1. Trang chủ
  2. » Công Nghệ Thông Tin

Tài liệu ADC KRONE - Guide Book - FTTP - The Efficient Service Delivery Architecture for OSP network docx

8 329 0

Đang tải... (xem toàn văn)

THÔNG TIN TÀI LIỆU

Thông tin cơ bản

Định dạng
Số trang 8
Dung lượng 782,49 KB

Nội dung

OmniReach ™ : The Efficient Service Delivery Architecture for OSP Networks WHITE PAPER Current outside plant (OSP) networks, particularly those deploying fiber, were designed primarily with transport and backhaul in mind – a means to carry telecommunications traffic on and off a larger transport system and usually over long distances. There was little demand for actual service delivery to multiple end users, although an occasional large business customer might require as much as an OC-3 or OC-48, Megabit Ethernet, Fibre Channel, or other connection for day-to-day business operations. Times have changed. Today, fiber is being deployed much deeper into the network, both for business and residential consumers. The demand for high-speed voice, data, and video services is escalating, and new distribution architectures must be added to OSP networks to reach these customers. However, serving the small business and residential customer requires architecture that can efficiently connect millions of users onto a local network. Fiber-to-the-premises (FTTP) systems, based on passive optical network (PON) architecture, provide the access piece to traditional OSP networks for bringing multiple services to multiple business and residential customers. PON – Catalyst for the FTTP Revolution PON architectures are optical transmission systems designed to carry transmission signals via fiber-optic cable from the central office (CO) directly to the end user – such as a business, multi-tenant unit, or individual home. The network is passive because once the signal leaves the central office, there are no powered electronics or optical components involved. The signal is guided through the fiber to the end user by connecting and splitting components, traveling up to, and in some cases, exceeding 20 km. At the end user, the optical signal is converted back to electrical by an optical network terminal (ONT) for use as telephony, Internet, or video. OmniReach ™ : The Efficient Service Delivery Architecture for OSP Networks Feeder OSP Cable From C/O Central Office Splice Case Splice Case Fiber Distribution Terminal Drop Cable Drop Cable Fiber Access Terminal Distribution Cable Distribution Cable The Efficient Service Delivery Architecture for OSP Networks Page 2 Information from the end user flows from the premises back through the PON to the CO, using wavelength division multiplexing (WDM). WDM enables different wavelengths of light to be transmitted over a single fiber in either direction. PON offers distinct advantages over competing technologies because of its passive nature, such as eliminating the need for any electrical power unit. PON can function in the OSP under environmental extremes, and its low maintenance and data independent nature provides significant operational and upgrade cost benefits to telecom providers. A New Way of Thinking With the introduction of FTTP architectures comes a new set of issues and concerns to challenge networking engineers. Large-scale FTTP networks require providers to ask some tough questions about their traditional methods of building, operating, and maintaining the OSP network. Which overall design, particularly in terms of which splitter approach to use, will be most cost-efficient in a particular deployment scenario? Which will provide the necessary flexibility – connectorization or splicing? What components will provide the best performance? How many access points will be needed for testing and maintaining the system? How much training will technicians need to ensure proper cable management and slack storage? How does one deal with the new implications posed by FTTP for the central office? There are various answers for every decision. Choosing the wrong answer can be the difference between an efficient, revenue-generating network versus one that will constantly require upgrades and overhauls as demand and technology moves forward. ADC has introduced craft-friendly access networks based on many years of experience in addressing these and other concerns posed by customers. PON architectures require key decisions that depend heavily on service area considerations, such as physical proximity of end users and service take rates, to determine what components are optimal and their placement within the network. This paper will address pros and cons, as well as solutions, to the challenges faced by today’s forward-thinking service providers who view FTTP as the next major marketplace for increased revenues through superior service offerings. Higher OLT Efficiency is a ‘Splitter’ Decision There are two main approaches to FTTP optical splitters: centralized and cascaded. Through research, statistical data, and lessons learned, ADC has concluded that in most cases, a 1x32 centralized splitter configuration provides distinct advantages over a cascaded splitter approach. The first reason for choosing a centralized splitter approach is to obtain the highest possible efficiency of the optical line terminal (OLT) cards. Each PON card services a maximum of 32 end users, providing an optical signal to each ONT at the premises. A cascaded approach, however, requires dedication, or “hard-wiring,” of fibers to certain locations, leaving a real possibility of stranded connections whenever take rates are not high – making additional (and expensive) PON cards necessary. A centralized approach makes use of all 32 connections on each PON card, resulting in maximum efficiency and the need for fewer cards. Additionally, the 1x32 centralized splitter provides for a modular build that enables budgeting costs with revenue growth. Testing also becomes a challenge with a cascaded approach. To use an optical time-domain reflectometer (OTDR) for testing multiple splitters, each fiber must be characterized with certain identifiable traits for recognition by the OTDR. From a centralized point, it is also difficult to see through an array of splitters down individual fiber lengths. In a centralized system, all troubleshooting is done from a single, centralized point. A centralized splitter also provides better overall loss measurements compared to the cascaded approach. One argument for a cascaded splitter approach has traditionally been that it makes more sense in a very high take rate situation. Cable costs may be less since a 12- fiber cable used in the cascaded approach may substitute for the 72-fiber cable used in the centralized architecture. However, since the price differential is probably not excessive (glass is fairly inexpensive today) and holes are being dug to bury the cable anyway, why not put the higher fiber count in case future upgrades or additions become possible? The economies of gaining simpler testing ability will almost always outweigh any cost savings realized in using smaller fiber counts. The Efficient Service Delivery Architecture for OSP Networks Page 3 1x4 or 1x8 Splitter Central Office OSP Enclosure 1x4 or 1x8 Splitters 1x4 or 1x8 Splitters Central Office up to 1xN Splitter (N up to 32) FTTP Cascaded Optical Splitter Network Diagram FTTP Centralized Optical Splitter Network Architecture The Efficient Service Delivery Architecture for OSP Networks Page 4 Connectors vs. Splicing – A Common Sense Approach Reaps Big Benefits Another major consideration in building a cost efficient, flexible, distribution network is deciding when to splice and when to use connectors. A simple rule of thumb would be to splice connections that will remain permanent, and use connectors wherever a need for access may occur. Still, there are other factors to consider. Splicing may be preferable for distribution cables to achieve reasonable distances that can be easily and efficiently managed. Connectors, on the other hand, provide easy access for testing and troubleshooting. They also provide the network with considerably more flexibility in terms of making adjustments or changes during services provisioning. Traditional OSP networks used splicing exclusively as a means of interconnecting cables. However, where a distribution network is involved, splicing could be a very expensive and time-consuming operation. Since distribution networks require numerous connections for quickly turning up services to thousands of homes and businesses, connectors offer more flexibility and less personnel training to accomplish. The number of technicians and equipment required for multiple splicing operations should be considered. Finally, connectors enable easier access for troubleshooting and maintenance operations. They provide access at multiple points along the network and are certainly simpler than cutting into the cable to perform these same operations. The mythical “seamless” network may have appeared as a good solution for transport and backhaul operations, but with an access network, the ability to easily test and monitor is essential. Without seams provided by connectors, there is no access or ability to physically restore a network outside of cutting into the optical cable. The risk of inadvertent failure also increases when cutting and splicing cables, leaving a possibility of service interruption or failure to other customers while troubleshooting a problem in another area of the network. To most service providers, this is an unacceptable risk. • • • • • • • • • • • • • • • • • • • • Foreword Path 1xN Sp litter Bulkhead Plate Drop Cable OSP Cable From C/O Return Path 1xN Splitter Factory Terminated Connectors Factory Terminated Conne ctors Bulkhead Plate Splice Enclosure Bulkhead Plate Cross Connect Patch cords Enclosure FTTP Splitter Connector Access (Input and Output Connected) High Performance Components – Rain or Shine They Always Work The high-performance components used in ADC’s FTTP solution offer a wealth of robust features for exceptional reliability. The arguments that weather or other environmental conditions will weaken them is no longer valid. Components and connectors have evolved to the point where signal loss is minimal and life expectancy is at an all-time high, despite harsh environments and temperatures. A number of Telcordia studies have shown that connectors in the OSP performed quite well in a variety of outside environments. The bottom line is whether a slight loss is acceptable when the benefits, such as easy test access, faster turn up, and lower skill sets, are enhanced. Cable and cable assembly component shrinkage at low temperatures is a common cause of attenuation on OSP cable assemblies. If this shrinkage issue isn’t dealt with, optical fibers can fail at extreme cold temperatures. For ADC systems, only low-shrink plastic components are selected, and the fiber fanout and cable breakout assemblies are designed to accommodate disparate shrinkage rates between the different materials. This process enables the highest performance characteristics in ADC’s manufactured components – even in extreme temperatures. Picking Up the Slack in Cable Management Storing excess fiber cable is another area where most existing OSP fiber solutions run into cable management problems. Excess patch cord fiber is usually necessary for reconfiguring a fiber circuit, but the slack must be managed to prevent damage, yet remain accessible during day-to-day operations of the network. Accessibility and the amount of time required to reconfigure a network will be optimal in a system that maintains a continuous non-coiled or twisted routing of the fibers. A successful slack storage system such as ADC’s will provide flexible storage capacities, permanent bend radius protection, and easy access to individual fibers. The Efficient Service Delivery Architecture for OSP Networks Page 5 • • • • • • • • • • • • • • • • • • • • Foreword Path 1xN Sp litter Bulkhead Plate Drop Cable OSP Cable From C/O Return Path 1xN Splitter Splice Enclosure Splice Enclosure FTTP Splitter Connector Access (Input and Output Spliced) The Efficient Service Delivery Architecture for OSP Networks Page 6 Don’t Forget the Central Office Today’s FTTP networks will also have implications for the central office environment. For instance, where to place the WDM? There are advantages for placing the WDM inside the fiber distribution frame lineup as opposed to placing it beside the OLT equipment. There are also new considerations for fiber raceways and connector performance within this environment that will revolutionize the central office of tomorrow for FTTP. The same fiber management principles ADC has honed in the central office environment can be found within the cabinets – specifically, the Fiber Distribution Terminal. The Anatomy of a Revenue Generating Fiber Distribution Terminal ADC’s Fiber Distribution Terminals incorporate four time- tested elements that have already been demonstrated within central offices worldwide. Now ADC has evolved these elements into the OSP cabinet environment keeping the craft person in mind to ensure field products will perform with equal efficiency. These four specific elements, directly impacting the reliability, functionality, and operational cost of the network, are: bend radius protection, intuitive cable routing, easy fiber/connector access, and physical protection • Bend radius protection – Fibers bent beyond the specified minimum bend diameters can fracture, causing service failures and increasing network operations costs. Adding new fibers on top of previously installed fibers can easily bend the bottom fiber beyond its minimum bend radius and suddenly cause an increased level of attenuation and a shorter service life. By emphasizing fiber cable management, ADC provides bend radius protection at all points where a fiber cable is making a bend. This practice increases long-term reliability of the network, reduces network down time, and ultimately reduces the operating cost of the network. • Intuitive cable routing – Intuitive cable routing provides a very clear path for a craftsperson to route a particular cable, leaving fewer options and virtually eliminating the chance for human error. In addition, having defined routing paths makes accessing individual fibers much easier, quicker, and safer – reducing the time required for reconfigurations. Intuitive cable routing paths also reduce the training time required for technicians and make patch cord routing and rerouting a simpler operation. OLT Voice/ Data WDM OSP Cable To Network 1480nm 1550n m Splice Panel Termination Panel Cross-Connect Patch cord Equipment Patch cord OLT Video FTTP Central Office Fiber Network Architecture • Easy fiber/connector access – ADC’s fiber distribution terminals provide the ability to store unmated connector pairs in a “parking lot.” This parking lot is a key factor in maintaining connector cleanliness. The practice of scoping every single fiber as it is being cleaned can be both cumbersome and expensive. Because ADC places individually accessible connectors on both front and rear without the need for removing an entire panel, technicians have much easier access for cleaning operations to ensure optimal connector performance. From the time each unit is shipped from the factory, a dust cap protects every connector’s end face while it’s plugged into the parking lot. Superior fiber cable accessibility ensures that any fiber can be installed or removed without inducing a macrobend or otherwise damaging an adjacent fiber. • Physical protection – Physically protecting every fiber and connector from inadvertent damage is a major concern in cable management. ADC’s cabinet design ensures maximum protection for every optical cable and component. Fibers that are routed between pieces of equipment without proper protection are very susceptible to damage. A fiber cable management system should ensure the physical protection of every fiber. ADC is Answering the Tough FTTP Questions ADC provides efficient and flexible solutions for FTTP architectures to enable the distribution of triple-play services to multiple end users. Through innovative products and time-tested techniques, ADC is a leader in pushing the benefits of optical technology to everyone – at work or at home. ADC Telecommunications, Inc., P.O. Box 1101, Minneapolis, Minnesota USA 55440-1101 Specifications published here are current as of the date of publication of this document. Because we are continuously improving our products, ADC reserves the right to change specifications without prior notice. At any time, you may verify product specifications by contacting our headquarters office in Minneapolis. ADC Telecommunications, Inc. views its patent portfolio as an important corporate asset and vigorously enforces its patents. Products or features contained herein may be covered by one or more U.S. or foreign patents. An Equal Opportunity Employer 1288425 09/05 Revision © 2004, 2005 ADC Telecommunications, Inc. All Rights Reserved Web Site: www.adc.com From North America, Call Toll Free: 1-800-366-3891 • Outside of North America: +1-952-938-8080 Fax: +1-952-917-3237 • For a listing of ADC’s global sales office locations, please refer to our web site. WHITE PAPER . Cable The Efficient Service Delivery Architecture for OSP Networks Page 2 Information from the end user flows from the premises back through the PON to the. 32) FTTP Cascaded Optical Splitter Network Diagram FTTP Centralized Optical Splitter Network Architecture The Efficient Service Delivery Architecture for

Ngày đăng: 20/12/2013, 22:15

TÀI LIỆU CÙNG NGƯỜI DÙNG

TÀI LIỆU LIÊN QUAN