1. Trang chủ
  2. » Công Nghệ Thông Tin

Tài liệu Datasheet - FO - Cable - N012CTSARM010 docx

8 194 0

Đang tải... (xem toàn văn)

THÔNG TIN TÀI LIỆU

Thông tin cơ bản

Định dạng
Số trang 8
Dung lượng 160,28 KB

Nội dung

TECHNICAL SPECIFICATION Central Tube, Single Jacket/Single Armor Cable P/N N012CTSARM010 1. SCOPE 1.1 Application This specification covers the general requirements for fiber optic telecommunication cables used for indoor/outdoor application. 1.2 Cable Description 1) PE Single Jacket/ Single Armor Single or Multi mode color-coded fibers, filled central tube, water blocking tape, corrugated steel tape, metallic external strength member and outer PE jacket 2. OPTICAL FIBER The optical geometrical and mechanical performance of the optical fiber shall be in accordance with Table 1 below. Table 1. The Optical, Geometrical and Mechanical Performance of the Single Mode Fiber ITEMS UNITS SPECIFICATION Attenuation dB/km ≤ 0.37 at 1310nm ≤ 0.22 at 1550nm Chromatic Dispersion ps/nm.km ≤ 3.2 at 1285nm ~ 1330nm ≤ 18 at 1550nm Zero Dispersion Wavelength nm 1300 ~ 1324 Zero Dispersion Slope ps/nm 2 .km ≤ 0.093 Cut-off Wavelength (λcc, 22m of a cabled fiber) nm ≤ 1270 Mode Field Diameter µm 9.3 ± 0.5 Mode Field Concentricity µm ≤ 0.8 Cladding Diameter µm 125 ± 1.0 Cladding Non-circularity % ≤ 1.0 Coating Diameter µm 245 ± 15 Proof Test kpsi ≥ 100 3. CABLE CONSTRUCTION The construction of the cable shall be in accordance with Table 2 below. Table 2. Construction of the Cable ITEMS DESCRIPTION Number of Fibers 2 ~ 24 Type of Fiber Single Mode 9/125um Loose Buffer Tube PBT (Polybutylene Terephthalate) Filling Compound in Central Tube Thixotropic Jelly Compound Water Blocking Material Water Swellable Tape Rip Cord Aramid ripcord (To provide easy cable entry) Strength Member Two Galvanized Steel Wire (180 degree apart) Material Steel Tape with Plastic Coating on Both Sides Armor Thickness Nom. 0.15mm (Steel Tape) Nom. 0.05mm (Plastic Coating) Material Black PE Outer Jacket Thickness Nom. 2.5mm 4. FIBER IDENTIFICATION The color code of the central tube and the individual fibers within central tube shall be in accordance with Table 3 below. Table 3. The Color Code of the Individual Fibers No. of Fibers Color No. of Fibers Color 1 Blue 13 Orange / Single Ring Stripe * 2 Orange 14 Green / Single Ring Stripe * 3 Green 15 White / Single Ring Stripe * 4 Brown 16 Yellow / Single Ring Stripe * 5 Grey 17 Pink / Single Ring Stripe * 6 White 18 Aqua / Single Ring Stripe * 7 Red 19 Orange / Double Ring Stripes ** 8 Black 20 Green / Double Ring Stripes ** 9 Yellow 21 White / Double Ring Stripes ** 10 Violet 22 Yellow / Double Ring Stripes ** 11 Pink 23 Pink / Double Ring Stripes ** 12 Aqua 24 Aqua / Double Ring Stripes ** * Single Ring Stripe ** Double Ring Stripes 5. PHYSICAL / MECHANICAL / ENVIRONMENTAL PERFORMANCE AND TESTS 5.1 Temperature Range For the cables covered by this specification, the following temperature ranges apply: Operation : -20°C to +60°C Installation : -5°C to +50°C Storage/Shipping : -25°C to +70°C 5.2 Mechanical and Environmental Performance of the Cable The mechanical and environmental performance of the cable shall be in accordance with Table 4 below. Unless otherwise specified, all attenuation measurements required in this section shall be performed at 1550nm for single mode fiber (SM) and at 1300nm for multi mode fiber (MM). (Black Intermittent Ring) (Black Intermittent Ring) Table 4. The Mechanical and Environmental Performance of the Cable ITEMS TEST METHOD AND ACCEPTANCE CRITERIA Tensile Loading And Bending Test # Test method: TIA/EIA-FOTP-33 Mandrel diameter: 30D (D = cable diameter) Tensile load: 1,800N for 1 hour # Acceptance Criteria Fiber strain: Less than 60% of the fiber proof strain Attenuation increment: ≤ 0.30 dB at 1300nm (MM) ≤ 0.20 dB at 1550nm (SM) Compressive Loading Resistance Test # Test method: TIA/EIA-FOTP-41 Applied load: 4400 N/100mm Duration of loading: 10 minutes # Acceptance Criteria Attenuation Increment: ≤ 0.10 dB (SM) ≤ 0.20 dB (MM) after the completion of the test Repeated Impact Test # Test method: TIA/EIA-FOTP-25 Height of impact: 150mm Drop hammer mass: 2.0kg No. of impact cycles: 20 cycles # Acceptance Criteria Attenuation Increment: ≤ 0.10 dB (SM) ≤ 0.20 dB (MM) after the completion of the test No jacket cracking and fiber breakage Cyclic Flexing Test # Test method: TIA/EIA-FOTP-104 Sheave diameter: 20D (D = cable diameter) No. of flexing cycles: 25 cycles Flexing speed: 30 cycles/minute # Acceptance Criteria Attenuation Increment: ≤ 0.10 dB (SM) ≤ 0.20 dB (MM) No jacket cracking and fiber breakage Table 5. The Mechanical and Environmental Performance of the Cable (continued) ITEMS TEST METHOD AND ACCEPTANCE CRITERIA Cable Twist Test # Test method: TIA/EIA-FOTP-85 Cable length twisted: 2m No. of twist cycles: 10 cycles Twist angle: ± 180˚ # Acceptance Criteria Attenuation Increment: ≤ 0.10 dB (SM) ≤ 0.20 dB (MM) No jacket cracking and fiber breakage Temperature Cycling Test # Test method: TIA/EIA-FOTP-3 Temperature cycling schedule : 23°C → -20°C → 65°C → -20°C → 65°C Soak time at each temperature: 24hours No. of cycles: 2 cycles # Acceptance Criteria Attenuation increment: ⋅ Average ≤ 0.05 dB/km (SM) ≤ 0.20 dB/km (MM) ⋅ Maximum ≤ 0.15 dB/km (SM) ≤ 0.30 dB/km (MM) Water Penetration Test # Test method: TIA/EIA-FOTP-82 Length of specimen: 3m Height of pressure head: 1m Test time: 24 hours # Acceptance Criteria No leakage through the open cable end Flammability Test (LSZH Jacket Cable only) # Test method and Acceptance Criteria The cable shall comply with IEC 332-1. 6. PACKING AND MARKING 6.1 Cable and Length Marking The jacket shall be indent-marked with white characters at intervals of one meter with following information. 1) KRONE 2) Cable type and fiber number 3) Name of the manufacturer 4) Year of manufacture 5) Length marking 6.2 Cable Re-marking The re-marking shall be indent-marked, preferably with yellow characters, on the outer cable sheath. Any cable that contains two sets of cable markings shall be marked to indicate the color of the marking to be used. 6.3 Cable Packing 6.3.1 Standard length of cable shall be 2000 m. Other cable length is also available if requested by customer. 6.3.2 Each length of the cable shall be wound on a separate wooden reel. 6.3.3 Both ends of the cable shall be sealed with suitable plastic caps to prevent the entry of moisture during shipping, handling and storage. 6.3.4 The cable ends shall be securely fastened to the reel to prevent the cable from becoming loose in transit or during placing operations. 6.3.5 The inner end of the cable is housed into a slot on the side of the reel without extra cable length for testing. 6.3.6 Circumference battens or wood-fiber board shall be secured with steel bands to protect the cable during normal handling and shipping. 6.4 Cable Reel 6.4.1 Details given below shall be distinctly marked on a weather proof materials on both outer sides of the reel flange: (1) KRONE (2) Length of cable in meters (3) Cable type and fiber counts (4) Gross weight in kilograms (5) Reel number (6) Year of manufacture (7) Arrow showing the direction the drum shall be rolled 6.4.2 The cable shall be wound on the reel designed to prevent damages during shipment and installation. 6.4.3 The arbor holes provided in the reels shall be at least 65 mm and at most 120 mm in diameter. The arbor hole on each flange shall be reinforced with a bearing plate. < Cross-sectional Drawing of Cable > == End of Specification == 24 Fibers Optical Fibers Jelly Compound Central Tube Steel Wire Water Blocking Tape Ripcord Corrugated Steel Armor Outer PE Jacket or LSZH Jacket . Environmental Performance of the Cable (continued) ITEMS TEST METHOD AND ACCEPTANCE CRITERIA Cable Twist Test # Test method: TIA/EIA-FOTP-85 Cable length. Environmental Performance of the Cable ITEMS TEST METHOD AND ACCEPTANCE CRITERIA Tensile Loading And Bending Test # Test method: TIA/EIA-FOTP-33 Mandrel

Ngày đăng: 24/01/2014, 02:20

w