Thông tin tài liệu
Mechanical & Environmental Characteristics
KRONE Fiber Optics Phone: 802.442.5411 Web: www.kroneamericas.com
Simplex, Duplex,
Zipcord and
2- & 4-Fiber
Distribution Cables
Plenum & Riser
(UL) Listed OFNP/OFNR
Product Features
■
Utilize 245/900 µm PVC buffer
■
All cables feature flame retardant
PVC jacket (OFNR/OFNP)
■
A KEVLAR
®
strength member
surrounds each fiber
■
All cables tested to EIA/TIA FOTP standards
■
Optimized for use in communication closet
patch cord assemblies
■
Zipcord design optimized to “un-zip”
Benefits
■
Tight buffer fibers are easy to strip
■
Optimized for standard single-fiber
and duplex connectors
■
Withstand installation through
tight bend radii
Test Single Fiber Duplex Cable Zipcord 2-Fiber Distribution 4-Fiber Distribution
Crush Resistance: EIA-FOTP-41A 400 N/cm 400 N/cm 400 N/cm 400 N/cm 400 N/cm
Impact Resistance: EIA-FOTP-25B 50 Impacts 100 Impacts 50 Impacts 500 Impacts 500 Impacts
Flexing: EIA-FOTP-104A 1000 Cycles 1000 Cycles 1000 Cycles 1000 Cycles 1000 Cycles
Maximum Pulling Load: EIA-FOTP-33A 400 Newtons 600 Newtons 400 Newtons 1800 Newtons 1800 Newtons
(89 lbs.) (134 lbs.) (89 lbs.) (400 lbs.) (400 lbs.)
Maximum Safe Operating Load: 100 Newtons 200 Newtons 100 Newtons 300 Newtons 300 Newtons
(22 lbs.) (44 lbs.) (22 lbs.) (67 lbs.) (67 lbs.)
Minimum Bend Radius:
At Max. Load: 6 cm (2.36″) 6 cm (2.36″) 6 cm (2.36″) 9 cm (3.54″) 9 cm (3.54″)
Unloaded: 3 cm (1.18″) 3 cm (1.18″) 3 cm (1.18″) 3 cm (1.18″) 3 cm (1.18″)
Maximum Vertical Rise: without support or 27.4 m 27.4 m 15.2 m — —
service loop (90 ft.) (90 ft.) (50 ft.)
(UL) Listed Type:
OFNP (Plenum): UL910, PTS Type Pass Pass Pass Pass Pass
OFNR (Riser): UL1666, IN Type Pass Pass Pass Pass Pass
Cable Knot Test: EIA-FOTP-87B Pass Pass Pass Passes @ 20°C Passes @ 20°C
Fiber Proof Test: 100 KPSI 100 KPSI 100 KPSI 100 KPSI 100 KPSI
High/Low Temp. Bend Test: EIA-FOTP-37A — — — Passes @ 0°C and 70°C Passes @ 0°C and 70°C
Cable Twist Test: EIA-FOTP-85A — — — 1000 Cycles 1000 Cycles
Operating Temperature: -20°C to +70°C -20°C to +70°C 0°C to +70°C -20°C to +70°C (OFNR) -20°C to +70°C (OFNR)
0°C to +70°C (OFNP) 0°C to +70°C (OFNP)
Storage Temperature (non-flexing): -40°C to +70°C -40°C to +70°C -40°C to +70°C -40°C to +70°C -40°C to +70°C -40°C to +70°C
Installation Temperature: 0°C to +70°C 0°C to +70°C 0°C to +70°C 0°C to +70°C 0°C to +70°C
50/125 Multimode 3.5/1.2
▲
2.6/0.6
▲
500/500
▲
50 ± 3 125 ± 2 0.200 ± 0.015
62.5/125 FDDI MM 3.5/1.5
▲
2.7/0.75
▲
160/500
▲
62.5 ± 3 125 ± 2 0.275 ± 0.015
62.5/125 Gigabit Multimode 3.5/1.5
▲
2.7/0.75
▲
200/500
▲
62.5 ± 3 125 ± 2 0.275 ± 0.015
100/140 MM 6.0/3.0
▲
4.5/2.0
▲
100/100
▲
100 + 3 140 + 4 0.290 ± 0.020
Single-mode 0.5/0.5
■
0.35/0.25
■
Mode Field 9.3 ± 0.5 125 ± 2.0 0.13
(SMF-28) Diameter @1300nm
Optical Specifications
Max. Typical
Guaranteed Core Clad
Attenuation Attenuation Minimum Diameter Diameter Numerical
Fiber Type (dB/km) (dB/km) Bandwidth (Microns) (Microns) Aperture
▲
Attenuation and Bandwidth values for Multimode: 850nm/1300nm
■
Attenuation and Bandwidth values for Single-mode: 1310nm/1550nm
TECHNICALDATA
FiberOptic
CABLING SYSTEMS
KRONE Fiber Optics Phone: 802.442.5411 Web: www.kroneamericas.com
Cable and Jacket specifications and ordering information
CABLE CABLE
CABLE NO. OF UL DIAMETER WEIGHT JACKET
PART Number TYPE FIBERS TYPE (inches) (mm) (Nom. lbs./km) TYPE
601PTSSFX Simplex 1 OFNP (Plenum) .095 2.40 24 Plenum PVC
602PTSDPX Duplex 2 OFNP (Plenum) .120 x .220 3.05 x 5.60 60 Plenum PVC
602PTSZCX Zipcord 2 OFNP (Plenum) .114 x .245 2.40 x 6.20 46 Plenum PVC
602PTSFDX 2-Fiber Distribution 2 OFNP (Plenum) .180 4.50 35 Plenum PVC
604PTDCBX 4-Fiber Distribution 4 OFNR (Riser) .180 4.50 35 Plenum PVC
601IN(S)SFX Simplex 1 OFNR (Riser) .116 2.95 24 PVC
602INDPX Duplex 2 OFNR (Riser) .165 x .295 4.20 x 7.50 60 PVC
602IN(S)ZCX Zipcord 2 OFNR (Riser) .114 x .245 2.90 x 6.20 46 PVC
602INFDX 2-Fiber Distribution 2 OFNR (Riser) .180 4.50 35 PVC
604INCBX 4-Fiber Distribution 4 OFNR (Riser) .180 4.50 40 PVC
Simplex
Duplex
2-Fiber Distribution
Zipcord
Effective date: 4/2000 Rev. 000. (File: 302-IN-ZC-XXX-1.6mm) Not a controlled document; subject to change without notice. Check with a factory representative before placing order.
KEVLAR
®
PVC Outer Jacket (OFNP/OFNR)
900 µm Buffered Optical Fiber
KEVLAR
®
PVC Jacket
(OFNP/OFNR)
900 µm Buffered
Optical Fiber
Sub-unit Jacket
PVC Outer Jacket
(OFNP/OFNR)
900 µm Buffered
Optical Fiber
Rip Cord
(indoor only)
KEVLAR
®
4-Fiber Distribution
Outer Jacket (OFNP/OFNR)
900 µm Buffered Optical Fiber
KEVLAR
®
PVC Outer Jacket (OFNP/OFNR)
900 µm Tight PVC Buffer
Optical Fiber
Coated Strength Member
KEVLAR
®
KEVLAR is a registered trademark of the DuPont Co.
TECHNICALDATA
X = Fiber type, substitute this symbol in part number for desired fiber type as follows:
10 = Single-mode; 50 = 50/125 G.I. Fiber; 62 = 62.5/125 G.I. FDDI Grade Fiber; 62G = 62.5/125 G.I. Gigabit Grade Fiber; LEAF = Corning LEAF™ Fiber.
Multimode riser and plenum cables are available in orange. Single-mode riser and plenum cables are available in yellow.
†
NR = Not Rated
FiberOptic
CABLING SYSTEMS
. Distribution 4-Fiber Distribution
Crush Resistance: EIA-FOTP-41A 400 N/cm 400 N/cm 400 N/cm 400 N/cm 400 N/cm
Impact Resistance: EIA-FOTP-25B 50 Impacts. EIA-FOTP-37A — — — Passes @ 0°C and 70°C Passes @ 0°C and 70°C
Cable Twist Test: EIA-FOTP-85A — — — 1000 Cycles 1000 Cycles
Operating Temperature: -2 0°C
Ngày đăng: 16/01/2014, 20:21
Xem thêm: Tài liệu Datasheet - FO - Cable - Fibre Distribution Cables pdf, Tài liệu Datasheet - FO - Cable - Fibre Distribution Cables pdf