The authors investigate friction and wear behaviours of atomic smooth graphite flake slides on hydrogenated diamond-like carbon (DLC). In this paper, the authors propose a novel method to examine if surfaces possess wear-resisting characteristic at micro-scale by measuring frictional force after a number of sliding cycles.
NGHIÊN CỨU KHOA HỌC WEAR-RESISTING BEHAVIOUR OF GRAPHITE DIAMOND-LIKE CARBON HETEROSTRUCTURE ĐẶC TÍNH CHỐNG MÀI MỊN CỦA CẤU TRÚC DỊ THỂ GRAPHITE - DIAMOND-LIKE CARBON Cao Cuong Vu1, Duc Thang Le2 Email: cuongxavi@gmail.com Postgraduated Office, Le Quy Don Technical University Sao Do University Date received: 27/10/2017 Date of post-review correction: 24/3/2018 Release date: 28/3/2018 Abstract The authors investigate friction and wear behaviours of atomic smooth graphite flake slides on hydrogenated diamond-like carbon (DLC) In this paper, the authors propose a novel method to examine if surfaces possess wear-resisting characteristic at micro-scale by measuring frictional force after a number of sliding cycles The current study is realized using an objective lens coupling into atomic force microscope (AFM) head and a visible tip Notably, frictional force between self-retracting motion (SRM) graphite flake and hydrogenated DLC surface almost remains unchanged after a number of sliding cycles in different conditions of temperature This result suggests a potential of wear-resisting in the case of atomic smooth graphite mesa slides on DLC surface This exciting finding is promising for the potential of utilization of using atomic smooth graphitic-based material as a wear-reducing material in practical applications Keywords: Graphite; diamond-like carbon; heterostructure; wear-resisting Tóm tắt Nhóm tác giả nghiên cứu vi ma sát mòn mảnh graphite mịn trượt bề mặt carbon có cấu trúc giống kim cương (DLC) Trong báo này, nhóm tác giả giới thiệu phương pháp để kiểm tra bề mặt có đặc tính chống mài mòn cấp độ micromet hay khơng, cách đo lực ma sát sau nhiều lần trượt tương đối bề mặt Nghiên cứu thực cách sử dụng thấu kính hiển vi lắp thêm vào thiết bị kính hiển vi đo lực nguyên tử đầu dò nanomet Điểm đáng ý lực ma sát mảnh graphite cực nhẵn có khả tự chuyển động vị trí ban đầu bề mặt DLC trì khơng đổi sau nhiều lần trượt hai bề mặt điều kiện nhiệt độ khác Kết là gợi ý về khả chớng mài mòn gaphite mịn trượt bề mặt DLC Kết cũng gợi triển vọng ứng dụng thực tế việc sử dụng graphite mịn vật liệu chống mài mòn Từ khóa: Graphite; carbon có cấu trúc giống kim cương; cấu trúc dị thể; chống mài mòn INTRODUCTION Investigation concerning friction- and wearreducing material is a mandatory task for tremendous scientists due to energy resources on the earth are being depleted by human exploitation at breakneck speed One of the reasons leading to the terrible demand of people for energy is the energy consumption caused by friction and wear of moving parts [1] Besides, unexpected energy dissipation consequently reduces durability and reliability of devices However, application of superlubric phenomenon, undoubtedly, can overcome this issues due to its extreme low of friction and virtual zero wear In the last two decades, some researches have been reported with respect to superlubric materials such as MoS2 [2], graphite (graphene), [3, 5] CNT [6], or respect to wear resistance [7, 8] In practical application field, especially at micro - and meso -scale, an inevitable trend is using wear-reduced heterostructures as solid lubricants The former also has been concerned recently [9, 12] Otherwise, from the prospective of hard disk drive (HDD) technology, the flying height should be as small as possible for enhancing the recording density As the flying height gradually reduces, the contact between slider and disk occurs, namely contact recording [13] However, contact recording technique has many disadvantages so far because of its unexpected friction and 34 Tạp chí Nghiên cứu khoa học - Đại học Sao Đỏ, ISSN 1859-4190 Số 1(60).2018 LIÊN NGÀNH CƠ KHÍ - ĐỘNG LỰC wear [14] Recently, scientists have focused on friction and wear behaviours of graphene/DLC heterostructure owing to its advantages of ability to improve technique in HDD technology [7, 11, 12] Although some works have been published, there are still limitations because of wear reducing but not surface - surface contact, which is the typical feature of moving parts at micro- and meso-scale Conventionally, AFM instrument has been widely used to measure friction of surfaces at nano-scale Scientists have attempted using modified AFM tip to improve size range of samples in their works [15, 16] However, using AFM device to measure friction at micro-scale still remains challenge [17] Thus, using AFM instrument for measuring friction between surfaces at micro-scale is a novel contribution to investigation methods of tribology field Here, for the first time, the authors have investigated friction behaviour of SRM graphite flake slides on hydrogenated DLC surface The current study reveals that frictional force of atomic smooth graphite on hydrogenated DLC is extremely low Particularly, the frictional force virtually remains unchanged after a specific number of sliding cycles even at room temperature These results maybe propose a potential of utilization of graphite DLC heterostructure for practical application in micro electro-mechanical systems (MEMS) as well as HDD technology fields in future measure friction between the SRM graphite flake and the DLC surface, an objective lens ( , Mitutoyo, Japan) coupling into the head of AFM instrument (NT-MDT, Russia) and a visible tip (VIT-P) were utilized In our experiments, the AFM tip was acted on the central area of the SiO2 cap The normal force, N, applied to the cap by the tip can be precisely measured (in the accuracy on the order of 3.98%) and is controlled through the AFM feedback system The lateral (shear) force, F, was applied to the cap by the same tip through the friction between the tip and the cap and can be also precisely measured (in the accuracy on the order of 0.7%) by the AFM 2.2 Experimental model The schematic diagram of experiment is illustrated in Fig The deflection and torsion of the cantilever are simultaneously obtained upon on a quadrant photodiode of AFM device then are converted to force unit through the well-known calibration method for AFM cantilever [25, 27] PRINCIPLE THEORY 2.1 Methodology Our experiment was carried out with three main steps including fabrication of samples, transfer SRM graphite flake on to DLC surface, and measurement friction between SRM graphite flake and DLC surface Graphite flakes were fabricated from high-quality, highly oriented pyrolytic graphite (HOPG) substrates by means of reactive ion etching, using silicon dioxide layer as self-aligned shadow masks The fabrication method can be found elsewhere [18, 22] Graphite mesas with a size of ì àm square, µm height with 200 nm thickness of silicon dioxide cover were obtained Owning to SRM mesas represent the contact of atomic smooth surfaces the authors then verified if graphite flake possesses SRM behaviour using optical microscope (OM, HiRox KH-3000) and micro-manipulator MM-3A (Kleindiek MM3A) The authors used 3D micro-manipulator and home-built tungsten tip (chemical etching) to transfer SRM graphite flake on hydrogenated DLC surface The latter was fabricated by plasma enhanced chemical vapor deposition technique, which is similar to that of the method has been presented in previous researches [13, 23, 24] To Fig (colour online) The schematic diagram of the experimental model adopted in this study An objective lens ( , Mitutoyu, Japan) is coupled onto AFM head combining with a special AFM cantilever with an extruded tip mounted in front in order to clearly observe the movement of SRM graphite flake The latter with 200 nm thickness of SiO2 cap is transferred on the DLC surface then both are placed on heat stage XYZ piezoelectric scanner tube is utilized to control the movement of sample Solid line schematic illustrates the track of graphite flake in forward direction and dashed line depicts the track in backward direction Sliding distance (x) is 1.2 µm, sliding velocity v is 1.2 µm per second N and F are the applied normal and lateral forces are in situ calibrated through the well-known calibration method for AFM cantilever based on obtained bending and torsion of cantilever upon a quadrant photodiode Applied normal force N adopted in the study: 7.267 to 17.702 µN for wear-verifying experiments Resolutions of normal and lateral force are 1.3 and 0.51 nN, respectively Tạp chí Nghiên cứu khoa học - Đại học Sao Đỏ, ISSN 1859-4190 Số 1(60).2018 35 NGHIÊN CỨU KHOA HỌC Frictional force in SRM graphite flake and DLC surface is defined since applied normal force reaches a certain magnitude that can drive SRM graphite flake to slides on DLC surface At present, AFM tip and SRM graphite flake with SiO2 cap simultaneously slide on DLC surface As it can be seen in Fig 1, solid line indicates the trace of AFM tip and SRM flake in forward direction and dashed line shows the trace in reverse direction The friction between the SRM graphite flake and the DLC surface is recorded after each certain sliding cycles until reaching a specific number of sliding cycles while the flake sliding on the DLC surface all the time temperature Additionally, thermal activation also effects on variation of friction through the decrease of energy barrier as well [31, 32] 2.3 Results and discussions Fig 2a shows representative lateral and normal forces (inset) in both forward and backward directions of sliding process at room temperature In general, friction is measured by placing the tip under an applied force and driving the sample beneath it [28] This motion leads to an effective twist of the cantilever as torsion and is induced in opposite directions for the different sliding directions For a single sliding line, the resulting friction data generate in the form of a friction loop The vertical parts of the loop correspond to the regions of static frictional force before the movement of graphite flake occurs, while the horizontal parts correspond to the kinetic friction during sliding process In practice, friction forces are most often reported as average of kinetic friction In return, average kinetic friction is calculated as a half of difference between the mean lateral forces during forward and backward motions Generally, friction loops in Fig must be drifted in the zero point, but in our experiments, friction loop shift in the point larger than zero point This effect may be due to crosstalk effect caused by applied normal force, however [25] Obtained lateral force loop is similar to the dynamical friction loop of AFM device’s principle that has been reported elsewhere [29, 30] The Inset in Fig 2(a) generates variation trend of applied normal force at entire sliding process of forward and backward directions Obviously, the normal load in forward direction is almost the same in comparison with its magnitude in reverse direction, namely the normal load is invariant in the entire sliding process Fig 2(b) shows typical lateral force loops at different conditions of temperature corresponding to room temperature ( ~ 27°C), 50, 100 and 120°C (black, red, blue, and violet curves, respectively) Obviously, obtained curves in Fig 2(b) indicate both static and kinetic friction decreases since temperature increases In other words, when temperature increases, dynamic friction decreases due to reducing of water-related substance at high (a) (b) Fig (colour online) Representative lateral force (F) and applied normal force (N) loops at different temperature (t) conditions (a) Lateral force and applied normal force loops at temperature condition of 50OC, blue curves exhibit lateral force and applied force (inset) in forward direction, red curves represent lateral force and applied force in reverse direction (b) Summary lateral force loops at different conditions of temperature corresponding to room temperature (~ 27OC, black), 50 (red), 100 (blue), and 120OC (violent), respectively Sliding distances (x) are 1.2 µm for all experiments The authors next characterized the variation trend of frictional force when SRM graphite flake slides on DLC surface from initial movement to after a specific number of cycles at different conditions of temperature Variation of frictional force in Fig shows a surprising trend, that is, frictional force is almost unchanged after a number of sliding cycles even at room temperature (blue) and this trend become obviously at higher temperature conditions (olive, orange, and pink colour curves in Fig 3) The blue, olive, orange, and pink dashed line in Fig indicate average magnitudes - 3012, 2136, 1470, and 1164 nN (corresponding to 0.195, 36 Tạp chí Nghiên cứu khoa học - Đại học Sao Đỏ, ISSN 1859-4190 Số 1(60).2018 LIÊN NGÀNH CƠ KHÍ - ĐỘNG LỰC 0.1335, 0.093, and 0.07 MPa per unit area) - of frictional forces at room temperature, 50, 100, and 120°C, respectively Obviously, these data of frictional forces are well approximated compared with the average magnitudes with an acceptable statistical offset Despite of these obtained results are slightly higher in compared with the result of super-lubricity phenomenon reported by Liu et al [4], but significant lower in compared with the shear-strength magnitude have been presented with respect to superlubricity phenomenon in previous research [3, 33] AFM topography image area and Raman spectra of several selected points in the sliding area after SRM graphite mesa is controlled to move away The authors speculate that the roughness is significantly increased if DLC surface damaged after a number of cycles - the occurrence of wear at DLC surface Similarly, the 2D peak corresponding to the featured peak of graphene layer(s) will be observed if wear-related traces occurs in SRM graphite flake The invariant friction after a number of sliding cycles suggests a prediction that no-wear state hold when SRM graphite flake is taken into contact with DLC surface In case of the wear exists, the occurrence of wear causes the increase of surface’s roughness In its return, the latter subsequently leads to a gradual rise in the frictional force [34, 35] In contrast, when the wear does not occur, frictional force is, of course, almost unchanged when the applied force remains constant In our experiments, the applied force was controlled as an invariant value by the AFM feedback system itself Taken together, our obtained results thus propose one conclusion that there is almost zero wear in case of graphite flake slides on DLC surface under experience a certain applied normal force in a range not lead to plastic deformation of surfaces 4500 Room Temp 4000 50 o 100o 120o 3500 Ffr (nN) 3012 3000 2500 2136 2000 1470 1500 (a) 4500 4500 4500 4200 4200 4200 3900 3900 3900 3600 3600 3600 3300 3300 3300 3000 3000 3000 2700 2700 2700 2400 2400 2400 2100 2100 2100 1800 1800 1800 1500 1500 1500 (b) Fig (colour online) Variation trend of frictional force (Ffr) when graphite flake slides on DLC surface at different conditions of temperature (t) after a certain number of sliding cycles (n) Each data point corresponds to average in a dozen subsequent sliding lines, error bar demonstrates the standard deviation Dashed lines indicate average magnitudes in each temperature condition Fig AFM topography and Raman spectra 1200 1200 1200 images indicate topography and featured peaks of surface in the sliding area when GF slides on DLC surface after a certain number of cycles (a) AFM topography image indicates nearly atomicscale smoothness of DLC after a number of sliding cycles both within (dashed yellow lines area) and without the sliding area with the RMS deviation of profiles (Rq) are less than 0.2 nm (bottom curves) Scale bar is µm; (b) Raman spectra of two selected random points in the sliding area (blue square area in Fig 4a) exhibit D and G peaks at of ~1340 and 1577 cm-1 of Raman shift (RS) positions (vertical axis indicates Raman Intensity, RI) To certify above conclusion, the authors further confirm if there are wear-related traces at DLC surface and SRM graphite flake by conducting As it is depicted in Fig 4(a), the DLC surface under experienced sliding beneath the SRM graphite flake after a number of sliding cycles indicates 1000 1164 500 1000 1500 n (cycles) 2000 Tạp chí Nghiên cứu khoa học - Đại học Sao Đỏ, ISSN 1859-4190 Số 1(60).2018 37 NGHIÊN CỨU KHOA HỌC nearly atomic-scale smoothness surface with the root-mean-square deviation of profiles (Rq) are less than 0,2 nm both within (dashed yellow lines area) and without the sliding area This value is the same order as the roughness of the intrinsic DLC surface reported in previous research [36] This result proves that DLC surface is preserved without wear when it is controlled to slide beneath the SRM graphite flake after a number of sliding cycles Raman spectroscopy shows many differing features in the Raman shift region of 800 – 3000 cm-1, which can be utilized to distinguish the nature of the bonding between carbon atoms In particular, the so-called D, G, and 2D peaks, which correspond to the Raman shift (RS) of around 1360, 1560, and 2700 cm-1 have been widely used to confirm if a surface is DLC or graphene/graphite [37] Our obtained Raman spectra of two selected random points in sliding area are plotted in Fig 4(b), in which mere D and G peaks presenting hydrogenated DLC material [11] are observed It simply means that the sliding area is purely hydrogenated DLC This evidence obviously indicates that there is no any debris of graphene/graphite in the DLC surface after sliding, thus there is virtually zero wear at both graphite and DLC surfaces when the SRM graphite flake is taken into contact with DLC surface CONCLUSIONS Our results with a virtual unchanged of friction after a number of sliding cycles have provided a reliable foundation to certify wear-resisting behaviour of atomic smooth graphite/hydrogenated DLC heterostructure Although there are some worth attention results revealed by these studies, there are also limitations that can improve in further work (i) Contaminations may be absorbed into the gap between graphite flake and DLC surface caused by the transfer and experiment processes are realized at ambient air This issue will lead to extra frictional force compared with the result of intrinsic SRM graphite mesa on DLC surface (ii) Self-clean effect maybe not clearly observed in this instance due to sliding distance is quite small compared with the size of graphite mesa (iii) Square mesa might not absolutely move along its edges while sliding on DLC surface This unexpected factor will lead to extra frictional force by the reason of unexpected edge effect To conclude, the authors have investigated variation of friction when SRM graphite flake slides on DLC surface after a specific number of cycles at different conditions of temperature using an objective lens coupling into AFM head of AFM device and a visible tip Our study reveals that frictional force remains almost unchanged after a number of sliding cycles in all cases of different temperature conditions The current study serves as a proof-of-concept that atomic smooth graphite flake slides on DLC coating surface could be used as friction-reduced and wear-resisting of moving parts on device as well as a possibility of utilization of atomic smooth graphitic material in MEMS applications This study may offer a new strategy to treat shortcomings in contact recording technology of HDD technique in future as well REFERENCES [1] Wang, H., Liu, F., Fu, W., Fang, Z., Zhou, W., and Liu, Z (2014) Two-dimensional heterostructures: fabrication, characterization, and application Nanoscale 6(21), pp 12250 [2] Martin, J., Donnet, C., Le Mogne, T., and Epicier, T (1993) Superlubricity of molybdenum disulphide Phys Rev B 48(14), p 10583 [3] Dienwiebel, M., Verhoeven, G S., Pradeep, N., Frenken, J W M., Heimberg, J A., and Zandbergen, H W (2004) Superlubricity of Graphite Phys Rev Lett 92(12), p 126101 [4] Liu, Z., Yang, J., Grey, F., Liu, J Z., Liu, Y., Wang, Y., Yang, Y., Cheng, Y., and Zheng, Q.-S (2012) Observation of Microscale Superlubricity in Graphite Phys Rev Lett 108(20), p 205503 [5] Feng, X., Kwon, S., Park, J Y., and Salmeron, M (2013) Superlubric sliding of graphene nanoflakes on graphene ACS nano 7(2), pp 1718 [6] Zhang, R., Ning, Z., Zhang, Y., Zheng, Q., Chen, Q., Xie, H., Zhang, Q., Qian, W., and Wei, F (2013) Superlubricity in centimetres-long double-walled carbon nanotubes under ambient conditions Nat Nanotechnol 8, pp 912 [7] Berman, D., Deshmukh, S A., Sankaranarayanan, S K., Erdemir, A., and Sumant, A V (2014) Extraordinary Macroscale Wear Resistance of One Atom Thick Graphene Layer Adv Funct Mater 24(42), pp 6640 [8] Klemenz, A., Pastewka, L., Balakrishna, S G., Caron, A., Bennewitz, R., and Moseler, M (2014) Atomic Scale Mechanisms of Friction Reduction and Wear Protection by Graphene Nano Lett 14(12), pp 7145 [9] Leven, I Krepel, D., Shemesh, O., and Hod, O (2012) Robust superlubricity in graphene/h-BN heterojunctions J Phys Chem Lett 4(1), pp 115 [10 ].Wang, L.-F., Ma, T.-B., Hu, Y.-Z., Zheng, Q., Wang, H., and Luo, J (2014) Superlubricity of twodimensional fluorographene/MoS2 heterostructure: 38 Tạp chí Nghiên cứu khoa học - Đại học Sao Đỏ, ISSN 1859-4190 Số 1(60).2018 LIÊN NGÀNH CƠ KHÍ - ĐỘNG LỰC a first-principles study Nanotechnology 25(38), p 385701 [11] Zhao, F., Afandi, A., and Jackman, R B (2015) Graphene diamond-like carbon films heterostructure Appl Phys Lett 106(10), p 102108 [12] Berman, D., Deshmukh, S A., Sankaranarayanan, S K., Erdemir, A., and Sumant, A V (2015) Macroscale superlubricity enabled by graphene nanoscroll formation Science), p 1262024 [13] Talke, F E (1997) A review of contact recording technologies Wear 207(1), pp 118 [14] Hua, W., Liu, B., Yu, S., and Zhou, W (2010) Contact recording review Microsyst Technol 16(4), pp 493 [15] Dietzel, D., Ritter, C., Mönninghoff, T., Fuchs, H., Schirmeisen, A., and Schwarz, U D (2008) Frictional Duality Observed during Nanoparticle Sliding Phys Rev Lett 101(12), p 125505 [16] Dietzel, D., Feldmann, M., Schwarz, U D., Fuchs, H., and Schirmeisen, A (2013) Scaling Laws of Structural Lubricity Phys Rev Lett 111(23), p 235502 [17].Dietzel, D., Schwarz, U D., and Schirmeisen, A (2014) Nanotribological studies using nanoparticle manipulation: Principles and application to structural lubricity Friction 2(2), pp 114 [18].Lu, X., Yu, M., Huang, H., and Ruoff, R S (1999) Tailoring graphite with the goal of achieving single sheets Nanotechnology 10(3), p 269 [19].Lu, X., Huang, H., Nemchuk, N., and Ruoff, R S (1999) Patterning of highly oriented pyrolytic graphite by oxygen plasma etching Appl Phys Lett 75(2), pp 193 [20].Zheng, Q.-S., Jiang, B., Liu, S., Weng, Y., Lu, L., Xue, Q., Zhu, J., Jiang, Q., Wang, S., and Peng, L (2008) Self-Retracting Motion of Graphite Microflakes Phys Rev Lett 100(6), p 067205 [21] Cuong Cao, V., Shoumo, Z., Urbakh, M., Qunyang, L., He, Q C., and Quanshui, Z (2016) Observation of normal-force-independent superlubricity in mesoscopic graphite contacts Phys Rev B 94(8), pp 081405 (6 pp.) [22] Shou-Mo Zhang, C.-C V., Qun-Yang Li, Norio Tagawa and Quan-Shui Zheng (2016) Superlubricity Relevant in Hard Disk Drive Applications ASME 2016 Conference on Information Storage and Processing Systems), pp ISPS2016 [23] Wang, W., Dai, S., Li, X., Yang, J., Srolovitz, D J., and Zheng, Q.-S (2015) Measurement of the cleavage energy of graphite Nat Commun [24] Ferrari, A C (2004) Diamond-like carbon for magnetic storage disks Surf Coat Tech 180, pp 190 [25] Li, Q., Kim, K.-S., and Rydberg, A (2006) Lateral force calibration of an atomic force microscope with a diamagnetic levitation spring system Rev Sci Instrum 77(6), pp 06510 [26].Sader, J E., Larson, I., Mulvaney, P., and White, L R (1995) Method for the calibration of atomic force microscope cantilevers Rev Sci Instrum 66(7), pp 3789 [27] Sader, J E., Chon, J W., and Mulvaney, P (1999) Calibration of rectangular atomic force microscope cantilevers Rev Sci Instrum 70(10), pp 3967 [28] Perry, S S (2004) Scanning probe microscopy measurements of friction MRS Bull 29(07), pp 478 [29] Meyer, G., and Amer, N M (1990) Simultaneous measurement of lateral and normal forces with an optical-beam-deflection atomic force microscope Appl Phys Lett 57(20), pp 2089 [30] Morel, N., Ramonda, M., and Tordjeman, P (2005) Cantilever calibration for nanofriction experiments with atomic force microscope Appl Phys Lett 86(16), pp 163103 [31] Tshiprut, Z., Zelner, S., and Urbakh, M (2009) Temperature-induced enhancement of nanoscale friction Phys Rev Lett 102(13), p.136102 [32] Barel, I., Urbakh, M., Jansen, L., and Schirmeisen, A (2010) Temperature dependence of friction at the nanoscale: when the unexpected turns normal Tribol Lett 39(3), pp 311 [33] Martin, J.-M., Donnet, C., Le Mogne, T and Epicier, T (1993) Superlubricity of molybdenum disulphide Phys Rev B 48(14), p 10583 [34] Dong, Y., Wu, X., and Martini, A (2013) Atomic roughness enhanced friction on hydrogenated graphene Nanotechnology 24(37), p 375701 [35] Ye, Z., Otero-de-la-Roza, A., Johnson, E R., and Martini, A (2014) The role of roughness-induced damping in the oscillatory motion of bilayer graphene Nanotechnology 25(42), p 425703 [36] Peng, X., Barber, Z., and Clyne, T (2001) Surface roughness of diamond-like carbon films prepared using various techniques Surf Coat Tech 138(1), pp 23 [37] Casiraghi, C., Piazza, F., Ferrari, A., Grambole, D., and Robertson, J (2005) Bonding in hydrogenated diamond-like carbon by Raman spectroscopy Diamond Relat Mater 14(3), pp 1098 Tạp chí Nghiên cứu khoa học - Đại học Sao Đỏ, ISSN 1859-4190 Số 1(60).2018 39 ... virtual unchanged of friction after a number of sliding cycles have provided a reliable foundation to certify wear-resisting behaviour of atomic smooth graphite/ hydrogenated DLC heterostructure. .. variation trend of frictional force when SRM graphite flake slides on DLC surface from initial movement to after a specific number of cycles at different conditions of temperature Variation of frictional... cases of different temperature conditions The current study serves as a proof -of- concept that atomic smooth graphite flake slides on DLC coating surface could be used as friction-reduced and wear-resisting