Tài liệu hạn chế xem trước, để xem đầy đủ mời bạn chọn Tải xuống
1
/ 102 trang
THÔNG TIN TÀI LIỆU
Thông tin cơ bản
Định dạng
Số trang
102
Dung lượng
3,95 MB
Nội dung
Installation of Digital Distribution Frame (DDF) all-in-One Alcatel Service (SM) for Mobile Operators Alcatel GSM 900/1800/1900 Site Engineering Methods INS-DDF Installation method of DDF for BSS equipment Alcatel File m43533a2.doc V2 Reference 3DF 00435 0033 RJZZA Edition 02 Status Released Date 00/12/26 All rights reserved Passing on and copying of this document, use and communication of its contents not permitted without written authorization from Alcatel Page 1/102 Installation of Digital Distribution Frame (DDF) Contents Contents PREFACE .3 PREREQUISITE TASK TO START WORK ON SITE SAFETY RULES AND PRECAUTIONS .7 INSTALLATION RULES KIT DESCRIPTION 11 FRAME INSTALLATION 19 INSTALLATION OF U RAIL ON FRAME 30 INSTALLATION OF U RAIL ON WALL 32 INSTALLATION OF U RAIL IN 19” RACK 39 CONNECTION MODULE INSTALLATION AND WIRING 44 10 CABLE MAPPING 69 APPENDIX A TOOLS AND ACCESSORIES 97 APPENDIX B CCL, COMPLETION CHECK LIST 98 APPENDIX C DDF ACCEPTANCE REPORT 101 ABBREVIATIONS 102 Alcatel File m43533a2.doc V2 Reference 3DF 00435 0033 RJZZA Edition 02 Status Released Date 00/12/26 All rights reserved Passing on and copying of this document, use and communication of its contents not permitted without written authorization from Alcatel Page 2/102 Installation of Digital Distribution Frame (DDF) Preface Preface This document describes the procedure for installing a DDF for BSS equipment: Purpose BSC, TC, A925 TC, A935 MFS, A935 i-MFS and BTS all-in-One Alcatel Service (SM) for Mobile Operators This document is used in service Cable premier History Date Edition 00/12/26 02 Comments Evolution Introduction cable mapping of A925 TC and A935 i-MFS 990825 01 Creation: Remarks from R.Becker, J.P.Pasquet, M.Monthus Audience • Assumed knowledge Alcatel Staff (Intermediate and low level) You must have a basic understanding of the following • BSS Alcatel operations • Experience of electrical mounting, cabling Related documents Sigle Alcatel File m43533a2.doc V2 Title of document Alcatel number Product data sheet for wall fixation 1AD 02844 0001 Product data sheet for mechanical part 1AD 02843 0001 Product data sheet for terminal block 1AB 06634 0011 Product data sheet for rack fixation 1AD 02845 0001 Product data sheet for DDF 1AD 02846 0001 Product data sheet for labels 1AD 02854 0001 Reference 3DF 00435 0033 RJZZA Edition 02 Status Released Date 00/12/26 All rights reserved Passing on and copying of this document, use and communication of its contents not permitted without written authorization from Alcatel Page 3/102 Installation of Digital Distribution Frame (DDF) Preface Document structure This section provides a summary of the contents of each chapter Chapter : Prerequisite task to start work on site: This chapter describes what is to be checked at base before leaving for the site Chapter : Safety rules and precautions: This chapter describes the safety rules to be followed for the protection of on site personal, as well of the equipment Chapter : Installation rules: This chapter describes the rules to be followed for cabling the DDF Chapter : Kit description: This chapter describes the DDF parts and kits Chapter : Frame installation: This chapter describes frame installation on different situations, the ground connection on each case, the cable and jumper passing in the cable way and the cable way cover assembling and dismantling Chapter : Installation of U rail on frame Chapter : Installation of U rail on wall: assembly, mounting and grounding Chapter : Installation of U rail in 19” rack: This chapter describes the installation in two diferent situations: with connection modules far from the rack and close to the rack (at rack level) Chapter : Connection module installation and wiring This chapter describes the installation of connection modules and accessories on U rail, cable preparation L904, L907, Flex3, wire way and ground connection to module and jumper connection Chapter 10 : Cable mapping This chapter describes the :connection module numbering on frame cable and signal mapping for BSC G2, TC G2, A925 TC, A935 MFS, A935 i-MFS, BTS, form sheet for connection mapping Appendix A : Tools and accessories Appendix B : Completion Check List Appendix C : Site acceptance report Abbreviations : Alcatel File m43533a2.doc V2 Reference 3DF 00435 0033 RJZZA Edition 02 Status Released Date 00/12/26 All rights reserved Passing on and copying of this document, use and communication of its contents not permitted without written authorization from Alcatel Page 4/102 Installation of Digital Distribution Frame (DDF) Chapter 1: Prerequisite task to start work on site Prerequisite task to start work on site This chapter describes what is to be checked at base before leaving for the site: Alcatel File m43533a2.doc V2 • check safety instructions • ensure you have access to the site • check the documentation • check the tools • check the supplies Reference 3DF 00435 0033 RJZZA Edition 02 Status Released Date 00/12/26 All rights reserved Passing on and copying of this document, use and communication of its contents not permitted without written authorization from Alcatel Page 5/102 Installation of Digital Distribution Frame (DDF) Chapter 1: Prerequisite task to start work on site Check safety instructions • Before leaving for the site, check that safety precautions have been taken, in accordance with safety instructions Ensure you have access to the site • Check that the operator was informed about the intervention on site and provides access: operator personnel (name, address, telephone number), keys, site access information Check the documentation • Installation documents • Site documentation • Information’s from customer for cable mapping in the DDF • Protection equipment • Installation tools • Installation kits in accordance with the site documentation Check the tools Check the supplies Alcatel File m43533a2.doc V2 Reference 3DF 00435 0033 RJZZA Edition 02 Status Released Date 00/12/26 All rights reserved Passing on and copying of this document, use and communication of its contents not permitted without written authorization from Alcatel Page 6/102 Installation of Digital Distribution Frame (DDF) Chapter 2: Safety rules and precautions Safety rules and precautions This chapter describes the safety rules to be followed for the protection of on site personal, as well of the equipment: Alcatel File m43533a2.doc V2 • general safety • safety on site • safety of people • safety of equipment Reference 3DF 00435 0033 RJZZA Edition 02 Status Released Date 00/12/26 All rights reserved Passing on and copying of this document, use and communication of its contents not permitted without written authorization from Alcatel Page 7/102 Installation of Digital Distribution Frame (DDF) Chapter 2: Safety rules and precautions General safety • Follow all the rules are applicable on site in accordance with local legislation • The working area must be clean, clear of obstacles and marked out • If needed, a temporary barrier of plastic chain and warning sign should be set up Safety on site to prevent access of unauthorized personnel • Check that the earth connection is done and is effective (all ground cables have the connection screws tightened) • Safety of people Make all the electrical connections before powering up the equipment The installation team must wear protection gear: • work clothes • safety footwear • protective gloves (when needed) • The equipment must comply with current regulations Safety of equipment Alcatel File m43533a2.doc V2 Reference 3DF 00435 0033 RJZZA Edition 02 Status Released Date 00/12/26 All rights reserved Passing on and copying of this document, use and communication of its contents not permitted without written authorization from Alcatel Page 8/102 Installation of Digital Distribution Frame (DDF) Chapter 3: Installation rules Installation rules Installation rules This chapter describes the rules to be followed for cabling the DDF Alcatel File m43533a2.doc V2 Reference 3DF 00435 0033 RJZZA Edition 02 Status Released Date 00/12/26 All rights reserved Passing on and copying of this document, use and communication of its contents not permitted without written authorization from Alcatel Page 9/102 Installation of Digital Distribution Frame (DDF) Chapter 3: Installation rules PCM cables • PCM cables go into connection modules from the left of the module • PCM cables must be connected to earth at both ends Two cases are possible: - drain connection to earthing pin of connection module - cable braid connection with tie wrap with metallic braid Jumpers • Jumpers go into connection modules from the right of the module • The drain of jumpers must be connected at both ends • The cables to be used for jumpering: - for 120 ohm: L904 pair - for 75 ohm: Flex3 coax Alcatel File m43533a2.doc V2 Reference 3DF 00435 0033 RJZZA Edition 02 Status Released Date 00/12/26 All rights reserved Passing on and copying of this document, use and communication of its contents not permitted without written authorization from Alcatel Page 10/102 Installation of Digital Distribution Frame (DDF) Chapter 10: Cable mapping Wire mapping in connectors for A935-MFS subrack a, GPU - bb, 120 ohm, T(R)x (1 cable of 16 pairs) cable a/bb/0.T(R)x XN00 XP00 XN01 XP01 XN02 XP02 XN03 XP03 XN04 XP04 XN05 XP05 XN06 XP06 XN07 XP07 pair pair pair pair pair pair pair pair shield 10 10 10 10 cable a/bb/0.T(R)x XN08 XP08 XN09 XP09 XN10 XP10 XN11 XP11 XN12 XP12 XN13 XP13 XN14 XP14 XN15 XP15 pair pair 10 pair 11 pair 12 pair 13 pair 14 pair 15 pair 16 X = receive on Rx port X = transmit on Tx port subrack a, GPU - bb, 75 ohm, T(R)x (2 cable of pairs) cable a/bb/0.T(R)x shield Xr00 Xt00 coax Xr01 Xt01 coax Xr02 Xt02 coax Xr03 Xt03 coax Xr04 Xt04 coax Xr05 Xt05 coax Xr06 Xt06 coax Xr07 Xt07 coax 8 Xr08 Xt08 coax Xr09 Xt09 coax Xr10 Xt10 coax Xr11 Xt11 coax Xr12 Xt12 coax Xr13 Xt13 coax Xr14 Xt14 coax Xr15 Xt15 coax 8 cable a/bb/1.T(R)x shield X = receive on Rx port X = transmit on Tx port t = tip r = ring alarm input cable (external alarms) blue white orange white green white brown white shield grey white blue red orange red green red brown red MLOG EALM1 0VBAT EALM2 0VBAT EALM3 0VBAT EALM4 0VBAT EALM5 0VBAT EALM6 0VBAT EALM7 0VBAT EALM8 0VBAT 10 10 77 88 10 cross connection made on site pairs alarm output cable (dry loops) contacts closed in stand by - no alarm white orange green white white grey blue red red green brown red shield red contacts closed when active - alarm state brown white orange red white blue MLOG TELL1 TELR1 TELL2 TELR2 TELL3 TELR3 TELL4 TELR4 TELL5 TELR5 TELL6 TELR6 grey TELL1 TELT1 TELL2 TELT2 TELL3 TELT3 TELL4 TELT4 TELL5 TELT5 TELL6 TELT6 Alcatel pair wire blue wire white 3 4 5 orange green brown grey white File m43533a2.doc V2 white white white 6 10 11 12 13 blue orange green brown grey blue orange green red red black red Reference 3DF 00435 0033 RJZZA red Edition 02 red Status Released black black Date 00/12/26 All rights reserved Passing on and copying of this document, use and communication of its contents not permitted without written authorization from Alcatel Page 88/102 Installation of Digital Distribution Frame (DDF) Chapter 10: Cable mapping Cable and signal mapping for A935 i-MFS – Frame mapping Position Subrack_3 Tx and Rx i-GPU 01 to 05 alarmes i-GPU 28 i-GPU 29 i-GPU 30 i-GPU 31 i-GPU 32 i-GPU 33 i-GPU 34 i-GPU 35 i-GPU 36 i-GPU 37 i-GPU 38 i-GPU 18 i-GPU 19 i-GPU 20 i-GPU 21 i-GPU 22 i-GPU 23 i-GPU 24 i-GPU 25 i-GPU 26 i-GPU 27 SUBRACK_1 i-GPU 07 i-GPU 08 i-GPU 09 i-GPU 10 i-GPU 11 i-GPU 12 i-GPU 13 i-GPU 14 i-GPU 15 i-GPU 16 SUBRACK_2 O&M CP1500 i-GPU 02 i-GPU 03 O&M CP1500 i-GPU 04 i-GPU 05 DC/DC DC/DC Tx and Rx i-GPU spare Subrack_1 i-GPU 17 Position i-GPU spare i-GPU 06 to 16 i-GPU 06 Tx and Rx i-GPU spare Subrack_2 SUBRACK_0 i-GPU 01 Position i-GPU spare TRU SUBRACK_3 i-GPU 17 to 27 Ethernet HUB A1 Ethernet HUB B1 Ethernet HUB A2 Ethernet HUB B2 Position Rack layouts Subrack_0 Tx and Rx i-GPU 28 to 38 Alcatel File m43533a2.doc V2 Reference 3DF 00435 0033 RJZZA Edition 02 Status Released Date 00/12/26 All rights reserved Passing on and copying of this document, use and communication of its contents not permitted without written authorization from Alcatel Page 89/102 Installation of Digital Distribution Frame (DDF) Chapter 10: Cable mapping Cable and signal mapping for A935 i-MFS – Subrack_3 / i-GPU 01 to 05 and alarms Cable choice: L907 – 120 ohms multipair / pairs per cable Flex – 75 ohms multicoax / coax per cable SUBRACK_ / POSITION i-GPU - 01 Tx pairs PCM_0 PCM_0 PCM_0 PCM_0 PCM_7 i-GPU - 02 PCM_7 i-GPU - 03 PCM_7 i- GPU - 04 PCM_7 i-GPU - 05 PCM_7 PCM_0 i-GPU - 01 Rx pairs PCM_0 i-GPU - 05 PCM_0 Alm_1 PCM_7 i- GPU - 04 PCM_0 002 003 004 005 PCM_7 i-GPU - 03 PCM_0 001 PCM_7 i-GPU - 02 PCM_0 marking caps PCM_7 PCM_7 cable Tx 10 10 10 10 10 10 10 10 10 cable Tx cable Tx cable Tx cable Rx 001 002 5 003 004 005 cable Rx cable Rx cable Rx cable Rx 10 10 external alarms cable Alm_4 File m43533a2.doc V2 cable Tx Alcatel Reference 3DF 00435 0033 RJZZA Edition 02 Status Released Date 00/12/26 All rights reserved Passing on and copying of this document, use and communication of its contents not permitted without written authorization from Alcatel Page 90/102 Installation of Digital Distribution Frame (DDF) Chapter 10: Cable mapping Cable and signal mapping for A935 i-MFS – Subrack_2 / i-GPU 06 to 16 Cable choice: L907 – 120 ohms multipair / pairs per cable Flex – 75 ohms multicoax / coax per cable SUBRACK_ / POSITION PCM_0 PCM_0 PCM_0 Tx pairs PCM_0 PCM_0 PCM_7 cable Tx 006 PCM_7 007 i-GPU - 08 PCM_7 008 i- GPU - 09 i-GPU - 10 PCM_7 PCM_7 009 010 2 PCM_0 i-GPU - 12 PCM_7 012 PCM_0 i-GPU - 13 PCM_7 013 PCM_0 i-GPU - 14 PCM_7 014 PCM_0 i-GPU - 15 PCM_7 015 4 4 4 4 PCM_7 016 4 i-GPU - 07 PCM_7 007 PCM_0 i-GPU - 08 PCM_7 008 PCM_0 i- GPU - 09 PCM_7 009 PCM_0 i-GPU - 13 10 10 10 10 10 10 10 10 10 10 10 10 10 10 10 10 10 10 10 10 10 cable Rx i-GPU - 12 cable 16 Tx PCM_0 cable 15 Tx i-GPU - 11 10 cable 14 Tx PCM_0 cable 13 Tx 006 i-GPU - 10 cable 12 Tx PCM_7 PCM_0 cable 11 Tx PCM_0 cable 10 Tx 011 i-GPU - 06 cable Tx PCM_7 PCM_0 cable Tx i-GPU - 11 i-GPU - 16 cable Tx i-GPU - 07 PCM_0 PCM_0 Rx pairs i-GPU - 06 marking caps PCM_7 010 cable Rx cable Rx cable Rx cable 10 Rx cable 11 Rx PCM_7 PCM_7 011 012 cable 12 Rx cable 13 Rx PCM_7 013 cable 14 Rx PCM_0 i-GPU - 14 PCM_7 014 PCM_0 i-GPU - 15 PCM_7 015 PCM_0 i-GPU - 16 PCM_7 016 Alcatel File m43533a2.doc V2 cable 15 Rx cable 16 Rx Reference 3DF 00435 0033 RJZZA Edition 02 Status Released Date 00/12/26 All rights reserved Passing on and copying of this document, use and communication of its contents not permitted without written authorization from Alcatel Page 91/102 Installation of Digital Distribution Frame (DDF) Chapter 10: Cable mapping Cable and signal mapping for A935 i-MFS – Subrack_1 / i-GPU 17 to 27 Cable choice: L907 – 120 ohms multipair / pairs per cable Flex – 75 ohms multicoax / coax per cable SUBRACK_ / POSITION PCM_0 PCM_0 PCM_0 Tx pairs PCM_0 PCM_0 PCM_0 PCM_0 PCM_0 PCM_0 PCM_0 Rx pairs PCM_0 i-GPU - 17 PCM_7 i-GPU - 18 i-GPU - 19 i- GPU - 20 i-GPU - 21 i-GPU - 22 i-GPU - 23 i-GPU - 24 i-GPU - 25 marking caps 017 cable 17 Tx i-GPU - 27 i-GPU - 17 PCM_0 i-GPU - 18 PCM_7 018 PCM_7 019 PCM_7 020 PCM_7 021 PCM_7 022 PCM_7 023 PCM_7 024 PCM_7 025 PCM_7 026 4 4 4 10 10 10 10 10 10 10 10 10 10 10 10 10 10 10 10 10 10 10 10 10 cable 24 Tx cable 25 Tx 4 cable 27 Tx PCM_7 027 PCM_7 017 PCM_7 018 cable 17 Rx PCM_0 i- GPU - 20 PCM_7 020 i-GPU - 21 PCM_7 021 PCM_0 i-GPU - 22 PCM_7 022 PCM_0 i-GPU - 23 PCM_7 023 i-GPU - 25 i-GPU - 26 i-GPU - 27 6 cable 19 Rx i-GPU - 24 cable 18 Rx File m43533a2.doc V2 cable 23 Tx Alcatel 10 cable 22 Tx 019 PCM_0 cable 21 Tx PCM_7 PCM_0 cable 20 Tx i-GPU - 19 PCM_0 cable 19 Tx PCM_0 PCM_0 cable 26 Tx i-GPU - 26 PCM_0 PCM_0 cable 18 Tx cable 20 Rx cable 21 Rx cable 22 Rx cable 23 Rx cable 24 Rx PCM_7 024 cable 25 Rx PCM_7 025 cable 26 Rx PCM_7 026 PCM_7 027 cable 27 Rx Reference 3DF 00435 0033 RJZZA Edition 02 Status Released Date 00/12/26 All rights reserved Passing on and copying of this document, use and communication of its contents not permitted without written authorization from Alcatel Page 92/102 Installation of Digital Distribution Frame (DDF) Chapter 10: Cable mapping Cable and signal mapping for A935 i-MFS – Subrack_0 / i-GPU 28 to 38 Cable choice: L907 – 120 ohms multipair / pairs per cable Flex – 75 ohms multicoax / coax per cable SUBRACK_ / POSITION marking caps i-GPU - 28 i-GPU - 29 PCM_0 PCM_0 Tx pairs PCM_0 i-GPU - 30 i- GPU - 31 i-GPU - 32 PCM_0 i-GPU - 33 i-GPU - 34 PCM_0 PCM_0 PCM_0 PCM_0 PCM_0 PCM_0 PCM_0 PCM_0 Rx pairs PCM_0 i-GPU - 35 i-GPU - 36 i-GPU - 38 i-GPU - 28 i-GPU - 29 i-GPU - 30 i- GPU - 31 i-GPU - 32 i-GPU - 33 PCM_0 PCM_0 PCM_0 PCM_0 PCM_0 Alcatel PCM_7 029 PCM_7 030 PCM_7 031 i-GPU - 34 i-GPU - 35 i-GPU - 36 i-GPU - 37 i-GPU - 38 File m43533a2.doc V2 032 10 10 10 10 10 10 10 10 10 10 10 10 10 10 10 10 10 10 10 10 10 10 cable 29 Tx cable 30 Tx cable 31 Tx cable 32 Tx cable 33 Tx PCM_7 033 PCM_7 034 PCM_7 035 cable 34 Tx cable 35 Tx cable 36 Tx PCM_7 036 PCM_7 037 PCM_7 038 PCM_7 028 4 cable 37 Tx i-GPU - 37 PCM_0 PCM_0 PCM_7 PCM_0 cable 28 Tx 028 PCM_7 PCM_0 cable 38 Tx cable 28 Rx PCM_7 029 PCM_7 030 PCM_7 031 PCM_7 032 PCM_7 PCM_7 033 034 cable 29 Rx cable 30 Rx cable 31 Rx cable 32 Rx cable 33 Rx cable 34 Rx cable 35 Rx PCM_7 035 cable 36 Rx PCM_7 036 cable 37 Rx PCM_7 037 PCM_7 038 cable 38 Rx Reference 3DF 00435 0033 RJZZA Edition 02 Status Released Date 00/12/26 All rights reserved Passing on and copying of this document, use and communication of its contents not permitted without written authorization from Alcatel Page 93/102 Installation of Digital Distribution Frame (DDF) Chapter 10: Cable mapping Wire mapping connectors for A935 i-MFS: Subrack a, i-GPU - bb, 120 ohm, T(R)x (8 pairs cable) cable bb T(R)x XN00 XP00 XN01 XP01 XN02 XP02 XN03 XP03 XN04 XP04 XN05 XP05 XN06 XP06 XN07 XP07 pair pair pair pair pair pair pair pair shield 10 10 X = R: receive on Rx port X = T: transmit on Tx port Subrack a, i-GPU - bb, 75 ohm, T(R)x (8 coaxs cable) cable bb T(R)x shield Xr00 Xt00 coax Xr01 Xt01 coax Xr02 Xt02 coax Xr03 Xt03 coax Xr04 Xt04 coax Xr05 Xt05 coax Xr06 Xt06 coax Xr07 Xt07 coax 8 X = R: receive on Rx port X = T: transmit on Tx port t = tip r = ring External alarms cable brown white orange white blue shield white violet white black white EALM1 0VBAT EALM2 0VBAT EALM3 0VBAT EALM4 0VBAT MLOG MLOG 10 pairs Alcatel File m43533a2.doc V2 Reference 3DF 00435 0033 RJZZA Edition 02 Status Released Date 00/12/26 All rights reserved Passing on and copying of this document, use and communication of its contents not permitted without written authorization from Alcatel Page 94/102 Installation of Digital Distribution Frame (DDF) Chapter 10: Cable mapping Cable and signal mapping for BTS (generic configuration) marking caps BTS - Abis - Tx Abis_1 Tx BTS - Abis - Rx Abis_1 Rx 10 002 10 003 10 004 10 005 10 006 10 007 10 008 10 009 10 010 10 011 10 012 10 013 10 014 10 015 10 016 10 017 10 018 10 019 10 020 10 Almi_1 Almi_10 021 10 Almi_11 Almi_20 022 10 023 10 10 Almi_21 Almi_24 Alarmes - out Almo_1 Alcatel File m43533a2.doc V2 Abis Abis Alarm input cable Alarmes - in Alarms 001 Alarms Alarm output cable Almo_8 024 Reference 3DF 00435 0033 RJZZA Edition 02 Status Released Date 00/12/26 All rights reserved Passing on and copying of this document, use and communication of its contents not permitted without written authorization from Alcatel Page 95/102 Installation of Digital Distribution Frame (DDF) Chapter 10: Cable mapping Form sheet for connection mapping DDF mapping for: Equipment: (BSC, TC, GPRS, BTS, FH: nr./code) marking caps Remarks: _01 10 10 10 10 _05 10 _06 10 _07 10 _08 10 _09 10 _10 10 _11 10 _12 10 _13 10 _14 10 _15 10 _16 10 _17 10 _18 10 _19 10 _20 10 _21 10 _22 10 _23 10 _24 10 _02 _03 _04 Jumper connection to: Code of corespondent: Alcatel File m43533a2.doc V2 Reference 3DF 00435 0033 RJZZA Edition 02 Status Released Date 00/12/26 All rights reserved Passing on and copying of this document, use and communication of its contents not permitted without written authorization from Alcatel Page 96/102 Installation of Digital Distribution Frame (DDF) Appendix A: Tools and accessories Appendix A Tools and accessories Tools (supplier: NEXANS / ALCATEL COMPOSANTS TELECOM): • OSA3 - insertion and extraction tool - ref 93417 - 1AD 01604 0001 Test accessories (supplier: NEXANS / ALCATEL COMPOSANTS TELECOM): • disconnection shims (red)- ref 93368 • line test with plugs without disconnection, wires, 3m - ref 93795 • line test with plugs with disconnection, wires, 3m - ref 93793 • line test with plugs with disconnection, wires, 3m - ref 93797 • 120ohm jumpers with connectors, pair - length: - 1m - 93779 - 2m - 93780 - 3m - 93781 - 4m - 93982 - 5m - 93782 - 8m - 93983 • 120ohm jumpers with connectors, pair - length: - 1m - 93783 - 2m - 93784 - 3m - 93785 - 5m - 93786 Jumpers: • cable to use for jumpers without connectors: - 120 ohm - L904 pair - 1AC 00369 0008 - 75 ohm - Flex3 coax - 1AC 00362 0001 Alcatel File m43533a2.doc V2 Reference 3DF 00435 0033 RJZZA Edition 02 Status Released Date 00/12/26 All rights reserved Passing on and copying of this document, use and communication of its contents not permitted without written authorization from Alcatel Page 97/102 Installation of Digital Distribution Frame (DDF) Appendix B: CCL, Completion check list Appendix B CCL, Completion Check List IDENTIFICATION Customer name : Customer application : Site name Site address: USED DOCUMENTS Document Ed Date Document Ed Date FAULT REPORTS Date Subject SIGNATURE AND COMMENTS OF CONCERNED PEOPLE Name Signature Name Signature Name Signature Name Signature Start date End date Time spent on site COMMENTS Alcatel File m43533a2.doc V2 Reference 3DF 00435 0033 RJZZA Edition 02 Status Released Date 00/12/26 All rights reserved Passing on and copying of this document, use and communication of its contents not permitted without written authorization from Alcatel Page 98/102 Installation of Digital Distribution Frame (DDF) Appendix B: CCL, Completion check list EQUIPMENTS FOR THE TEST 01 Type Serial number Validity date - REPORT ! Record the results as the work proceeds: • • • Put a cross in the Yes | No | NA (Not Applicable) box Enter the information or measurements in the boxes provided Enter the comments referred to on page RESULTS Steps Title Yes No NA 01 Chapter Prerequisite task to start work on site Applied 02 Site documentation available 01 Chapter Safety rules and precautions Applied 01 Chapter Installation rules PCM grounding 01 Chapter Kit description Kits delivered 01 Chapter Frame installation Frame installation on wall with brackets 02 Frame installation between floor and ceiling 03 Frame installation on wall by cable way fixing 04 Grounding 01 Chapter Installation of U rail on frame Mounting 01 Chapter Installation of U rail on wall Assembly 02 Mounting 03 Grounding Alcatel File m43533a2.doc V2 Reference 3DF 00435 0033 RJZZA Edition 02 Status Released Date 00/12/26 All rights reserved Passing on and copying of this document, use and communication of its contents not permitted without written authorization from Alcatel Page 99/102 Installation of Digital Distribution Frame (DDF) Appendix B: CCL, Completion check list 01 Chapter Installation of U rail in 19” rack Assembly 02 Mounting 03 Grounding 01 Chapter Connection module installation and wiring Installation of connection modules 02 Cable preparation 03 Cable fixing 04 Wire insertion 01 Grounding 10 01 Chapter 10 Cable mapping Connection module numbering 02 cable and signal mapping 11 01 END OF INSTALLATION Site clean and services finished FAULTS # Proc N° Title Solved on: by: action: Solved on: by: action: Solved on: by: action: Any fault encountered in the course of a procedure must be entered as it arises in the above form (even if the fault is not covered by a FR, AF or ALCATEL 3000) Indicate: - in column the number of the procedure in which the fault occurred, - in column a description of the fault, and action taken if appropriate (FR, AF or ALCATEL 3000), - in the last column: the date and name of the person correcting the fault Alcatel File m43533a2.doc V2 Reference 3DF 00435 0033 RJZZA Edition 02 Status Released Date 00/12/26 All rights reserved Passing on and copying of this document, use and communication of its contents not permitted without written authorization from Alcatel Page 100/102 Installation of Digital Distribution Frame (DDF) Appendix C : DDF acceptance report Appendix C DDF acceptance report Identification Site: Address: Country: Operator Installed _ frames cable fixing OK o YES o NO o YES _ U rails o NO cable preparation OK o YES o NO o YES o NO _ connection modules groundings OK o YES o YES o NO o NO equipment fixing OK labeling OK o YES o YES o NO o NO Other o o o o o Comments Alcatel representative Customer representative Completed at ., on Completed at ., on Name Name Signature Signature Alcatel File m43533a2.doc V2 Reference 3DF 00435 0033 RJZZA Edition 02 Status Released Date 00/12/26 All rights reserved Passing on and copying of this document, use and communication of its contents not permitted without written authorization from Alcatel Page 101/102 Installation of Digital Distribution Frame (DDF) Abbreviations Abbreviations Sigle Description Abis PCM signal between BTS and BSC Ater PCM signal between BSC and TC A PCM signal between TC and MSC BTS Base Transceiver Station BSC Base Station Controller CCL Completion Check List DDF Data Distribution Frame GPRS General Packet Radio Service GPU GPRS Processing Unit GSM Global System for Mobile communication MSC Mobile service Switching Center MFS Multi-BSS Fast packet Server PCM Pulse Code Modulation TC TransCoder TRU Top Rack Unit END OF DOCUMENT Alcatel File m43533a2.doc V2 Reference 3DF 00435 0033 RJZZA Edition 02 Status Released Date 00/12/26 All rights reserved Passing on and copying of this document, use and communication of its contents not permitted without written authorization from Alcatel Page 102/102 ... (DDF) Chapter 5: Frame installation Wall fixing with bracket - Frame assembling DDF DDF 8a 8b DDF DDF 1c 1b DDF 8a DDF DDF 1a DDF DDF 8b DDF DDF 8a 1b DDF DDF DDF 1d 1c DDF Alcatel File m43533a2.doc... Chapter 4: Kit description 1c 1b DDF 1e 1a DDF DDF DDF DDF DDF DDF 7a 7b DDF DDF 7c DDF 8a DDF 8b DDF 8c DDF DDF 1c DDF DDF 1b DDF 1d DDF Alcatel File m43533a2.doc V2 Reference 3DF 00435 0033... Distribution Frame (DDF) Chapter 5: Frame installation Ceiling fixing - Frame assembly preassembled 20 to 1000 mm DDF 1a DDF DDF 8b DDF DDF 1d 8a 1b DDF DDF DDF 1c DDF Alcatel File m43533a2.doc V2 Reference