1. Trang chủ
  2. » Kỹ Thuật - Công Nghệ

Sổ tay ma sát và Nano P10 pot

93 199 0

Đang tải... (xem toàn văn)

Tài liệu hạn chế xem trước, để xem đầy đủ mời bạn chọn Tải xuống

THÔNG TIN TÀI LIỆU

Thông tin cơ bản

Định dạng
Số trang 93
Dung lượng 3,76 MB

Nội dung

Bhushan, B. “Nanomechanical Properties of Solid Surfaces and Thin Films” Handbook of Micro/Nanotribology. Ed. Bharat Bhushan Boca Raton: CRC Press LLC, 1999 © 1999 by CRC Press LLC © 1999 by CRC Press LLC 10 Nanomechanical Properties of Solid Surfaces and Thin Films Bharat Bhushan 10.1 Introduction 10.2 Nanoindentation Hardness Measurement Apparatuses Commercial Nanoindentation Hardness Apparatuses with Imaging of Indents after Unloading • Prototype Depth- Sensing Nanoindentation Hardness Apparatuses • Commercial Depth-Sensing Nanoindentation Hardness Apparatus and Its Modifications 10.3 Analysis of Indentation Data Hardness • Modulus of Elasticity • Determination of Load Frame Compliance and Indenter Area Function • Hardness/Modulus 2 Parameter • Continuous Stiffness Measurement • Modulus of Elasticity by Cantilever Deflection Measurement • Determination of Hardness and Modulus of Elasticity of Thin Films from the Composity Response of Film and Substrate 10.4 Examples of Measured Mechanical Properties of Engineering Materials Load–Displacement Curves • Continuous Stiffness Measurements • Hardness and Elastic Modulus Measurements 10.5 Microscratch Resistance Measurement of Bulk Materials Using Micro/Nanoscratch Technique 10.6 Nanoindentation and Microscratch Techniques for Adhesion Measurements, Residual Stresses, and Materials Characterization of Thin Films Adhesion Strength and Durability Measurements Using Nanoindentation • Adhesion Strength and Durability Measurements Using Microscratch Technique • Residual Stress Measurements Using Nanoindentation • Microwear Measurements Using Modified Nanoindentation 10.7 Other Applications of Nanoindentation Techniques Time-Dependent Viscoelastic/Plastic Properties • Nanofracture Toughness • Nanofatigue 10.8 Closure References © 1999 by CRC Press LLC 10.1 Introduction Mechanical properties of the solid surfaces and surface thin films are of interest as the mechanical properties affect the tribological performance of surfaces. Among the mechanical properties of interest, one or more of which can be obtained using commercial and specialized hardness testers, are elastic–plas- tic deformation behavior, hardness, Young’s modulus of elasticity, scratch resistance, film-substrate adhe- sion, residual stresses, time-dependent creep and relaxation properties, fracture toughness, and fatigue. Hardness measurements can assess structural heterogeneities on and underneath the surface such as diffusion gradients, precipitate, presence of buried layers, grain boundaries, and modification of surface composition. Hardness implies the resistance to local deformation. For example, with materials that go through plastic deformation, a hard indenter is pressed into the surface and the size of the permanent (or plastic) indentation formed for a given load is a measure of hardness. With rubberlike materials (which do not go through plastic deformation), an indenter is pressed into the material and how far it sinks under load is measured. With brittle materials (which do not go through plastic deformation), hardness is measured by scratching it by a harder material. Hardness signifies different things to different people, for instance, resistance to penetration to a metallurgist, resistance to scratching to a mineralogist, and resistance to cutting to a machinist, but all are related to the plastic flow stress of material. Hardness measurements usually fall into three main categories: scratch hardness, rebound or dynamic hardness, and static indentation hardness (Tabor, 1951). Scratch hardness is the oldest form of hardness measurement. It depends on the ability of one material to scratch another or to be scratched by another solid. The method was first put on a semiquantitative basis by Friedrich Mohs in 1822, who selected ten minerals as standards, beginning with talc and ending with diamond. The Mohs scale is widely used by mineralogists and lapidaries (Tabor, 1951). Today, solid and thin-film surfaces are scratched by a sharp stylus made of hard material typically diamond, and either the loads required to scratch or fracture the surface or delaminate the film or the normal/tangential load–scratch size relationships are used as a measure of scratch hardness and/or interfacial adhesion (Heavens, 1950; Tabor, 1951, 1970; Benjamin and Weaver, 1960; Campbell, 1970; Ahn et al., 1978; Mittal, 1978; Perry, 1981, 1983; Jacobson et al., 1983; Valli, 1986; Bhushan, 1987; Steinmann et al., 1987; Wu, 1991; Bhushan et al., 1995, 1996, 1997; Bhushan and Gupta, 1995; Gupta and Bhushan, 1995a,b; Patton and Bhushan, 1996; Bhushan and Li, 1997; Li and Bhushan, 1998b,c). Another type of hardness measurement is rebound or dynamic hardness involving the dynamic deformation or indentation of the surface. In this method, a diamond-tipped hammer (known as tup) is dropped from a fixed height onto the test surface and the hardness is expressed in terms of the energy of impact and the size of the remaining indentation. For example, in the shore rebound scleroscope, the hardness is expressed in terms of the height of rebound of the indenter. The methods most widely used in determining the hardness of materials are (quasi) static indentation methods . Indentation hardness is essentially a measure of their plastic deformation properties and only to a secondary extent with their elastic properties. There is a large hydrostatic component of stress around the indentation, and since this plays no part in plastic flow the indentation pressure is appreciably higher than the uniaxial flow stress of the materials. For many materials, it is about three times as large, but if the material shows appreciable elasticity, the yielding of the elastic hinderland imposes less constraint on plastic flow and the factor of proportionality may be considered less than 3. Indentation hardness depends on the time of loading and on the temperature and other operating environmental conditions. In the indentation methods, a spherical, conical, or pyramidal indenter is forced into the surface of the material which forms a permanent (plastic) indentation in the surface of the material to be examined. The hardness number (GPa or kg/mm 2 ), equivalent to the average pressure under the indenter, is calculated as the applied normal load divided by either the curved (surface) area (Brinell, Rockwell, and Vickers hardness numbers) or the projected area (Knoop and Berkovich hardness numbers) of the contact between the indenter and the material being tested, under load (Lysaght, 1949; Berkovich, 1951; Tabor, © 1999 by CRC Press LLC 1951, 1970; Mott, 1957; O’Neill, 1967; Westbrook and Conrad, 1973; Anonymous, 1979; Johnson, 1985; Blau and Lawn, 1986; Bhushan and Gupta, 1997). Macrohardness tests are widely used because of availability of inexpensive testers, simplicity of mea- surement, portability, and direct correlation of the hardness with service performance. For applications with ultrasmall loads (few mN to nN) being applied at the interface, nanomechanical properties of the skin (as thin as a monolayer) of a solid surface or a surface film are of interest. Furthermore, ultrathin films as thin as a monolayer are used for micromechanical applications and their mechanical properties are of interest. Hardness tests can be performed on a small amount (few mg) of material and with the state-of-the-art equipment it is possible to measure hardness of the few surface layers on the sample surface. In a conventional indentation hardness test, the contact area is determined by measuring the inden- tation size by a microscope after the sample is unloaded. At least, for metals, there is a little change in the size of the indentation on unloading so that the conventional hardness test is essentially a test of hardness under load, although it is subject to some error due to varying elastic contraction of the indentation (Stilwell and Tabor, 1961). More recently, in depth-sensing indentation hardness tests, the contact area is determined by measuring the indentation depth during the loading/unloading cycle (Pethica et al., 1983; Blau and Lawn, 1986; Wu et al., 1988; Bravman et al., 1989; Doerner et al., 1990; Nix et al., 1992; Pharr and Oliver, 1992; Oliver and Pharr, 1992; Nastasi et al., 1993; Townsend et al., 1993; Bhushan et al., 1995, 1996, 1997; Bhushan and Gupta, 1995; Gupta and Bhushan,1995a, b; Bhushan, 1996; Patton and Bhushan, 1996; Bhushan and Li, 1997; Li and Bhushan, 1998b,c). Depth measurements have, however, a major weakness arising from “piling-up” and “sinking-in” of material around the indentation. The measured indentation depth needs to be corrected for the depression (or the hump) of the sample around the indentation, before it can be used for calculation of the hardness (Doerner and Nix, 1986; Doerner et al., 1986; Wu et al., 1988; Nix, 1989; Oliver and Pharr, 1992; Fabes et al., 1992; Pharr and Oliver, 1992). Young’s modulus of elasticity is the slope of the stress–strain curve in the elastic regime. It can obtained from the slope of the unloading curve (Nix, 1989; Oliver and Pharr, 1992; Pharr and Oliver, 1992). Hardness data can be obtained from depth-sensing instruments without imaging the indentations with high reproducibility. This is particularly useful for small indents required for hardness measurements of extremely thin films. In addition to measurements of hardness and Young’s modulus of elasticity, static indentation tests have been used for measurements of a wide variety of material properties such as elastic–plastic defor- mation behavior (Pethica et al., 1983; Doerner and Nix, 1986; Stone et al., 1988; Fabes et al., 1992; Oliver and Pharr, 1992), flow stress (Tabor, 1951), scratch resistance and film–substrate adhesion (Heavens, 1950; Tabor, 1951; Benjamin and Weaver, 1960; Campbell, 1970; Ahn et al., 1978; Mittal, 1978; Perry, 1981, 1983; Jacobson et al., 1983; Valli, 1986; Bhushan, 1987; Steinmann et al., 1987; Stone et al., 1988; Wu et al., 1989, 1990b; Wu, 1990, 1991; Bhushan et al., 1995, 1996, 1997; Bhushan and Gupta, 1995; Gupta and Bhushan, 1995a, b; Patton and Bhushan, 1996; Bhushan and Li, 1997; Li and Bhushan, 1998b, c), residual stresses (Swain et al., 1977; Marshall and Lawn, 1979; LaFontaine et al., 1991), creep (West- brook, 1957; Mulhearn and Tabor, 1960/61; Atkins et al., 1966; Walker, 1973; Chu and Li, 1977; Hooper and Brookes, 1984; Li et al., 1991), stress relaxation (Hart and Solomon, 1973; Chu and Li, 1980; Hannula et al., 1985; Mayo et al., 1988a, 1990; LaFontaine et al., 1990a,b; Raman and Berriche, 1990, 1992; Wu, 1991; Nastasi et al., 1993), fracture toughness and brittleness (Palmquist, 1957; Lawn et al., 1980; Chan- tikul et al., 1981; Mecholsky et al., 1992; Lawn, 1993; Pharr et al., 1993; Bhushan et al., 1996; Li et al., 1997, 1998a), and fatigue (Li and Chu, 1979; Wu et al., 1991). The extended load range of static indentation hardness testing is shown schematically in Figure 10.1. We note that only the lower micro- and ultramicrohardness or nanohardness load range can be employed successfully for measurements of extremely thin (submicron-thick) films. The intrinsic hardness of surface layers or thin films becomes meaningful only if the influence of the substrate material can be eliminated. It is therefore generally accepted that the depth of indentation should never exceed 30% of the film thickness (Anonymous, 1979). The minimum load for most commercial microindentation testers © 1999 by CRC Press LLC available is about 10 mN. Loads on the order of 50 µN to 1 mN are desirable if the indentation depths are to remain few tens of a nanometer. In this case, the indentation size sometimes reaches the resolution limit of a light microscope, and it is almost impossible to find such a small imprint if the measurement is made with a microscope after the indentation load has been removed. Hence, either the indentation apparatuses are placed in situ and a scanning electron microscope (SEM) or in situ indentation depth measurements are made. The latter measurements, in addition, would offer the advantages to observe the penetration process itself. In viscoelastic/visoplastic materials, since indentation size changes with time, in situ measurements of the indentation size are particularly useful, which can, in addition, provide more complete creep and relaxation data of the materials. In this chapter, we will review various prototype and commercial nanoindentation hardness test apparatuses and associated scratch capabilities for measurements of mechanical properties of surface layers of bulk materials and extremely thin films (submicron in thickness). A commercial depth-sensing nanohardness test apparatus will be described in detail followed by data analysis and use of nanohardness apparatuses for determination of various mechanical properties of interest. 10.2 Nanoindentation Hardness Measurement Apparatuses In this section, we review nanoindentation hardness apparatuses in which the indent is imaged after the load has been removed as well as the depth-sensing indentation apparatuses in which the load-indentation depth is continuously monitored during the loading and unloading processes. Earlier work by Alekhin et al. (1972), Ternovskii et al. (1973), and Bulychev et al. (1975, 1979) led to the development of depth- sensing apparatuses. Both prototype and commercial apparatuses are reviewed. A commercial depth- sensing nanoindentation hardness test apparatus manufactured by Nano Instruments, Inc., is extensively used and is described in detail. 10.2.1 Commercial Nanoindentation Hardness Apparatuses with Imaging of Indents after Unloading For completeness, we first describe a commercially available microindentation hardness apparatus (Model No. Micro-Duromet 4000) that uses a built-in light optical microscope for imaging of indents after the sample is unloaded. It is manufactured by C. Reichert Optische Werke AG, A-1171, Vienna, Box 95, Austria, Figure 10.2 (Pulker and Salzmann, 1986). The case of the indenter is of the size of a microscope objective mounted on the objective revolver. The load range for this design is from 0.5 mN to 2 N; therefore, it is used for thicker films. A commercial nanoindentation hardness apparatus for use inside an SEM (Model No. UHMT-3) for imaging the indents after the sample is unloaded, is manufactured by Anton Paar K.G., A-8054, Graz, Austria. The apparatus is mounted on the goniometer stage of the SEM. In this setup, the indenter is FIGURE 10.1 Extended load range of static indentation hardness testing. © 1999 by CRC Press LLC mounted on a double-leaf spring cantilever and is moved against the sample by an electromagnetic system to attain the required indentation load, which is measured by strain gauges mounted on the leaf springs, Figure 10.3 (Bangert et al., 1981; Bangert and Wagendristel, 1986). Tilting the stage with respect to the electron beam allows observation of the tip during the indentation process. The indentation cycle is fully programmable and is controlled by the strain gauge signal. The motion of the indenter, perpendicular to the surface, is performed by increasing the coil current until a signal from the strain gauges is detected. Further, an increase of the current up to a certain gauge signal leads to the desired indentation force ranging from 50 µN to 20 mN. After the required load has been reached and the dwell time has elapsed, the sample is unloaded, and the indentation diagonal is measured by an SEM. FIGURE 10.2 Schematic of the microindentation hardness apparatus for use in a light optical microscope. (From Pulker, H.K. and Salzmann, K., 1986, SPIE Thin Film Technol. 652, 139–144. With permission.) FIGURE 10.3 Schematic of the nanoindentation hardness apparatus for use in an SEM by Anton Parr K.G., Graz, Austria. (From Bangert, H. et al., 1981, Colloid Polym. Sci. 259, 238–242. With permission.) © 1999 by CRC Press LLC 10.2.2 Prototype Depth-Sensing Nanoindentation Hardness Apparatuses Of all the nanohardness apparatuses described in this section, the apparatus designs by IBM Almaden Research Center and Nano Instruments, Inc., are the most modern apparatuses with the largest range of test capabilities. However, the IBM Almaden apparatus is not commercially available. The apparatus built by MTS Nano Instruments Innovation Center which is called the Nanoindenter, is commercially available and is comparable to the IBM Almaden design with complete software. Nanoindenter is most commonly used by the industrial and academic research laboratories. It will be described in some detail. The NEC design is commercially available; however, this has limited capabilities and is not popular. 10.2.2.1 IBM T.J. Watson Research Center Microhardness Tester Design The apparatus to be described here is a “microhardness apparatus” and is only included here for com- pleteness. Pharr and Cook (1990) instrumented a conventional microhardness tester to measure inden- tation load and penetration depth during the entire indentation process, Figure 10.4. This modified machine has the advantage of being relatively inexpensive since many of its components are standard equipment. Pharr and Cook used a Buehler Micromet II machine with a load range of 0.1 to 10 N although other commercially available units can be used. In their modifications, load was measured with a piezoelectric load cell (Kistler model 9207) with a resolution of 0.5 mN and a maximum load of 50 N. The load cell was conditioned by a Kistler model 5004 charge amplifier with a frequency response of about 180 kHz. Displacement was measured with two capacitec model HPC-75 capacitance gauges with matching ampli- fier and conditioner (model 3201). These gauges have high resolution of about 0.05 µm and frequency response of 10 kHz. The sample stage was replaced with an assembly in which the load cell could be rigidly supported. A mount for the displacement gauges was then connected directly to the top of the FIGURE 10.4 Schematic of a modified commercial microhardness test apparatus for load-penetration depth mea- surements. (From Pharr, G.M. and Cook, R.F., 1990, J. Mater. Res. 5, 847–851. With permission.) © 1999 by CRC Press LLC load cell. The specimen was attached to the center of this mount with the displacement gauges flanking it on either side. The gauges sensed the motion of a thin aluminum wing rigidly attached to the base of the moving diamond and its mount. The outputs from the displacement gauges were averaged so as to negate any displacements caused by bending in the system. The load and displacement outputs were measured using a storage oscilloscope. In a typical experiment, the load and displacement signals were recorded as a function of time, with the load–displacement curve derived subsequently from these data. This modified apparatus can only be used for loads as low as about 100 mN, making it useful for only microhardness measurements. 10.2.2.2 AERE Harwell/Micro Materials Design Newey et al. (1982) developed an apparatus capable of continuously monitoring the penetration depth as the load is applied, Figure 10.5. The test sample I is mounted on a piezoelectric barrel transducer J, their horizontal position being controlled by a micrometer movement K. A high-voltage supply is connected to the transducer J by means of a commutator arrangement. The indenter assembly C is made from folded tantalum foil to give a light structure, and is fitted with tungsten pivots seated in jeweled bearings D, from which it is suspended. Force is applied electrostatically by increasing the potential on the two plates B; force plate A is part of indenter assembly C and is kept at ground potential. The resulting force causes A to move into B and indenter F to move toward the specimen. The indentation depth is measured with a capacitor bridge arrangement. Plates G and H for measurement of indenter motion, are concentric with the axis of the indenter holder and form part of a capacitor bridge arrangement (plate G is insulated from C by mica sheet M). E is a piezoelectric bimorph transducer used to restrain the indenter assembly C when the specimen is being moved toward the indenter. In the modified design reported by Pollock et al. (1986), the specimen can be transferred between two locations (test and microscopic observation). A particular area of interest may therefore be identified in the microscope and then transferred to the test position. This instrument is commercially available as Nano Test 550 from Micro Materials, Unit 3, The Byre, Wrexham Technology Park, Wrexham, Clywd, U.K. In this apparatus, an indentation load up to 500 mN with a resolution of 10 µN can be applied and the depth resolution measurement is better than 0.1 nm. FIGURE 10.5 Schematic of a depth-sensing nanoindentation hardness apparatus by Newey et al. (From Newey, D. et al., 1982, J. Phys. E: Sci. Instrum. 15, 119–122. With permission.) © 1999 by CRC Press LLC 10.2.2.3 Philips Research Laboratory Design Wierenga and Franken (1984) built a nanoindentation apparatus that measures in situ the indenter penetration as a function of time (relaxation testing) or load with a resolution of 5 nm, Figure 10.6. The indentation force can be varied from 10 µN to 5 mN. Indenter (1) is clamped to the holder (2) and can easily be exchanged. The indenter holder (2) supported on an air bearing can be moved virtually frictionlessly along a horizontal shaft (3). Two stops (4 and 5) attached to the shaft limit the movement of the holder. The shaft is supported by a linear drive mechanism (6) making use of friction wheels and guide rollers. The apparatus is equipped with two inductive displacement transducers (7 and 8) which measure the displacement of the indenter with respect to the shaft and of the shaft with respect to the surroundings, respectively. The signal from transducer 8 is automatically corrected for changes in the ambient temperature during an experiment. This is done by the application of a temperature-sensing element mounted on transducer 8. The indenter force is adjusted by means of an electromagnetic system. A coil (9) is attached to the indenter holder and can move in the annular gap of an electromagnet (10), which is mounted on the shaft. The sample holder (11) can be moved in two directions perpendicular to the axis of the shaft (3). Samples are held by using an accessory (12) which is held by suction to the sample holder. (Also see Wierenga and van der Linden, 1986.) For an indentation experiment, the indenter is first brought into contact with the sample. For this purpose, transducer 7 is adjusted to give a zero signal when the stylus holder is somewhere between stops 4 and 5. By switching on the motor of the linear drive mechanism, the shaft and indenter are moved toward the sample. After the indenter has touched the sample surface, movement of the shaft is auto- matically halted when the signal from transducer 7 equals zero. The starting position for an indentation experiment is achieved by moving the sample a short distance sideways at a minimum indenter force. If the indenter force is increased, the signal from transducer 7 is kept to zero with the control system by moving the shaft. Thus, the penetration depth can be determined with transducer 8, which measures the displacement of the shaft with respect to the frame. FIGURE 10.6 Schematic of a depth-sensing nanoindentation hardness apparatus by Philips Laboratory, Eindhoven, The Netherlands: (1) indenter, (2) indenter holder, (3) central shaft, (4) and (5) stops, (6) linear drive mechanism, (7) and (8) displacement transducers, (9) coil, (10) electromagnet, (11) sample holder, (12) accessory for holding the sample (From Wierenga, P.E. and van der Linden, J. H. M., 1986, in Tribology and Mechanics of Magnetic Storage Systems, Vol. 3 (B. Bhushan and N.S. Eiss, eds.), pp. 31–37, SP-21, ASLE, Park Ridge, IL. With permission.) © 1999 by CRC Press LLC 10.2.2.4 IBM Corporation/University of Arizona Tucson Design Bhushan et al. (1985, 1988) and Williams et al. (1988) built a nanoindentation apparatus that can independently control and measure indentation depths with a resolution of 0.2 nm and loads with a resolution of 30 µN in situ , Figure 10.7. Samples and indenter positions are measured with a specially designed polarization interferometer. A minimum load of about 0.5 mN can be applied. In the apparatus, the test sample is clamped to the top of a mirror that is kinematically mounted to the moving stage of a damped parallel spring guide. The spring guide ensures smooth, low-friction, vertical motion. A linear actuator nested inside the parallel spring guide drives the moving stage vertically. The indenter is sus- pended above the sample and screws into the bottom of the moving stage of another damped parallel spring guide. Another mirror is kinematically mounted to the top of this stage. The indenter spring guide is independently calibrated and checked for linearity so that the indenter load can be correctly inferred. Both spring guides are damped to prevent oscillations and utilize auxiliary counterbalance springs to keep the spring guides close to their neutral, unstressed position, where their motion is linear. The vertical positions of the sample and indenter mirrors and thus the positions of the sample and indenter are monitored independently by the polarization interferometer. Light from a helium–neon laser enters the polarization interferometer where the light beam is separated by a diffraction grating into seven separate beams, six equally spaced beams on a 12-mm-diameter circle and one in the center of the circle, which serves as the reference (Williams et al., 1988). Leaving the interferometer, the beams pass through a beam expander to enlarge the beam circle diameter. Three of the outer beams strike the indenter mirror and the other three pass through holes in the indenter mirror and stage and strike the sample mirror. Because of the large beam circle diameter, the beams avoid striking the central obstruc- tions, the sample, and the indenter. The light reflected from both mirrors then returns to the interfer- ometer. Thus, the positions of the sample and indenter mirrors are continuously monitored by comparing the relative phases of the light beams returning from the mirrors to the central reference beam. The computer subtracts the positions of the two mirrors to determine the resulting indentation depth and multiplies the indenter mirror position and the spring constant of the indenter parallel spring guide to determine the indentation load. To initiate a test, the actuator slowly raises the sample toward the indenter until motion is registered by the interferometer, implying that contact has been made between the sample and the indenter. The control loop then takes over and performs the chosen test — it either keeps the load constant and measures the penetration depth as a function of time or it keeps the depth constant and measures the load as a function of time. 10.2.2.5 NEC, Kawasaki Design Tsukamoto et al. (1987) and Yanagisawa and Motomura (1987, 1989) developed a nanoindentation hardness apparatus. NEC Corp., Kawasaki 216, Japan is attempting to commercialize it, although it is not popular, Figure 10.8. It consists of three parts: an indenter actuator, a load detector, and a displace- ment sensor. Indenter (1) with a diamond tip is attached to stylus (2) which is clamped on holder (3). The holder is attached to a piezoelectric actuator (4), which drives the holder up and down controlled by a personal computer (5) through an amplifier (6), a regulated power source (7), and an interface (8). Indentation load is detected by a digital electrobalance (9) with a 1-µN resolution at loads of up to 300 mN. The output signal is fed to the X -axis of an X – Y recorder (10). A sample (11) is placed on a sample disk (12). Penetration depth is detected by a fiber-optic displacement instrument (13) with a 4-nm displacement resolution. Light from a tungsten lamp in the displacement instrument is irradiated onto a mirror (15) through an optical fiber (14). The intensity of the reflected light from the mirror on the sample disk is measured by a photodetector in the displacement instrument and reduced to a displacement between the indenter and the sample. An output signal from the displacement instrument is connected to the Y -axis of the X – Y recorder. The apparatus is surrounded by a metal box (20) to minimize the influence of air currents and heat radiation. It is placed on a vibration-isolation air table (16). For an indentation experiment, the indenter is first brought into contact with the sample by a micro- meter (17). When contact is detected with the sample by the electrobalance, the distance between the [...]... at the maximum load (required for hardness calculation) from hmax , © 1999 by CRC Press LLC FIGURE 10.20 Schematic representation of the indenting process illustrating the depression of the sample around the indentation and the decrease in indentation depth upon unloading (From Oliver, W.C and Pharr, G.M., 1992, J Mater Res 7, 1564–1583 With permission.) FIGURE 10.21 hc = hmax − ε Wmax Smax Schematic... specimen is selected using the microscope (maximum magnification of 1500¥) The remote-operation option provides a TV camera that is mounted atop the microscope, which permits the image of the © 1999 by CRC Press LLC FIGURE 10.12 Schematic diagram of the upgraded nanoindentation hardness apparatus with the tangential load cell assembly: IND, indenter probe; LC, normal load cell probe; TG, tangential load... 1992) A maximum of 12 segments can be programmed for an experiment After © 1999 by CRC Press LLC © 1999 by CRC Press LLC FIGURE 10.13 Schematics of the Nanoindenter II, (a) showing the major components — the indenter head, an optical microscope, and an X–Y–Z motorized precision table, (b) showing the details of indenter head and controls (microscope, which is directly behind the indenter, and the massive... multiple loadings and unloadings is to examine the reversibility of the deformation (hysteresis) and thereby making sure that the unloading data used for calculation of the modulus of elasticity are mostly elastic In some materials, there may be a significant amount of creep during the first unloading; thus, displacement recovered may not be entirely elastic, and because of this, the use of first unloading... under constant load, and when the drift rate becomes smaller than the user-prescribed maximum (usually 0.05 nm/s), the displacement of the indenter is recorded, establishing an initial estimate of the elevation of the sample surface The indenter is then raised to near the top of its travel using the coil/magnet assembly (the elevation of the table remains fixed for the rest of the experiment), and the... surface contact is made at the 13th or 14th data point from the end of the 50-data-point set The zero points for both load and displacement are then taken as the averages of the loads and displacements of 12th and 13th data sets from the end of the approach data For many materials this procedure identifies the sample surface to within 0.1 to 0.2 nm However, for very soft materials such as many polymers or... micro- and nanoscratch testers are commercially available, such as the Taber shear/scratch tester model 502 with a no 139-58 diamond cutting tool (manufactured by Teledyne Taber, North Tonawanda, NY) for thick films; Revetest automatic scratch tester (manufactured by Centre Suisse d’ Electronique et de Microtechnique S.A, CH-2007, Neuchatel, Switzerland) for thin films (Perry, 1981, 1983; Steinmann et al.,... Commercial Depth-Sensing Nanoindentation Hardness Apparatus and Its Modifications 10.2.3.1 General Description and Principle of Operation Although the NEC Corp design and Micro Materials design presented in the previous section are commercially available, these are not popular The most commonly used commercial depth-sensing nanoindentation hardness apparatus is manufactured by MTS Nano Instruments Innovation... depth (hp), which is given by hp = hmax − Wmax Smax (10.3b) We note that Doerner and Nix (1986) had underestimated hc by assuming that hc = hp Based on the finite element analysis of the indentation process, Laursen and Simo (1992) showed that hc cannot be assumed equal to hp for indenters which do not have flat punch geometry © 1999 by CRC Press LLC FIGURE 10.22 Schematic of an indenter tip with a nonideal... Berkovich hardness HB (or HB) is defined as the load divided by the projected area of the indentation It is the mean pressure that a material will support under load From the indentation curve, we can obtain hardness at the maximum load as HB = Wmax A (10.5) where Wmax is the maximum indentation load and A is the projected contact area at the peak load The contact area at the peak load is determined by . resistance to local deformation. For example, with materials that go through plastic deformation, a hard indenter is pressed into the surface and the size of the permanent (or plastic) indentation. hardness. With rubberlike materials (which do not go through plastic deformation), an indenter is pressed into the material and how far it sinks under load is measured. With brittle materials (which do. is appreciably higher than the uniaxial flow stress of the materials. For many materials, it is about three times as large, but if the material shows appreciable elasticity, the yielding of the

Ngày đăng: 04/07/2014, 07:20