6FM200-X 12V 200Ah(10hr) Shenzhen Center Power Tech.Co.Ltd, Overview The rechargeable batteries are lead-lead dioxide systems The dilute sulfuric acid electrolyte is absorbed by separators and plates and thus immobilized Should the battery be accidentally overcharged producing hydrogen and oxygen, special oneway valves allow the gases to escape thus avoiding excessive pressure build-up Otherwise, the battery is completely sealed and is, therefore, maintenance-free, leak proof and usable in any position Battery Construction Component Positive plate Negative plate Raw material Lead dioxide Lead Container Cover ABS General Features Terminal Separator Electrolyte Rubber Copper Fiberglass Sulfuric acid Battery Specification Positive and negative plates in lead-calcium-tin alloy; Stable Quality&High Reliability; Sealed Construcrion; Long Service Life; Maintenance-Free Operation; Low Pressure Venting System; Low Self Discharge; U.L.Component Recognition; Six months shelf life at 20℃; Design life 10 years Dimensions and Weight Length(mm / inch) Width(mm / inch) Height(mm / inch) Total Height(mm / inch) Approx Weight(Kg / lbs) Safety valve ABS 522 / 20.6 238 / 9.37 218 / 8.58 223 / 8.78 65.0 / 143 Performance Characteristics 12V Nominal Voltage Number of cell 10 years Design Life Nominal Capacity 77℉(25℃) 10 hour rate (20.0A, 10.8V) 200Ah hour rate (36.0A, 10.5V) 180Ah hour rate (128A, 9.6V) 128Ah Internal Resistance ≤4.0 mOhms Fully Charged battery 77℉(25℃) Self-Discharge 3% of capacity declined per month at 20℃(average) Operating Temperature Range Discharge -20~60℃ Charge -10~60℃ Storage -20~60℃ 1000A(5s) Max Discharge Current 77℉(25℃) 3300A Short Circuit Current Charge Methods: Constant Voltage Charge 77℉(25℃) 2.40-2.45VPC Cycle use Maximum charging current 60.0A Temperature compensation -30mV/℃ 2.20-2.30VPC Standby use Temperature compensation -20mV/℃ * Weight deviation: ± 5% Discharge Constant Current (Amperes at 77oF25oC) End Point Volts/Cell 1.60V 10min 15min 30min 45min 1h 3h 5h 10h 360 220 159 128 57.6 38.2 20.4 1.65V 350 212 153 124 55.6 37.2 20.3 1.70V 337 206 149 120 55.0 36.6 20.2 1.75V 319 200 145 117 53.4 36.0 20.1 1.80V 269 187 140 114 51.0 35.4 20.0 o o Discharge Constant Power (Watts at 77 F25 C) End Point Volts/Cell 1.60V 10min 15min 30min 45min 1h 3h 5h 10h 625 402 294 230 109 73.0 40.2 1.65V 604 390 286 225 107 72.0 39.2 1.70V 586 382 279 221 105 71.2 38.4 1.75V 578 372 274 217 101 70.2 37.6 1.80V 554 364 270 215 98.0 69.3 36.7 (Note)The above characteristics data are average values obtained within three charge/discharge cycles not the mimimum values.All data shall be changed without notice,Vision reserves the right to explain and update the information contained hereinto Shenzhen Center Power Tech.Co.Ltd, STOCK CODE: 002733 www.vision-batt.com 6FM200-X 12V 200Ah(10hr) Shenzhen Center Power Tech.Co.Ltd, Constant Power Discharge Constant Current Discharge 1000 Wattage(W) 100 10 100 10 1 10 1.60V 1.75V 1000 100 1.65V 1.80V 1.70V 10 10000 1.60V 1.75V Current Charged Volume Time/mins 1000 100 1.65V 1.80V Voltage Current(A) 1000 10000 1.70V Time/mins Constant voltage charging characteristic (0.25CA,25 ℃) (%) (XCA) (V) 140 12.0 120 0.25 100 0.20 20.0 A 55.0 A 36.0 A 9.6 410 A 80 180 A 128 A 0.15 0.10 5.2 2.6 15.0 10.0 7.5 5.0 2.5 9.6 7.2 4.8 2.4 14.4 13.8 9.2 6.9 4.6 2.3 13.2 8.8 6.6 4.4 2.2 -10 120 0 Cycl e Us e 12.0 11.0 Charging Current 10 12 14 Charging time (hours) 16 18 20 100 Capacity(%) (V/CELL) (V/6V) (V/4V) (V/8V) (V/12V) 7.8 0.05 Charge Voltage Self-discharge characteristic Relationship between charging voltage and temperature 15.6 10.4 20 Charged Volume 14.0 13.0 60 40 15.0 STANDB 90 80 70 60 Y USE ℃ ℃ ℃ 50 20 40 10 50 30 Ambient temperature (℃) 40 60 Life characteristics of Standby use 10 12 14 Storage time: months 16 18 20 Cycle service life in relation to depth of discharge 120 100 Capacity(%) Capacity(%) 100 80 60 Testing conditions:floating voltage:2.27 to 2.30V Cell ambient temperature: 25°C(77°F) 80 60 100% D.O.D 50% D.O.D 40 20 20 0 30% Depth of discharge 40 Life(year) 200 400 600 800 1000 Number of cycles(cycles) 1200 1400 Temperature effects on capacity Temperature effects on float life 120 Life(years) Capacity (%) 100 C 0.05 0.1C C 0.2 80 60 40 1.0C 2.0C 20 o Temperature( C) Shenzhen Center Power Tech.Co.Ltd, -20 -10 10 20 Temperature (°C ) STOCK CODE: 002733 30 40 50 www.vision-batt.com

Ngày đăng: 23/04/2019, 21:23

TỪ KHÓA LIÊN QUAN