init failure 0x1F0106 (hex) 2031878 (dec) Communications alarm Critical, Service affecting, Red Endpoint failure during initialization due to incompatible protocol used by the paired endpoint dslShdslSegmentEndpoint (FP [-/-/-/-/-] /-/-/-/1.0A/-/-/-/ [-/-/-]) 8600 Network Element Faults 8600 Smart Routers Fault Management Configuration Guide 98 Fault / Spt 76.8600-50115I © 2015 Coriant 76.8600-50115I © 2015 Coriant Fault Type Severity, Serv Aff, Led Description Resource Associated ([8660,8630 CDC1 / CDC2 / IFC1 / IFC2 / ELC1] / 8620 / 8602 / 8605 / 8607 / 8609 / 8611 / 8615 / [8665 vCU / LU1 / SU1]) Signal degrade 0xC (hex) 12 (dec) Communications alarm Major, -, Red Bit errors detected in received signal (cDEG) pdhP12sTTPBid (FP [-/-/2.0/3.0/-] /2.0/-/1.0/1.0A/1.0/1.1/-/ [-/-/-]) pdhP12sMonTTPBid (FP [-/-/2.9/3.0/-] /2.9/-/1.1/1.0A/1.0/1.1/-/ [-/-/-]) pdhDs1PathTTPBid (FP [-/-/-/-/-] /-/-/1.1/1.0A/1.0/1.1/-/ [-/-/-]) sdhMsTTPBid (FP [-/-/1.0/3.0/-] /1.0/-/-/-/-/-/-/ [-/-/-]) sdhVc4TTPBid (FP [-/-/1.0/3.0/-] /1.0/-/-/-/-/-/-/ [-/-/-]) sdhVc12TTPBid (FP [-/-/2.0/3.0/-] /2.0/-/-/-/-/-/-/ [-/-/-]) Signal internally down 0x90002 (hex) 589826 (dec) Communications alarm Critical, Service affecting, Red The data signal is down due to internal HW limitations for this module Please, check ESW Release Notes lpoSlp (FP [-/-/2.2/3.0/4.0] /2.2/1.0/1.0/1.0A/1.0/1.1/1.0/ [-/7.0/-]) Signal label mismatch 0xD (hex) 13 (dec) Communications alarm Critical, Service affecting, Red Received signal label is not valid (cSLM) sdhVc4TTPBid (FP [-/-/1.0/3.0/-] /1.0/-/-/-/-/-/-/ [-/-/-]) sdhVc12TTPBid (FP [-/-/2.0/3.0/-] /2.0/-/-/-/-/-/-/ [-/-/-]) sdhStsTTPBid (FP [-/-/2.5/3.0/-] /2.5/-/-/-/-/-/-/ [-/-/-]) sdhVt15TTPBid (FP [-/-/2.5/3.0/-] /2.5/-/-/-/-/-/-/ [-/-/-]) 8600 Network Element Faults 99 8600 Smart Routers Fault Management Configuration Guide Fault / Spt Fault Type Severity, Serv Aff, Led Description Resource Associated ([8660,8630 CDC1 / CDC2 / IFC1 / IFC2 / ELC1] / 8620 / 8602 / 8605 / 8607 / 8609 / 8611 / 8615 / [8665 vCU / LU1 / SU1]) Sync source blocked off 0x50006 (hex) 327686 (dec) Quality of service alarm Warning, -, Yellow Synchronization source from this interface is blocked off i.e not functioning The reason can be that synchronization is not supported at the current (negotiated) speed of the interface or interface has incompatible type of SFP (electrical) ethrSyncTTPBid (FP [-/-/-/-/-] /-/1.0/1.3/-/1.0/1.1/1.0/ [-/7.0/-]) Trace identifier mismatch A 0xE (hex) 14 (dec) Communications alarm Critical, Service affecting, Red Received Trace Identifier does not match with expected one and sdhTimaActionsEnabled is enabled (cTIM) sdhRsTTPBid (FP [-/-/1.0/3.0/-] /1.0/-/-/-/-/-/-/ [-/-/-]) sdhVc4TTPBid (FP [-/-/1.0/3.0/-] /1.0/-/-/-/-/-/-/ [-/-/-]) sdhVc12TTPBid (FP [-/-/2.0/3.0/-] /2.0/-/-/-/-/-/-/ [-/-/-]) sdhSectionTTPBid (FP [-/-/2.5/3.0/-] /2.5/-/-/-/-/-/-/ [-/-/-]) sdhStsTTPBid (FP [-/-/2.5/3.0/-] /2.5/-/-/-/-/-/-/ [-/-/-]) sdhVt15TTPBid (FP [-/-/2.5/3.0/-] /2.5/-/-/-/-/-/-/ [-/-/-]) 8600 Network Element Faults 8600 Smart Routers Fault Management Configuration Guide 100 Fault / Spt 76.8600-50115I © 2015 Coriant 76.8600-50115I © 2015 Coriant Fault Type Severity, Serv Aff, Led Description Resource Associated ([8660,8630 CDC1 / CDC2 / IFC1 / IFC2 / ELC1] / 8620 / 8602 / 8605 / 8607 / 8609 / 8611 / 8615 / [8665 vCU / LU1 / SU1]) Trace identifier mismatch B 0x11 (hex) 17 (dec) Communications alarm Warning, -, Yellow Received Trace Identifier does not match with expected one and sdhTimaActionsEnabled is disabled (cTIM) sdhRsTTPBid (FP [-/-/1.0/3.0/-] /1.0/-/-/-/-/-/-/ [-/-/-]) sdhVc4TTPBid (FP [-/-/1.0/3.0/-] /1.0/-/-/-/-/-/-/ [-/-/-]) sdhVc12TTPBid (FP [-/-/2.0/3.0/-] /2.0/-/-/-/-/-/-/ [-/-/-]) sdhSectionTTPBid (FP [-/-/2.5/3.0/-] /2.5/-/-/-/-/-/-/ [-/-/-]) sdhStsTTPBid (FP [-/-/2.5/3.0/-] /2.5/-/-/-/-/-/-/ [-/-/-]) sdhVt15TTPBid (FP [-/-/2.5/3.0/-] /2.5/-/-/-/-/-/-/ [-/-/-]) Tunnel bypass down 0x31 (hex) 49 (dec) Communications alarm Major, -, None Whole bypass tunnel is down i.e not operational (typically session is not properly established) mplsRsvpBypass (FP [2.11/4.1/-/-/-] /2.11/1.0/1.4/1.1/1.0/1.1/-/ [-/-/-]) Tunnel down 0x12 (hex) 18 (dec) Communications alarm Critical, Service affecting, None The whole tunnel is down i.e not operational (typically session(s) is not properly established) mplsRsvpTunnelPrimarySrc (FP [1.0/4.1/-/-/-] /1.0/1.0/1.0/1.0A/1.0/1.1/1.0/ [7.0/-/-]) Tunnel primary session down 0x15 (hex) 21 (dec) Communications alarm Major, -, None Tunnel's primary session is down However, since this session may have been protected, it is assumed here that data is still passing through If data passing is prevented for the whole tunnel, separate fault is issued to indicate that mplsRsvpTunnelPrimarySrc (FP [1.0/4.1/-/-/-] /1.0/1.0/1.0/1.0A/1.0/1.1/1.0/ [7.0/-/-]) Tunnel secondary session down 0x16 (hex) 22 (dec) Communications alarm Major, -, None Tunnel's secondary session is down However, since this session is protected, it is assumed here that data is still passing through If data passing is prevented for the whole tunnel, separate fault is issued to indicate that mplsRsvpTunnelSecondarySrc (FP [1.0/4.1/-/-/-] /1.0/1.0/1.0/1.0A/1.0/1.1/1.0/ [7.0/-/-]) 8600 Network Element Faults 8600 Smart Routers Fault Management Configuration Guide 101 Fault / Spt Fault Type Severity, Serv Aff, Led Description Resource Associated ([8660,8630 CDC1 / CDC2 / IFC1 / IFC2 / ELC1] / 8620 / 8602 / 8605 / 8607 / 8609 / 8611 / 8615 / [8665 vCU / LU1 / SU1]) Unequipped 0xF (hex) 15 (dec) Communications alarm Critical, Service affecting, Red Received signal label at UNEQ state (cUNEQ) sdhVc4TTPBid (FP [-/-/1.0/3.0/-] /1.0/-/-/-/-/-/-/ [-/-/-]) sdhVc12TTPBid (FP [-/-/2.0/3.0/-] /2.0/-/-/-/-/-/-/ [-/-/-]) sdhStsTTPBid (FP [-/-/2.5/3.0/-] /2.5/-/-/-/-/-/-/ [-/-/-]) sdhVt15TTPBid (FP [-/-/2.5/3.0/-] /2.5/-/-/-/-/-/-/ [-/-/-]) Vpls mesh incomplete 0x50014 (hex) 327700 (dec) Communications alarm Critical, Service affecting, None There is problem in delivering data between mesh members There are one or more mesh peers with active fault ethrBridgingInstance (FP [4.1/4.1/-/-/-] /-/-/-/-/-/-/1.0/ [7.0/-/-]) Vpls peer psn tunnel not found 0x50011 (hex) 327697 (dec) Communications alarm Critical, Service affecting, None PSN tunnel could not be found for the mesh peer ethrVplsPeer (FP [4.1/4.1/-/-/-] /-/-/-/-/-/-/1.0/ [7.0/-/-]) Vpls peer rx circuit down 0x50012 (hex) 327698 (dec) Communications alarm Critical, Service affecting, None Circuit is down in receive direction The reason may be that the LDP signalling is not successfully executed ethrVplsPeer (FP [4.1/4.1/-/-/-] /-/-/-/-/-/-/1.0/ [7.0/-/-]) Vpls peer tx circuit down 0x50013 (hex) 327699 (dec) Communications alarm Critical, Service affecting, None Circuit is down in transmit direction The reason may be that the LDP signalling is not successfully executed ethrVplsPeer (FP [4.1/4.1/-/-/-] /-/-/-/-/-/-/1.0/ [7.0/-/-]) 8600 Network Element Faults 8600 Smart Routers Fault Management Configuration Guide 102 Fault / Spt 76.8600-50115I © 2015 Coriant ... and/or other countries 76. 8600- 50115I © 2015 Coriant 8600 Smart Routers Fault Management Configuration Guide 8600 Smart Routers Fault Management Configuration Guide 76. 8600- 50115I © 2015 Coriant... fi-documentation@tellabs.com 8600 Smart Routers Fault Management Configuration Guide 14 76. 8600- 50115I © 2015 Coriant 8600 Smart Routers Discontinued Products 8600 Smart Routers Discontinued Products 8600 Smart Routers. .. [-/-/-]) 8600 Network Element Faults 8600 Smart Routers Fault Management Configuration Guide 28 Fault / Spt 76. 8600- 50115I © 2015 Coriant 76. 8600- 50115I © 2015 Coriant IP Basic Specific Faults Fault

Ngày đăng: 16/11/2017, 11:43

Mục lục

  • 8600 Smart Routers Fault Management Configuration Guide

    • Revision History

    • 8600 Smart Routers Technical Documentation

    • 8600 Smart Routers Discontinued Products

Tài liệu cùng người dùng

  • Đang cập nhật ...

Tài liệu liên quan