P P P r r r o o o d d d u u u c c c t t t D D D a a a t t t a a a S S S h h h e e e e e e t t t SIDNEY, NE (800) 272-9999 Issued: 03/12/02 Rev. 0 GIGABIT STRUCTURED WIRIN G PRODUCTS TRUEN ET™ CM Rated PAGE 1 OF 2 ORDERIN G IN FORMATION DIAMETER WEIGHT PRODUCT N UMBER N O. OF PAIRS IN CHES MM JACKET COLOR LBS/KFT KG/KM PACKAGIN G TN6TMT-XXII 4 .22 5.6 As specified 25 37.2 1,000’ Reelex NOTES: XX = Jacket color BL = Blue WT = White GY = Gray GN = Green YL = Yellow PK = Pink ____________________________________________________________________________________ CON STRUCTION : Conductors: 24 AWG Solid Bare Copper Separator: Polyolefin Tape Insulation: 100% Polyolefin Color Coding: Tight Lay System, Table 2 Pairing: Short, Staggered Pair Lays Jacket: Non-lead FR PVC _______________________________________________________________________________________ COMPLIAN CES: UL Subject 444 (UL)-C(UL) Type MP/CM ICEA S-90-661 NEC 800 Type CM TIA/EIA 568-B.2-1 Proposed Cat-6 Horizontal Cable Requirements NEMA WC 66-1999 ________________________________________________________________________________________ COMMON APPLICATION S: POTS 100BASE-T4 (Fast Ethernet) T1 & T1 Fractional 100VG-AnyLAN (IEEE 802.12) ISDN Basic & Primary Rate 100BASE-T (Fast Ethernet) 4/16 Mbps Token Ring (IEEE 802.5) 622 Mbps ATM (ATM Forum) 10BASE-T (IEEE 802.3) 1 Gbps Networking System (WGNA) 100 Mbps TP-PMD 1 Gbps Ethernet (IEEE 802.3) 52/155 Mbps ATM (ATM Forum) 1.2 Gbps ATM (ATM Forum) 77 Channel Broadband Video ________________________________________________________________________________________ ELECTRICAL CHARACTERISTICS: - Conductor DC Resistance (Max): 28.6 Ohms/1000 ft. @ 20 o C - DC Resistance Unbalance (Max): 5% - Insulation Resistance (Min): 500 Megohms/1000 ft. @ 20 o C - Mutual Capacitance (Typical): 15 pF/ft - Operating Temperature (Max): 60 o C - Operating Voltage (Max): 300 VDC - Worst Case Cable Skew: 45 nsec/100 meters - Nominal Velocity of Propagation: 70% - Differential Characteristic Impedance 5 Ohms [Max Pair Char. Imp.(f) – Min Pair Char. Imp.(f), where f is frequency in MHz] P P P r r r o o o d d d u u u c c c t t t D D D a a a t t t a a a S S S h h h e e e e e e t t t SIDNEY, NE (800) 272-9999 Issued: 03/12/02 Rev. 0 GIGABIT STRUCTURED WIRIN G PRODUCTS TRUEN ET™ CM Rated PAGE 2 OF 2 ELECTRICAL CHARACTERISTICS (Con’t.) IMPEDAN CE ATTEN UATION RETURN ATTEN UATION -TO-N EXT RATIO FREQ Ohms dB LOSS Pair-To-Pair Power Sum (MHz) Characteristic Input (Max) dB (Min) dB/100m (Min) dB/100m (Min) 1 100 +/-6 100 +/-15 2.0 20.0 73.3 70.3 4 100 +/-6 100 +/-15 3.8 23.6 62.5 59.5 8 100 +/-6 100 +/-15 5.3 25.4 56.5 53.5 10 100 +/-6 100 +/-15 6.0 26.0 54.3 51.4 16 100 +/-5 100 +/-15 7.6 26.0 49.7 46.8 20 100 +/- 5 100 +/-15 8.5 26.0 47.3 44.3 25 100 +/- 4 100 +/-15 9.5 25.5 44.8 41.8 31.25 100 +/-4 100 +/-15 10.7 25.0 42.2 39.2 62.5 100 +/-3 100 +/-15 15.4 23.5 33.0 30.0 100 100 +/-3 100 +/-15 19.8 22.5 25.5 22.5 200 100 +/-3 100 +/-22 29.0 21.0 11.8 8.9 250 100 +/-3 100 +/-32 32.8 20.5 6.5 3.5 N EXT ELFEXT FREQ Pair-To-Pair Power Sum Pair-To-Pair Power Sum (MHz) dB/100m (Min) dB/100m (Min) dB/100m (Min) dB/100m (Min) 1 75.3 70.3 67.8 65.8 4 66.3 59.5 55.7 53.7 8 61.8 53.5 49.7 47.7 10 60.3 51.4 47.8 45.8 16 57.3 46.8 43.7 41.7 20 55.8 44.3 41.7 39.7 25 54.3 41.8 39.8 37.8 31.25 52.9 39.2 37.9 35.9 62.5 48.4 30.0 31.8 29.8 100 45.3 22.5 27.8 25.8 200 40.8 8.9 21.7 19.7 250 39.3 3.5 19.8 17.8 NOTE: The above listed discrete frequency electrical performance values are provided for engineering information only. Actual compliance testing is based on swept frequency measurements. . + / -6 100 + /-1 5 3.8 23 .6 62.5 59.5 8 100 + / -6 100 + /-1 5 5.3 25.4 56. 5 53.5 10 100 + / -6 100 + /-1 5 6. 0 26. 0 54.3 51.4 16 100 + /-5 100 + /-1 5 7 .6 26. 0 49.7 46. 8. (UL)-C(UL) Type MP/CM ICEA S-9 0 -6 61 NEC 800 Type CM TIA/EIA 568 -B. 2-1 Proposed Cat- 6 Horizontal Cable Requirements NEMA WC 6 6-1 999 ________________________________________________________________________________________