S ONEPLEX ® L OOP E XTENDER S YSTEM The Soneplex System from ADC. The T1/E1 Service Delivery Experts The Soneplex Loop Extender system is an efficient, cost-effective solution for T1-based service delivery. It supports DS1 network interfaces and up to 28 DS1 loop transport modules. Integrated network management lets carriers save on overall operations costs through the entire system lifecycle. ADC’s Soneplex system is the lowest total cost solution for carriers to grow their T1-based business services. Focused on providing flexible, end- to-end solutions, the Soneplex system saves carriers money on T1- based services over copper or fiber, using HDSL, HDSL2, ADSL, traditional T1 repeater or optical DS2 technology, in a single platform. From operations, maintenance, provisioning and high-speed backbone connections to central office space and cabling, the Soneplex system is designed to take costs out of today’s T1 delivery approach, adding profit to your bottom line. FEATURES • Cost-effective DS1 network connection • Delivers T1s using HDSL, HDSL2, repeated T1, and optical DS2 • Supports TL1 over X.25 and TCP/IP, TBOS and SNMP protocols for flexible alarm management, per-circuit visibility and provisioning • Full carrier-class functionality and hardened design • NEBS certified; completed OSMINE process 212/98 473 Soneplex ® Loop Extender System The Soneplex Loop Extender system is ideal for a variety of applications including point- to-multipoint hubs, outside plant applications, building or campus service distribution, and cellular transport-site feeds. The system accepts up to 28 electrical DS1 feeds – from a multiplexer, digital cross-connect system (DCS) or other network device – and distrib- utes them over copper or fiber facilities from a single chassis. The Soneplex Loop Extender system provides local loop distribution of up to 28 DS1 signals using a variety of transmission technologies. DS1 transport over fiber utilizes optical DS2 modules to carry four DS1 signals to a remote location. For copper-based DS1 transport, the Soneplex Loop Extender can use standard T1 repeater, HDSL, or HDSL2 modules, LAN Extension modules or ADSL modules. Each system is also equipped with a Main Processor Unit (MPU) or Shelf Controller Unit (SCU) and an Alarm Processor Unit (APU) for total control over the transport network. Description RLX 3 CENTRAL OFFICE HDSL2 T1 REPEATER OPTICAL DS2 CUSTOMER PREMISES 28 DS1s DS1 1 SONEPLEX LOOP EXTENDER H2LXR CUSTOMER PREMISES NIU CUSTOMER PREMISES QLX CORE NETWORK CUSTOMER PREMISES HLXR HDSL 312/98 473 Soneplex ® Loop Extender System The standard 23-inch Soneplex Loop Extender system accepts electrical DS1 network input and distributes up to 28 DS1 circuits over copper or fiber facilities. The manage- ment and maintenance section consists of an MPU or SCU and APU, and supports telemetry byte oriented serial (TBOS), transaction language 1 (TL1) and simple network management protocol (SNMP) for remote connection to an operations support system (OSS). It also supports a menu-driven craft interface and X.25 and alarm contact closure interfaces. System Overview 23" Soneplex Loop Extender Chassis 19" Soneplex Loop Extender Chassis The 19-inch Soneplex Loop Extender system accepts electrical DS1 network input and distributes up to 20 DS1 circuits over copper or fiber facilities. Ideal for PCS or cellular applications, the 19-inch Soneplex Loop Extender chassis saves valuable real estate. The management and maintenance section consists of an MPU or SCU and APU, and sup- ports TBOS, TL1 and SNMP for remote connection to an OSS. It also supports a menu- driven craft interface and X.25 and alarm contact closure interfaces. Specifications Dimensions (HxWxD): Weight: Power Feeds: Mounting Options: Common Modules: DS1 Capacity: Modules Supported: 6" x 23" x 12" (15.2 x 58.4 x 30.5 cm) 19 lbs (7.07 kg) -48 VDC A and B 23" WECO or EIA rack 2" or 5" recess MPU or SCU, APU 28 RLX (28); HLX (28); Unprotected QLX (7); Protected QLX (14); LAN (28); ALX (28) Specifications Dimensions (HxWxD): Weight: Power Feeds: Mounting Options: Common Modules: DS1 Capacity: Modules Supported: 6" x 19" x 12" (15.2 x 48.3 x 30.5 cm) 16 lbs (5.97 kg) -48 VDC A and B 19" WECO or EIA rack 2" or 5" recess MPU or SCU, APU 20 RLX (20); HLX (20); Unprotected QLX (5); Protected QLX (10); LAN (20); ALX (20) 412/98 473 Soneplex ® Loop Extender System Main Processor Unit The Main Processor Unit (MPU) provides extensive network management for system configuration, remote provisioning, maintenance, circuit visibility and performance monitoring. It collects and reports the performance monitoring information to an OSS via a TL1/X.25 or TBOS connection for centralized management and system control. The MPU contains FLASH memory for software upgrade capability. Specifications Dimensions (HxWxD): Weight: Power Consumption: Management Interfaces Front Panel Craft Port: Remote Access Port: TBOS Connections: 4.88" x .69" x 9.75" (12.4 x 1.75 x 24.8 cm) .53 lb. (.24 kg) 5.0 watts, maximum RS232C/DB9; ASCII to VT100 terminal RS232C/DB25; ASCII or X.25 RS422/wire-wrap The Shelf Controller Unit (SCU) provides extensive network management for system configuration, remote provisioning and circuit visibility. The SCU adds SNMP capability while supporting standard TL1 commands over TCP/IP. Configuration data is stored on the module and may be uploaded or down- loaded. Front panel access provides craft control and remote connections that can be made through a modem network. An optional graphical user interface (GUI) element management system is available for stand-alone operation for integration into a network management system. Specifications Dimensions (HxWxD): Weight: Power Consumption: Management Interfaces Front Panel Craft Port: Remote Access Port: SNMP Access Port: 4.7" x .7" x 9.8" (12 x 1.7 x 24.8 cm) .4 lb. (.2 kg) 5.0 watts, maximum RS232C/DB9; ASCII to VT100 terminal RS232C/DB25; ASCII or PPP Ethernet/RJ45 or wire-wrap; SNMP Shelf Controller Unit The SCU Element Manager is a Java-based SNMP graphical user interface (GUI). The Soneplex EMS software operates on Windows NT ® or Sun Solaris ™ based systems. The Soneplex EMS can be used as a stand-alone application or can be integrated with HP OpenView Network Node Manager software. The Soneplex SNMP EMS reduces staff training and maintenance and test capabilities through an easy to use point-and click graphical interface. Specifications PC: Sun UNIX: Pentium 100 MHz processor Windows NT ® Minimum release 4.0, 64 MB RAM HP OpenView Network Node Manager for PC Windows NT ® Minimum release 5.2 SPARC 5 Workstation Sun Solaris ™ Minimum release 2.51, 128 MB RAM HP OpenView Network Node Manager for Sun Solaris ™ Minimum release 5.01 SCU Element Management System Software 512/98 473 Soneplex ® Loop Extender System Soneplex Loop Extender Chassis 23 inch rack mount 19 inch rack mount Main Processor Unit Shelf Controller Unit SCU Element Manager System Software Alarm Processor Unit Heat Baffle/Cable Management Panel 23 inch rack mount 19 inch rack mount Description Catalog Number SPX-FRM1A2 SPX-FRM2A1 SPX-MPU0A521 SPX-SCU0A1 SPX-SCUEMS0A1 SPX-APU0B1 SPX-BAFF1A1 SPX-BAFF2A1 Ordering Information Alarm Processor Unit The Alarm Processor Unit (APU) provides alarm reporting and performance monitoring, along with support for up to eight housekeeping alarms. Criti- cal, major, and minor alarms are reported via front panel LEDs. Alarm cut-off can be provisioned for audible alarms. Specifications Dimensions (HxWxD): Weight: Power Consumption: Alarm Outputs: 4.88" x .69" x 9.75" (12.4 x 1.75 x 24.8 cm) .56 lb. (.25 kg) 7.5 watts, maximum Critical, major, minor and up to eight housekeeping alarms 473 12/98 Revision © 1997, 1998 ADC Telecommunications, Inc. All Rights Reserved An Equal Opportunity Employer Specifications published here are current as of the date of publication of this document. Because we are continuously improving our products, ADC reserves the right to change specifications without prior notice. At any time, you may verify product specifications by contacting our headquarters office in Minneapolis. ADC Telecommunications, Inc. views its patent portfolio as an important corporate asset and vigorously enforces its patents. Products or features contained herein may be covered by one or more U.S. or foreign patents. ADC Telecommunications, Inc. P.O. Box 1101 Minneapolis, Minnesota 55440-1101 FAX: (612) 946-3292 From North America, Call Toll Free: 1-800-366-3891, Ext. 3223 Outside of North America: 612-938-8080 Home Page Address: http://www.adc.com International Sales Offices: Brussels, Belgium 32-2-712-6500 • United Kingdom 44-1189 879200 • Dusseldorf, Germany 49-211-530-655-0 Madrid, Spain 34-1-361-01-68 • Sydney, Australia 61-2-9975-1499 • Singapore 65-225-8228 • Beijing, China 86- 10-6500-7001 • Seoul, Korea 82-2-333-8989 • Bangalore, India 91-80-671-0230 • Malaysia 603-254-0025 Bangkok, Thailand 66-2-9595199 • Philippines 632-892-4476 • Sao Paulo, Brazil 55-11-3040-0666 • Buenos Aires, Argentina 541-788-8700 • Mexico City, Mexico 525-658-4519 • Venezuela 58-2-286-1444 • Miami Lakes, FL (Caribbean/Miami) 305-231-8742 • Montreal, Quebec (514) 677-9166 Vancouver, BC (604) 270-1675 Toronto, Ont. (905) 629-3104 • Ottawa, Ont. (613) 599-5729 . certified; completed OSMINE process 212/98 473 Soneplex ® Loop Extender System The Soneplex Loop Extender system is ideal for a variety of applications. Minimum release 5.01 SCU Element Management System Software 512/98 473 Soneplex ® Loop Extender System Soneplex Loop Extender Chassis 23 inch rack mount 19