guidelines for the installation

192 88 0
guidelines for the installation

Đang tải... (xem toàn văn)

Tài liệu hạn chế xem trước, để xem đầy đủ mời bạn chọn Tải xuống

Thông tin tài liệu

Modification index 01 Modification index 01 In the electronic pocket-book all necessary changes and supplements will be registered at short notice A list showing the request of modification, date and modification index see below Modification- Date Modification index 00 01.10.2004 none 01 24.02.2005 Chapter 17, Checklist for inspection of starter motor syst Modification index 01 DEUTZ AG, Installation Manual BFM 1015 Modification index 01 Modification index 01 Modification index 01 Modification index 01 17 Checklist for inspection of starter motor system 17- Modification index 01 DEUTZ AG, Installation Manual BFM 1015 Modification index 00 Modification index 00 Modification index 00 Modification index 01 Modification index 01 Modification index 00 Modification index 01 Modification index 00 Modification index 00 Modification index 00 Modification index 00 Modification index 00 Modification index 00 17 Checklist for inspection of starter motor system Cable laying, cable dimensioning, cable connection: • Main cable (to terminal 30) and control cable (to terminal 50) have to be routed in that way that they not come into contact (prevent short circuit) • The cables have to be fixed approx 300mm after starter motor connection for the first time • At terminal 50 only the control line to starter motor coming from a relay or from starter switch is allowed Additional electrical consumer e.g relays have to be connected at terminal 45 • The permitted resistance of control cable (terminal 50) and battery main cable (terminal 30) can be rough calculated with cross section, cable length (incl ground cable, if available) number of transitions (add per transition 0,05mOhm) For the starter motor the permitted total resistance is cable resistance plus battery internal resistance Admissible values see starter drawing or installation guide line Power relay for activating starter: This relay should be similar to Bosch relay 332 002 150, the following data should be checked: • Switch-on voltage lower than 8Volt • admissible electrical power 10% over value on starter motor drawing, e.g HE starter 60Amps, relay 66Amps • for short time (under sec.) 250Amps must be permitted • relay should be switched off when voltage is between 1,5 to 4,0V Start blocking relay: A minimum waiting time of (6) sec must be observed • after the drop of signal of terminal 50 • after drop of signals of "W", "D", "n" • after starter has been switched off by speed signal • start function must be blocked as long a speed signal occurs DEUTZ AG, Installation Manual BFM 1015 ...Modification index 01 In the electronic pocket-book all necessary changes and supplements will be registered at short notice A list showing the request of modification, date and... index 00 01.10.2004 none 01 24.02.2005 Chapter 17, Checklist for inspection of starter motor syst Modification index 01 DEUTZ AG, Installation Manual BFM 1015 Modification index 01 Modification... Modification index 01 Modification index 01 17 Checklist for inspection of starter motor system 17- Modification index 01 DEUTZ AG, Installation Manual BFM 1015 Modification index 00 Modification

Ngày đăng: 08/03/2019, 12:57

Mục lục

    1015 Installation Manual 1015/C/CP

    1.5 Seperate expansion tank with radiator- fan system

    1.10 Wiring diagrams of cooling circuits

    1.13 Filtration of cooling air

    2.4 Dimensioning the air cleaners

    2.6 Combustion air temperature rise

    2.9 Pressurizing of hydraulic oil tanks

    3.2 Permissible resistance in the exhaust system

    3.3 Measuring the exhaust back pressure

    3.4 Dimensioning the exhaust pipe and determining the piping resistance

Tài liệu cùng người dùng

Tài liệu liên quan