RFCC LPG TREATER DUTY SPECIFICATION

13 334 0

Đang tải... (xem toàn văn)

Tài liệu hạn chế xem trước, để xem đầy đủ mời bạn chọn Tải xuống

THÔNG TIN TÀI LIỆU

Thông tin cơ bản

Định dạng
Số trang 13
Dung lượng 277,39 KB

Nội dung

[...]... limits of the block are specified as follows: Process Streams Untreated LPG Treated LPG Disulphide Oil Disulphide Oil Heavy Naphtha (Wash Oil) From To RFCC Unsat Gas Plant RFCC LPG Treater Unit RFCC LPG Treater Unit RFCC LPG Treater Unit RFCC LPG Treater Unit RFCC Unsat Gas Plant Storage Fresh Caustic Utility Plant Waste Water RFCC LPG Treater Unit 3550-8110-PD-024-0001 Pressure, kPa (g) Temperature , °C... 600 42 295 40 400(1) 42(1) RFCC LPG Treater Unit RFCC LPG Treater Unit Effluent Treatment Plant DSN: 609 A RFCC LPG TREATER DUTY SPECIFICATION FOSTER WHEELER ENERGY LTD PROCESS DOCUMENT Process Streams 3550-8110-PD-024-0001 PAGE 13 OF 13 REV D2 From To Pressure, kPa (g) Temperature , °C Foul Air RFCC LPG Treater Unit 50(1) 46(1) Spent Caustic RFCC LPG Treater Unit CDU / RFCC / SRU / Flare Effluent...A RFCC LPG TREATER DUTY SPECIFICATION 4.7.13 FOSTER WHEELER ENERGY LTD PROCESS DOCUMENT 3550-8110-PD-024-0001 PAGE 11 OF 13 REV D2 Catalyst Solvent Handling Licensor shall specify all permanent facilities required... facilities required for the purging and flushing of equipment and instruments Licensor shall identify purging and flushing mediums and estimated rates of consumption 3550-8110-PD-024-0001 DSN: 609 A RFCC LPG TREATER DUTY SPECIFICATION 4.8 FOSTER WHEELER ENERGY LTD PROCESS DOCUMENT 3550-8110-PD-024-0001 PAGE 12 OF 13 REV D2 Utilities Design data for available utility supplies are given in the Basic Engineering... considered for purge foul air from caustic treatment section 4.8.4 Other Requirements Licensor shall specify all other raw materials required for the RFCC LPG Treater Unit in addition to the feedstock, catalysts, chemicals and utilities discussed in this document This specification shall include materials, hazard data, method of use, frequency of use and consumption The design shall include all specialised... requirements and provide estimated rates of consumption for normal operation and for significant abnormal operations 4.8.1 Make-up Water LP Boiler Feed Water will be available as make up water in the RFCC LPG Treater Unit in accordance with recommendations established by the Licensor 4.8.2 Process Air Licensor shall include an Air Compressor Package for supply of air to caustic treatment section Plant... Caustic RFCC LPG Treater Unit CDU / RFCC / SRU / Flare Effluent Treatment Plant 400(1) 42(1) (1) To be advised / confirmed by Licensor 6 PROCESS GUARANTEES Complete definitive guarantee statements for the RFCC LPG Treatre Unit shall be specified by the Licensor in the Guarantee Agreement between Licensor and Employer to which reference shall be made in respect of contractual obligations Nevertheless, for... document, Licensor shall provide a list of guarantees which shall apply to design case The minimum scope shall include: • • • • • • • 3550-8110-PD-024-0001 Unit design capacity as per section 4.2 Product specifications as per section 4.5 Unit Turndown capability (40%) Consumption of Catalyst, Solvent and Caustic Cycle length Catalyst life Utility consumption based on the utility summary at completion of . Untreated LPG RFCC Unsat. Gas Plant RFCC LPG Treater Unit 1850 42 Treated LPG RFCC LPG Treater Unit RFCC Unsat. Gas Plant 1400 (1) 42 (1) Disulphide Oil RFCC LPG Treater Unit. RFCC LPG Treater Unit Storage (1) (1) Heavy Naphtha (Wash Oil) Storage RFCC LPG Treater Unit 600 42 Fresh Caustic Utility Plant RFCC LPG Treater Unit 295 40 Waste Water RFCC LPG. 4.7.1 Feedstock Specification Licensor shall specify the RFCC LPG Treater Unit design to process the feedstock as determined in Section 4.4 above. RFCC LPG TREATER DUTY SPECIFICATION A

Ngày đăng: 10/08/2015, 02:32

TỪ KHÓA LIÊN QUAN

w