Catalogue UPS SIEL evo HF 1000KW The SAFEPOWEREVOHF UPS is available in 1015203040801001502005001000 kW On Line double conversion technology. SafepowerEvoHF meeting the VFISS111 classification defined by IEC EN 620403.

TECHNICAL DATA SHEET OF SAFEPOWER EVO-HF 1000 KVA DESCRIPTIONS OF PRODUCT − Model UPS − Technology UPS − Capacity (kVA/ kW) ENVIRONMENTAL CONDITIONS − Room ambient temperature − Maximum operative temperature (without reduce capacity) − Recommended working temperature for optimum battery performance − Storage temperature Mechanical Characteristics − Dimensions [mm] ▪ Width ▪ Depth ▪ Height − Weight [Kg] − Ventilation) − Cabinet IP rating − Cable input − Colour Electrical data INPUT − Nominal voltage − Voltage range (without switching to battery power) − Nominal frequency − Input frequency tolerance − Total Harmonic distortion (THDi) − Power factor Safepower Evo-HF True 0nline Double Conversion 1000 (module 200 x 5) 0o to 40o C 40o C 20o to 25o C -25° up to +60 °C (UPS) -15° up to +40 °C (UPS with battery) 840 1050 1900 2300 Forced through internal fans (failure controlled) IP20 From the bottom/On the rear RAL 7016 phase wires plus PE 380-400-415 Vac 320 to 480 V at 100% of the load 240 to 480 V at 50% of the load 50 or 60 Hz 45 to 65 Hz (40 to 72 Hz is option) 2,5% (0 - 100% load) 0,99 (0 - 100% load) Programmable from to 125 seconds − Rectifier progressive start-up in steps of second (Power Walk-in duration) (standard disable) Programmable from to 120 seconds − Adjustable delay for the rectifier start up in steps of 1second (Power Walk-in start delay) (3 seconds by default) Electrical data DC BUSBAR AND BATTERY SET − Number of battery cells − Float voltage (2,27 V/el adjustable) − Boost voltage (2,4 V/el adjustable) − End of discharge voltage – load dependent (1,6 V/el adjustable) − Standard battery charger − Additional battery charger Electrical data INVERTER − Nominal power [kVA] − Active power PF [kW] − Nominal voltage − Static stability − Dynamic stability − Recovery Time within ± 1% − Voltage distortion with linear and distorting load (EN 62040-3) − Voltage phase Dissymmetry with balanced and unbalanced loads − Voltage phase shift with balanced and unbalanced loads − Crest factor (Ipeak/ Irms as per EN 62040-3) − Nominal frequency − Inverter frequency stability without by-pass supply synchronization − Rate of Frequency variation − Inverter Overload − Short circuit current − Efficiency on battery-operation 120 + 120 273 + 273 Vdc 288 + 288 Vdc 192+192 Vdc x 25 A (0 - 100% load) x 50 A (0 - 95% load) 1000 (5 x 200) 1000 (5 x 200) 380/400/415 Vac ± 1% ± 3% (resistive load) EN62040-3 class performance distorting load 20 ms In compliance with standard EN 62040-3, class ≤ 0,5% with linear load ≤ 3% with distorting load ± 1% / ± 2% 120 ± 1o 3:1 50 / 60 Hz ± 0,1Hz Hz/sec (adjustable from 0,5 to 2) >100% ÷ ≤ 103% infinite >103% ÷ ≤ 110% 60 >110% ÷ ≤ 125% 10 >125% ÷ ≤ 150% >150% ÷ ≤ 200% 0,5 sec >200% 0,2 sec 2,7 In for 200 ms + 1,5 x In for 300 ms >95,5 % Electrical data BY-PASS − Nominal voltage − Bypass voltage range − Nominal frequency − Bypass input frequency range − Max current in short circuit for: ▪ 20 ms (Tj 25°C) [A] ▪ 100 ms (Tj 25°C) [A] − Overload capability on bypass line Electrical data SYSTEM − AC/AC Efficiency (On line) – [%] ▪ 25% Load ▪ 50% Load ▪ 75% Load ▪ 100% Load − Auto-consumption: ▪ UPS on line mode without load [kW] ▪ UPS stand by without load [kW] − Efficiency with UPS in ECO mode ▪ Load 25% ▪ Load 100% − Audible noise at mt − Operating temperature − Max relative humidity during operation − Max installation altitude 380-400-415 Vac from 180 V to 264 V 50 to 60 Hz ± 5% (adjustable from 0,25 to 10%) 9300 6500 ≤ 110% infinito >110% ÷ ≤125% 60 >125 ÷ ≤150% 10 ≤ 1000% 100 million sec 95,6% 96,2% 96,1% 95,8% 1,5 0,4 98,9% 99,2% ≤ 70 @ On line mode ≤ 50 @ Eco mode ± 40 ºC ÷ 90% (without condensation) 1000 m at nominal power ... bypass line Electrical data SYSTEM − AC/AC Efficiency (On line) – [%] ▪ 25% Load ▪ 50% Load ▪ 75% Load ▪ 100% Load − Auto-consumption: ▪ UPS on line mode without load [kW] ▪ UPS stand by without... dependent (1,6 V/el adjustable) − Standard battery charger − Additional battery charger Electrical data INVERTER − Nominal power [kVA] − Active power PF [kW] − Nominal voltage − Static stability... >150% ÷ ≤ 200% 0,5 sec >200% 0,2 sec 2,7 In for 200 ms + 1,5 x In for 300 ms >95,5 % Electrical data BY-PASS − Nominal voltage − Bypass voltage range − Nominal frequency − Bypass input frequency

Ngày đăng: 13/10/2021, 14:29

TỪ KHÓA LIÊN QUAN