air transport white paper progress report 2006

Cat 6 White Paper FINAL 8-15-02

Cat 6 White Paper FINAL 8-15-02

Ngày tải lên : 16/10/2013, 05:15
... Participant ** TIA Engineering Committee Participant Only The TIA press release following this white paper contains additional information on the publica- tion of ANSI/TIA-568-B.2-1. Also attached ... external noise, provides the potential for category 6 to support multi-gigabit applications. This white paper provides an update on category 6 cabling and applications stan- dards together with references ... 6 Cabling: A Standards and Systems Overview 1 About the Category 6 Initiative The following white paper was produced by participants of the Category 6 Consortium. This con- sortium — focused...
  • 9
  • 426
  • 0
Tài liệu KRONE - White Paper - 10GBase-T Impossible is possible doc

Tài liệu KRONE - White Paper - 10GBase-T Impossible is possible doc

Ngày tải lên : 10/12/2013, 02:15
... noise measured on a pair within a cable induced from the pairs in an adjacent cable. This is not only a concern for different twist lay pairs between cables, but more so between same twist lay pairs between ... distance from one another than in the past. Similar to KRONE’s patented AirES ® technology cable design, air is used between these pairs. This effect is even more dramatic when viewed from the side ... Gigabit, 100m UTP problem. Addressing Pair Separation With standard Category 6 cable construction the pair separation within the cable is counter productive for pair separation between cables. The...
  • 4
  • 285
  • 0
Tài liệu KRONE - White paper - ADSL Service Delivery - 2003 pptx

Tài liệu KRONE - White paper - ADSL Service Delivery - 2003 pptx

Ngày tải lên : 10/12/2013, 02:15
... Inc. Preface This white paper analyzes several methods of connecting a Digital Subscriber Line Access Multiplexer (DSLAM; and splitter) to the outside plant. Analyzed methods include dedicated pair count, ... ADSL input/output and blocks for the pair- gain/cable pair appearances. Every one of the dial-tone circuits appear in this special cabinet. Each of the pair-gain terminal blocks is equipped with ... equipped with small straps that connect through the dial- tone to the cable pair. Basically the pair-gain and cable pair appearances within the wire management cabinet are positioned between the...
  • 8
  • 398
  • 0
Tài liệu KRONE - White Paper - A-Tick, the new ACA Standard Compliance pptx

Tài liệu KRONE - White Paper - A-Tick, the new ACA Standard Compliance pptx

Ngày tải lên : 10/12/2013, 02:15
... connected to the network. Consumers are also being warned that it Measuring Contact Resistance WHITE PAPER UNDERSTANDING A-TICK the new ACA standard By Peter Meijer Technical Training Manager JP,...
  • 4
  • 413
  • 0
Tài liệu KRONE - White Paper - Catching up with Truenet pptx

Tài liệu KRONE - White Paper - Catching up with Truenet pptx

Ngày tải lên : 10/12/2013, 02:15
... the ultimate question at hand. The KRONE white paper, Effects of Errors on TCP Performance provides some answers. To summarize the main conclusions of this very in-depth paper, we learn the following: · ... value of throughput performance to the overall operation of the LAN. In this paper, we will reference two companion papers, Network Troubleshooting Using TrueNet, and The Effect of Errors on ... system, much of the cabling industry has been involved in a game of follow-the-leader. Numerous papers have been published, alternative theories of measuring throughput performance have been advanced,...
  • 6
  • 311
  • 0
Tài liệu KRONE - White paper - Limitation of RJ21 in Ethernet pptx

Tài liệu KRONE - White paper - Limitation of RJ21 in Ethernet pptx

Ngày tải lên : 10/12/2013, 02:15
... standard (notice the orange and brown pair actually fall to 60 ohms!) When viewed in the frequency domain in figure 4, we see wild oscillations in the orange and brown pair, as we might have predicted ... has reported meeting the more stringent category 5e standard, which is now the de-facto minimum requirement for data (the TIA has dropped Category 5 from the standard). Furthermore, the 25 pair ... assemblies is not category 5e compliant either, nor has the TIA established a standard for 25 pair cables above category 5. Tempting as it may be to install this type of infrastructure for its...
  • 2
  • 377
  • 0
Tài liệu KRONE - White paper - LSA Plus Connectivity (Overview) - 2000 ppt

Tài liệu KRONE - White paper - LSA Plus Connectivity (Overview) - 2000 ppt

Ngày tải lên : 10/12/2013, 02:15
... G ENERAL I NFORMATION LSA-PLUS Series 2 Connection, Disconnection and Switching Modules for 8 or 10 pairs: - for fitting on Back Mount Frames of varying capacity (standard-program) - for fitting on...
  • 7
  • 402
  • 0
Tài liệu KRONE - White Paper - Open the Pipe for Broadband service doc

Tài liệu KRONE - White Paper - Open the Pipe for Broadband service doc

Ngày tải lên : 10/12/2013, 02:15
... local loop • Subscriber Interface Solutions PremisNET Customer PremisNET Customer AccessNET DigiNET Transport Local Loop Delivery Local Loop Delivery ...
  • 8
  • 423
  • 0
Tài liệu ADC KRONE - White Paper - Data Center - 3 principles of Data Center Infrastructure Design (with n pptx

Tài liệu ADC KRONE - White Paper - Data Center - 3 principles of Data Center Infrastructure Design (with n pptx

Ngày tải lên : 10/12/2013, 03:15
... foreign patents. An Equal Opportunity Employer 102261AE 4/06 Original © 2006 ADC Telecommunications, Inc. All Rights Reserved WHITE PAPER The Three Principles of Data Center Infrastructure Design Page ... faults, it’s paramount that more consideration be given to infrastructure design. Within this white paper we introduce three principles, that when executed properly, will help you gain significant ... leave more room for flexible reconfiguration and growth. Figure 1. Data Center with Flexible White Space Principle 2: Reliability Uninterrupted service and continuous access are critical to...
  • 8
  • 523
  • 0
Tài liệu KRONE - White paper - Patch By Exception doc

Tài liệu KRONE - White paper - Patch By Exception doc

Ngày tải lên : 10/12/2013, 03:15
... White Paper on Patch By Exception Page 1 Rev.4 Jan.2003 White Paper on Patch By Exception Page 4 Rev.4 Jan.2003 who have excellent ... same manner voice services are almost always provided at every workstation and in every room. White Paper on Patch By Exception Page 2 Rev.4 Jan.2003 ... provide a permanent service to a workstation rather than to an individual. As technology has progressed and the cost of Hub ports and computers have dropped in price, the provision for computer...
  • 4
  • 412
  • 0
Tài liệu KRONE - White paper - Patch by exception Solution pdf

Tài liệu KRONE - White paper - Patch by exception Solution pdf

Ngày tải lên : 10/12/2013, 03:15
... distributor inside the telecommunications room is terminated on disconnection modules, either 8-pair or 25-pair. Referring to Figure 2, one vertical column of disconnection modules, the network switch ... The 4-pair patch cord will move all signals from one work area to another in a matter of seconds (see Figure 2). Figure 2: When terminating the cable side of the module, make each 4-pair group ... which is located beside the first vertical column. The technicians simply terminate a series of 4-pair cables known as " jumpered cross-connects" on to the disconnection modules to complete...
  • 6
  • 419
  • 0
Tài liệu KRONE - White paper - PBE - HIGHBAND for Data Centers pptx

Tài liệu KRONE - White paper - PBE - HIGHBAND for Data Centers pptx

Ngày tải lên : 20/12/2013, 22:15
... specifying KRONE’s Ultim8 blocks exclusively. The advantages of this con- figuration include increased pair separation at termina- tion, more throughput and a reduction in attenuation. Chris Hutchison,...
  • 4
  • 361
  • 0

Xem thêm