Tài liệu hạn chế xem trước, để xem đầy đủ mời bạn chọn Tải xuống
1
/ 74 trang
THÔNG TIN TÀI LIỆU
Thông tin cơ bản
Định dạng
Số trang
74
Dung lượng
1,66 MB
Nội dung
Maintenance Serial POR Flow Control (XON / XOFF) FFl Maintenance Serial Port Flow Control (XON / XOFF) Software Version CPC-S and CPC-M, Version 1 0 and higher Address FFl 2# 9# 6# (0 or l)# Description Use this address to determine whether the DBS 824 system will control the flow of data between it and the device connected to the Maintenance serial port (CN2) ‘ XON/XOFF’ (if activated in this address) is a software switch that will temporarily stop the flow of data when the device s memory buffer receives more data than it can process and resume the flow when the buffer empties ‘XON/XOFF should be deactivated (default setting) if a flow control mechanism is present elsewhere in the interface (i e , in the printer or RTS and CTS lines) A flow control mechanism should always be present in order to prevent data from being lost during transmission FFl 2# 9# 6# (0 or l)# t kTurns off 66XON/OFF’ (824 software does not control data flow) 1 =Turns on “XON/XOFF” (824 software controls data flow) Notes DBS Buffer Size The size of the DBS 824 buffer for maintenance data is 1 000 bytes This is the maximum amount of data that the system can hold while the device is emptying its buffer l-76 DBS 824-l O-400 Issued 3/l 195 FFl Automatic Night 1 Mode Start Time System Timers Automatic Night 1 Mode Start Time Software Version CPC-S and CPC-M, Version 1 0 and higher Address FFl 3## 1# (OOOO-2359)# Description This option sets a time for the DBS 824 to automatically switch from ‘Day to ‘Night 1’ mode This program uses the 24-hour time format. Programming To set the automatic Night 1 mode start time FFl 3# l# (000012359)# t Night 1 Mode Start Time (in 24-hour format) FFl 3# l# CONF ON/OFF To disable the automatic Night 1 mode start time Related Programming Time Setting, FFl l# 2# HHMM# Automatic Day Mode Start Time FFl 3# 25# HHMM# Automatic Night 2 Mode Start Time FFl 3# 29# HHMM# Notes Infemdion witlr tite System Clock Automatic Night 1 start time depends on the accuracy of the DBS 824 clock issued 3/l /95 DBS 824-l O-400 l-77 Attendant Hold Recall Timer for CO Calls FFl Attendant Hold Recall Timer for CO Calls Software Version CPC-S and CPC-M, Version 1 0 and higher Address FFl 3# 2# (O-12)# Description This timer determines how long a trunk call can be held by the attendant(s) before it will recall Programming FFl 3# 2# (O-12)# t Recall Timer (Default=l, see table below) Table 1-7 Recall timer v&es for attendant-held CO calls Number 0 1 No recall 20 seconds Value 12- I 40 seconds I 1 60 seconds 1 80 seconds I 1 100 seconds 6 120 seconds 7 140 seconds 8 160 seconds 9 180 seconds 10 200 seconds I I 11 1 220 seconds I I I 12 1 240 seconds Related Programming Attendant Hold Recall Timer for Intercom calls FFl 3# 18# (0-12)# l-78 DBS 824-10-400 Issued 3/l/95 FFl Extension Hold Recall Timer for CO Calls Extension Hold Recall Timer for CO Calls Software Version CPC-S and CPC-M, Version 1 0 and higher Address FFl 3## 3# (0012)# Description This timer determines how long a hunk call will be held by an extension before it will recall Programming FFl 3# 3## (0912)# f Recall Timer (Default=7 see the following table) Table I 8 Recall tier values for extension-held CO calls 11 220 seconds 12 240 seconds Related Programming Extension Hold Recall Tier for Intercom Calls FFl 3# 19# (O-12)# Attendant Transfer Recall Timer for CO Calls FFl Attendant Transfer Recall Timer for CO Calls Software Version CPC-S and CPC-M, Version 1 0 and higher Address FFl 3# 4# (0-12)# Description When an attendant transfers a trunk call to an extension or hunt group, the transferred call will recall to the attendant if it is not answered This timer determines how long a transferred trunk call will go unanswered before it recalls Programming FFl 3# 4## (0112)# t Recall Timer (Default=1 see the following table) Table l-9 Recall timer values for attend&t transferred CO call2 11 220 seconds 12 240 seconds FF? txtension I rawer Hecall I imer for CO Calls Extension Transfer Recall Timer for CO Calls Software Version CPC-S and CPC-M, Version 1 0 and higher Address FFl 3# 5# (o-12)# Description When an extension aansfers a trunk call to another extension or to a hunt group, the transferred call will recall to the extension if it is not answered This timer determines how long a transferred trunk call will go unanswered before it recalls Programming FFl 3# 5# (0112)# + Recall Timer (Default=7 see the following table) Table I-10 Recall timer values for extension transferred CO calls I==+== 2 3 I== 4 5 7 a 9 10 Value No recall 20 seconds 40 seconds 60 seconds 80 seconds 100 seconds 120 seconds I 200 seconds 1 220 seconds 1 240 seconds Related Programming Extension Transfer Recall Timer for Intercom Calls FFl 3# 21# (0-12)# Notes Recall Treatment. If the extension does not answer the recall, the system will transfer the call to the attendant. issued 3/l /95 DBS 824-l O-400 1-81 Attendant Park Hold Recall Timer FFl Attendant Park Hold Recall Timer Software Version CPC-S and CPC-M, Version 1 0 and higher Address FF1 3# 6## (0-12)# Description An attendant phone can use up to 10 Call Park Numbers (00-09) to hold trunk calls These park numbers can be assigned to an FF key or accessed by placing a call on hold, then dialing 7501-7509 This program determines how long a parked call will be held before it recalls Programming FFl W 6## (0112)# f Recall Timer (Default=1 see the following table) Table l-11 Attendant park hold recall timer values l-82 DBS 824-l O-400 Issued 3/l /95 FFI Extension Park Hold Recall Timer Extension Park Hold Recall Timer Software Version CPCS and CPC-M, Version 1 0 and higher Address FF1 3# 7# (O-12)# Description Programming If an extension parks a call, the parked call will recall if it is not picked up This program determines how long the parked call will be held before it recalls FFl 3## 7# (O-12)# $ Recall Timer (Default=7 see the following table) Table l-I2 Extension park hold recall timer values Number Value 0 No recall 1 20 seconds 2 40 seconds 3 60 seconds I 80 seconds 5 100 seconds 6 120 seconds 7 140 seconds 8 160 seconds 9 180 seconds 10 200 seconds c 11 220 seconds 12 240 seconds Issued 3/l/95 DBS 824-10-400 1-83 Attendant Call Reversion Timer Software Version CPC-S and CPC-M, Version 1 0 and higher Address FFl 3# 8# (O-12)# Description By default the DBS 824 ultimately causes unanswered calls to revert to the attendant For example, if an extension places a call on hold and the held call recalls to the extension the recall reverts to the attendant if it is not answered Also, if a transfer recall is not answered by the transferring extension it also reverts to the attendant. This timer determines how long an unanswered call will ring at the last possible answering position before it reverts to the attendant For instance if an extension parks a call, the parked call will recall if it is not answered The Attendant Call Reversion limer will determine how long the park recall will ring at the extension before it reverts to the attendant If the Attendant Call Reversion Timer is set to default, the park recall will ring the extension for 180 seconds before reverting to the attendant. Programming FFl 3# 8# (0112)# f Reversion Timer (Defaul t=9 see the following table) Table I 13 Attendant call reversion timer values 1 Number I 0 No recall I 1 Value I 20 seconds I 2 3 4 I 5 I 6 120 seconds 40 seconds 60 seconds 80 seconds 100 seconds I 140 seconds 1 160 seconds l-04 DBS 824-10-400 Issued 3/l /95 FF? Attendant Ml Heversion Timer 9 180 seconds 10 200 seconds 11 1 220 seconds 12 1 240 seconds Notes Night Mode Restriction This feature is not available when the DBS 824 is in Night 1” or Night 2’ mode Issued 3/l 195 DBS 824-l O-400 [...]... following table) Table l-26 Timer values for CO delayed ringing 3 4 5 6 7 8 9 10 11 1 2 13 14 15 l-1 04 After 16 seconds After 20 seconds After 24 seconds After 28 seconds After 32 seconds After 34 seconds After 36 seconds After 44 seconds After 48 seconds After 52 seconds After 56 seconds After 60 seconds After 64 seconds DBS 8 24- l O -40 0 Issued 3/l /95 CO Delayed Ring Timer FFl Related Programming Delayed... extension delayed ringing Number 0 Value After 4 seconds 1 After 8 seconds 2 After 12 seconds [ After 16 seconds I After 20 seconds After 24 seconds 1 6 1 After 28 seconds I 1 After 32 seconds 1 After 34 seconds 9 10 After 44 seconds 11 After 48 seconds 12 After 52 seconds 13 After 56 seconds 14 After 60 seconds 15 l-106 After 36 seconds After 64 seconds DBS 8 24- l O -40 0 Issued 3/l /95 Extension Delayed Ring... ringing Programming FFl 3## 24# (0-15)# f Timer Setting (Default=2, see the following table) Table l-28 Hunt group no answer timer values Number 0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 l-108 Value After 4 seconds After 8 seconds After 12 seconds After 16 seconds After 20 seconds After 24 seconds After 28 seconds After 32 seconds After 34 seconds After 36 seconds After 44 seconds After 48 seconds After 52 seconds... 8 1 4 0 seconds 1 2 3 4 5 9 10 1 1 12 13 14 I 4 5 seconds 15 1-08 I 7 5 seconds 5 seconds 5 5 secotids 6 sxonds 6 5 seconds 7 seconds DBS 8 24- l O -40 0 Issued 3/l/95 Automatic Pause Timer FFl Related Programming Automatic Pause for PBX Line PBX Access Codes FF2 (Trunk)# 13# (0 or l># FFl 2# 3# (l-8)# (O-999 or 0* 9*)## Automatic Pause Position for PBX Access Codes (1 3)# Issued 3/l /95 DBS 8 24- l O -40 0... the DBS 8 24 emulates the initial CO ring Programming FFl 3## 14# (0115)# f Timer Setting (Defaul t=7 see the following table) Table l-18 Inbound ring cycle expansion timer values Number 0 Value Synchronizes to the incoming call signal l50ms I 1OOms I 1 150ms I2OOms I 250 ms I 1300 ms 1 I t 2 3 4 5 6 7 8 I Issued 3/l/95 I 35oms 40 0ms 9 t 1 1 45 0 ms 11 12 I5OOms I I 550 ms I 16OOms DBS 8 24- 10 -40 0 1 1-95... seconds off Length of CO Ri Cycle Detection Timer- seconds Y Issued 3/l /95 4 DBS 8 24- l O -40 0 Incoming Ring Cycle Detection Timer l-93 CO Ring Cycle Detection Timer FFl Programming FFl 3# 13## (O-3)# f 0 =4 seconds 1=6 seconds 2=8 seconds 3= 10 seconds Related Programming Inbound Ring Cycle Expansion Timer FFl 3# l# l- 94 DBS 8 24- 10 -40 0 Issued 3/l/95 Inbound Ring Cycle Expansion Timer FFl Inbound Ring Cycle... values Value Number 0 1 second 1 5 seconds 2 10 seconds 3 15 seconds 4 20 seconds 5 25 seconds 6 30 seconds 7 35 seconds 8 40 9 I 10 1 seconds 45 seconds 1 50 seconds I 1 55 seconds 12 1 60 seconds 13 1 65 seconds 14 70 seconds 15 75 seconds Related Programming Auto-Repeat Dialing Count FFl 2# l# 34# (0-15)# Issued 3/l i95 DBS 8 24- l O -40 0 l-111 ... Ring Assignments FF4 5# (ExtPort)## (Trunk)# CO Delayed Day Ring Assignments for Hunt Groups FF4 5# (HuntGrp)# (Trunk)# CO Delayed Night 1 Ring Assignments FF4 6# (Ext.Port)# (Trunk)# CO Delayed Night 1 Ring Assignments for Hunt Groups FF4 6# (Hunffirp)# (Trunk)# CO Delayed Night 2 Ring Assignments FF4 9# 2# (ExtPort)# (Trunk)# CO Delayed Night 2 Ring Assignments for Hunt Groups FF4 9# 2# (HuntGrp)#... values for attendant-held intercom calls Value Number 1 No recall I 20 seconds 2 40 seconds 3 60 seconds 4 80 seconds 5 100 seconds 6 120 seconds I 140 seconds 1 160 seconds 1 180 seconds 10 200 seconds 11 220 seconds 12 240 seconds Related Programming Attendant Hold Recall Timer for CO Calls FFl 3# 2# (0- 12)# l-100 DBS 8 24- 10 -40 0 Issued 3/l/95 Extension Hold Recall Timer for Intercom Calls FFl Extension... extension-held intercom calls Value Number 0 1 2 20 seconds 3 60 seconds 4 80 seconds 5 100 seconds 6 7 120 seconds 140 seconds 8 1 No recall 160 seconds 9 10 40 seconds 1 180 seconds 200 seconds 11 I- 220 seconds 12 240 seconds Related Programming Extension Hold Recall Timer for CO Calls FFl 3# 3# (0-12)# Issued 3/l /95 0% 8 24- l O -40 0 l-101 Attendant Transfer Recall Timer for Intercom Calls FFl Attendant . recall I 1 Value I 20 seconds I 2 3 4 I 5 I 6 120 seconds 40 seconds 60 seconds 80 seconds 100 seconds I 140 seconds 1 160 seconds l- 04 DBS 8 24- 10 -40 0 Issued 3/l /95 FF? Attendant. minutes 1 3 15 minutes 4 20 minutes 5 25 minutes 6 1 30 minutes 1 I 35 minutes 8 40 minutes 9 45 minutes I 50 minutes 12 1 60 minutes 13 65 rqinutes 14 70 minutes I 15 1 75 minutes I l-86 DBS 8 24- l O -40 0 Issued. seconds 4 2 seconds 5 2 5 seconds 6 3 seconds 7 3 5 seconds 8 4 0 seconds 9 4 5 seconds 10 5 seconds 11 12 5 5 secotids 6 sxonds 13 6 5 seconds 14 7 seconds 15 7 5 seconds 1-08 DBS 8 24- l O -40 0 Issued