AS/ACIF S009:2001 Amdt No. 1/2002
AUSTRALIAN COMMUNICATIONS INDUSTRY FORUM
Amendment No. 1/2002
to
AS/ACIF S009:2001
Installation requirements for customer cabling (Wiring Rules)
REVISED TEXT
The 2001 edition of AS/ACIF S009 is amended as follows; the amendments should be inserted in the
appropriate places.
SUMMARY: This Amendment applies to Clauses 5.5.3.4
Published 9 December 2002.
Approved for publication on 6 December 2002.
Gazetted on 18 December 2002 and commenced on that day.
ISBN 1 74000 228 8
AMDT
No. 1
DEC.
2002
Page 36 Clause 5.5.3.4
Delete Clause 5.5.3.4 and replace with the following:
5.5.3.4 Cable type
5.5.3.4.1 Cable installed underground shall be compliant, underground cable
whether or not the cable is installed in conduit.
5.5.3.4.2 Underground cable installed after 1 January 2004 shall meet the
requirements of AS/ACIF S008.
5.5.3.4.3 Blown-fibre tube systems installed underground shall—
(a) be contiguous between access points;
(b) have access points appropriately located or sealed to prevent the
ingress of moisture; and
(c) be appropriately installed or plugged when entering a building to
prevent the passage of fluid or gas into the building from any pit or
access hole.
This Amendment forms part of the Standard on publication.
- End of Amendment No. 1-