1. Trang chủ
  2. » Tất cả

(Logic vòi đốt)TB2-SDC.VP101-01100-I-M1A-DLG-5012 Rev1

52 0 0

Đang tải... (xem toàn văn)

Tài liệu hạn chế xem trước, để xem đầy đủ mời bạn chọn Tải xuống

THÔNG TIN TÀI LIỆU

Thông tin cơ bản

Tiêu đề Burner Management System Logic Diagram
Tác giả S. Li, X.F Chen, Y.S Liu, Y.J Luo
Trường học Vietnam Oil And Gas Group (PVN)
Chuyên ngành Thermal Power Engineering
Thể loại document
Năm xuất bản 2016
Thành phố Vietnam
Định dạng
Số trang 52
Dung lượng 4,73 MB

Nội dung

DOCUMENT SUBMISSION STATUS: FF NOTE: 20 May 2016 For Final S LI X.F CHEN Y.S LIU Y.J LUO 04 Mar 2016 For Final S LI X.F CHEN Y.S LIU Y.J LUO REV DATE DESCRIPTION DRAWN CHECKED APPROVED APPROVED OWNER OWNER’S CONSULTANT VIETNAM OIL AND GAS GROUP (PVN) EPC CONTRACTOR PVPOWER PCC FICHTNER EPC CONSTRACTOR’S CONSULTANT PETROVIETNAM CONSTRUCTION JOINT STOCK CORPORATION (PVC) POWER ISLAND PACKAGE SUPPLIER WORLEYPARSONS DAELIM INDUSTRIAL CO., LTD SOJITZ CORPORATION PROJECT TITLE THAI BINH THERMAL POWER PLANT x 600MW DRAWING / DOCUMENT TITLE BURNER MANAGEMENT SYSTEM LOGIC DIAGRAM 12HJF20EB100 OIL IGNITER A2 GROUP BIP SUPPLIER: BABCOCK & WILCOX BEIJING COMPANY LTD DOCUMENT NO: TB2-SDC.VP101-01100-I-M1A-DLG-5012 FUNCTION NAME DRWN S LI 20 May 2016 CHKD X.F CHEN 20 May 2016 APPD Y.J LUO 20 May 2016 No of page: 35 SIGN Scale DATE Rev.1 Cover page / P.O NO 110180-1600-101-001-A01 ITEM NO ALL ITEM DESCRIPTION Boiler and Boiler BOP DOCUMENT NO TB2-SDC.VP101-01100-I-M1A-DLG-5012 DOCUMENT TITLE BURNER MANAGEMENT SYSTEM LOGIC DIAGRAM 12HJF20EB100 OIL IGNITER A2 GROUP REV NO Daelim's Approval Status Daelim Industrial Co., Ltd Job No 110180 A - APPROVED B - APPROVED WITH COMMENTS C - RETURNED FOR CORRECTION D - REJECTED N - NOT APPLICABLE(REFERENCE ONLY) SIGNED BY : DATE : DIC'S PERMISSION TO PROCEED OR REVIEW TAKEN ON VENDOR PRINTS SHALL NOT RELIEVE VENDOR FROM ITS RESPONSIBILITIES OR LIABILITIES UNDER THE PURCHASE ORDER BIP SUPPLIER: BABCOCK & WILCOX BEIJING COMPANY LTD Cover page / Document Review Comment Sheet Daelim's Ref No No : TB2-DIC-BWBC-T-3068 Document No Rev TB2-SDC.VP101-01100-I-M1A-DLG-5012 TB2-SDC.VP101-01100-I-M1A-DLG-5013 TB2-SDC.VP101-01100-I-M1A-DLG-5014 TB2-SDC.VP101-01100-I-M1A-DLG-5015 TB2-SDC.VP101-01100-I-M1A-DLG-5016 TB2-SDC.VP101-01100-I-M1A-DLG-5017 TB2-SDC.VP101-01100-I-M1A-DLG-5018 TB2-SDC.VP101-01100-I-M1A-DLG-5019 TB2-SDC.VP101-01100-I-M1A-DLG-5020 10 TB2-SDC.VP101-01100-I-M1A-DLG-5021 11 TB2-SDC.VP101-01100-I-M1A-DLG-5022 12 TB2-SDC.VP101-01100-I-M1A-DLG-5023 13 TB2-SDC.VP101-01100-I-M1A-DLG-5024 14 TB2-SDC.VP101-01100-I-M1A-DLG-5025 15 TB2-SDC.VP101-01100-I-M1A-DLG-5026 16 TB2-SDC.VP101-01100-I-M1A-DLG-5027 17 TB2-SDC.VP101-01100-I-M1A-DLG-5028 Title BURNER MANAGEMENT SYSTEM LOGIC DIAGRAM 12HJF20EB100 OIL IGNITER A2 GROUP BURNER MANAGEMENT SYSTEM LOGIC DIAGRAM 12HJF09EB100 OIL IGNITER A3 GRUOP BURNER MANAGEMENT SYSTEM LOGIC DIAGRAM 12HJF12EB100 OIL IGNITER A4 GRUOP BURNER MANAGEMENT SYSTEM LOGIC DIAGRAM 12HJF16EB100 OIL IGNITER B1 GRUOP BURNER MANAGEMENT SYSTEM LOGIC DIAGRAM 12HJF19EB100 OIL IGNITER B2 GRUOP BURNER MANAGEMENT SYSTEM LOGIC DIAGRAM 12HJF10EB100 OIL IGNITER B3 GRUOP BURNER MANAGEMENT SYSTEM LOGIC DIAGRAM 12HJF13EB100 OIL IGNITER B4 GRUOP BURNER MANAGEMENT SYSTEM LOGIC DIAGRAM 12HJF15EB100 OIL IGNITER C1 GRUOP BURNER MANAGEMENT SYSTEM LOGIC DIAGRAM 12HJF18EB100 OIL IGNITER C2 GRUOP BURNER MANAGEMENT SYSTEM LOGIC DIAGRAM 12HJF11EB100 OIL IGNITER C3 GRUOP BURNER MANAGEMENT SYSTEM LOGIC DIAGRAM 12HJF14EB100 OIL IGNITER C4 GRUOP BURNER MANAGEMENT SYSTEM LOGIC DIAGRAM 12HJF23EB100 OIL IGNITER D1 GRUOP BURNER MANAGEMENT SYSTEM LOGIC DIAGRAM 12HJF26EB100 OIL IGNITER D2 GRUOP BURNER MANAGEMENT SYSTEM LOGIC DIAGRAM 12HJF03EB100 OIL IGNITER D3 GRUOP BURNER MANAGEMENT SYSTEM LOGIC DIAGRAM 12HJF06EB100 OIL IGNITER D4 GRUOP BURNER MANAGEMENT SYSTEM LOGIC DIAGRAM 12HJF22EB100 OIL IGNITER E1 GRUOP BURNER MANAGEMENT SYSTEM LOGIC DIAGRAM 12HJF25EB100 OIL IGNITER E2 GRUOP Purpose Approval Status FF B FF B FF B FF B FF B FF B FF B FF B FF B FF B FF B FF B FF B FF B FF B FF B FF B 18 TB2-SDC.VP101-01100-I-M1A-DLG-5029 19 TB2-SDC.VP101-01100-I-M1A-DLG-5030 20 TB2-SDC.VP101-01100-I-M1A-DLG-5031 21 TB2-SDC.VP101-01100-I-M1A-DLG-5032 22 TB2-SDC.VP101-01100-I-M1A-DLG-5033 23 TB2-SDC.VP101-01100-I-M1A-DLG-5034 BURNER MANAGEMENT SYSTEM LOGIC DIAGRAM 12HJF04EB100 OIL IGNITER E3 GRUOP BURNER MANAGEMENT SYSTEM LOGIC DIAGRAM 12HJF07EB100 OIL IGNITER E4 GRUOP BURNER MANAGEMENT SYSTEM LOGIC DIAGRAM 12HJF21EB100 OIL IGNITER F1 GRUOP BURNER MANAGEMENT SYSTEM LOGIC DIAGRAM 12HJF24EB100 OIL IGNITER F2 GRUOP BURNER MANAGEMENT SYSTEM LOGIC DIAGRAM 12HJF05EB100 OIL IGNITER F3 GRUOP BURNER MANAGEMENT SYSTEM LOGIC DIAGRAM 12HJF08EB100 OIL IGNITER F4 GRUOP Daelim's Comments No FF B FF B FF B FF B FF B FF A Vendor’s Response I General comments If flame on signal is disappeared after step 7, the oil gun inlet oil valve will be safety close " OIL BURNER IGNITION FAILED" alarm will be indicated on VDU, and the oil burner If flame on signal is disappeared after step 7, what happe to sequence ? shutdown sequence will be auto start Feedback conditions should be included feedback for command as well as all Noted The feedback condition is included feedback for command as well as all essential essential condition This comment is applied to all burner sequence condition Based on the logic, each oil burner is sequentially started (A1 -> A4 -> A2->A3) If the A1 burner is flame off during A2 ignition, the A1 oil burner will be tripped,"A1 OIL regarding this concept, if the A1 burner is flame off during A2 ignition, what is BURNER IGNITION FAILED" alarm will be indicated on VDU It don't affect the A2 oil the follwing action? burner startup sequence The operator shall check and clean fault of the A1 oil gun, and start the A1 oil burner again II Detail comments TB2-SDC.VP101-01100-I-M1A-DLG-5012 2.1 See General Comments Noted TB2-SDC.VP101-01100-I-M1A-DLG-5013 2.2 See General Comments Noted TB2-SDC.VP101-01100-I-M1A-DLG-5014 2.3 See General Comments Noted TB2-SDC.VP101-01100-I-M1A-DLG-5015 2.4 See General Comments Noted TB2-SDC.VP101-01100-I-M1A-DLG-5016 2.5 See General Comments Noted TB2-SDC.VP101-01100-I-M1A-DLG-5017 2.6 See General Comments Noted TB2-SDC.VP101-01100-I-M1A-DLG-5018 2.7 See General Comments Noted TB2-SDC.VP101-01100-I-M1A-DLG-5019 2.8 See General Comments Noted TB2-SDC.VP101-01100-I-M1A-DLG-5020 2.9 See General Comments Noted TB2-SDC.VP101-01100-I-M1A-DLG-5021 2.10 See General Comments Noted TB2-SDC.VP101-01100-I-M1A-DLG-5022 2.11 See General Comments Noted TB2-SDC.VP101-01100-I-M1A-DLG-5023 2.12 See General Comments Noted TB2-SDC.VP101-01100-I-M1A-DLG-5024 2.13 See General Comments Noted TB2-SDC.VP101-01100-I-M1A-DLG-5025 2.14 See General Comments Noted TB2-SDC.VP101-01100-I-M1A-DLG-5026 2.15 See General Comments Noted TB2-SDC.VP101-01100-I-M1A-DLG-5027 2.16 See General Comments Noted TB2-SDC.VP101-01100-I-M1A-DLG-5028 2.17 See General Comments Noted TB2-SDC.VP101-01100-I-M1A-DLG-5029 2.18 See General Comments Noted TB2-SDC.VP101-01100-I-M1A-DLG-5030 2.19 See General Comments Noted TB2-SDC.VP101-01100-I-M1A-DLG-5031 2.20 See General Comments Noted TB2-SDC.VP101-01100-I-M1A-DLG-5032 2.21 See General Comments Noted TB2-SDC.VP101-01100-I-M1A-DLG-5033 2.22 See General Comments Noted TB2-SDC.VP101-01100-I-M1A-DLG-5034 2.23 See General Comments * Legend Purpose: AP - For Approval RE - For Reference FF - For Final / FC - For Construction F - Final / AB - As Built INFO - For Information Noted Approval Status: A - Approved B - Approved with Comments C - Returned for Correction D - Rejected N - Reference Only IN COMING 2016.05.31 DEALIM

Ngày đăng: 01/04/2022, 11:56

w