ĐIỀU HÒA KHÔNG KHÍ mitsubishi

69 372 0
ĐIỀU HÒA KHÔNG KHÍ mitsubishi

Đang tải... (xem toàn văn)

Tài liệu hạn chế xem trước, để xem đầy đủ mời bạn chọn Tải xuống

Thông tin tài liệu

MEE08K108 FM33568 / ISO 9001;2000 Series Pham Van Tung - email: vantung@tle.com.vn - dt: 0985.11.61.62 hoac 0439783799 may le 710 http://Global.MitsubishiElectric.com New publication effective May 2009 Specifications subject to change without notice The ISO 14000 series is a set of standards applying to environmental protection set by the International Standard Organization (ISO) The Air Conditioning & Refrigeration Systems Works acquired environmental management system standard ISO 14001 certification ISO Authorization System The ISO 9000 series is a plant authorization system relating to quality management as stipulated by the ISO ISO 9001 certifies quality management based on the "design, development, production, installation and auxiliary services" for products built at an authorized plant The Air Conditioning & Refrigeration Systems Works acquired ISO 9001 certification under Series 9000 of the International Standard Organization (ISO) based on a review of Quality management for the production of refrigeration and air conditioning equipment MITSUBISHI ELECTRIC MULTIPLE SPLIT TYPE AIR CONDITIONERS CITY MULTI AIR CONDITIONING SYSTEMS CM09WD-F Pham Van Tung - email: vantung@tle.com.vn - dt: 0985.11.61.62 hoac 0439783799 may le 710 Page1 At Mitsubishi Electric we strive to continually meet the increasing demands of our customers, being the first in the industry to offer highly advanced ‘inverter driven’ systems Using inverter technology our systems produce just the right amount of output to match the exact requirement of any building These systems work so efficiently that they don’t waste valuable energy by over-heating or overcooling, resulting in greatly reduced running costs Alternative systems that may appear cheaper, can often cost substantially more to run, making us the most cost effective choice all round As scientific evidence points to man-made chemicals for the damage caused to the ozone layer, we only use chlorine-free refrigerants that are safe with zero ODP (Ozone Depletion Potential) Accordingly, our systems require less energy to run, and have a significantly lower indirect global warming potential In short, we produce the most efficient equipment possible, while helping to protect the environment R 410A refrigerant nverter driven technology I ntelligent Power Module (IPM) technology I The City Multi range from Mitsubishi Electric provides precise control of energy input, through utilization of its Intelligent Power Module (IPM) technology By employing this technology, highly efficient operation is possible with compact units closely matching building requirements system VRF stands for Variable Refrigerant Flow A VRF air conditioning system modulates the flow of refrigerant depending upon the capacity requirements of the building In its simplest form, a VRF system comprises an air-cooled outdoor unit and a series of indoor units that regulate the air temperature inside an internal space V RF Our Latest Technologies working and living environments made possible with air conditioning altogether More and more people today are enjoying the benefits of comfortable air conditioning can also heat, doing away with the need for separate heating systems climate control is greater than ever Not only does it cool in the summer months, but well insulated and increasingly full of electronic equipment, the need for effective cleanliness of air inside any building, large or small With today's buildings being so Air conditioning is an ideal way of controlling the temperature, movement and systems available on the market some of the most energy efficient today We pride ourselves on offering industry - a position we still enjoy forefront of the air conditioning Mitsubishi Electric, quickly rose to the 1907, the company known today as products and services Founded in name associated with a variety of Mitsubishi is a trusted household Known the world over, the name from Mitsubishi Electric Unsurpassed air conditioning Optional parts Outdoor unit Indoor unit Remote Controller Features of Mitsubishi Electric air conditioners Contents Page2 Page 131-134 Page82-129 Page39-80 Page17-37 Page 1-16 Pham Van Tung - email: vantung@tle.com.vn - dt: 0985.11.61.62 hoac 0439783799 may le 710 Page3 >All the City Multi outdoor units are made in Japan under stringent control PEFY-VMR Designed and manufactured to the highest standards, the City Multi range offers one of the most reliable air conditioning systems available Simple to install and easy to maintain, this range provides ideal solutions you can trust to protect your investment Reliable PFFY-VKM PEFY-VMS1 Sophisticated yet simple technology Indoor unit Outdoor unit ON 27˚c Joint ON 25˚c ON 25˚c Inverter driven compressor OFF OFF ON 23˚c Header Page4 Controller ON 26˚c VRF is a multi and direct expansion type air conditioning system where by one outdoor unit can be connected with multiples indoor units The amount of refrigerant can be regulated freely according to the load on the indoor unit by the inverter driven compressor in the outdoor unit Zoning in a small office is possible with a small capacity indoor unit Energy conservation is easily handled because individual indoor units can stop and start their operation as needed There are various indoor units available in order to suit various interior design needs Mitsubishi Electric sets the boundaries of VRF technology with the City Multi range, which is available using R410A refrigerant with zero ODP (Ozone Depletion Potential) The range has been specifically designed for today’s building requirements and addresses key market issues such as energy efficiency, adaptability and reliability With user friendly control systems utilizing Internet technology and integrated cooling and ventilation indoor units, City Multi is the benchmark and market leader in VRF technology Our answer to VRF V RF system Pham Van Tung - email: vantung@tle.com.vn - dt: 0985.11.61.62 hoac 0439783799 may le 710 Page5 Compressor Evaporator Accumulator Condenser LEV Bypass Medium temperature LEV Low temperature Supercooled heat exchanger High temperature City Multi Refrigerant Circuit Compressor Evaporator Accumulator Condenser LEV Common Refrigerant Circuit The unique Heat Interchange Circuit (HIC) enhances efficiency by providing additional sub-cooling and allows the expansion device to effectively control the refrigerant distribution, thereby increasing the operating efficiency and reducing the volume of refrigerant in each system Heat Interchange Circuit Unbeatable Efficiency Heat exchanger Low Starting Currents 15% 100% 100% capacity Inverter inverter compressor Y series 8-18HP R2 series 8-16HP load 100% capacity Stable and smooth operation No1 inverter compressors Y series 20-36HP R2 series 18-32HP No1 No2 load 100% capacity No1 No1 No2 inverter compressors Y series 38-50HP No1 No2 No3 Page6 load The outdoor unit combinations comprise 1unit for 8-18HP systems (for R2 up to 16HP), units for 20-36HP systems (for R2, 18-32HP) and units for 38-50HP systems (Y series only) Each unit carries one inverter compressor making simple and highly reliable control possible Not only does it allow low starting currents, the inverter-driven compressor also provides precise indoor comfort and adapts to the air conditioning load * image Cooling:74Hz Heating:81Hz Compressor Frequency 15Hz Linear Capacity Control Heating / Cooling Capacity All City Multi compressors are inverter-driven type -Capable of precisely matching a building's cooling and heating demands Using proven single inverter driven compressor technology, the City Multi range is favored by the industry for low starting currents (only amps for a 16HP YHM-A outdoor unit), and smooth transition across the range of compressor frequencies When an inverter driven system is operating at partial load, the energy efficiency of the system is significantly higher than that of a standard fixed speed, non inverter system The fixed speed system can only operate at 100%, however, partial load conditions prevail for the majority of the time Therefore fixed speed systems cannot match the annual efficiencies of inverter driven systems The compressor varies its speed to match the indoor cooling or heating demand and therefore only consumes the energy that is required Using inverter driven technology saves energy for several reasons: nverter Driven Compressor Technology - now up to 50HP I Pham Van Tung - email: vantung@tle.com.vn - dt: 0985.11.61.62 hoac 0439783799 may le 710 Page7 COP 2.0 2.5 3.0 3.5 4.0 4.5 5.0 Standard model 4.02 * Average COP of cooling / heating Our equivalent product 10 years before PUHY-200YMF R22 2.87 Energy Saving 29% 34% 4.33 High COP model Energy Saving High COP (Coefficient of Performance) is realized Comparison of COP (energy efficiency) – 8HP system Total Energy Conservation Page8 COP stands for “Coefficient of Performance” It is a measure of the useful energy a system can deliver compared to the energy it consumes It is calculated by dividing the energy output by the energy input of a system The higher the figure then the more efficient the system is deemed to be Mitsubishi Electric VRF models, the world's highest energy-efficient air-conditioners, will undoubtedly reduce millions of tons of CO2 emissions The importance of COP A highly efficient R410A scroll compressor design results in less friction losses at the motor A simplified refrigerant circuit (low pressure loss) including a new accumulator design also adds a few more points to the efficiency scale Enhancements to the heat interchange circuit, an inverter driven fan motor and a heat exchanger design again add vital increases to overall system efficiencies and COPs Technology is key when increased efficiency is demanded The City Multi YHM-A range is able to deliver this in simple ways The difference between YHM-A and previous Mitsubishi Electric models In addition, IPM technology ensures effective performance under partial load conditions, a condition that most systems will be in for the majority of the normal working life cycle By taking account the efficiency at both part load, and peak load conditions, R410A City Multi is designed to provide unbeatable year round/seasonal efficiency The YHM-A range from Mitsubishi Electric provides precise control of energy input, through utilization of its Intelligent Power Module (IPM) technology By employing this technology it is possible to closely match the building requirements, achieving more accurate control of the occupied space By using incremental 1Hz steps of capacity control, the amount of power input required is significantly reduced, resulting in greatly improved COP’s Technology I ntelligent Power Module (IPM) Pham Van Tung - email: vantung@tle.com.vn - dt: 0985.11.61.62 hoac 0439783799 may le 710 Page9 * RoHS Directive: the restriction of the use of certain hazardous substances in electrical and electronic equipment that has been sold in EU since July 2006 Enhancing environmental care (measures for the RoHS Directive and the refrigerant reduction) Every unit is in compliance with the RoHS Directive,* which stands for the Restriction of Hazardous Substances: Lead-free soldering is used to avoid Lead Groundwater Contamination on the print board The amount of refrigerant on the unit has also been reduced to enhance environmental care For the Environment Improvement of reliability and easy maintenance New Design Photo : Y series Improvement of COP Improvement of COP Reduction of operation noise Page10 R410A is a more efficient refrigerant as it has a higher specific heat capacity when compared to R407C or R22 This higher energy carrying capacity allows for smaller pipe sizes, longer pipe runs and reduces the volume of refrigerant within a system This is a major factor when concerning safety and environmental requirements in the design, manufacture, installation, operation, maintenance and disposal or refrigerating systems Technical aspects of refrigerant Because of these restrictions, R410A refrigerants are desirable R410A is a blend of HFCs, which not deplete the ozone R22, an HCFC-based refrigerant, has been a popular choice for most chillers R22 has been targeted by the Montreal Protocol to be phased out in new equipment Additionally, governments in many countries are enforcing a ban of HCFC-based refrigerants for new installations History of refrigerant E fficient R410A refrigerant Pham Van Tung - email: vantung@tle.com.vn - dt: 0985.11.61.62 hoac 0439783799 may le 710 Page11 5HP 7.5HP 10HP 15HP System Total 15HP indoor unit is connected with 10HP outdoor unit C 15HP B Total heat recovery operation A Mainly heating operation ( 5HP 7.5HP 10HP Cooling indoor unit Operation pattern of ) By the heat recovery system, the more frequently cooling and heating simultaneous operation is carried out, the higher energy-saving effect becomes air conditioning you can rely on Affordable & Effective Heating indoor unit Meeting room Heating Refrigerant piping: 2-pipe type Outdoor unit Meeting room Cooling Office Heating BC controller Office compartment Heating Office Cooling Page12 Equipment room Cooling Flexibility and efficiency are key factors when selecting a heat recovery system For example, while a heat pump system is adequate for a large open-plan office, an office that has a more partitioned structure will require the need to simultaneously heat or cool different sections of the office according to each user's individual preferences The efficiency of this type of system comes from the ability to use the by-products of cooling and heating to transfer energy where it is required, thus acting as a balanced heat exchanger achieving up to 20% cost savings over a conventional heat pump system The number of connection sites needed for a R2 / WR2 system are also significantly lower than those needed for a three pipe version This helps to reduce installation costs, further increasing the savings associated with CITY MULTI Why Heat Recovery? Unique to Mitsubishi Electric, our heat recovery technology uses just two pipes, as opposed to the market conventional three Designed for effective simultaneous heating and cooling our R2 and WR2 systems offer substantial savings on installation and annual running costs U nique technology Pham Van Tung - email: vantung@tle.com.vn - dt: 0985.11.61.62 hoac 0439783799 may le 710 Page13 Comparison example of piping connection sites “2-pipe” system provides Better Efficiency and Performance 2-pipe system Outdoor unit High pressure gas-liquid phase refrigerant High pressure and low pressure decides the compressor frequency and the mode of heat exchanger, and control the amounts of heat exchange Heating 25˚C Gas refrigerant Liquid refrigerant Heating 26˚C Cooling 24˚C Heating=gas refrigerant Cooling=liquid refrigerant Meet the demand of cooling / heating flexibly Page14 Adjust the refrigerant flow by temperature difference between inlet and outlet BC controller divides refrigerant to each indoor unit properly in compliance with the operation mode of each indoor unit Gas-liquid 2-phase refrigerant from outdoor unit into gas refrigerant and liquid refrigerant is divided by gas-liquid separator in BC controller R2/WR2 refrigerant circuit Liquid refrigerant Cooling 22˚C Indoor unit Gas refrigerant BC controller The BC Controller houses a liquid/gas separator, allowing the outdoor unit to deliver a mixture (2 phase) of hot gas for heating and liquid for cooling, all through the same pipe Three pipe systems allocate a pipe to each of these phases When this mixture arrives at the BC Controller, it is separated and the correct phase delivered to each indoor unit depending on the individual requirement of either heating or cooling BC Controller The secret of City Multi heat recovery systems lies in the How does the R2 /WR2 Heat Recovery System operate on Pipe’s? the only T he world s first and Pham Van Tung - email: vantung@tle.com.vn - dt: 0985.11.61.62 hoac 0439783799 may le 710 Page15 Water cooled systems are ideally suited for use in temperate and cooler climates since heat exchange with the outside air is not required Buildings in which there are large room temperature differences between sunny and unsunny rooms Hotels in which there are a lot of individual operation needs Buildings that require all year cooling Example, Tenant buildings in which kitchens and offices exist together Buildings in which equipment rooms and offices exist together It is suggested that Water-Cooled systems are used in the buildings in which there are heating and cooling needs as follows Simultaneous heating and cooling operation is available (WR2 series) Any heat source system that can supply heat source water between 10˚C~45˚C can be used Water cooled systems can be used even in buildings that are taller than 50m by running a main water pipe through each floor Water Cooled City Multi Benefits Equipment room Cooling Meeting room Heating Meeting room Heating Equipment room Cooling Director's room Heating Water piping Water circuit Heat recovery Heat source unit Heat recovery Indoor units Heat recovery Indoor units Refrigerant Circuit BC controller Double heat recovery (WR2) Heat source unit Heat source unit BC controller Cooling Heating Page16 Mitsubishi Electric now offers double heat recovery operation The first heat recovery is within the refrigerant system Simultaneous cooling and heating operation is available with heat recovery performed between indoor units The second heat recovery is within the water loop, where heat recovery is performed between the PQRY units This double heat recovery operation substantially improves energy efficiency and makes the system the ideal solution to the requirements of modern office buldings, where some areas require cooling even in winter WR2(Heat recovery type) It is possible now to combine the features of VRF with a water circuit using City Multi WR2/WY In this case the heat is rejected to a water source rather than to the outside air The advantages of water cooled systems are that the water can be delivered at optimised temperatures and volumes, which allows even greater flexibility and increased COP >A unique offering from Mitsubishi Electric What is Water-Cooled? E nergy Saving Technology Pham Van Tung - email: vantung@tle.com.vn - dt: 0985.11.61.62 hoac 0439783799 may le 710 Page17 Centralized Remote Controller Individual Remote Controller R emote Controller Good controls will benefit any application, large or small Air conditioning products need to react to a variety of factors: different room sizes, usage and staff levels; changes in the climate; electronic equipment and lighting the list goes on So whatever the application, optimum control of air conditioning systems is essential and will result in a constant, comfortable environment, which in turn is both energy and cost efficient Operating an air conditioning system without the right control can prove costly It's therefore important to ensure that every system is correctly specified to the degree of control it requires Mitsubishi Electric have a wide range of controls available 'off-the-shelf' and individual control systems can be specifically designed to match The need for control is paramount in order to optimise the performance of any air conditioning system and minimize its running costs Mitsubishi Electric offers a wide range of control options designed to meet such needs Remote Controller With the array of comprehensive control systems available from Mitsubishi Electric, it becomes simple to design and install air conditioning systems From a simple hand-held controller to a AG-150A system - you are in control The simpler, the better When an air conditioning system is not properly controlled, it will not run as efficiently as it should For every degree that the system deviates from the required temperature, energy costs can rise by up to 5% Specify one of the many control options from Mitsubishi Electric to ensure air conditioning works as intended, whilst giving the optimum amount of control A degree of difference The importance of control Page18 Pham Van Tung - email: vantung@tle.com.vn - dt: 0985.11.61.62 hoac 0439783799 may le 710 Page107 ø19.05 (ø3/4) Brazed R410A ✕ 9.0kg (20 lbs) ❇4 -5˚C (23˚F) DB/-6˚C (21˚F) WB~21˚C (70˚F) DB/15.5˚C (60˚F) WB with cooling/heating mixed operation ❇3 -5˚C (23˚F) DB/-6˚C (21˚F) WB~21˚C (70˚F) DB/15.5˚C (60˚F) WB with cooling/heating mixed operation Outdoor Unit R410A ✕ 9.0kg R410A ✕ 11.5kg R410A ✕ 9.0kg R410A ✕ 11.5kg (20 lbs) (26 lbs) (20 lbs) (26 lbs) ø9.52 (ø3/8) Brazed ø12.7 (ø1/2) Brazed ø22.2 (ø7/8) Brazed ø19.05 (ø3/4) Brazed ø22.2 (ø7/8) Brazed Outdoor Twinning kit : CMY-Y100VBK2 joint : CMY-Y102S / L-G2, CMY-Y202-G2 Header : CMY-Y104 / 108 / 1010-G ❇3 Height without legs 1650mm (65 in.) ❇2 Nominal heating conditions Indoor 20˚C (68˚F) DB,Outdoor 7˚C (45˚F) DB/6˚C (43˚F) WB Pipe length 7.5 m (24-9/16 ft), Level difference m (0 ft) ❇1 Nominal cooling conditions Indoor 27˚C (81˚F) DB/19˚C (66˚F) WB, Outdoor 35˚C (95˚F) DB Pipe length 7.5 m (24-9/16 ft), Level difference m (0 ft) mm(in.) mm(in.) R410A ✕ 9.0kg (20 lbs) ❇2 Nominal heating conditions Indoor 20˚C (68˚F) DB,Outdoor 7˚C (45˚F) DB/6˚C (43˚F) WB Pipe length 7.5 m (24-9/16 ft), Level difference m (0 ft) ❇1 Nominal cooling conditions Indoor 27˚C (81˚F) DB/19˚C (66˚F) WB, Outdoor 35˚C (95˚F) DB Pipe length 7.5 m (24-9/16 ft), Level difference m (0 ft) Outdoor unit Note: Note: Optional parts Pipe between Liquid unit distributor Gas Refrigerant Type ✕ Original charge Set name PUHY-EP400YSHM-A(-BS) PUHY-EP450YSHM-A1(-BS) PUHY-EP500YSHM-A(-BS) Power source 3-phase 4-wire 380-400-415V 50/60Hz ❇1 kW Cooling capacity 50.0 56.0 45.0 ❇1 BTU/h (Nominal) 170,600 191,100 153,500 kW Power input 11.87 13.46 10.41 A Current input 20.0-19.0-18.3 22.7-21.5-20.8 17.5-16.6-16.0 COP (kW/kW) 4.21 4.16 4.32 W.B 15~24˚C (59~75˚F) Temp ❇4 Indoor range of D.B - 5~43˚C (23~109˚F) Outdoor cooling ❇2 kW Heating capacity 56.0 63.0 50.0 ❇2 BTU/h (Nominal) 191,100 215,000 170,600 kW Power input 13.05 15.14 11.54 A Current input 22.0-20.9-20.1 25.5-24.2-23.4 19.4-18.5-17.8 COP (kW/kW) 4.29 4.16 4.33 Temp ❇4 Indoor temp D.B 15~27˚C (59~81˚F) range Outdoor temp W.B -20~15.5˚C (-4~60˚F) of heating Indoor unit Total capacity 50~130% of outdoor unit capacity connectable Model/Quantity P15~P250 / 1~39 P15~P250 / 1~43 P15~P250 / 1~35 Sound pressure level dB 62 62 60 (measured in anechoic room) mm(in.) Liquid Diameter of ø15.88 (ø5/8) Brazed ø15.88 (ø5/8) Brazed ø12.7 (ø1/2) Brazed mm(in.) refrigerant pipe Gas ø28.58 (ø1-1/8) Brazed ø28.58 (ø1-1/8) Brazed ø28.58 (ø1-1/8) Brazed Outdoor unit and Outdoor unit PUHY-EP200YHM-A(-BS) PUHY-EP200YHM-A(-BS) PUHY-EP200YHM-A(-BS) PUHY-EP250YHM-A(-BS) PUHY-EP200YHM-A(-BS) PUHY-EP300YHM-A(-BS) External finish Pre-coated galvanized steel sheets (+ powder coating for-BS type) mm 1,710 ✕ 920 ✕ 760 1,710 ✕ 1,220 ✕ 760 1,710 ✕ 920 ✕ 760 1,710 ✕ 1,220 ✕ 760 1,710 ✕ 920 ✕ 760 1,710 ✕ 920 ✕ 760 External dimension H ✕ W ✕ D in ❇3 67-3/8 ✕ 36-1/4 ✕ 29-15/16 67-3/8 ✕ 36-1/4 ✕ 29-15/16 67-3/8 ✕ 36-1/4 ✕ 29-15/16 67-3/8 ✕ 48-1/16 ✕ 29-15/16 67-3/8 ✕ 36-1/4 ✕ 29-15/16 67-3/8 ✕ 48-1/16 ✕ 29-15/16 kg(lbs) Net weight 200 (441) 245 (541) 200 (441) 245 (541) 200 (441) 200 (441) Heat exchanger Salt-resistant cross fin & copper tube Type Inverter scroll hermetic compressor Compressor Starting method Inverter kW Motor output 5.4 6.7 5.4 8.3 5.4 5.4 m /min 185 225 185 225 185 185 L/s Air flow rate 3,083 3,750 3,083 3,750 3,083 3,083 cfm FAN 6,532 7,945 6,532 7,945 6,532 6,532 Type ✕ Quantity Propeller fan ✕ Propeller fan ✕ Propeller fan ✕ Propeller fan ✕ Propeller fan ✕ Propeller fan ✕ kW Motor output 0.46 ✕ 0.46 ✕ 0.46 ✕ 0.46 ✕ 0.46 ✕ 0.46 ✕ High pressure protection High pressure sensor, High pressure switch 4.15 MPa (601 psi) Protection Inverter circuit (COMP./FAN) Over-heat protection, Over-current protection Compressor Over-heat protection Specifications Specifications PUHY-EP200YHM-A(-BS) PUHY-EP250YHM-A(-BS) PUHY-EP300YHM-A(-BS) Power source 3-phase 4-wire 380-400-415V 50/60Hz ❇1 kW 22.4 33.5 Cooling capacity 28.0 ❇1 BTU/h 76,400 114,300 (Nominal) 95,500 kW 5.18 8.25 6.82 Power input A 8.7-8.3-8.0 13.9-13.2-12.7 11.5-10.9-10.5 Current input 4.32 4.06 4.10 COP (kW/kW) W.B Temp ❇3 Indoor 15~24˚C (59~75˚F) range of D.B - 5~43˚C (23~109˚F) Outdoor cooling ❇2 25.0 37.5 kW Heating capacity 31.5 ❇2 BTU/h 85,300 128,000 (Nominal) 107,500 5.77 9.28 kW 7.59 Power input 9.7-9.2-8.9 15.6-14.8-14.3 A 12.8-12.1-11.7 Current input 4.33 4.04 4.15 COP (kW/kW) Temp ❇3 Indoor temp D.B 15~27˚C (59~81˚F) range -20~15.5˚C (-4~60˚F) Outdoor temp W.B of heating Indoor unit Total capacity 50~130% of outdoor unit capacity P15~P250 / 1~17 P15~P250 / 1~26 connectable Model/Quantity P15~P250/1~21 Sound pressure level 57 60 dB 60 (measured in anechoic room) ø9.52 (ø3/8) Brazed Diameter of mm(in.) ø9.52 (ø3/8) Brazed (ø12.7 (ø1/2) Brazed,total length>=90m) ø9.52 (ø3/8) Brazed (ø12.7 (ø1/2) Brazed , total length>=40m) Liquid ø22.2 (ø7/8) Brazed ø19.05 (ø3/4) Brazed refrigerant pipe Gas mm(in.) ø22.2 (ø7/8) Brazed External finish Pre-coated galvanized steel sheets (+ powder coating for-BS type) 1,710 (without legs 1,650) ✕ 1,220 ✕ 760 mm 1,710 (without legs 1,650) ✕ 1,220✕760 1,710 (without legs 1,650) ✕ 920 ✕ 760 External dimension H ✕ W ✕ D 67-3/8 (without legs 65) ✕ 48-1/16 ✕ 29-15/16 in 67-3/8 (without legs 65) ✕ 36-1/4 ✕ 29-15/16 67-3/8 (without legs 65) ✕ 48-1/16 ✕ 29-15/16 245 (541) Net weight kg(lbs) 245 (541) 200 (441) Heat exchanger Salt-resistant cross fin & copper tube Inverter scroll hermetic compressor Type Compressor Starting method Inverter 8.3 kW 6.7 Motor output 5.4 225 m /min 225 185 3,750 L/s 3,750 Air flow rate 3,083 7,945 FAN cfm 7,945 6,532 Propeller fan ✕ Propeller fan ✕ Type ✕ Quantity Propeller fan ✕ 0.46 ✕ kW 0.46 ✕ Motor output 0.46 ✕ High pressure sensor, High pressure switch 4.15 MPa (601 psi) High pressure protection Protection Inverter circuit (COMP./FAN) Over-heat protection, Over-current protection Over-heat protection Compressor R410A ✕ 11.5kg (26 lbs) Refrigerant Type ✕ Original charge R410A ✕ 11.5 kg (26lbs) R410A ✕ 9.0kg (20 lbs) joint : CMY-Y102S / L-G2 joint : CMY-Y102S/L-G2 joint : CMY-Y102S-G2 Optional parts Header : CMY-Y104 / 108 / 1010-G Header : CMY-Y104/108/1010-G Header : CMY-Y104 / 108 / 1010-G OUTDOOR UNIT Y Series - High COP PUHY-EP YSHM-A(-BS) OUTDOOR UNIT Y Series - High COP PUHY-EP YHM-A(-BS) Page108 Pham Van Tung - email: vantung@tle.com.vn - dt: 0985.11.61.62 hoac 0439783799 may le 710 Page109 ❇2 Nominal heating conditions Indoor 20˚C (68˚F) DB,Outdoor 7˚C (45˚F) DB/6˚C (43˚F) WB Pipe length 7.5 m (24-9/16 ft), Level difference m (0 ft) ❇3 Height without legs 1650mm (65 in.) ❇4 -5˚C (23˚F) DB/-6˚C (21˚F) WB~21˚C (70˚F) DB/15.5˚C (60˚F) WB with cooling/heating mixed operation ❇3 Height without legs 1650mm (65 in.) ❇4 -5˚C (23˚F) DB/-6˚C (21˚F) WB~21˚C (70˚F) DB/15.5˚C (60˚F) WB with cooling/heating mixed operation ø9.52 (ø3/8) Brazed ø19.05 (ø3/4) Brazed Outdoor Twinning kit : CMY-Y300VBK2 joint : CMY-Y102S / L-G2, CMY-Y202 / 302-G2 Header : CMY-Y104 / 108 / 1010-G 5.4 185 3,083 6,532 Propeller fan ✕ 0.46 ✕ High pressure sensor, High pressure switch 4.15 MPa (601 psi) Over-heat protection, Over-current protection Over-heat protection R410A ✕ 9.0kg (20 lbs) ❇2 Nominal heating conditions Indoor 20˚C (68˚F) DB,Outdoor 7˚C (45˚F) DB/6˚C (43˚F) WB Pipe length 7.5 m (24-9/16 ft), Level difference m (0 ft) mm(in.) mm(in.) R410A ✕ 9.0kg (20 lbs) 5.4 185 3,083 6,532 Propeller fan ✕ 0.46 ✕ R410A ✕ 11.5kg (26 lbs) ø12.7 (ø1/2) Brazed ø22.2 (ø7/8) Brazed 8.3 225 3,750 7,945 Propeller fan ✕ 0.46 ✕ Outdoor Unit ø19.05 (ø3/4) Brazed ø34.93 (ø1-1/4) Brazed PUHY-EP200YHM-A(-BS) PUHY-EP200YHM-A(-BS) PUHY-EP300YHM-A(-BS) Pre-coated galvanized steel sheets (+ powder coating for-BS type) 1,710 ✕ 920 ✕ 760 1,710 ✕ 920 ✕ 760 1,710 ✕ 1,220 ✕ 760 67-3/8 ✕ 36-1/4 ✕ 29-15/16 67-3/8 ✕ 36-1/4 ✕ 29-15/16 67-3/8 ✕ 48-1/16 ✕ 29-15/16 200 (441) 200 (441) 245 (541) Salt-resistant cross fin & copper tube Inverter scroll hermetic compressor Inverter 63 50~130% of outdoor unit capacity P15~P250 / 1~50 -20~15.5˚C (-4~60˚F) 88.0 300,300 20.00 33.7-32.0-30.9 4.40 15~27˚C (59~81˚F) - 5~43˚C (23~109˚F) PUHY-EP700YSHM-A(-BS) 3-phase 4-wire 380-400-415V 50/60Hz 80.0 273,000 20.99 35.4-33.6-32.4 3.81 15~24˚C (59~75˚F) ❇1 Nominal cooling conditions Indoor 27˚C (81˚F) DB/19˚C (66˚F) WB, Outdoor 35˚C (95˚F) DB Pipe length 7.5 m (24-9/16 ft), Level difference m (0 ft) Note: Optional parts Pipe between Liquid unit distributor Gas Refrigerant Type ✕ Original charge mm External dimension H ✕ W ✕ D ❇3 in Net weight kg(lbs) Heat exchanger Type Compressor Starting method Motor output kW m /min Air flow rate L/s FAN cfm Type ✕ Quantity Motor output kW High pressure protection Protection Inverter circuit (COMP./FAN) Compressor Power input kW Current input A COP (kW/kW) Temp ❇4 Indoor temp D.B range Outdoor temp W.B of heating Indoor unit Total capacity connectable Model/Quantity Sound pressure level dB (measured in anechoic room) Diameter of Liquid mm(in.) refrigerant pipe Gas mm(in.) Outdoor unit , Outdoor unit , and Outdoor unit External finish Set name Power source ❇1 Cooling capacity kW ❇1 BTU/h (Nominal) Power input kW Current input A COP (kW/kW) Temp ❇4 Indoor W.B range of Outdoor D.B cooling ❇2 Heating capacity kW ❇2 BTU/h (Nominal) Specifications OUTDOOR UNIT Y Series - High COP PUHY-EP YSHM-A(-BS) ❇1 Nominal cooling conditions Indoor 27˚C (81˚F) DB/19˚C (66˚F) WB, Outdoor 35˚C (95˚F) DB Pipe length 7.5 m (24-9/16 ft), Level difference m (0 ft) Outdoor unit Note: Set name PUHY-EP550YSHM-A1(-BS) PUHY-EP600YSHM-A(-BS) PUHY-EP650YSHM-A(-BS) Power source 3-phase 4-wire 380-400-415V 50/60Hz ❇1 kW Cooling capacity 69.0 73.0 63.0 ❇1 BTU/h (Nominal) 235,400 249,100 215,000 Power input kW 16.99 18.34 15.44 Current input A 28.6-27.2-26.2 30.9-29.4-28.3 26.0-24.7-23.8 COP (kW/kW) 4.06 3.98 4.08 W.B 15~24˚C (59~75˚F) Temp ❇4 Indoor range of Outdoor D.B - 5~43˚C (23~109˚F) cooling ❇2 kW Heating capacity 76.5 81.5 69.0 ❇2 BTU/h (Nominal) 261,000 278,100 235,400 Power input kW 18.93 19.13 16.82 Current input A 31.9-30.3-29.2 32.2-30.6-29.5 28.3-26.9-26.0 COP (kW/kW) 4.04 4.26 4.10 Temp ❇4 Indoor temp D.B 15~27˚C (59~81˚F) range Outdoor temp W.B -20~15.5˚C (-4~60˚F) of heating Indoor unit Total capacity 50~130% of outdoor unit capacity connectable Model/Quantity P15~P250 / 1~50 P15~P250 / 1~50 P15~P250 / 1~47 Sound pressure level dB 63 63.5 63 (measured in anechoic room) Liquid mm(in.) Diameter of ø15.88 (ø5/8) Brazed ø15.88 (ø5/8) Brazed ø15.88 (ø5/8) Brazed mm(in.) refrigerant pipe Gas ø28.58 (ø1-1/8) Brazed ø28.58 (ø1-1/8) Brazed ø28.58 (ø1-1/8) Brazed Outdoor unit and Outdoor unit PUHY-EP250YHM-A(-BS) PUHY-EP300YHM-A(-BS) PUHY-EP300YHM-A(-BS) PUHY-EP300YHM-A(-BS) PUHY-EP300YHM-A(-BS) PUHY-P350YHM-A(-BS) Pre-coated galvanized steel sheets (+ powder coating for-BS type) External finish mm 1,710 ✕ 1,220 ✕ 760 1,710 ✕ 1,220 ✕ 760 1,710 ✕ 1,220 ✕ 760 1,710 ✕ 1,220 ✕ 760 1,710 ✕ 1,220 ✕ 760 1,710 ✕ 1,220 ✕ 760 External dimension H ✕ W ✕ D ❇3 in 67-3/8 ✕ 48-1/16 ✕ 29-15/16 67-3/8 ✕ 48-1/16 ✕ 29-15/16 67-3/8 ✕ 48-1/16 ✕ 29-15/16 67-3/8 ✕ 48-1/16 ✕ 29-15/16 67-3/8 ✕ 48-1/16 ✕ 29-15/16 67-3/8 ✕ 48-1/16 ✕ 29-15/16 kg(lbs) 245 (541) 245 (541) 245 (541) 245 (541) Net weight 245 (541) 245 (541) Salt-resistant cross fin & copper tube Heat exchanger Inverter scroll hermetic compressor Type Inverter Compressor Starting method Motor output kW 8.3 8.3 8.3 10.3 6.7 8.3 m /min 225 225 225 225 225 225 Air flow rate L/s 3,750 3,750 3,750 3,750 3,750 3,750 7,945 7,945 7,945 7,945 cfm FAN 7,945 7,945 Type ✕ Quantity Propeller fan ✕ Propeller fan ✕ Propeller fan ✕ Propeller fan ✕ Propeller fan ✕ Propeller fan ✕ Motor output 0.46 ✕ 0.46 ✕ 0.46 ✕ 0.46 ✕ kW 0.46 ✕ 0.46 ✕ High pressure sensor, High pressure switch 4.15 MPa (601 psi) High pressure protection Over-heat protection, Over-current protection Protection Inverter circuit (COMP./FAN) Over-heat protection Compressor R410A ✕ 11.5kg R410A ✕ 11.5kg R410A ✕ 11.5kg R410A ✕ 11.5kg R410A ✕ 11.5kg R410A ✕ 11.5kg Refrigerant Type ✕ Original charge (26 lbs) (26 lbs) (26 lbs) (26 lbs) (26 lbs) (26 lbs) ø12.7 (ø1/2) Brazed mm(in.) ø9.52 (ø3/8) Brazed Pipe between Liquid ø22.2 (ø7/8) Brazed ø28.58 (ø1-1/8) Brazed mm(in.) ø22.2 (ø7/8) Brazed unit distributor Gas Outdoor Twinning kit : CMY-Y100VBK2 joint : CMY-Y102S / L-G2, CMY-Y202 / 302-G2 Optional parts Header : CMY-Y104 / 108 / 1010-G Specifications OUTDOOR UNIT Y Series - High COP PUHY-EP YSHM-A (-BS) Page110 Pham Van Tung - email: vantung@tle.com.vn - dt: 0985.11.61.62 hoac 0439783799 may le 710 Page111 ❇1 Nominal cooling conditions Indoor 27˚C (81˚F) DB/19˚C (66˚F) WB, Outdoor 35˚C (95˚F) DB Pipe length 7.5 m (24-9/16 ft), Level difference m (0 ft) ❇2 Nominal heating conditions Indoor 20˚C (68˚F) DB,Outdoor 7˚C (45˚F) DB/6˚C (43˚F) WB Pipe length 7.5 m (24-9/16 ft), Level difference m (0 ft) ❇3 Height without legs 1650mm (65 in.) ❇4 -5˚C (23˚F) DB/-6˚C (21˚F) WB~21˚C (70˚F) DB/15.5˚C (60˚F) WB with cooling/heating mixed operation ❇2 Nominal heating conditions Indoor 20˚C (68˚F) DB,Outdoor 7˚C (45˚F) DB/6˚C (43˚F) WB Pipe length 7.5 m (24-9/16 ft), Level difference m (0 ft) ❇3 Height without legs 1650mm (65 in.) ❇4 -5˚C (23˚F) DB/-6˚C (21˚F) WB~21˚C (70˚F) DB/15.5˚C (60˚F) WB with cooling/heating mixed operation Note: ❇1 Nominal cooling conditions Indoor 27˚C (81˚F) DB/19˚C (66˚F) WB, Outdoor 35˚C (95˚F) DB Pipe length 7.5 m (24-9/16 ft), Level difference m (0 ft) Outdoor unit Note: Outdoor Unit Set name PUHY-EP850YSHM-A1(-BS) PUHY-EP900YSHM-A(-BS) Power source 3-phase 4-wire 380-400-415V 50/60Hz ❇1 kW Cooling capacity 96.0 101.0 ❇1 BTU/h (Nominal) 327,600 344,600 Power input kW 23.58 24,87 Current input A 39.8-37.8-36.4 41.9-39.8-38.4 COP (kW/kW) 4.07 4.06 W.B 15~24˚C (59~75˚F) Temp ❇4 Indoor range of Outdoor D.B - 5~43˚C (23~109˚F) cooling ❇2 kW Heating capacity 108.0 113.0 ❇2 BTU/h (Nominal) 368,500 385,600 Power input kW 25.59 27.90 Current input A 43.1-41.0-39.5 47.0-44.7-43.1 COP (kW/kW) 4.22 4.05 Temp ❇4 Indoor temp D.B 15~27˚C (59~81˚F) range Outdoor temp W.B -20~15.5˚C (-4~60˚F) of heating Indoor unit Total capacity 50~130% of outdoor unit capacity connectable Model/Quantity P15~P250 / 1~50 P15~P250 / 1~50 Sound pressure level dB 65 65 (measured in anechoic room) Liquid mm(in.) Diameter of ø19.05 (ø3/4) Brazed ø19.05 (ø3/4) Brazed mm(in.) refrigerant pipe Gas ø41.28 (ø1-5/8) Brazed ø41.28 (ø1-5/8) Brazed Outdoor unit , Outdoor unit , and Outdoor unit PUHY-EP250YHM-A(-BS) PUHY-EP300YHM-A(-BS) PUHY-EP300YHM-A(-BS) PUHY-EP300YHM-A(-BS) PUHY-EP300YHM-A(-BS) PUHY-EP300YHM-A(-BS) Pre-coated galvanized steel sheets (+ powder coating for-BS type) External finish mm 1,710 ✕ 1,220 ✕ 760 1,710 ✕ 1,220 ✕ 760 1,710 ✕ 1,220 ✕ 760 1,710 ✕ 1,220 ✕ 760 1,710 ✕ 1,220 ✕ 760 1,710 ✕ 1,220 ✕ 760 External dimension H ✕ W ✕ D ❇3 in 67-3/8 ✕ 48-1/16 ✕ 29-15/16 67-3/8 ✕ 48-1/16 ✕ 29-15/16 67-3/8 ✕ 48-1/16 ✕ 29-15/16 67-3/8 ✕ 48-1/16 ✕ 29-15/16 67-3/8 ✕ 48-1/16 ✕ 29-15/16 67-3/8 ✕ 48-1/16 ✕ 29-15/16 kg(lbs) 245 (541) 245 (541) 245 (541) 245 (541) Net weight 245 (541) 245 (541) Salt-resistant cross fin & copper tube Heat exchanger Inverter scroll hermetic compressor Type Inverter Compressor Starting method Motor output kW 8.3 8.3 8.3 8.3 6.7 8.3 m /min 225 225 225 225 225 225 Air flow rate L/s 3,750 3,750 3,750 3,750 3,750 3,750 7,945 7,945 7,945 7,945 cfm FAN 7,945 7,945 Type ✕ Quantity Propeller fan ✕ Propeller fan ✕ Propeller fan ✕ Propeller fan ✕ Propeller fan ✕ Propeller fan ✕ Motor output 0.46 ✕ 0.46 ✕ 0.46 ✕ 0.46 ✕ kW 0.46 ✕ 0.46 ✕ High pressure sensor, High pressure switch 4.15 MPa (601 psi) High pressure protection Over-heat protection, Over-current protection Protection Inverter circuit (COMP./FAN) Over-heat protection Compressor R410A ✕ 11.5kg R410A ✕ 11.5kg R410A ✕ 11.5kg R410A ✕ 11.5kg R410A ✕ 11.5kg R410A ✕ 11.5kg Refrigerant Type ✕ Original charge (26 lbs) (26 lbs) (26 lbs) (26 lbs) (26 lbs) (26 lbs) ø12.7 (ø1/2) Brazed ø12.7 (ø1/2) Brazed mm(in.) ø9.52 (ø3/8) Brazed Pipe between Liquid ø22.2 (ø7/8) Brazed mm(in.) unit distributor Gas Outdoor Twinning kit : CMY-Y300VBK2 Optional parts joint : CMY-Y102S / L-G2, CMY-Y202 / 302-G2 Header : CMY-Y104 / 108 / 1010-G Specifications Specifications Set name PUHY-EP750YSHM-A1(-BS) PUHY-EP800YSHM-A(-BS) Power source 3-phase 4-wire 380-400-415V 50/60Hz ❇1 kW Cooling capacity 85.0 90.0 ❇1 BTU/h (Nominal) 290,000 307,100 Power input kW 20.43 22.00 Current input A 34.4-32.7-31.5 37.1-35.2-34.0 COP (kW/kW) 4.16 4.09 W.B 15~24˚C (59~75˚F) Temp ❇4 Indoor range of Outdoor D.B - 5~43˚C (23~109˚F) cooling ❇2 kW Heating capacity 95.0 100.0 ❇2 BTU/h (Nominal) 324,100 341,200 Power input kW 22.19 23.41 Current input A 37.4-35.5-34.3 39.5-37.5-36.1 COP (kW/kW) 4.28 4.27 Temp ❇4 Indoor temp D.B 15~27˚C (59~81˚F) range Outdoor temp W.B -20~15.5˚C (-4~60˚F) of heating Indoor unit Total capacity 50~130% of outdoor unit capacity connectable Model/Quantity P15~P250 / 1~50 P15~P250 / 1~50 Sound pressure level dB 64 64 (measured in anechoic room) Liquid mm(in.) Diameter of ø19.05 (ø3/4) Brazed ø19.05 (ø3/4) Brazed mm(in.) refrigerant pipe Gas ø34.93 (ø1-1/4) Brazed ø34.93 (ø1-3/8) Brazed Outdoor unit , Outdoor unit , and Outdoor unit PUHY-EP200YHM-A(-BS) PUHY-EP250YHM-A(-BS) PUHY-EP300YHM-A(-BS) PUHY-EP200YHM-A(-BS) PUHY-EP300YHM-A(-BS) PUHY-EP300YHM-A(-BS) Pre-coated galvanized steel sheets (+ powder coating for-BS type) External finish mm 1,710 ✕ 1,220 ✕ 760 1,710 ✕ 920 ✕ 760 1,710 ✕ 1,220 ✕ 760 1,710 ✕ 1,220 ✕ 760 1,710 ✕ 920 ✕ 760 1,710 ✕ 1,220 ✕ 760 External dimension H ✕ W ✕ D ❇3 in 67-3/8 ✕ 36-1/4 ✕ 29-15/16 67-3/8 ✕ 48-1/16 ✕ 29-15/16 67-3/8 ✕ 48-1/16 ✕ 29-15/16 67-3/8 ✕ 36-1/4 ✕ 29-15/16 67-3/8 ✕ 48-1/16 ✕ 29-15/16 67-3/8 ✕ 48-1/16 ✕ 29-15/16 kg(lbs) 245 (541) 200 (441) 245 (541) 245 (541) Net weight 200 (441) 245 (541) Salt-resistant cross fin & copper tube Heat exchanger Inverter scroll hermetic compressor Type Inverter Compressor Starting method Motor output kW 8.3 5.4 8.3 8.3 5.4 6.7 m /min 225 185 225 225 185 225 Air flow rate L/s 3,750 3,083 3,750 3,750 3,083 3,750 7,945 6,532 7,945 7,945 cfm FAN 6,532 7,945 Type ✕ Quantity Propeller fan ✕ Propeller fan ✕ Propeller fan ✕ Propeller fan ✕ Propeller fan ✕ Propeller fan ✕ Motor output 0.46 ✕ 0.46 ✕ 0.46 ✕ 0.46 ✕ kW 0.46 ✕ 0.46 ✕ High pressure sensor, High pressure switch 4.15 MPa (601 psi) High pressure protection Over-heat protection, Over-current protection Protection Inverter circuit (COMP./FAN) Over-heat protection Compressor R410A ✕ 11.5kg R410A ✕ 9.0kg R410A ✕ 11.5kg R410A ✕ 11.5kg R410A ✕ 9.0kg R410A ✕ 11.5kg Refrigerant Type ✕ Original charge (26 lbs) (20 lbs) (26 lbs) (26 lbs) (20 lbs) (26 lbs) ø9.52 (ø3/8) Brazed ø12.7 (ø1/2) Brazed ø12.7 (ø1/2) Brazed ø9.52 (ø3/8) Brazed mm(in.) Pipe between Liquid ø22.2 (ø7/8) Brazed mm(in.) ø19.05 (ø3/4) Brazed ø22.2 (ø7/8) Brazed ø22.2 (ø7/8) Brazed ø19.05 (ø3/4) Brazed unit distributor Gas Outdoor Twinning kit : CMY-Y300VBK2 Optional parts joint : CMY-Y102S / L-G2, CMY-Y202 / 302-G2 Header : CMY-Y104 / 108 / 1010-G OUTDOOR UNIT Y Series - High COP PUHY-EP YSHM-A(-BS) OUTDOOR UNIT Y Series - High COP PUHY-EP YSHM-A(-BS) Page112 Pham Van Tung - email: vantung@tle.com.vn - dt: 0985.11.61.62 hoac 0439783799 may le 710 Page113 in mm ø12.7 (ø1/2) Brazed ø22.2 (ø7/8) Brazed ø12.7(ø1/2) Brazed ø19.05(ø3/4) Brazed 59 60 P15 ~ P250 / ~ 43 63.0 215,000 18.04 30.4-28.9-27.8 3.49 56.0 191,100 18.16 30.6-29.1-28.0 3.08 PUHY-HP500YSHM-A(-BS) ø15.88 (ø5/8) Brazed ø15.88 (ø5/8) Brazed ø28.58 (ø1-1/8) Brazed ø28.58 (ø1-1/8) Brazed PUHY-HP200YHM-A(-BS) PUHY-HP200YHM-A(-BS) PUHY-HP250YHM-A(-BS) PUHY-HP250YHM-A(-BS) Pre-coated galvanized steel sheets Pre-coated galvanized steel sheets 1,710 (without legs 1,650) 1,710 (without legs 1,650) 1,710 (without legs 1,650) 1,710 (without legs 1,650) 1,710 (without legs 1,650) ✕ 920 ✕ 760 1,710 (without legs 1,650) ✕ 920 ✕ 760 ✕ 920 ✕ 760 ✕ 920 ✕ 760 ✕ 920 ✕ 760 ✕ 920 ✕ 760 67-3/8 (without legs 65) 67-3/8 (without legs 65) 67-3/8 (without legs 65) 67-3/8 (without legs 65) 67-3/8 (without legs 65) 67-3/8 (without legs 65) ✕ 36-1/4 ✕ 29-15/16 ✕ 36-1/4 ✕ 29-15/16 ✕ 36-1/4 ✕ 29-15/16 ✕ 36-1/4 ✕ 29-15/16 ✕ 36-1/4 ✕ 29-15/16 ✕ 36-1/4 ✕ 29-15/16 220 (486) 220 (486) 220 (486) 220 (486) 220 (486) 220 (486) 57 50 ~ 130% of outdoor unit capacity P15 ~ P250 / ~ 21 P15 ~ P250 / ~ 34 -25 ~ 15.5˚C (-13 ~ 60˚F) 50.0 170,600 13.35 22.5-21.4-20.6 3.74 15 ~ 27˚C (59 ~ 81˚F) 31.5 107,500 8.94 15.0-14.3-13.8 3.52 - ~ 43˚C (23 ~ 109˚F) 56 P15~P250 / 1~17 25.0 85,300 6.52 11.0-10.4-10.0 3.83 22.4 76,400 6.40 10.8-10.2-9.8 3.50 PUHY-HP250YHM-A(-BS) PUHY-HP400YSHM-A(-BS) 3-phase 4-wire 380-400-415V 50/60Hz 28.0 45.0 95,500 153,500 9.06 12.86 15.2-14.5-14.0 21.7-20.6-19.8 3.09 3.49 15 ~ 24˚C (59 ~ 75˚F) ❇3 Extemal static pressure option is available (30Pa, 60Pa/3.1mmH2O, 6.1mmH2O) ❇2 Nominal heating conditions Indoor 20˚C (68˚F) DB,Outdoor 7˚C (45˚F) DB/6˚C (43˚F) WB Pipe length 7.5 m (24-9/16 ft), Level difference m (0 ft) ❇1 Nominal cooling conditions Indoor 27˚C (81˚F) DB/19˚C (66˚F) WB, Outdoor 35˚C (95˚F) DB Pipe length 7.5 m (24-9/16 ft), Level difference m (0 ft) Outdoor unit Note: Net weight kg(lbs) Heat exchanger Salt-resistant cross fin & copper tube Salt-resistant cross fin & copper tube Type Inverter scroll hermetic compressor Inverter scroll hermetic compressor Compressor Starting method Inverter Inverter 5.3 6.7 5.3 5.3 6.7 6.7 Motor output kW 225 225 225 225 225 225 m /min ❇3 3,750 3,750 3,750 3,750 3,750 3,750 Air flow rate L/s 7,945 7,945 7,945 7,945 7,945 7,945 cfm FAN Propeller fan ✕ Propeller fan ✕ Propeller fan ✕ Propeller fan ✕ Propeller fan ✕ Propeller fan ✕ Type ✕ Quantity 0.92 ✕ 0.92 ✕ 0.92 ✕ 0.92 ✕ 0.92 ✕ 0.92 ✕ Motor output kW Pa (0 mmH2O) Pa (0 mmH2O) Pa (0 mmH2O) Pa (0 mmH2O) Pa (0 mmH2O) Pa (0 mmH2O) External static press High pressure protection High pressure sensor, High pressure switch at 4.15 MPa (601 psi) High pressure sensor, High pressure switch at 4.15 MPa (601 psi) Protection Over-heat protection, Over-current protection Over-heat protection, Over-current protection Inverter circuit (COMP./FAN) devices Over-heat protection Over-heat protection Compressor R410A x 9.0kg (20lbs) R410A ✕ 9.0kg (20 lbs) R410A ✕ 9.0kg (20 lbs) R410A ✕ 9.0kg (20 lbs) R410A ✕ 9.0kg (20 lbs) R410A ✕ 9.0kg (20 lbs) Refrigerant Type ✕ Original charge ø9.52 (ø3/8) Flare ø9.52 (ø3/8) Flare ø9.52 (ø3/8) Flare ø9.52 (ø3/8) Flare Pipe between Liquid pipe mm(in.) ø19.05 (ø3/4) Brazed ø19.05 (ø3/4) Brazed ø22.2 (ø7/8) Brazed ø22.2 (ø7/8) Brazed mm(in.) unit distributor Gas pipe Joint : CMY-Y102S-G2 Outdoor Twinning kit : CMY-Y100VBK2 Header : CMY-Y104/108/1010-G Optional parts Joint : CMY-Y102S/L-G2, CMY-Y202-G2 Header : CMY-Y104/108/1010-G External dimension H ✕ W ✕ D Temp range Outdoor W.B of heating Indoor unit Total capacity connectable Model/Quantity Sound pressure level dB (measured in anechoic room) Liquid pipe mm(in.) Diameter of refrigerant pipe Gas pipe mm(in.) Model External finish Power input Current input COP Indoor kW BTU/h kW A kW/kW D.B D.B kW BTU/h kW A kW/kW W.B PUHY-HP200YHM-A(-BS) Note: Indoor: 15.0˚CW.B.~24.0˚CW.B (59~75˚FW.B.) Circulating water: 10.0˚C~45.0˚C (50~113˚F) Indoor: 15.0˚CD.B.~27.0˚CD.B (59~81˚FD.B.) Circulating water: 10.0˚C~45.0˚C (50~113˚F) Indoor: 15.0˚CW.B.~24.0˚CW.B (59~75˚FW.B.) Circulating water: 10.0˚C~45.0˚C (50~113˚F) ❇1 Nominal cooling conditions(subject to JIS B8615-1) Indoor 27˚CDB/19˚CWB(81˚FDB/66˚FWB), Water temperature 30˚C(86˚F) Pipe length 7.5m(24-9/16ft.), Level difference:0m(0ft.) ❇2 Nominal heating conditions(subject to JIS B8615-1) Indoor 20˚CDB(68˚FDB), Water temperature 20˚C(68˚F) Pipe length 7.5m(24-9/16ft.), Level difference:0m(0ft.) Operating temperature range Indoor: 15.0˚CD.B.~27.0˚CD.B (59~81˚FD.B.) Circulating water: 10.0˚C~45.0˚C (50~113˚F) Indoor: 15.0˚CW.B.~24.0˚CW.B (59~75˚FW.B.) Circulating water: 10.0˚C~45.0˚C (50~113˚F) Outdoor Unit Indoor: 15.0˚CD.B.~27.0˚CD.B (59~81˚FD.B.) Circulating water: 10.0˚C~45.0˚C (50~113˚F) PQHY-P300YHM-A PQHY-P250YHM-A Cooling Heating Cooling Heating 28.0 31.5 33.5 37.5 ❇1 kW Capacity 95,500 107,500 114,300 128,000 ❇2 BTU/h Power source 3-phase 4-wire 380-400-415V 50/60Hz 3.92 4.12 5.45 5.80 7.36 8.15 kW Power input 6.6/6.2/6.0 6.9/6.6/6.3 9.2/8.7/8.4 9.7/9.3/8.9 12.4/11.8/11.3 13.7/13.0/12.5 A Current 5.71 6.06 5.13 5.43 4.55 4.60 kW/kW COP Type Inverter scroll hermetic compressor Compressor Motor output kW 6.3 4.6 7.4 Type Plate type Heat 5.0 exchanger Water volume in plate 5.0 5.0 m /h 5.76 5.76 5.76 Circulating Volume cfm 3.4 3.4 3.4 water Pressure drop kPa 17 17 17 R410A / MEL32 Refrigerant / Lubricant R410A / MEL32 R410A / MEL32 Acrylic painted steel plate External finish 1,160 (45-11/16) (1,100 (43-5/16) without legs) 1,160 (45-11/16) (1,100 (43-5/16) without legs) 1,160 (45-11/16) (1,100 (43-5/16) without legs) External dimension H x W x D mm(in.) ✕ 880 (34-11/16) ✕ 550 (21-11/16) ✕ 880 (34-11/16) ✕ 550 (21-11/16) ✕ 880 (34-11/16) ✕ 550 (21-11/16) High pressure protection 4.15MPa 4.15 MPa 4.15MPa Protection Compressor Over-heat protection devices Inverter Over-heat protection, Over-current protection Liquid pipe mm(in.) ø9.52 (ø3/8) Brazed (ø12.7 (ø1/2) Brazed,total length>=90m (295ft)) ø9.52 (ø3/8) Brazed (ø12.7 (ø1/2) Brazed,total length>=40m (131ft)) Refrigerant ø9.52 (ø3/8) Brazed mm(in.) ø22.2 (ø7/8) Brazed piping diameter Gas pipe ø22.2 (ø7/8) Brazed ø19.05 (ø3/4) Brazed Total capacity 50~130 % of heat source unit capacity 50~130 % of heat source unit capacity 50~130 % of heat source unit capacity Indoor unit Model / Quantity P15~P250 / 1~21 P15~P250 / 1~26 P15~P250 / 1~17 Sound pressure level dB 49 50 47 (measured in anechoic room) kg(lbs) 195 (430) Net weight 195 (430) 195 (430) PQHY-P200YHM-A Cooling Heating 22.4 25.0 76,400 85,300 Specifications Specifications Set name Power source ❇1 Cooling capacity ❇1 (Nominal) Power input Current input COP Indoor Temp range of Outdoor cooling ❇2 Heating capacity ❇2 (Nominal) HEAT SOURCE UNIT WY (Heat Pump) Series PQHY-P YHM-A OUTDOOR UNIT ZUBADAN (Heat Pump) Series(Y) PUHY-HP Y(S)HM-A(-BS) Page114 Pham Van Tung - email: vantung@tle.com.vn - dt: 0985.11.61.62 hoac 0439783799 may le 710 Page115 ❇1 ❇2 kW BTU/h 5.0 5.0 R410A / MEL32 Indoor: 15.0˚CW.B.~24.0˚CW.B (59~75˚FW.B.) Circulating water: 10.0˚C~45.0˚C (50~113˚F) R410A / MEL32 Indoor: 15.0˚CD.B.~27.0˚CD.B (59~81˚FD.B ) Circulating water: 10.0˚C~45.0˚C (50~113˚F) 50 17 17 50~130 % of heat source unit capacity P15~P250 / 1~34 4.6 4.6 5.76 + 5.76 3.4 + 3.4 8.25 8.65 13.9/13.2/12.7 14.6/13.8/13.3 5.45 5.78 ø12.7 (ø1/2) Brazed ø28.58 (ø1-1/8) Brazed PQHY-P200YHM-A PQHY-P200YHM-A Indoor: 15.0˚CW.B.~24.0˚CW.B (59~75˚FW.B.) Circulating water: 10.0˚C~45.0˚C (50~113˚F) Indoor: 15.0˚CD.B.~27.0˚CD.B (59~81˚FD.B ) Circulating water: 10.0˚C~45.0˚C (50~113˚F) 51 PQHY-P450YSHM-A Heating Cooling 56.0 50.0 191,100 170,600 3-phase 4-wire 380-400-415V 50/60Hz 10.42 9.84 17.5/16.7/16.1 16.6/15.7/15.2 5.37 5.08 ø15.88 (ø5/8) Brazed ø28.58 (ø1-1/8) Brazed PQHY-P250YHM-A PQHY-P200YHM-A Inverter scroll hermetic compressor 6.3 4.6 Plate type 5.0 5.0 5.76 + 5.76 3.4 + 3.4 17 17 50~130 % of heat source unit capacity P15~P250 / 1~39 ❇1 Nominal cooling conditions(subject to JIS B8615-1) Indoor 27˚CDB/19˚CWB(81˚FDB/66˚FWB), Water temperature 30˚C(86˚F) Pipe length 7.5m(24-9/16ft.), Level difference:0m(0ft.) ❇2 Nominal heating conditions(subject to JIS B8615-1) Indoor 20˚CDB(68˚FDB), Water temperature 20˚C(68˚F) Pipe length 7.5m(24-9/16ft.), Level difference:0m(0ft.) Outdoor unit Note: Refrigerant / Lubricant External finish R410A / MEL32 R410A / MEL32 Acrylic painted steel plate 1,160 (45-11/16) 1,160 (45-11/16) 1,160 (45-11/16) 1,160 (45-11/16) External dimension mm (in.) (1,100 (43-5/16) without legs) (1,100 (43-5/16) without legs) (1,100 (43-5/16) without legs) (1,100 (43-5/16) without legs) HxWxD ✕ 880 (34-11/16) ✕ 550 (21-11/16) ✕ 880 (34-11/16) ✕ 550 (21-11/16) ✕ 880 (34-11/16) ✕ 550 (21-11/16) ✕ 880 (34-11/16) ✕ 550 (21-11/16) 4.15MPa 4.15MPa 4.15MPa 4.15MPa High pressure protection Protection Over-heat protection Compressor devices Over-heat protection, Over-current protection Inverter Pipe between unit Liquid pipe mm (in.) ø9.52 (ø3/8) Brazed ø9.52 (ø3/8) Brazed ø9.52 (ø3/8) Brazed ø9.52 (ø3/8) Brazed mm (in.) ø19.05 (ø3/4) Brazed ø19.05 (ø3/4) Brazed ø22.2 (ø7/8) Brazed ø22.2 (ø7/8) Brazed and distributor Gas pipe 195 (430) 195 (430) 195 (430) 195 (430) kg (lbs) Net weight Operating temperature range Power source Power input kW Current A COP kW/kW Liquid pipe mm (in.) Refrigerant piping diameter Gas pipe mm (in.) Model Type Compressor Motor output kW Type Heat exchanger Water volume in plate m3/h Circulating Volume cfm water Pressure drop kPa Total capacity Indoor unit Model / Quantity Sound pressure level dB (measured in anechoic room) Capacity PQHY-P400YSHM-A Cooling Heating 45.0 50.0 153,500 170,600 5.76 + 5.76 3.4 + 3.4 5.0 6.3 R410A / MEL32 Indoor: 15.0˚CD.B.~27.0˚CD.B (59~81˚FD.B ) Circulating water: 10.0˚C~45.0˚C (50~113˚F) ø9.52 (ø3/8) Brazed ø22.2 (ø7/8) Brazed 195 (430) ø9.52 (ø3/8) Brazed ø22.2 (ø7/8) Brazed 195 (430) 1,160 (45-11/16) 1,160 (45-11/16) (1,100 (43-5/16) without legs) (1,100 (43-5/16) without legs) ✕ 880 (34-11/16) ✕ 550 (21-11/16) ✕ 880 (34-11/16) ✕ 550 (21-11/16) 4.15MPa 4.15MPa R410A / MEL32 Indoor: 15.0˚CW.B.~24.0˚CW.B (59~75˚FW.B.) Circulating water: 10.0˚C~45.0˚C (50~113˚F) 52 17 17 50~130 % of heat source unit capacity P15~P250 / 1~43 5.0 6.3 12.06 11.45 20.3/19.3/18.6 19.3/18.3/17.6 5.22 4.89 ø15.88 (ø5/8) Brazed ø28.58 (ø1-1/8) Brazed PQHY-P250YHM-A PQHY-P250YHM-A PQHY-P500YSHM-A Heating Cooling 63.0 56.0 215,000 191,100 ❇1 ❇2 kW BTU/h R410A / MEL32 Indoor: 15.0˚CW.B.~24.0˚CW.B (59~75˚FW.B.) Circulating water: 10.0˚C~45.0˚C (50~113˚F) Note: ❇1 Nominal cooling conditions(subject to JIS B8615-1) Indoor 27˚CDB/19˚CWB(81˚FDB/66˚FWB), Water temperature 30˚C(86˚F) Pipe length 7.5m(24-9/16ft.), Level difference:0m(0ft.) ❇2 Nominal heating conditions(subject to JIS B8615-1) Indoor 20˚CDB(68˚FDB), Water temperature 20˚C(68˚F) Pipe length 7.5m(24-9/16ft.), Level difference:0m(0ft.) Outdoor Unit ø12.7 (ø1/2) Brazed ø22.2 (ø7/8) Brazed 195 (430) 1,160 (45-11/16) (1,100 (43-5/16) without legs) ✕ 880 (34-11/16) ✕ 550 (21-11/16) 4.15MPa R410A / MEL32 Indoor: 15.0˚CD.B.~27.0˚CD.B (59~81˚FD.B ) Circulating water: 10.0˚C~45.0˚C (50~113˚F) 53 Indoor: 15.0˚CW.B.~24.0˚CW.B (59~75˚FW.B.) Circulating water: 10.0˚C~45.0˚C (50~113˚F) R410A / MEL32 R410A / MEL32 Acrylic painted steel plate 1,160 (45-11/16) 1,160 (45-11/16) (1,100 (43-5/16) without legs) (1,100 (43-5/16) without legs) ✕ 880 (34-11/16)✕ 550 (21-11/16) ✕ 880 (34-11/16) ✕ 550 (21-11/16) 4.15MPa 4.15MPa Over-heat protection Over-heat protection, Over-current protection ø12.7 (ø1/2) Brazed ø12.7 (ø1/2) Brazed ø22.2 (ø7/8) Brazed ø22.2 (ø7/8) Brazed 195 (430) 195 (430) Indoor: 15.0˚CD.B.~27.0˚CD.B (59~81˚FD.B ) Circulating water: 10.0˚C~45.0˚C (50~113˚F) 52.5 PQHY-P550YSHM-A PQHY-P600YSHM-A Heating Cooling Heating 76.5 69.0 69.0 261,000 235,400 235,400 3-phase 4-wire 380-400-415V 50/60Hz 13.46 17.12 14.65 15.48 22.7/21.5/20.8 28.9/27.4/26.4 24.7/23.4/22.6 26.1/24.8/23.9 4.68 4.46 4.45 4.70 ø15.88 (ø5/8) Brazed ø15.88 (ø5/8) Brazed ø28.58 (ø1-1/8) Brazed ø28.58 (ø1-1/8) Brazed PQHY-P300YHM-A PQHY-P300YHM-A PQHY-P300YHM-A PQHY-P250YHM-A Inverter scroll hermetic compressor 7.4 7.4 6.3 7.4 Plate type 5.0 5.0 5.0 5.0 5.76 + 5.76 5.76 + 5.76 3.4 + 3.4 3.4 + 3.4 17 17 17 17 50~130 % of heat source unit capacity 50~130 % of heat source unit capacity P15~P250 / 2~47 P15~P250 / 2~50 Cooling 63.0 215,000 1,160 (45-11/16) mm (in.) (1,100 (43-5/16) without legs) ✕ 880 (34-11/16) ✕ 550 (21-11/16) 4.15MPa High pressure protection Protection Compressor devices Inverter ø12.7 (ø1/2) Brazed Pipe between unit Liquid pipe mm (in.) ø22.2 (ø7/8) Brazed mm (in.) and distributor Gas pipe 195 (430) kg (lbs) Net weight External dimension HxWxD Refrigerant / Lubricant External finish Operating temperature range Power source Power input kW Current A COP kW/kW Liquid pipe mm (in.) Refrigerant piping diameter Gas pipe mm (in.) Model Type Compressor Motor output kW Type Heat exchanger Water volume in plate m3/h Circulating Volume cfm water Pressure drop kPa Total capacity Indoor unit Model / Quantity Sound pressure level dB (measured in anechoic room) Capacity Set name Specifications Specifications Set name HEAT SOURCE UNIT WY (Heat Pump) Series PQHY-P YSHM-A HEAT SOURCE UNIT WY (Heat Pump) Series PQHY-P YSHM-A Page116 Pham Van Tung - email: vantung@tle.com.vn - dt: 0985.11.61.62 hoac 0439783799 may le 710 Page117 ❇1 Nominal cooling conditions Indoor 27˚C (81˚F) DB/19˚C (66˚F) WB, Outdoor 35˚C (95˚F) DB Pipe length 7.5 m (24-9/16 ft), Level difference m (0 ft) ❇2 Nominal heating conditions Indoor 20˚C (68˚F) DB,Outdoor 7˚C (45˚F) DB/6˚C (43˚F) WB Pipe length 7.5 m (24-9/16 ft), Level difference m (0 ft) ❇3 -5˚C (23˚F) DB/-6˚C (21˚F) WB~21˚C (70˚F) DB/15.5˚C (60˚F) WB with cooling/heating mixed operation ❇2 Nominal heating conditions Indoor 20˚C (68˚F) DB,Outdoor 7˚C (45˚F) DB/6˚C (43˚F) WB Pipe length 7.5 m (24-9/16 ft), Level difference m (0 ft) ❇3 -5˚C (23˚F) DB/-6˚C (21˚F) WB~21˚C (70˚F) DB/15.5˚C (60˚F) WB with cooling/heating mixed operation Note: ❇1 Nominal cooling conditions Indoor 27˚C (81˚F) DB/19˚C (66˚F) WB, Outdoor 35˚C (95˚F) DB Pipe length 7.5 m (24-9/16 ft), Level difference m (0 ft) Outdoor unit Note: 61 60 50.0 170,600 13.71 23.1-21.9-21.1 3.64 45.0 153,500 13.74 23.1-22.0-21.2 3.27 PURY-P400YHM-A(-BS) P15 ~ P250 / ~ 40 50 ~ 150% of outdoor unit capacity -20 ~ 15.5˚C (-4 ~ 60˚F) 15 ~ 27˚C (59 ~ 81˚F) - ~ 43˚C (23 ~ 109˚F) 15 ~ 24˚C (59 ~ 75˚F) 3-phase 4-wire 380-400-415V 50/60Hz P15 ~ P250 / ~ 35 45.0 153,500 12.47 21.0-19.9-19.2 3.60 40.0 136,500 12.47 21.0-19.9-19.2 3.20 PURY-P350YHM-A(-BS) Outdoor Unit ø19.05 (ø3/4) Brazed ø22.2 (ø7/8) Brazed ø28.58 (ø1-1/8) Brazed ø28.58 (ø1-1/8) Brazed Pre-coated galvanized steel sheet (+powder coating for -BS type) 1,710 (1,650 without legs) ✕ 1,220 ✕ 760 1,710 (1,650 without legs) ✕ 1,220 ✕ 760 67-3/8 (65 without legs) ✕ 48-1/16 ✕ 29-15/16 67-3/8 (65 without legs) ✕ 48-1/16 ✕ 29-15/16 265 (584) 265 (584) Salt-resistant cross fin & copper tube Inverter scroll hermetic compressor Type Compressor Starting method Inverter 10.3 10.5 kW Motor output 225 225 m /min 3,750 3,750 L/s Air flow rate 7,945 7,945 FAN cfm Propeller fan ✕ Propeller fan ✕ Type ✕ Quantity 0.92 0.92 kW Motor output High pressure sensor, High pressure switch 4.15 MPa (601 psi) High pressure protection Protection Inverter circuit (COMP./FAN) Over-heat protection, Over-current protection Over-heat protection Compressor R410A ✕ 11.8kg (26 lbs) R410A ✕ 11.8kg (26 lbs) Refrigerant Type ✕ Original charge joint : CMY-Y102S-G2, CMY-Y102L-G2, CMY-Y202-G2, CMY-R160-J joint : CMY-Y102S-G2, CMY-Y102L-G2, CMY-Y202-G2, CMY-R160-J BC controller : CMB-P104, 105, 106, 108, 1010, 1013, 1016V-G Main BC controller : CMB-P108, 1010, 1013, 1016V-GA Optional parts Main BC controller : CMB-P108, 1010, 1013, 1016V-GA Sub BC controller : CMB-P104, 108V-GB, CMB-P1016V-HB Sub BC controller : CMB-P104, 108V-GB, CMB-P1016V-HB Power source ❇1 kW Cooling capacity ❇1 BTU/h (Nominal) kW Power input A Current input COP (kW/kW) W.B Temp ❇3 Indoor range of D.B Outdoor cooling ❇2 kW Heating capacity ❇2 BTU/h (Nominal) kW Power input A Current input COP (kW/kW) Temp ❇3 Indoor temp D.B range Outdoor temp W.B of heating Indoor unit Total capacity connectable Model/Quantity Sound pressure level dB (measured in anechoic room) Diameter of High pressure mm(in.) refrigerant pipe Low pressure mm(in.) External finish mm External dimension H ✕ W ✕ D in Net weight kg (lbs) Heat exchanger Specifications Specifications PURY-P200YHM-A(-BS) PURY-P250YHM-A(-BS) PURY-P300YHM-A(-BS) 3-phase 4-wire 380-400-415V 50/60Hz Power source ❇1 22.4 28.0 kW Cooling capacity 33.5 ❇1 BTU/h 76,400 95,500 (Nominal) 114,300 5.77 7.73 Power input kW 9.25 9.7-9.2-8.9 13.0-12.3-11.9 Current input A 15.6-14.8-14.2 3.88 3.62 COP (kW/kW) 3.62 W.B 15 ~ 24˚C (59 ~ 75˚F) Temp ❇3 Indoor range of Outdoor D.B - ~ 43˚C (23 ~ 109˚F) cooling ❇2 25.0 31.5 kW Heating capacity 37.5 ❇2 BTU/h 85,300 107,500 (Nominal) 128,000 6.14 7.83 Power input kW 9.58 10.3-9.8-9.4 13.2-12.5-12.1 Current input A 16.1-15.3-14.8 4.07 4.02 COP (kW/kW) 3.91 15 ~ 27˚C (59 ~ 81˚F) Temp ❇3 Indoor temp D.B range Outdoor temp W.B -20 ~ 15.5˚C (-4 ~ 60˚F) of heating 50 ~ 150% of outdoor unit capacity Indoor unit Total capacity P15 ~ P250 / ~ 20 P15 ~ P250 / ~ 25 connectable Model/Quantity P15 ~ P250 / ~ 30 Sound pressure level 56 57 dB 59 (measured in anechoic room) ø15.88 (ø5/8) Brazed ø19.05 (ø3/4) Brazed High pressure mm(in.) Diameter of ø19.05 (ø3/4) Brazed ø19.05 (ø3/4) Brazed ø22.2 (ø7/8) Brazed refrigerant pipe Low pressure mm(in.) ø22.2 (ø7/8) Brazed Pre-coated galvanized steel sheet (+powder coating for -BS type) External finish 1,710 (1,650 without legs) ✕ 920 ✕ 760 1,710 (1,650 without legs) ✕ 920 ✕ 760 mm 1,710 (1,650 without legs) ✕ 920 ✕ 760 External dimension H ✕ W ✕ D 67-3/8 (65 without legs) ✕ 36-1/4 ✕ 29-15/16 67-3/8 (65 without legs) ✕ 36-1/4 ✕ 29-15/16 67-3/8 (65 without legs) ✕ 36-1/4 ✕ 29-15/16 in 220 (485) 235 (518) Net weight kg (lbs) 240 (529) Heat exchanger Salt-resistant cross fin & copper tube Type Inverter scroll hermetic compressor Compressor Starting method Inverter 5.4 6.7 Motor output kW 8.2 185 185 m /min 185 3,083 3,083 Air flow rate L/s 3,083 6,532 6,532 FAN cfm 6,532 Propeller fan ✕ Propeller fan ✕ Type ✕ Quantity Propeller fan ✕ 0.92 0.92 Motor output kW 0.92 High pressure protection High pressure sensor, High pressure switch 4.15 MPa (601 psi) Protection Inverter circuit (COMP./FAN) Over-heat protection, Over-current protection Compressor Over-heat protection R410A ✕ 8.0kg (18 lbs) R410A ✕ 10.5kg (24 lbs) Refrigerant Type ✕ Original charge R410A ✕ 10.5kg (24 lbs) joint : CMY-Y102S-G2, CMY-Y102L-G2, CMY-R160-J joint : CMY-Y102S-G2, CMY-Y102L-G2, CMY-Y202-G2, CMY-R160-J BC controller : CMB-P104, 105, 106, 108, 1010, 1013, 1016V-G BC controller : CMB-P104, 105, 106, 108, 1010, 1013, 1016V-G Optional parts Main BC controller : CMB-P108, 1010, 1013, 1016V-GA Main BC controller : CMB-P108, 1010, 1013, 1016V-GA Sub BC controller : CMB-P104, 108V-GB, CMB-P1016V-HB Sub BC controller : CMB-P104, 108V-GB, CMB-P1016V-HB OUTDOOR UNIT R2 Series PURY-P YHM-A(-BS) OUTDOOR UNIT R2 Series PURY-P YHM-A(-BS) Page118 Pham Van Tung - email: vantung@tle.com.vn - dt: 0985.11.61.62 hoac 0439783799 may le 710 Page119 61 76.5 261,000 20.83 35.1-33.4-32.1 3.67 69.0 235,400 19.64 33.1-31.4-30.3 3.51 PURY-P600YSHM-A(-BS) 62 ❇2 Nominal heating conditions Indoor 20˚C (68˚F) DB,Outdoor 7˚C (45˚F) DB/6˚C (43˚F) WB Pipe length 7.5 m (24-9/16 ft), Level difference m (0 ft) ❇3 -5˚C (23˚F) DB/-6˚C (21˚F) WB~21˚C (70˚F) DB/15.5˚C (60˚F) WB with cooling/heating mixed operation ❇3 -5˚C (23˚F) DB/-6˚C (21˚F) WB~21˚C (70˚F) DB/15.5˚C (60˚F) WB with cooling/heating mixed operation Outdoor Twinning kit : CMY-R100VBK joint : CMY-Y102S-G2, CMY-Y102L-G2, CMY-Y202-G2, CMY-R160-J Main BC controller : CMB-P108, 1010, 1013, 1016V-GA Sub BC controller : CMB-P104, 108V-GB, CMB-P1016V-HB ❇2 Nominal heating conditions Indoor 20˚C (68˚F) DB,Outdoor 7˚C (45˚F) DB/6˚C (43˚F) WB Pipe length 7.5 m (24-9/16 ft), Level difference m (0 ft) R410A ✕ 10.5kg (24 lbs) 6.7 185 3,083 6,532 Propeller fan ✕ 0.92 Salt-resistant cross fin & copper tube Inverter scroll hermetic compressor Inverter 8.2 8.2 185 185 3,083 3,083 6,532 6,532 Propeller fan ✕ Propeller fan ✕ 0.92 0.92 High pressure sensor, High pressure switch 4.15 MPa (601 psi) Over-heat protection, Over-current protection Over-heat protection R410A ✕ 10.5kg (24 lbs) R410A ✕ 10.5kg (24 lbs) ø19.05 (ø3/4) Brazed ø22.2 (ø7/8) Brazed Outdoor Unit R410A ✕ 10.5kg (24 lbs) 8.2 185 3,083 6,532 Propeller fan ✕ 0.92 ø28.58 (ø1-1/8) Brazed ø28.58 (ø1-1/8) Brazed PURY-P250YHM-A(-BS) PURY-P300YHM-A(-BS) PURY-P300YHM-A(-BS) PURY-P300YHM-A(-BS) Pre-coated galvanized steel sheets (+ powder coating for-BS type) 1,710(1,650 without legs) ✕ 920 ✕ 760 1,710(1,650 without legs) ✕ 920 ✕ 760 1,710(1,650 without legs) ✕ 920 ✕ 760 1,710(1,650 without legs) ✕ 920 ✕ 760 67-3/8(65 without legs) ✕ 36-1/4 ✕ 29-15/16 67-3/8(65 without legs) ✕ 36-1/4 ✕ 29-15/16 67-3/8(65 without legs) ✕ 36-1/4 ✕ 29-15/16 67-3/8(65 without legs) ✕ 36-1/4 ✕ 29-15/16 235 (518) 240 (529) 240 (529) 240 (529) ø28.58 (ø1-1/8) Brazed ø28.58 (ø1-1/8) Brazed ❇1 Nominal cooling conditions Indoor 27˚C (81˚F) DB/19˚C (66˚F) WB, Outdoor 35˚C (95˚F) DB Pipe length 7.5 m (24-9/16 ft), Level difference m (0 ft) Note: Optional parts m /min Air flow rate L/s FAN cfm Type ✕ Quantity Motor output kW High pressure protection Protection Inverter circuit (COMP./FAN) Compressor Refrigerant Type ✕ Original charge Pipe between High pressure mm(in.) unit distributor Low pressure mm(in.) -20 ~ 15.5˚C (-4 ~ 60˚F) 15 ~ 27˚C (59 ~ 81˚F) - ~ 43˚C (23 ~ 109˚F) 15 ~ 24˚C (59 ~ 75˚F) 3-phase 4-wire 380-400-415V 50/60Hz 50 ~ 150% of outdoor unit capacity P15 ~ P250 / ~ 50 (Connectable branch pipe number is max 48.) 69.0 235,400 18.81 31.7-30.1-29.0 3.66 63.0 215,000 18.68 31.5-29.9-28.8 3.37 PURY-P550YSHM-A(-BS) ❇1 Nominal cooling conditions Indoor 27˚C (81˚F) DB/19˚C (66˚F) WB, Outdoor 35˚C (95˚F) DB Pipe length 7.5 m (24-9/16 ft), Level difference m (0 ft) Outdoor unit Note: mm in kg(lbs) Net weight Heat exchanger Type Compressor Starting method Motor output kW External dimension H ✕ W ✕ D Power input kW Current input A COP (kW/kW) Temp ❇3 Indoor temp D.B range Outdoor temp W.B of heating Indoor unit Total capacity connectable Model/Quantity Sound pressure level dB (measured in anechoic room) High pressure mm(in.) Diameter of refrigerant pipe Low pressure mm(in.) Model External finish Set name Power source ❇1 Cooling capacity kW ❇1 BTU/h (Nominal) Power input kW Current input A COP (kW/kW) Temp ❇3 Indoor W.B range of Outdoor D.B cooling ❇2 Heating capacity kW ❇2 BTU/h (Nominal) Specifications Specifications Set name PURY-P450YSHM-A(-BS) PURY-P500YSHM-A(-BS) Power source 3-phase 4-wire 380-400-415V 50/60Hz ❇1 kW 50.0 56.0 Cooling capacity ❇1 BTU/h 170,600 191,100 (Nominal) Power input kW 14.14 16.75 Current input A 23.8-22.6-21.8 28.2-26.8-25.8 COP (kW/kW) 3.53 3.34 15 ~ 24˚C (59 ~ 75˚F) W.B Temp ❇3 Indoor range of - ~ 43˚C (23 ~ 109˚F) Outdoor D.B cooling ❇2 kW 56.0 63.0 Heating capacity ❇2 BTU/h 191,100 215,000 (Nominal) Power input kW 14.71 16.79 Current input A 24.8-23.5-22.7 28.3-26.9-25.9 COP (kW/kW) 3.80 3.75 Temp ❇3 Indoor temp D.B 15 ~ 27˚C (59 ~ 81˚F) range Outdoor temp W.B -20 ~ 15.5˚C (-4 ~ 60˚F) of heating Indoor unit Total capacity 50 ~ 150% of outdoor unit capacity P15 ~ P250 / ~ 45 P15 ~ P250 / ~ 50 (Connectable branch pipe number is max 48.) connectable Model/Quantity Sound pressure level dB 60 60 (measured in anechoic room) High pressure mm(in.) ø22.2 (ø7/8) Brazed ø22.2 (ø7/8) Brazed Diameter of ø28.58 (ø1-1/8) Brazed ø28.58 (ø1-1/8) Brazed refrigerant pipe Low pressure mm(in.) Model PURY-P200YHM-A(-BS) PURY-P250YHM-A(-BS) PURY-P250YHM-A(-BS) PURY-P250YHM-A(-BS) External finish Pre-coated galvanized steel sheets (+ powder coating for-BS type) 1,710(1,650 without legs) ✕ 920 ✕ 760 1,710(1,650 without legs) ✕ 920 ✕ 760 1,710(1,650 without legs) ✕ 920 ✕ 760 1,710(1,650 without legs) ✕ 920 ✕ 760 mm External dimension H ✕ W ✕ D 67-3/8(65 without legs) ✕ 36-1/4 ✕ 29-15/16 67-3/8(65 without legs) ✕ 36-1/4 ✕ 29-15/16 67-3/8(65 without legs) ✕ 36-1/4 ✕ 29-15/16 67-3/8(65 without legs) ✕ 36-1/4 ✕ 29-15/16 in 220 (485) 235 (518) 235 (518) 235 (518) kg(lbs) Net weight Heat exchanger Salt-resistant cross fin & copper tube Type Inverter scroll hermetic compressor Compressor Starting method Inverter Motor output 5.4 6.7 6.7 6.7 kW 185 185 185 185 m /min Air flow rate 3,083 3,083 3,083 3,083 L/s 6,532 6,532 6,532 6,532 cfm FAN Type ✕ Quantity Propeller fan ✕ Propeller fan ✕ Propeller fan ✕ Propeller fan ✕ Motor output 0.92 0.92 0.92 0.92 kW High pressure protection High pressure sensor, High pressure switch 4.15 MPa (601 psi) Over-heat protection, Over-current protection Protection Inverter circuit (COMP./FAN) Compressor Over-heat protection R410A ✕ 8.0kg (18 lbs) R410A ✕ 10.5kg (24 lbs) R410A ✕ 10.5kg (24 lbs) R410A ✕ 10.5kg (24 lbs) Refrigerant Type ✕ Original charge ø15.88 (ø5/8) Brazed ø19.05 (ø3/4) Brazed Pipe between High pressure mm(in.) ø19.05 (ø3/4) Brazed ø22.2 (ø7/8) Brazed unit distributor Low pressure mm(in.) Outdoor Twinning kit : CMY-R100VBK joint : CMY-Y102S-G2, CMY-Y102L-G2, CMY-Y202-G2, CMY-R160-J Optional parts Main BC controller : CMB-P108, 1010, 1013, 1016V-GA Sub BC controller : CMB-P104, 108V-GB, CMB-P1016V-HB OUTDOOR UNIT R2 Series PURY-P YSHM-A(-BS) OUTDOOR UNIT R2 Series PURY-P YSHM-A(-BS) Page120 Pham Van Tung - email: vantung@tle.com.vn - dt: 0985.11.61.62 hoac 0439783799 may le 710 Page121 ❇1 Nominal cooling conditions Indoor 27˚C (81˚F) DB/19˚C (66˚F) WB, Outdoor 35˚C (95˚F) DB Pipe length 7.5 m (24-9/16 ft), Level difference m (0 ft) ❇2 Nominal heating conditions Indoor 20˚C (68˚F) DB,Outdoor 7˚C (45˚F) DB/6˚C (43˚F) WB Pipe length 7.5 m (24-9/16 ft), Level difference m (0 ft) ❇3 -5˚C (23˚F) DB/-6˚C (21˚F) WB~21˚C (70˚F) DB/15.5˚C (60˚F) WB with cooling/heating mixed operation ❇2 Nominal heating conditions Indoor 20˚C (68˚F) DB,Outdoor 7˚C (45˚F) DB/6˚C (43˚F) WB Pipe length 7.5 m (24-9/16 ft), Level difference m (0 ft) ❇3 -5˚C (23˚F) DB/-6˚C (21˚F) WB~21˚C (70˚F) DB/15.5˚C (60˚F) WB with cooling/heating mixed operation Note: ❇1 Nominal cooling conditions Indoor 27˚C (81˚F) DB/19˚C (66˚F) WB, Outdoor 35˚C (95˚F) DB Pipe length 7.5 m (24-9/16 ft), Level difference m (0 ft) Outdoor unit Note: Outdoor Unit Set name PURY-P750YSHM-A(-BS) PURY-P800YSHM-A(-BS) Power source 3-phase 4-wire 380-400-415V 50/60Hz ❇1 kW 85.0 90.0 Cooling capacity ❇1 BTU/h 290,000 307,100 (Nominal) Power input kW 27.86 29.75 Current input A 47.0-44.6-43.0 50.2-47.7-45.9 COP (kW/kW) 3.05 3.02 15 ~ 24˚C (59 ~ 75˚F) W.B Temp ❇3 Indoor range of - ~ 43˚C (23 ~ 109˚F) Outdoor D.B cooling ❇2 kW 95.0 100.0 Heating capacity ❇2 BTU/h 324,100 341,200 (Nominal) Power input kW 26.36 27.64 Current input A 44.4-42.2-40.7 46.6-44.3-42.7 COP (kW/kW) 3.60 3.61 15 ~ 27˚C (59 ~ 81˚F) Temp ❇3 Indoor temp D.B range Outdoor temp W.B -20 ~ 15.5˚C (-4 ~ 60˚F) of heating 50 ~ 150% of outdoor unit capacity Indoor unit Total capacity P15 ~ P250 / ~ 50 (Connectable branch pipe number is max 48.) connectable Model/Quantity Sound pressure level dB 63.5 64 (measured in anechoic room) High pressure mm(in.) ø28.58 (ø1-1/8) Brazed ø28.58 (ø1-1/8) Brazed Diameter of ø34.93 (ø1-3/8) Brazed ø34.93 (ø1-3/8) Brazed refrigerant pipe Low pressure mm(in.) PURY-P350YHM-A(-BS) PURY-P400YHM-A(-BS) PURY-P400YHM-A(-BS) PURY-P400YHM-A(-BS) Model External finish Pre-coated galvanized steel sheets (+ powder coating for-BS type) 1,710(1,650 without legs) ✕ 1,220 ✕ 760 1,710(1,650 without legs) ✕ 1,220 ✕ 760 1,710(1,650 without legs) ✕ 1,220 ✕ 760 1,710(1,650 without legs) ✕ 1,220 ✕ 760 mm External dimension H ✕ W ✕ D 67-3/8(65 without legs) ✕ 48-1/16 ✕ 29-15/16 67-3/8(65 without legs) ✕ 48-1/16 ✕ 29-15/16 67-3/8(65 without legs) ✕ 48-1/16 ✕ 29-15/16 67-3/8(65 without legs) ✕ 48-1/16 ✕ 29-15/16 in 265 (584) 265 (584) 265 (584) 265 (584) kg(lbs) Net weight Heat exchanger Salt-resistant cross fin & copper tube Type Inverter scroll hermetic compressor Compressor Starting method Inverter Motor output 10.3 10.5 10.5 10.5 kW 225 225 225 225 m /min Air flow rate 3,750 3,750 3,750 3,750 L/s 7,945 7,945 7,945 7,945 cfm FAN Type ✕ Quantity Propeller fan ✕ Propeller fan ✕ Propeller fan ✕ Propeller fan ✕ Motor output 0.92 0.92 0.92 0.92 kW High pressure protection High pressure sensor, High pressure switch 4.15 MPa (601 psi) Over-heat protection, Over-current protection Protection Inverter circuit (COMP./FAN) Compressor Over-heat protection R410A ✕ 11.8kg (26 lbs) R410A ✕ 11.8kg (26 lbs) R410A ✕ 11.8kg (26 lbs) R410A ✕ 11.8kg (26 lbs) Refrigerant Type ✕ Original charge ø22.2 (ø7/8) Brazed ø19.05 (ø3/4) Brazed ø22.2 (ø7/8) Brazed Pipe between High pressure mm(in.) ø28.58 (ø1-1/8) Brazed ø28.58 (ø1-1/8) Brazed ø28.58 (ø1-1/8) Brazed unit distributor Low pressure mm(in.) Outdoor Twinning kit : CMY-R200VBK joint : CMY-Y102S-G2, CMY-Y102L-G2, CMY-Y202-G2, CMY-R160-J Optional parts Main BC controller : CMB-P1016V-HA Sub BC controller : CMB-P104, 108V-GB, CMB-P1016V-HB Specifications Specifications Set name PURY-P650YSHM-A(-BS) PURY-P700YSHM-A(-BS) Power source 3-phase 4-wire 380-400-415V 50/60Hz ❇1 kW 73.0 80.0 Cooling capacity ❇1 BTU/h 249,100 273,000 (Nominal) kW Power input 22.80 24.72 A Current input 38.4-36.5-35.2 41.7-39.6-38.2 3.20 COP (kW/kW) 3.23 15 ~ 24˚C (59 ~ 75˚F) W.B Temp ❇3 Indoor range of - ~ 43˚C (23 ~ 109˚F) D.B Outdoor cooling ❇2 kW 81.5 88.0 Heating capacity ❇2 BTU/h 278,100 300,300 (Nominal) kW 22.55 24.30 Power input A 38.0-36.1-34.8 41.0-38.9-37.5 Current input 3.61 3.62 COP (kW/kW) 15 ~ 27˚C (59 ~ 81˚F) Temp ❇3 Indoor temp D.B W.B range Outdoor temp -20 ~ 15.5˚C (-4 ~ 60˚F) of heating 50 ~ 150% of outdoor unit capacity Indoor unit Total capacity P15 ~ P250 / ~ 50 (Connectable branch pipe number is max 48.) connectable Model/Quantity Sound pressure level dB 62.5 63 (measured in anechoic room) High pressure mm(in.) ø28.58 (ø1-1/8) Brazed ø28.58 (ø1-1/8) Brazed Diameter of ø28.58 (ø1-1/8) Brazed ø34.93 (ø1-3/8) Brazed refrigerant pipe Low pressure mm(in.) PURY-P300YHM-A(-BS) PURY-P350YHM-A(-BS) PURY-P300YHM-A(-BS) PURY-P400YHM-A(-BS) Model External finish Pre-coated galvanized steel sheets (+ powder coating for-BS type) 1,710(1,650 without legs) ✕ 920 ✕ 760 1,710(1,650 without legs) ✕ 1,220 ✕ 760 1,710(1,650 without legs) ✕ 920 ✕ 760 1,710(1,650 without legs) ✕ 1,220 ✕ 760 mm External dimension H ✕ W ✕ D 67-3/8(65 without legs) ✕ 36-1/4 ✕ 29-15/16 67-3/8(65 without legs) ✕ 48-1/16 ✕ 29-15/16 67-3/8(65 without legs) ✕ 36-1/4 ✕ 29-15/16 67-3/8(65 without legs) ✕ 48-1/16 ✕ 29-15/16 in 240 (529) 265 (584) 240 (529) 265 (584) kg(lbs) Net weight Heat exchanger Salt-resistant cross fin & copper tube Type Inverter scroll hermetic compressor Compressor Starting method Inverter 8.2 10.3 8.2 10.5 Motor output kW 185 225 185 225 m /min 3,083 3,750 3,083 3,750 Air flow rate L/s 6,532 7,945 6,532 7,945 cfm FAN Propeller fan ✕ Propeller fan ✕ Propeller fan ✕ Propeller fan ✕ Type ✕ Quantity 0.92 0.92 0.92 0.92 Motor output kW High pressure sensor, High pressure switch 4.15 MPa (601 psi) High pressure protection Over-heat protection, Over-current protection Protection Inverter circuit (COMP./FAN) Over-heat protection Compressor R410A ✕ 10.5kg (24 lbs) R410A ✕ 11.8kg (26 lbs) R410A ✕ 10.5kg (24 lbs) R410A ✕ 11.8kg (26 lbs) Refrigerant Type ✕ Original charge ø19.05 (ø3/4) Brazed ø19.05 (ø3/4) Brazed ø19.05 (ø3/4) Brazed ø22.2 (ø7/8) Brazed Pipe between High pressure mm(in.) ø22.2 (ø7/8) Brazed ø28.58 (ø1-1/8) Brazed ø22.2 (ø7/8) Brazed ø28.58 (ø1-1/8) Brazed unit distributor Low pressure mm(in.) Outdoor Twinning kit : CMY-R200VBK Outdoor Twinning kit : CMY-R100VBK joint : CMY-Y102S-G2, CMY-Y102L-G2, CMY-Y202-G2, CMY-R160-J joint : CMY-Y102S-G2, CMY-Y102L-G2, CMY-Y202-G2, CMY-R160-J Optional parts Main BC controller : CMB-P108, 1010, 1013, 1016V-GA Main BC controller : CMB-P1016V-HA Sub BC controller : CMB-P104, 108V-GB, CMB-P1016V-HB Sub BC controller : CMB-P104, 108V-GB, CMB-P1016V-HB OUTDOOR UNIT R2 Series PURY-P YSHM-A(-BS) OUTDOOR UNIT R2 Series PURY-P YSHM-A(-BS) Page122 Pham Van Tung - email: vantung@tle.com.vn - dt: 0985.11.61.62 hoac 0439783799 may le 710 Page123 ø15.88 (ø5/8) Brazed ø19.05 (ø3/4) Brazed ø19.05 (ø3/4) Brazed ø22.2 (ø7/8) Brazed 60 P15 ~ P250 / ~ 30 ❇2 Nominal heating conditions Indoor 20˚C (68˚F) DB,Outdoor 7˚C (45˚F) DB/6˚C (43˚F) WB Pipe length 7.5 m (24-9/16 ft), Level difference m (0 ft) ❇3 -5˚C (23˚F) DB/-6˚C (21˚F) WB~21˚C (70˚F) DB/15.5˚C (60˚F) WB with cooling/heating mixed operation ❇2 Nominal heating conditions Indoor 20˚C (68˚F) DB,Outdoor 7˚C (45˚F) DB/6˚C (43˚F) WB Pipe length 7.5 m (24-9/16 ft), Level difference m (0 ft) ❇3 -5˚C (23˚F) DB/-6˚C (21˚F) WB~21˚C (70˚F) DB/15.5˚C (60˚F) WB with cooling/heating mixed operation Outdoor Twinning kit : CMY-R100VBK joint : CMY-Y102S-G2, CMY-Y102L-G2, CMY-Y202-G2, CMY-R160-J Main BC controller : CMB-P108, 1010, 1013, 1016V-GA Sub BC controller : CMB-P104, 108V-GB, CMB-P1016V-HB 5.4 5.4 185 185 3,083 3,083 6,532 6,532 Propeller fan ✕ Propeller fan ✕ 0.92 0.92 High pressure sensor, High pressure switch 4.15 MPa (601 psi) Over-heat protection, Over-current protection Over-heat protection R410A ✕ 10.5kg (24 lbs) R410A ✕ 10.5kg (24 lbs) ø15.88 (ø5/8) Brazed ø19.05 (ø3/4) Brazed Salt-resistant cross fin & copper tube Inverter scroll hermetic compressor Inverter Outdoor Unit PURY-EP200YHM-A(-BS) PURY-EP200YHM-A(-BS) Pre-coated galvanized steel sheets (+ powder coating for-BS type) 1,710(1,650 without legs) ✕ 920 ✕ 760 1,710(1,650 without legs) ✕ 920 ✕ 760 67-3/8(65 without legs) ✕ 36-1/4 ✕ 29-15/16 67-3/8(65 without legs) ✕ 36-1/4 ✕ 29-15/16 235 (518) 235 (518) ø22.2 (ø7/8) Brazed ø28.58 (ø1-1/8) Brazed 60 50 ~ 150% of outdoor unit capacity P15 ~ P250 / ~40 -20 ~ 15.5˚C (-4 ~ 60˚F) 50.0 170,600 11.73 19.8-18.8-18.1 4.26 15 ~ 27˚C (59 ~ 81˚F) - ~ 43˚C (23 ~ 109˚F) PURY-EP400YSHM-A(-BS) 3-phase 4-wire 380-400-415V 50/60Hz 45.0 153,500 10.57 17.8-16.9-16.3 4.25 15 ~ 24˚C (59 ~ 75˚F) ❇1 Nominal cooling conditions Indoor 27˚C (81˚F) DB/19˚C (66˚F) WB, Outdoor 35˚C (95˚F) DB Pipe length 7.5 m (24-9/16 ft), Level difference m (0 ft) Note: Optional parts Set name Power source ❇1 Cooling capacity kW ❇1 BTU/h (Nominal) Power input kW Current input A COP (kW/kW) Temp ❇3 Indoor W.B range of Outdoor D.B cooling ❇2 Heating capacity kW ❇2 BTU/h (Nominal) Power input kW Current input A COP (kW/kW) Temp ❇3 Indoor temp D.B range Outdoor temp W.B of heating Indoor unit Total capacity connectable Model/Quantity Sound pressure level dB (measured in anechoic room) High pressure mm(in.) Diameter of refrigerant pipe Low pressure mm(in.) Model External finish mm External dimension H ✕ W ✕ D in Net weight kg(lbs) Heat exchanger Type Compressor Starting method Motor output kW m /min Air flow rate L/s FAN cfm Type ✕ Quantity Motor output kW High pressure protection Protection Inverter circuit (COMP./FAN) Compressor Refrigerant Type ✕ Original charge Pipe between High pressure mm(in.) unit distributor Low pressure mm(in.) ❇1 Nominal cooling conditions Indoor 27˚C (81˚F) DB/19˚C (66˚F) WB, Outdoor 35˚C (95˚F) DB Pipe length 7.5 m (24-9/16 ft), Level difference m (0 ft) Outdoor unit Note: Optional parts ø19.05 (ø3/4) Brazed ø22.2 (ø7/8) Brazed 57 37.5 128,000 9.37 15.8-15.0-14.4 4.00 33.5 114,300 8.33 14.0-13.3-12.8 4.02 PURY-EP300YHM-A(-BS) Pre-coated galvanized steel sheets (+ powder coating for-BS type) 1,710(1,650 without legs) ✕ 920 ✕ 760 1,710(1,650 without legs) ✕ 1,220 ✕ 760 1,710 (1,650 without legs) ✕ 1,220 ✕ 760 67-3/8(65 without legs) ✕ 36-1/4 ✕ 29-15/16 67-3/8(65 without legs) ✕ 48-1/16 ✕ 29-15/16 67-3/8 (65 without legs) ✕ 48-1/16 ✕ 29-15/16 235 (518) 265 (584) 265 (584) Salt-resistant cross fin & copper tube Inverter scroll hermetic compressor Inverter 5.4 8.0 6.7 185 225 225 3,083 3,750 3,750 6,532 7,945 7,945 Propeller fan ✕ Propeller fan ✕ Propeller fan ✕ 0.92 0.92 0.92 High pressure sensor, High pressure switch 4.15 MPa (601 psi) Over-heat protection, Over-current protection Over-heat protection R410A ✕ 10.5kg (24 lbs) R410A ✕ 11.8kg (26 lbs) R410A ✕ 11.8kg (26lbs) joint : CMY-Y102S-G2, CMY-Y102L-G2, CMY-R160-J BC controller : CMB-P104, 105, 106, 108, 1010, 1013, 1016V-G Main BC controller : CMB-P108, 1010, 1013, 1016V-GA Sub BC controller : CMB-P104, 108V-GB, CMB-P1016V-HB 60 P15 ~ P250 / ~ 20 -20 ~ 15.5˚C (-4 ~ 60˚F) 31.5 107,500 7.60 12.8-12.1-11.7 4.14 15 ~ 27˚C (59 ~ 81˚F) - ~ 43˚C (23 ~ 109˚F) PURY-EP250YHM-A(-BS) 3-phase 4-wire 380-400-415V 50/60Hz 28.0 95,500 6.86 11.5-11.0-10.6 4.08 15 ~ 24˚C (59 ~ 75˚F) 50 ~ 150% of outdoor unit capacity P15~P250 / 1~25 25.0 85,300 5.81 9.8-9.3-8.9 4.30 22.4 76,400 5.23 8.8-8.3-8.0 4.28 PURY-EP200YHM-A(-BS) Specifications Specifications Power source ❇1 kW Cooling capacity ❇1 BTU/h (Nominal) kW Power input A Current input COP (kW/kW) W.B Temp ❇3 Indoor range of D.B Outdoor cooling ❇2 kW Heating capacity ❇2 BTU/h (Nominal) kW Power input A Current input COP (kW/kW) Temp ❇3 Indoor temp D.B range Outdoor temp W.B of heating Indoor unit Total capacity connectable Model/Quantity Sound pressure level dB (measured in anechoic room) Diameter of High pressure mm(in.) refrigerant pipe Low pressure mm(in.) External finish mm External dimension H ✕ W ✕ D in kg(lbs) Net weight Heat exchanger Type Compressor Starting method kW Motor output m /min L/s Air flow rate cfm FAN Type ✕ Quantity kW Motor output High pressure protection Protection Inverter circuit (COMP./FAN) Compressor Refrigerant Type ✕ Original charge OUTDOOR UNIT R2 Series - High COP PURY-EP YSHM-A(-BS) OUTDOOR UNIT R2 Series - High COP PURY-EP YHM-A(-BS) Page124 Pham Van Tung - email: vantung@tle.com.vn - dt: 0985.11.61.62 hoac 0439783799 may le 710 Page125 62 P15 ~ P250 / ~ 45 56.0 191,100 13.23 22.3-21.2-20.4 4.23 50.0 170,600 12.07 20.3-19.3-18.6 4.14 63.0 215,000 15.33 25.8-24.5-23.6 4.10 56.0 191,100 13.70 23.1-21.9-21.1 4.08 PURY-EP500YSHM-A(-BS) 62 50 ~ 150% of outdoor unit capacity P15 ~ P250 / ~ 50 (Connectable branch pipe number is max 48.) -20 ~ 15.5˚C (-4 ~ 60˚F) 15 ~ 27˚C (59 ~ 81˚F) - ~ 43˚C (23 ~ 109˚F) 15 ~ 24˚C (59 ~ 75˚F) 3-phase 4-wire 380-400-415V 50/60Hz ❇3 -5˚C (23˚F) DB/-6˚C (21˚F) WB~21˚C (70˚F) DB/15.5˚C (60˚F) WB with cooling/heating mixed operation ❇2 Nominal heating conditions Indoor 20˚C (68˚F) DB,Outdoor 7˚C (45˚F) DB/6˚C (43˚F) WB Pipe length 7.5 m (24-9/16 ft), Level difference m (0 ft) ❇1 Nominal cooling conditions Indoor 27˚C (81˚F) DB/19˚C (66˚F) WB, Outdoor 35˚C (95˚F) DB Pipe length 7.5 m (24-9/16 ft), Level difference m (0 ft) Outdoor unit Note: ø22.2 (ø7/8) Brazed ø22.2 (ø7/8) Brazed ø28.58 (ø1-1/8) Brazed ø28.58 (ø1-1/8) Brazed PURY-EP200YHM-A(-BS) PURY-EP250YHM-A(-BS) PURY-EP200YHM-A(-BS) PURY-EP300YHM-A(-BS) Pre-coated galvanized steel sheets (+ powder coating for-BS type) 1,710(1,650 without legs) ✕ 920 ✕ 760 1,710(1,650 without legs) ✕ 1,220 ✕ 760 1,710(1,650 without legs) ✕ 920 ✕ 760 1,710(1,650 without legs) ✕ 1,220 ✕ 760 mm External dimension H ✕ W ✕ D 67-3/8(65 without legs) ✕ 36-1/4 ✕ 29-15/16 67-3/8(65 without legs) ✕ 48-1/16 ✕ 29-15/16 67-3/8(65 without legs) ✕ 36-1/4 ✕ 29-15/16 67-3/8(65 without legs) ✕ 48-1/16 ✕ 29-15/16 in Net weight 235 (518) 265 (584) 265 (584) 235 (518) kg(lbs) Heat exchanger Salt-resistant cross fin & copper tube Inverter scroll hermetic compressor Type Compressor Starting method Inverter 5.4 8.0 6.7 5.4 Motor output kW 185 225 225 185 m /min 3,083 3,750 3,750 3,083 Air flow rate L/s FAN 6,532 7,945 7,945 6,532 cfm Propeller fan ✕ Propeller fan ✕ Propeller fan ✕ Propeller fan ✕ Type ✕ Quantity 0.92 0.92 0.92 0.92 Motor output kW High pressure sensor, High pressure switch 4.15 MPa (601 psi) High pressure protection Over-heat protection, Over-current protection Protection Inverter circuit (COMP./FAN) Over-heat protection Compressor Auto-defrost mode (Reversed refrigerant circle) Defrosting method Refrigerant Type ✕ Original charge R410A ✕ 10.5kg (24 lbs) R410A ✕ 11.8kg (26 lbs) R410A ✕ 11.8kg (26 lbs) R410A ✕ 10.5kg (24 lbs) ø15.88 (ø5/8) Brazed Pipe between High pressure mm(in.) ø19.05 (ø3/4) Brazed ø15.88 (ø5/8) Brazed ø19.05 (ø3/4) Brazed unit distributor Low pressure mm(in.) ø22.2 (ø7/8) Brazed ø19.05 (ø3/4) Brazed Outdoor Twinning kit : CMY-R100VBK joint : CMY-Y102S-G2, CMY-Y102L-G2, CMY-Y202-G2, CMY-R160-J Optional parts Main BC controller : CMB-P108, 1010, 1013, 1016V-GA Sub BC controller : CMB-P104, 108V-GB, CMB-P1016V-HB Power input kW Current input A COP (kW/kW) Temp ❇3 Indoor temp D.B range Outdoor temp W.B of heating Indoor unit Total capacity connectable Model/Quantity Sound pressure level dB (measured in anechoic room) Diameter of High pressure mm(in.) refrigerant pipe Low pressure mm(in.) Model External finish kW BTU/h Power input kW Current input A COP (kW/kW) Temp ❇3 Indoor W.B range of Outdoor D.B cooling ❇2 Heating capacity kW ❇2 BTU/h (Nominal) ❇1 ❇1 PURY-EP450YSHM-A1(-BS) 69.0 235,400 16.95 28.6-27.1-26.2 4.07 63.0 215,000 15.47 26.1-24.8-23.9 4.07 PURY-EP550YSHM-A1(-BS) - ~ 43˚C (23 ~ 109˚F) 15 ~ 24˚C (59 ~ 75˚F) 3-phase 4-wire 380-400-415V 50/60Hz 76.5 261,000 19.12 32.2-30.6-29.5 4.00 69.0 235,400 17.00 28.6-27.2-26.2 4.05 PURY-EP600YSHM-A(-BS) Note: Outdoor Twinning kit : CMY-R100VBK joint : CMY-Y102S-G2, CMY-Y102L-G2, CMY-Y202-G2, CMY-R160-J Main BC controller : CMB-P108, 1010, 1013, 1016V-GA Sub BC controller : CMB-P104, 108V-GB, CMB-P1016V-HB ❇3 -5˚C (23˚F) DB/-6˚C (21˚F) WB~21˚C (70˚F) DB/15.5˚C (60˚F) WB with cooling/heating mixed operation ❇2 Nominal heating conditions Indoor 20˚C (68˚F) DB,Outdoor 7˚C (45˚F) DB/6˚C (43˚F) WB Pipe length 7.5 m (24-9/16 ft), Level difference m (0 ft) ❇1 Nominal cooling conditions Indoor 27˚C (81˚F) DB/19˚C (66˚F) WB, Outdoor 35˚C (95˚F) DB Pipe length 7.5 m (24-9/16 ft), Level difference m (0 ft) Optional parts Outdoor Unit Power input kW Current input A COP (kW/kW) Temp ❇3 Indoor temp D.B 15 ~ 27˚C (59 ~ 81˚F) range -20 ~ 15.5˚C (-4 ~ 60˚F) Outdoor temp W.B of heating Indoor unit Total capacity 50 ~ 150% of outdoor unit capacity P15 ~ P250 / ~ 50 (Connectable branch pipe number is max 48.) P15 ~ P250 / ~ 50 (Connectable branch pipe number is max 48.) connectable Model/Quantity Sound pressure level 63 63 dB (measured in anechoic room) ø28.58 (ø1-1/8) Brazed ø28.58 (ø1-1/8) Brazed Diameter of High pressure mm(in.) ø28.58 (ø1-1/8) Brazed ø28.58 (ø1-1/8) Brazed refrigerant pipe Low pressure mm(in.) Model PURY-EP250YHM-A(-BS) PURY-EP300YHM-A(-BS) PURY-EP300YHM-A(-BS) PURY-EP300YHM-A(-BS) External finish Pre-coated galvanized steel sheets (+ powder coating for-BS type) 1,710(1,650 without legs) ✕ 1,220 ✕ 760 1,710(1,650 without legs) ✕ 1,220 ✕ 760 1,710(1,650 without legs) ✕ 1,220 ✕ 760 1,710(1,650 without legs) ✕ 1,220 ✕ 760 mm External dimension H ✕ W ✕ D 67-3/8(65 without legs) ✕ 48-1/16 ✕ 29-15/16 67-3/8(65 without legs) ✕ 48-1/16 ✕ 29-15/16 67-3/8(65 without legs) ✕ 48-1/16 ✕ 29-15/16 67-3/8(65 without legs) ✕ 48-1/16 ✕ 29-15/16 in Net weight 265 (584) 265 (584) 265 (584) 265 (584) kg(lbs) Heat exchanger Salt-resistant cross fin & copper tube Inverter scroll hermetic compressor Type Compressor Starting method Inverter 8.0 8.0 8.0 6.7 Motor output kW 225 225 225 225 m /min 3,750 3,750 3,750 3,750 Air flow rate L/s FAN 7,945 7,945 7,945 7,945 cfm Propeller fan ✕ Propeller fan ✕ Propeller fan ✕ Propeller fan ✕ Type ✕ Quantity 0.92 0.92 0.92 0.92 Motor output kW High pressure sensor, High pressure switch 4.15 MPa (601 psi) High pressure protection Over-heat protection, Over-current protection Protection Inverter circuit (COMP./FAN) Over-heat protection Compressor Auto-defrost mode (Reversed refrigerant circle) Defrosting method Refrigerant Type ✕ Original charge R410A ✕ 11.8kg (26 lbs) R410A ✕ 11.8kg (26 lbs) R410A ✕ 11.8kg (26 lbs) R410A ✕ 11.8kg (26 lbs) ø19.05 (ø3/4) Brazed Pipe between High pressure mm(in.) ø22.2 (ø7/8) Brazed unit distributor Low pressure mm(in.) ❇1 ❇1 kW BTU/h Power input kW Current input A COP (kW/kW) Temp ❇3 Indoor W.B range of Outdoor D.B cooling ❇2 Heating capacity kW ❇2 BTU/h (Nominal) Set name Power source Cooling capacity (Nominal) Specifications Specifications Set name Power source Cooling capacity (Nominal) OUTDOOR UNIT R2 Series - High COP PURY-EP YSHM-A(-BS) OUTDOOR UNIT R2 Series - High COP PURY-EP YSHM-A(-BS) Page126 Pham Van Tung - email: vantung@tle.com.vn - dt: 0985.11.61.62 hoac 0439783799 may le 710 Page127 Indoor: 15.0˚CW.B.~24.0˚CW.B (59~75˚FW.B.) Circulating water: 10.0˚C~45.0˚C (50~113˚F) Indoor: 15.0˚CD.B.~27.0˚CD.B (59~81˚FD.B.) Circulating water: 10.0˚C~45.0˚C (50~113˚F) Indoor: 15.0˚CW.B.~24.0˚CW.B (59~75˚FW.B.) Circulating water: 10.0˚C~45.0˚C (50~113˚F) ❇1 Nominal cooling conditions(subject to JIS B8615-1) Indoor 27˚CDB/19˚CWB(81˚FDB/66˚FWB), Water temperature 30˚C(86˚F) Pipe length 7.5m(24-9/16ft.), Level difference:0m(0ft.) ❇2 Nominal heating conditions(subject to JIS B8615-1) Indoor 20˚CDB(68˚FDB), Water temperature 20˚C(68˚F) Pipe length 7.5m(24-9/16ft.), Level difference:0m(0ft.) Outdoor unit Note: Operating temperature range Indoor: 15.0˚CD.B.~27.0˚CD.B (59~81˚FD.B.) Circulating water: 10.0˚C~45.0˚C (50~113˚F) Indoor: 15.0˚CW.B.~24.0˚CW.B (59~75˚FW.B.) Circulating water: 10.0˚C~45.0˚C (50~113˚F) Indoor: 15.0˚CD.B.~27.0˚CD.B (59~81˚FD.B.) Circulating water: 10.0˚C~45.0˚C (50~113˚F) PQRY-P300YHM-A PQRY-P250YHM-A Cooling Heating Cooling Heating 28.0 31.5 33.5 37.5 ❇1 kW Capacity 95,500 107,500 114,300 128,000 ❇2 BTU/h Power source 3-phase 4-wire 380-400-415V 50/60Hz Power input 3.96 4.12 5.51 5.80 7.44 8.15 kW Current 6.6/6.3/6.1 6.9/6.6/6.3 9.3/8.8/8.5 9.7/9.3/8.9 12.5/11.9/11.5 13.7/13.0/12.5 A COP 5.65 6.06 5.08 5.43 4.50 4.60 kW/kW Type Inverter scroll hermetic compressor Compressor Motor output kW 6.3 4.6 7.4 Heat Type Plate type exchanger Water volume in plate 5.0 5.0 5.0 m /h 5.76 5.76 5.76 Circulating Volume cfm 3.4 3.4 3.4 water Pressure drop kPa 17 17 17 Refrigerant / Lubricant R410A / MEL32 R410A / MEL32 R410A / MEL32 External finish Acrylic painted steel plate 1,160 (45-11/16) (1,100 (43-5/16) without legs) 1,160 (45-11/16) (1,100 (43-5/16) without legs) 1,160 (45-11/16) (1,100 (43-5/16) without legs) External dimension H x W x D mm(in.) ✕ 880 (34-11/16) ✕ 550 (21-11/16) ✕ 880 (34-11/16) ✕ 550 (21-11/16) ✕ 880 (34-11/16) ✕ 550 (21-11/16) High pressure protection 4.15MPa 4.15 MPa 4.15MPa Protection Compressor Over-heat protection devices Inverter Over-heat protection, Over-current protection Refrigerant High press pipe mm(in.) ø19.05 (ø3/4) Brazed ø15.88 (ø5/8) Brazed ø19.05 (ø3/4) Brazed piping diameter Low press pipe mm(in.) ø22.2 (ø7/8) Brazed ø19.05 (ø3/4) Brazed ø22.2 (ø7/8) Brazed Total capacity 50~150 % of heat source unit capacity 50~150 % of heat source unit capacity 50~150 % of heat source unit capacity Indoor unit Model / Quantity P15~P250 / 1~25 P15~P250 / 1~20 P15~P250 / 1~30 Sound pressure level dB 49 47 50 (measured in anechoic room) Net weight kg(lbs) 181 (400) 181 (400) 181 (400) ❇1 ❇2 kW BTU/h mm (in.) Note: 5.0 5.0 R410A / MEL32 Indoor: 15.0˚CD.B.~27.0˚CD.B (59~81˚FD.B ) Circulating water: 10.0˚C~45.0˚C (50~113˚F) Indoor: 15.0˚CW.B.~24.0˚CW.B (59~75˚FW.B ) Circulating water: 10.0˚C~45.0˚C (50~113˚F) Indoor: 15.0˚CD.B.~27.0˚CD.B (59~81˚FD.B ) Circulating water: 10.0˚C~45.0˚C (50~113˚F) 51 PQRY-P450YSHM-A Heating Cooling 56.0 50.0 191,100 170,600 3-phase 4-wire 380-400-415V 50/60Hz 10.42 9.94 17.5/16.7/16.1 16.7/15.9/15.3 5.37 5.03 ø22.2 (ø7/8) Brazed ø28.58 (ø1-1/8) Brazed PQRY-P250YHM-A PQRY-P200YHM-A Inverter scroll hermetic compressor 4.6 6.3 Plate type 5.0 5.0 5.76 + 5.76 3.4 + 3.4 17 17 50~150 % of heat source unit capacity P15~P250 / 1~45 R410A / MEL32 R410A / MEL32 Acrylic painted steel plate 1,160 (45-11/16) 1,160 (45-11/16) 1,160 (45-11/16) 1,160 (45-11/16) (1,100 (43-5/16) without legs) (1,100 (43-5/16) without legs) (1,100 (43-5/16) without legs) (1,100 (43-5/16) without legs) ✕ 880 (34-11/16) ✕ 550 (21-11/16) ✕ 880 (34-11/16) ✕ 550 (21-11/16) ✕ 880 (34-11/16) ✕ 550 (21-11/16) ✕ 880 (34-11/16) ✕ 550 (21-11/16) 4.15MPa 4.15MPa 4.15MPa 4.15MPa Over-heat protection Over-heat protection, Over-current protection ø19.05 (ø3/4) Brazed ø19.05 (ø3/4) Brazed ø19.05 (ø3/4) Brazed ø19.05 (ø3/4) Brazed ø22.2 (ø7/8) Brazed ø22.2 (ø7/8) Brazed 181 (400) 181 (400) 181 (400) 181 (400) R410A / MEL32 Indoor: 15.0˚CW.B.~24.0˚CW.B (59~75˚FW.B ) Circulating water: 10.0˚C~45.0˚C (50~113˚F) 50 17 17 50~150 % of heat source unit capacity P15~P250 / 1~40 4.6 4.6 5.76 + 5.76 3.4 + 3.4 8.32 8.65 14.0/13.3/12.8 14.6/13.8/13.3 5.40 5.78 ø22.2 (ø7/8) Brazed ø28.58 (ø1-1/8) Brazed PQRY-P200YHM-A PQRY-P200YHM-A PQRY-P400YSHM-A Cooling Heating 45.0 50.0 153,500 170,600 ❇1 Nominal cooling conditions(subject to JIS B8615-1) Indoor 27˚CDB/19˚CWB(81˚FDB/66˚FWB), Water temperature 30˚C(86˚F) Pipe length 7.5m(24-9/16ft.), Level difference:0m(0ft.) ❇2 Nominal heating conditions(subject to JIS B8615-1) Indoor 20˚CDB(68˚FDB), Water temperature 20˚C(68˚F) Pipe length 7.5m(24-9/16ft.), Level difference:0m(0ft.) High pressure protection Compressor Inverter Pipe between unit High press pipe mm (in.) and distributor Low press pipe mm (in.) kg (lbs) Net weight Protection devices External dimension HxWxD Refrigerant / Lubricant External finish Operating temperature range Power source Power input kW Current A COP kW/kW High press pipe mm (in.) Refrigerant piping diameter Low press pipe mm (in.) Model Type Compressor Motor output kW Type Heat exchanger Water volume in plate m3/h Circulating Volume cfm water Pressure drop kPa Total capacity Indoor unit Model / Quantity Sound pressure level dB (measured in anechoic room) Capacity Set name Specifications Specifications PQRY-P200YHM-A Cooling Heating 22.4 25.0 76,400 85,300 HEAT SOURCE UNIT WR2 (Heat Recovery) Series PQRY-P YSHM-A HEAT SOURCE UNIT WR2 (Heat Recovery) Series PQRY-P YHM-A 5.76 + 5.76 3.4 + 3.4 5.0 6.3 IR410A / MEL32 Indoor: 15.0˚CD.B.~27.0˚CD.B (59~81˚FD.B ) Circulating water: 10.0˚C~45.0˚C (50~113˚F) Outdoor Unit ø19.05 (ø3/4) Brazed ø19.05 (ø3/4) Brazed ø22.2 (ø7/8) Brazed 181 (400) 181 (400) 1,160 (45-11/16) 1,160 (45-11/16) (1,100 (43-5/16) without legs) (1,100 (43-5/16) without legs) ✕ 880 (34-11/16) ✕ 550 (21-11/16) ✕ 880 (34-11/16) ✕ 550 (21-11/16) 4.15MPa 4.15MPa R410A / MEL32 Indoor: 15.0˚CW.B.~24.0˚CW.B (59~75˚FW.B ) Circulating water: 10.0˚C~45.0˚C (50~113˚F) 52 17 17 50~150 % of heat source unit capacity P15~P250 / 1~50 (Connectable branch pipe number is max 48.) 5.0 6.3 12.06 11.57 20.3/19.3/18.6 19.5/18.5/17.8 5.22 4.84 ø22.2 (ø7/8) Brazed ø28.58 (ø1-1/8) Brazed PQRY-P250YHM-A PQRY-P250YHM-A PQRY-P500YSHM-A Heating Cooling 63.0 56.0 215,000 191,100 Page128 Pham Van Tung - email: vantung@tle.com.vn - dt: 0985.11.61.62 hoac 0439783799 may le 710 Page129 ❇1 ❇2 kW BTU/h R410A / MEL32 Indoor: 15.0˚CW.B~24.0˚CW.B (59~75˚FW.B) Circulating water: 10.0˚C~45.0˚C (50~113˚F) Indoor: 15.0˚CD.B.~27.0˚CD.B (59~81˚FD.B ) Circulating water: 10.0˚C~45.0˚C (50~113˚F) 52.5 PQRY-P550YSHM-A Indoor: 15.0˚CW.B~24.0˚CW.B (59~75˚FW.B) Circulating water: 10.0˚C~45.0˚C (50~113˚F) Indoor: 15.0˚CD.B.~27.0˚CD.B (59~81˚FD.B ) Circulating water: 10.0˚C~45.0˚C (50~113˚F) 53 PQRY-P600YSHM-A Heating Cooling Heating 76.5 69.0 69.0 261,000 235,400 235,400 3-phase 4-wire 380-400-415V 50/60Hz 13.60 17.12 15.62 14.65 22.9/21.8/21.0 28.9/27.4/26.4 26.3/25.0/24.1 24.7/23.4/22.6 4.63 4.46 4.41 4.70 ø28.58 (ø1-1/8) Brazed ø28.58 (ø1-1/8) Brazed ø28.58 (ø1-1/8) Brazed ø28.58 (ø1-1/8) Brazed PQRY-P300YHM-A PQRY-P300YHM-A PQRY-P300YHM-A PQRY-P250YHM-A Inverter scroll hermetic compressor 7.4 7.4 7.4 6.3 Plate type 5.0 5.0 5.0 5.0 5.76 + 5.76 5.76 + 5.76 3.4 + 3.4 3.4 + 3.4 17 17 17 17 50~150 % of heat source unit capacity 50~150 % of heat source unit capacity P15~P250 / 2~50 (Connectable branch pipe number is max 48.) P15~P250 / 2~50 (Connectable branch pipe number is max 48.) Cooling 63.0 215,000 ❇1 Nominal cooling conditions(subject to JIS B8615-1) Indoor 27˚CDB/19˚CWB(81˚FDB/66˚FWB), Water temperature 30˚C(86˚F) Pipe length 7.5m(24-9/16ft.), Level difference:0m(0ft.) ❇2 Nominal heating conditions(subject to JIS B8615-1) Indoor 20˚CDB(68˚FDB), Water temperature 20˚C(68˚F) Pipe length 7.5m(24-9/16ft.), Level difference:0m(0ft.) Outdoor unit Note: R410A / MEL32 R410A / MEL32 R410A / MEL32 Acrylic painted steel plate 1,160 (45-11/16) 1,160 (45-11/16) 1,160 (45-11/16) 1,160 (45-11/16) External dimension mm (in.) (1,100 (43-5/16) without legs) (1,100 (43-5/16) without legs) (1,100 (43-5/16) without legs) (1,100 (43-5/16) without legs) HxWxD ✕ 880 (34-11/16) ✕ 550 (21-11/16) ✕ 880 (34-11/16) ✕ 550 (21-11/16) ✕ 880 (34-11/16) ✕ 550 (21-11/16) ✕ 880 (34-11/16) ✕ 550 (21-11/16) High pressure protection 4.15MPa 4.15MPa 4.15MPa 4.15MPa Protection Over-heat protection Compressor devices Over-heat protection, Over-current protection Inverter Pipe between unit High press pipe mm (in.) ø19.05 (ø3/4) Brazed ø19.05 (ø3/4) Brazed ø19.05 (ø3/4) Brazed ø19.05 (ø3/4) Brazed and distributor ø22.2 (ø7/8) Brazed ø22.2 (ø7/8) Brazed Low press pipe mm (in.) kg (lbs) Net weight 181 (400) 181 (400) 181 (400) 181 (400) Refrigerant / Lubricant External finish Operating temperature range Power source Power input kW Current A COP kW/kW High press pipe mm (in.) Refrigerant piping diameter Low press pipe mm (in.) Model Type Compressor Motor output kW Type Heat exchanger Water volume in plate m3/h Circulating Volume cfm water Pressure drop kPa Total capacity Indoor unit Model / Quantity Sound pressure level dB (measured in anechoic room) Capacity Set name Specifications HEAT SOURCE UNIT WR2 (Heat Recovery) Series PQRY-P YSHM-A Outdoor Unit Page130 Pham Van Tung - email: vantung@tle.com.vn - dt: 0985.11.61.62 hoac 0439783799 may le 710 Page131 O ptional parts SLP-2AA PLP-6BA PLP-6BAJ PAC-SH53TM-E PAC-SH59KF-E PAR-SA9FA-E PAC-SH48AS-E PAC-SA1ME-E PAC-SH65OF-E PAC-SH51SP-E Model Description Long life filter Description Model Description Drain pump kit Model PAC-SG95LE-E PAC-SH75DM-E PAC-SH94DM-E >>Wall mounted type (PKFY-VBM/VHM/VKM) Model PAC-KE07DM-E PAC-KE70HS-E Description Drain pump Control box replace kit External LEV Box Applicable capacity P20, P25, P32 P40,P50 P63, P71, P80 P100, P125 P140 Applicable capacity P15, 20, 25 P32, 40, 50 P63,100 P15, 20, 25, 32, 40, 50, 63 P15, 20, 25, 32, 40, 50, 63 Applicable capacity P40 P63,100,125 P40 P63 P100,125 P40,63,100,125 Applicable capacity Applicable capacity PAC-SH83DM-E PAC-SH84DM-E PAC-SH88KF-E PAC-SH89KF-E PAC-SH90KF-E PAR-SL94B-E P20, P25, P32, P40 Applicable capacity Optional parts *For PEFY-VMS1L only Necessary when long life filter is used Remarks P80 P140 P200, P250 P80 P140 P200/P250 P80, P140, P200, P250 P40~P250 P40, P50, P63 P71, P80 P100, P125, P140 P200, P250 P40, P50, P63 P71, P80 P100, P125, P140 P200, P250 Model PMP-40BM Model >>Ceiling concealed type (PEFY-VMS1(L)) Wireless remote controller kit High efficiency filter Drain pump kit VCM P20, P25, P32, P40 – – – – – – – – – PAC-KE88LAF PAC-KE89LAF PAC-KE85LAF PAC-KE80TB-F PAC-KE140TB-F PAC-KE250TB-F PAC-KE04DM-F >>Ceiling suspended type (PCFY-VKM) Drain pump Filter box Long life filter Description Model PAC-KE91TB-E PAC-KE92TB-E PAC-KE93TB-E PAC-KE94TB-E PAC-KE95TB-E >>Fresh air intake type (PEFY-VMH-E-F) Filter box Description >>Ceiling concealed type (PEFY-VMA(L)) PAC-KE04DM-F PAC-KE86LAF PAC-KE88LAF PAC-KE89LAF PAC-KE85LAF PAC-KE63TB-F PAC-KE80TB-F PAC-KE140TB-F PAC-KE250TB-F Applicable capacity P20, P25, P32, P40 P50, P63 P80, P100 P125 P20, P25, P32, P40, P50, P63, P80, P100 Model Description Decoration panel Applicable capacity Model Drain pump Filter box Applicable capacity >>1-way cassette type(PMFY-VBM) VBM – P32, P40, P50, P63, P80, P100, P125 P32, P40, P50, P63, P80, P100, P125 P32, P40, P50, P63, P80, P100, P125 P32, P40, P50, P63, P80, P100, P125 P32, P40, P50, P63, P80, P100, P125 P32, P40, P50, P63, P80, P100, P125 P32, P40, P50, P63, P80, P100, P125 P32, P40, P50, P63, P80, P100, P125 P32, P40, P50, P63, P80, P100, P125 CMP-40VLW-B CMP-63VLW-B CMP-100VLW-B CMP-125VLW-B PAC-KH11OF >>Ceiling concealed type (PEFY-VMH) OA duct flange Decoration panel Description >>2-way cassette type (PLFY-VLMD) Automatic Filter Elevation Panel Multi-functional casement High-efficiency filter element Wireless signal receiver Space panel “i-see” sensor Duct flange for fresh air intake Shutter plate Decoration panel Description >>4-way cassette type (PLFY-VBM/VCM) OPTIONAL PARTS FOR INDOOR UNITS Page132 Pham Van Tung - email: vantung@tle.com.vn - dt: 0985.11.61.62 hoac 0439783799 may le 710 Page133 CMY-Y104-G CMY-Y108-G CMY-Y1010-G CMY-Y302-G2 CMY-Y202-G2 Model CMY-Y100VBK2 CMY-Y200VBK2 CMY-Y300VBK2 CMY-Y102S-G2 CMY-Y102L-G2 Model CMY-Y62-G-E CMY-Y64-G-E CMY-Y68-G-E PAC-SG61DS-E PAC-SG64DP-E PAC-SG73RJ-E PAC-SG75RJ-E PAC-SH63AG-E Remarks For PUHY-P500~P650 / EP400~EP650YSHM For PUHY-P700~P900YSHM For PUHY-P950~P1250 / EP700~EP900YSHM 200 or below (Total capacity of indoor unit) 201-400 (Total capacity of indoor unit) 401-650 (Total capacity of indoor unit) The 1st branch of P450~P650 651 or above (Total capacity of indoor unit) The 1st branch of P700~P1250 For branches For branches For 10 branches CMY-Y104-G CMY-Y108-G CMY-Y1010-G CMY-Y100VBK2 CMY-Y202-G2 Model CMY-Y102S-G2 CMY-Y102L-G2 Remarks 200 or below (Total capacity of indoor unit) 201-400 (Total capacity of indoor unit) 401-650 (Total capacity of indoor unit) The 1st branch of P400,P500 For branches For branches For 10 branches For PUHY-HP400,HP500YSHM-A(BS) CMY-Y202-G2 Model CMY-R100VBK CMY-R200VBK CMY-Y102S-G2 CMY-Y102L-G2 CMY-Y302-G2 CMY-Y104-G CMY-Y108-G CMY-Y1010-G CMY-Y100VBK2 CMY-Y202-G2 Model CMY-Y102S-G2 CMY-Y102L-G2 Remarks 200 or below (Total capacity of indoor unit) 201-400 (Total capacity of indoor unit) 401-650 (Total capacity of indoor unit) The first branch of P400-P600 651 or above (Total capacity of indoor unit) For branches For branches For 10 branches For PQHY-P400-P600YSHM-A Description Remote Sensor for A/J/K/M-Net Control Remote ON/OFF adaptor for Indoor Unit Remote Display Adaptor for Indoor Unit Timer Adaptor for remote controller Output signal connector Input signal connector Transmission booster Air conditioner interface Electric amount count software BAC net R interface BAC net R and M-NET adapter Model PAC-YG10HA PAC-YG50ECA PAC-SC51KUA PAC-YG81TB PAC-YG83UTB PAC-YG85KTB PAC-YG71CBL Twinning kit Branch pipe (Joint) Description Optional parts BC Controller Model CMB-P104V-G, GB CMB-P105V-G CMB-P106V-G CMB-P108V-G, GA, GB CMB-P1010V-G, GA CMB-P1013V-G, GA CMB-P1016V-G, GA, HA, HB Branch pipe CMY-Y102S-G2 Junction pipe kit CMY-R160-J Description External input/output adapter for AG-150A Expansion controller for AG-150A Power supply unit for AG-150A / GB-50A Mounting attachment B type for AG-150A wall-mount installations Electric box for AG-150A wall-embed installations Mounting attachment A type for AG-150A/PAC-SC51KUA wall-mount installations Black surface cover for AG-150A CMY-Q100VBK CMY-Y202-G2 Model CMY-Y102S-G2 CMY-Y102L-G2 >>For PQRY series OPTIONAL EQUIPMENT FOR BC CONTROLLER Model PAC-SE41TS-E PAC-SE55RA-E PAC-SA88HA-EP PAC-SA89TA-EP PAC-SC37SA-E PAC-SC36NA-E PAC-SF46EPA LMAP02 PAC-YG11CDA PAC-YG31CDA BAC-HD150 OPTIONAL PARTS FOR CONTROL Twinning kit Branch pipe (Header) Branch pipe (Joint) Description >>For PQHY series Remarks 200 or below (Total capacity of indoor unit) 201-400 (Total capacity of indoor unit) 401-650 (Total capacity of indoor unit) The first branch of P400-P600 For PQRY-P400-P600YSHM-A Remarks For PURY-P450~P650 / EP400~EP600YSHM For PURY-P700~P800YSHM 200 or below (Total capacity of indoor unit) 201-400 (Total capacity of indoor unit) 401-650 (Total capacity of indoor unit) The 1st branch of P450~P650 Note : Indoor unit capacities: the capacity of an indoor unit is the same as the number used for its type identification Branch pipe (Joint) Twinning kit Description >>For PURY series Note : Indoor unit capacities: the capacity of an indoor unit is the same as the number used for its type identification Twinning kit Branch pipe (Header) Branch pipe (Joint) Description >>For PUHY-HP series Note : Indoor unit capacities: the capacity of an indoor unit is the same as the number used for its type identification Branch pipe (Header) Branch pipe (Joint) Twinning kit Description >>For PUHY series Description Branch Pipe (2 Branch) Header Header Drain Socket Centralized Drain Pan Port Connector (ø9.52 → ø12.7 ) Port Connector (ø15.88 → ø19.05) Air Protect Guide ( pcs required ) >>For PUMY-P100 , P125 , P140 VHM OPTIONAL PARTS FOR OUTDOOR UNITS year Checking cycle 25,000 hours years 15,000 hours 20,000 hours 20,000 hours Maintenance cycle Expansion valve Valve (solenoid valve, four-way valve) Sensor (thermistor, presser sensor) Drain pan Major components year Checking cycle years years 20,000 hours 20,000 hours Maintenance cycle year Long-life filter High-performance filter Fan belt Smoothing capacitor Fuse Crank case heater years year 5,000 hours 10 years 10 years years Replacement cycle Note1 This table shows major components Refer to the maintenance contract for details Note2 This replacement cycle shows a period in which products are expected to require no replacements Use this cycle for planning maintenance (budgeting expenses for replacing equipments etc.) Checking cycle Major components Table Replacement cycle Replacement cycle of consumable components [Note that replacement cycle does not mean guarantee period.] Sudden unpredictable accident may occur even if check-up is performed Optional parts Note1 This table shows major components Refer to the maintenance contract for details Note2 This maintenance cycle shows a period in which products are expected to require no maintenance Use this cycle for planning maintenance (budgeting the maintenance expense etc.) Checking/ Maintenance cycle may be shorter than the one on this table depending on the contents of maintenance check contract Electric board Heat exchanger Bearing Compressor Motor (Fan, Louver, drain pump) Major components Table Maintenance cycle Under the following conditions, equipment may not be able to be used at all, or the maintenance cycle and replacement cycle of equipment may need to be shortened When using equipment in high temperature and humidity or in rapid changes in temperature and humidity When using equipment in a big electric change of power voltage, frequency, and waveform distortion (They cannot be used outside of acceptable range.) When using equipment installed in a place where there is a lot of vibration When using equipment in the air with hazardous gas or oil mist as well as dust, salinity, and sulfur dioxide/ hydrogen sulfide When using equipment with frequent START/STOP or long operating hours The following tables are applicable when using equipment under the conditions below Normal use without frequent START/STOPs (The number of START/STOPs is assumed to be less than times per hour in normal use.) Operating hours are assumed to be 10 hours per day/2500 hours per year Maintenance cycle [Note that maintenance cycle does not mean guarantee period.] Maintenance equipment Page134 MEE08K108 FM33568 / ISO 9001;2000 Series Pham Van Tung - email: vantung@tle.com.vn - dt: 0985.11.61.62 hoac 0439783799 may le 710 http://Global.MitsubishiElectric.com New publication effective May 2009 Specifications subject to change without notice The ISO 14000 series is a set of standards applying to environmental protection set by the International Standard Organization (ISO) The Air Conditioning & Refrigeration Systems Works acquired environmental management system standard ISO 14001 certification ISO Authorization System The ISO 9000 series is a plant authorization system relating to quality management as stipulated by the ISO ISO 9001 certifies quality management based on the "design, development, production, installation and auxiliary services" for products built at an authorized plant The Air Conditioning & Refrigeration Systems Works acquired ISO 9001 certification under Series 9000 of the International Standard Organization (ISO) based on a review of Quality management for the production of refrigeration and air conditioning equipment MITSUBISHI ELECTRIC MULTIPLE SPLIT TYPE AIR CONDITIONERS CITY MULTI AIR CONDITIONING SYSTEMS CM09WD-F [...]... and striking image A superb new air-conditioner from Mitsubishi, providing a handsome fit for your own distinctive interior 40dB Human hearing limits Sound of rustling leaves (Extremely quiet) Optimum Air Distribution 60dB 80dB Library interior 27dB Sophisticated Design car interior (40km/h) Noise level Quiet passenger Subway car interior ✻2.5kw class Mitsubishi Electric air conditioners have always been... as BMS interface hardware and software etc Above all, with AG-150A/GB-50A, PC browser and long distance remote control (monitoring and operating) via communication Network is possible and easy MELANS MITSUBISHI ELECTRIC's Air-conditioner Network System (MELANS) leads air conditioner management a PC browser and Network era System Controller M-NET *6 *8 *7 *6 *10.For indoor use only , AG-150A GB-50A... temperature control Night setback Optimized start-up *9 *10 ( ) ( *6 ) ) 24x7 ( 24 AG-150A ) *6 24x7 ( 24 150/150 AG-150A+ PAC-YG50ECA *6 Remote Controller *6 *10 Integrated Communications Control with Mitsubishi' s Unique Transmission Network (M-NET) Page20 Pham Van Tung - email: vantung@tle.com.vn - dt: 0985.11.61.62 hoac 0439783799 may le 710 Page21 MA remote controller Non-polarized 2-wire MA remote... DESCRIPTION • Dimensions:130(W) x 120(H) x 19(D) mm :5-1/8(W) x 4-23/32(H) x 3/4(D) in EXTERNAL INPUT EXTERNAL OUTPUT ERROR INDICATION CURRENT TIME SCHEDULE FUNCTION ON/OFF UNITS FUNCTION Programmable Timer Mitsubishi Electric controllers are complimented by a weekly programmable timer, being able to control up to fifty indoor units The PAC-YT34STA also has hardwired connection available (On/Off input, fire... LM ADAPTER unit can connect up to 50 Groups/50 indoor units Using a single LONWORKS adapter (LM ADAPTER), you can connect up to a maximum of 50 indoor units * Up to 50 AG-150A units can be controlled MITSUBISHI ELECTRIC's CITYMULTI can be easily connected to the building management system through BACnet BACnet is the appropriate transmission method and used in many of the backbone networks and also... wired remote controller (or manually) First in the industry New model 72 patterns of airflow to accommodate*On the commercial air conditioners (According to the any room layout are available survey by Mitsubishi Electric) Conventional model Discharge air reaches wider area and the fan speed is decreased by 20% thanks to the new wide shape air outlet Cooling softly with Wide Air Flow Wide Air Flow (PLFY-P... direction levels (+Swing and Auto modes) and 4 wind power levels (+Auto mode) By setting the vane angle almost vertical, annoying direct wind can be avoided for your better comfort JDA GKEAJAIJ From Mitsubishi Electric, an Deluxe look in “Glossy Pure White” color innovative new floor-standing airconditioner Our Sleek louvers look just like pleasing mix of flat panels streamlined form and diversified... (Ethernet) BACnet BAC-HD150 Interface ndividual Remote Controller PEFY-VMH PCFY-VKM PKFY-VBM / VHM / VKM PFFY-VLEM PFFY-VKM PFFY-VLRM PFFY-VLRMM Fresh Air Intake type BACnet transmission line Ethernet MITSUBISHI ELECTRIC's CITYMULTI can be easily connected to the building management system through BACnet GB-50A PAC-SC30GRA Group Remote Controller Integrated centralized control software TG-2000A This... where the occupants would not even recognize the existence of air conditioner operation ONLY Quiet operation For living rooms, bed rooms, or offices where a sophisticated design is required The latest Mitsubishi innovation – floor-standing air-conditioner sophisticated in design, rich in function PFFY-P VKM-E INDOOR UNIT Floor standing exposed 600 mm dB(A) mm(in.) mm(in.) kW Pa m3/min mm in kg(lbs.)... 69% 70% 71% 72% 73% 74% 15RX Type 25RX Type 35RX Type *Cooling, High Fan speed, 50Hz 50RX Type 65RX Type Enthalpy exchange efficiency improve 80RX Type RX5 LOSSNAY 100RX 150RX 200RX Type Type Type RX4 Mitsubishi' s newly developed Hyper Eco Element is on board, offering the industry's best total heat exchange efficiency Energy conservation performance has been improved not only by reducing the air conditioning

Ngày đăng: 01/06/2016, 13:03

Tài liệu cùng người dùng

Tài liệu liên quan