1. Trang chủ
  2. » Kỹ Thuật - Công Nghệ

Flexi multiradio BTS GSM EDGE optional items description

104 3,6K 1

Đang tải... (xem toàn văn)

Tài liệu hạn chế xem trước, để xem đầy đủ mời bạn chọn Tải xuống

THÔNG TIN TÀI LIỆU

Thông tin cơ bản

Định dạng
Số trang 104
Dung lượng 3,17 MB

Nội dung

Nokia Flexi multiradio BTS GSM EDGE optional items description Table of contents This document has 104 pages. 1 Summary of changes. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11 2 Introduction to Optional Items . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12 3 Flexi Power Module (FPMA) and submodules (FPAA and FPBA) description. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13 3.1 Flexi Power Module (FPMA) and submodules (FPAA and FPBAB) operation. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13 3.2 Flexi Power Module (FPMA) and submodule (FPAA and FPBAB) interfaces. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16 3.3 Flexi Power Module (FPMA) dimensions and weight . . . . . . . . . . . . . . 18 3.4 Flexi power submodule (FPAA and FPBAB) LED indications. . . . . . . 19 4 Flexi Power DCDC SubModule (FPDA) description . . . . . . . . . . . . . . 21 4.1 Flexi Power DCDC Module (FPDA) operation . . . . . . . . . . . . . . . . . . . 21 4.2 Flexi Power DCDC Module (FPDA) interfaces. . . . . . . . . . . . . . . . . . . 22 4.3 Flexi Power DCDC Module (FPDA) dimensions and weight . . . . . . . . 23 4.4 Flexi Power DCDC Module (FPDA) LED indications . . . . . . . . . . . . . . 24 5 Diplexer Unit (DU2A). . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 25 5.1 Technical description of Dual Band Diplex Filter (DU2A) unit . . . . . . . . 25 5.1.1 Function. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 25 5.1.2 Operation. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 25 5.1.3 Main blocks . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 26 5.2 Interfaces of the Dual Band Diplex Filter (DU2A) unit . . . . . . . . . . . . . . 27 5.3 Dimensions and weight of Dual Band Diplex Filter (DU2A) unit . . . . . . 28 6 Flexi Mounting Auxiliary Bracket (FMAA) description . . . . . . . . . . . . . . 29 7 Flexi System External Alarm Box (FSEB) . . . . . . . . . . . . . . . . . . . . . . . 30 7.1 Flexi System External Alarm Box (FSEB) operation . . . . . . . . . . . . . . . 30 7.2 Flexi System External Alarm (FSEB) interfaces . . . . . . . . . . . . . . . . . . 31 7.3 Flexi System External Alarm (FSEB) dimensions and weight. . . . . . . . 33 8 Flexi System External OVP (FSEC) description . . . . . . . . . . . . . . . . . . 34 9 Flexi Cabinet for Indoor (FCIA) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 38 9.1 FCIA cabinet construction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 38 9.2 FCIA cabinet locking . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 39 9.3 FCIA dimensions and weight. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 40 9.4 FCIA optional items . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 41 10 Flexi Cabinet for Outdoor (FCOA) description. . . . . . . . . . . . . . . . . . . . 42 10.1 Flexi Cabinet for Outdoor (FCOA) construction. . . . . . . . . . . . . . . . . . . 42 10.2 FCOA optional items . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 43 10.3 Flexi Cabinet for Outdoor (FCOA) dimensions and weight . . . . . . . . . . 46 11 Flexi Mounting Shield (FMSAFMSB) description . . . . . . . . . . . . . . . . . 47 11.1 Flexi Mounting Shield (FMSA and FMSB) operation and construction . 47 11.2 Flexi Mounting Shield (FMSA and FMSB) dimensions and weights . . . 49

Trang 1

Nokia Siemens Networks

Trang 2

The information in this document is subject to change without notice and describes only the product defined in the introduction of this documentation This documentation is intended for the use of Nokia Siemens Networks customers only for the purposes of the agreement under which the document is submitted, and no part of it may be used, reproduced, modified or transmitted

in any form or means without the prior written permission of Nokia Siemens Networks The documentation has been prepared to be used by professional and properly trained personnel, and the customer assumes full responsibility when using it Nokia Siemens Networks welcomes customer comments as part of the process of continuous development and improvement of the documentation.

The information or statements given in this documentation concerning the suitability, capacity,

or performance of the mentioned hardware or software products are given "as is" and all liability arising in connection with such hardware or software products shall be defined conclusively and finally in a separate agreement between Nokia Siemens Networks and the customer However, Nokia Siemens Networks has made all reasonable efforts to ensure that the instructions contained in the document are adequate and free of material errors and omissions Nokia Siemens Networks will, if deemed necessary by Nokia Siemens Networks, explain issues which may not be covered by the document.

Nokia Siemens Networks will correct errors in this documentation as soon as possible IN NO EVENT WILL Nokia Siemens Networks BE LIABLE FOR ERRORS IN THIS DOCUMENTA- TION OR FOR ANY DAMAGES, INCLUDING BUT NOT LIMITED TO SPECIAL, DIRECT, INDI- RECT, INCIDENTAL OR CONSEQUENTIAL OR ANY LOSSES, SUCH AS BUT NOT LIMITED

TO LOSS OF PROFIT, REVENUE, BUSINESS INTERRUPTION, BUSINESS OPPORTUNITY

OR DATA,THAT MAY ARISE FROM THE USE OF THIS DOCUMENT OR THE INFORMATION

IN IT.

This documentation and the product it describes are considered protected by copyrights and other intellectual property rights according to the applicable laws.

The wave logo is a trademark of Nokia Siemens Networks Oy Nokia is a registered trademark

of Nokia Corporation Siemens is a registered trademark of Siemens AG.

Other product names mentioned in this document may be trademarks of their respective owners, and they are mentioned for identification purposes only.

Copyright © Nokia Siemens Networks 2010 All rights reserved

f Important Notice on Product Safety

Elevated voltages are inevitably present at specific points in this electrical equipment Some of the parts may also have elevated operating temperatures.

Non-observance of these conditions and the safety instructions can result in personal injury or in property damage

Therefore, only trained and qualified personnel may install and maintain the system

The system complies with the standard EN 60950 / IEC 60950 All equipment connected has to comply with the applicable safety standards.

The same text in German:

Wichtiger Hinweis zur Produktsicherheit

In elektrischen Anlagen stehen zwangsläufig bestimmte Teile der Geräte unter nung Einige Teile können auch eine hohe Betriebstemperatur aufweisen.

Span-Eine Nichtbeachtung dieser Situation und der Warnungshinweise kann zu zungen und Sachschäden führen.

Körperverlet-Deshalb wird vorausgesetzt, dass nur geschultes und qualifiziertes Personal die Anlagen installiert und wartet

Das System entspricht den Anforderungen der EN 60950 / IEC 60950 Angeschlossene Geräte müssen die zutreffenden Sicherheitsbestimmungen erfüllen.

Trang 3

DN0946895

Issue 02A

3

Flexi Multiradio BTS GSM/EDGE Optional Items

De-scription

Id:0900d8058082e825 Confidential

Table of contents

This document has 104 pages

1 Summary of changes 11

2 Introduction to Optional Items 12

3 Flexi Power Module (FPMA) and submodules (FPAA and FPBA) descrip-tion 13

3.1 Flexi Power Module (FPMA) and sub-modules (FPAA and FPBA/B) oper-ation 13

3.2 Flexi Power Module (FPMA) and sub-module (FPAA and FPBA/B) interfac-es 16

3.3 Flexi Power Module (FPMA) dimensions and weight 18

3.4 Flexi power sub-module (FPAA and FPBA/B) LED indications 19

4 Flexi Power DC/DC Sub-Module (FPDA) description 21

4.1 Flexi Power DC/DC Module (FPDA) operation 21

4.2 Flexi Power DC/DC Module (FPDA) interfaces 22

4.3 Flexi Power DC/DC Module (FPDA) dimensions and weight 23

4.4 Flexi Power DC/DC Module (FPDA) LED indications 24

5 Diplexer Unit (DU2A) 25

5.1 Technical description of Dual Band Diplex Filter (DU2A) unit 25

5.1.1 Function 25

5.1.2 Operation 25

5.1.3 Main blocks 26

5.2 Interfaces of the Dual Band Diplex Filter (DU2A) unit 27

5.3 Dimensions and weight of Dual Band Diplex Filter (DU2A) unit 28

6 Flexi Mounting Auxiliary Bracket (FMAA) description 29

7 Flexi System External Alarm Box (FSEB) 30

7.1 Flexi System External Alarm Box (FSEB) operation 30

7.2 Flexi System External Alarm (FSEB) interfaces 31

7.3 Flexi System External Alarm (FSEB) dimensions and weight 33

8 Flexi System External OVP (FSEC) description 34

9 Flexi Cabinet for Indoor (FCIA) 38

9.1 FCIA cabinet construction 38

9.2 FCIA cabinet locking 39

9.3 FCIA dimensions and weight 40

9.4 FCIA optional items 41

10 Flexi Cabinet for Outdoor (FCOA) description 42

10.1 Flexi Cabinet for Outdoor (FCOA) construction 42

10.2 FCOA optional items 43

10.3 Flexi Cabinet for Outdoor (FCOA) dimensions and weight 46

11 Flexi Mounting Shield (FMSA/FMSB) description 47

11.1 Flexi Mounting Shield (FMSA and FMSB) operation and construction 47 11.2 Flexi Mounting Shield (FMSA and FMSB) dimensions and weights 49

Trang 4

4 DN0946895

Issue 02A

Flexi Multiradio BTS GSM/EDGE Optional Items

De-scription

Id:0900d8058082e825 Confidential

12 Flexi Mounting Kit Horizontal for 2G (FMUB) description 50

12.1 Flexi Mounting Kit Horizontal for 2G (FMUB) operation and construction 50 12.2 Technical properties of Flexi Mounting Kit Horizontal for 2G (FMUB) 51

13 Flexi BTS Module Casing (EMHA) 52

14 Flexi BTS Module Casing (EMHA) dimensions and weight 55

15 Flexi Mounting Kit for Floor, Wall and Pole (FMFA) description 56

16 Flexi Pole Installation Kit (FPIA) description 60

17 Flexi Pole Mounting Kit (FPKA) description 61

18 Pole Mounting Kit (VMPB) description 63

19 Flexi Mounting Covers for Back and Front (FMCA and FMCB) description 64 20 Multi Integrated Battery Backup Solution (MIBBU) 66

21 Talk Conversion Kit (EMIA or EMIB) 67

22 Upgrade Cable Kit (EUCA) 69

23 LMP cable delivery (ELCA) 70

24 BBU Alarm Cable delivery (EBCA) 71

25 IDC_ Roof and Side Kit (IRSA) and Outdoor Side Kit (OSKA) 72

26 Rx Diversity Sharing Kits (RDSA) 73

27 Appendix: Contents of delivery 74

27.1 Contents of the Power Module (FPMA) delivery 74

27.1.1 Contents of the power AC/DC sub-module (FPAA) delivery 75

27.1.2 Contents of the power battery sub-module (FPBA/B) delivery 75

27.2 Contents of the 24V Power Module (FPDA) delivery 77

27.3 Contents of the Flexi System External Alarm Module (FSEB) 78

27.4 Contents of the Upgrade Cable Kit (EUCA) delivery 79

27.5 Contents of the Flexi Pole Installation Kit (FPIA) delivery 80

27.6 Contents of the Flexi Pole Mounting Kit (FPKA) delivery 81

27.7 Contents of the Pole Mounting Kit delivery (VMPB) 82

27.8 Contents of Flexi Cabinet for Indoor (FCIA) delivery 83

27.9 Contents of the Flexi Mounting Kit for Batteries (FMBB) delivery 84

27.10 Contents of the Flexi Mounting Shield 6U (FMSA) delivery 85

27.11 Contents of the Flexi Mounting Shield 18U (FMSB) delivery 86

27.12 Contents of the 3 U Module Casings (EMHA) delivery 87

27.13 Contents of the mounting kit for floor, wall and pole (FMFA) delivery 88

27.14 Contents of the Flexi Mounting Covers Front and Back, 2 HU (FMCB) 90 27.15 Contents of Long Term Battery Backup Solution (MIBBU) delivery 91

27.16 Contents of the Talk Conversion Kit (EMIA) delivery 92

27.17 Contents of the Talk Conversion Kit (EMIB) delivery 94

27.18 Contents of the Flexi Mounting Auxiliary Bracket (FMAA) 97

27.19 Contents of the LMP cable delivery (ELCA) 98

Trang 5

DN0946895

Issue 02A

5

Flexi Multiradio BTS GSM/EDGE Optional Items

De-scription

Id:0900d8058082e825 Confidential

27.20 Contents the of BBU Alarm Cable delivery (EBCA) 99

27.21 Contents of the synchronisation cable deliveries (ESxA) 100

27.22 Contents of the Q1 cable delivery (EQCA) 101

27.23 Contents of the Flexi System Alarm Cable (FSAA) delivery 102

27.24 Contents of the Rx Diversity Sharing Kits (RDSA) delivery 103

27.25 Contents of Flexi System External OVP (FSEC) delivery 104

Trang 6

6 DN0946895

Issue 02A

Flexi Multiradio BTS GSM/EDGE Optional Items

De-scription

Id:0900d8058082e825 Confidential

List of figures

Figure 1 Power Module (FPMA) 13

Figure 2 FPMA: full configuration with two FPAAs and two FPBAs 14

Figure 3 FPAA LED 19

Figure 4 FPBA/B LED 20

Figure 5 Flexi Power DC/DC Module (FPDA) 21

Figure 6 Front panel of the FPDA 22

Figure 7 DU2A unit 25

Figure 8 DU2A main blocks 26

Figure 9 Flexi Mounting Auxiliary Bracket (FMAA) 29

Figure 10 FSEB interfaces 31

Figure 11 FSEB PWB 32

Figure 12 Isometric view of the FSEC 34

Figure 13 FSEC internal wiring (version 6Yxxxxxxxxx) 35

Figure 14 FSEC external wiring (version 6Yxxxxxxxxx) 36

Figure 15 FCIA cabinet 38

Figure 16 FCOA cabinet 42

Figure 17 Air filter 43

Figure 18 Site support 44

Figure 19 Heat detector 45

Figure 20 Isometric view of the FMSA 47

Figure 21 Isometric view of the FMSB 48

Figure 22 Isometric view of Flexi Mounting Kit Horizontal for 2G 50

Figure 23 EMHA casing 52

Figure 24 Flexi BTS Side Covers (FMTA) 53

Figure 25 Flexi BTS Side Covers (FMHA) 54

Figure 26 Isometric view of FMFA v 104 56

Figure 27 Isometric view of FMFA v 103 57

Figure 28 Adapter mechanics (used with FMFA version 103 or older) 57

Figure 29 External interfaces of the plinth 59

Figure 30 Flexi Pole Installation Kit (FPIA) 60

Figure 31 Flexi Pole Mounting Kit (FPKA) 61

Figure 32 FPKA with four 3U Flexi Modules 62

Figure 33 Pole Mounting Kit 63

Figure 34 FMCA: 3U back cover, 3U front cover, 2 x maintenance strap and ground-ing cable 64

Figure 35 Parts needed for installing Flexi Multiradio BTS modules in Citytalk cabinet with Talk Conversion Kit EMIA 67

Figure 36 Parts needed for installing Flexi Multiradio BTS modules in Citytalk cabinet with Talk Conversion Kit EMIB 68

Figure 37 Example of EUCA usage 69

Figure 38 Delivery contents of the FPMA 74

Figure 39 Delivery contents of the FPAA 75

Figure 40 Delivery contents of the FPBA/B 76

Figure 41 Delivery contents of the FPDA delivery 77

Figure 42 Delivery contents of the FSEB 78

Figure 43 Delivery contents of the FPIA 80

Trang 7

DN0946895

Issue 02A

7

Flexi Multiradio BTS GSM/EDGE Optional Items

De-scription

Id:0900d8058082e825 Confidential

Figure 44 Flexi pole mounting kit (FPKA) 81

Figure 45 Contents of the Pole Mounting Kit (VMPB) delivery 82

Figure 46 Delivery contents of the FMBB 84

Figure 47 Delivery contents of FMFA v 104 88

Figure 48 Delivery contents of FMFA v 103 89

Figure 49 The Talk Conversion Kit (EMIA) delivery contents 92

Figure 50 The Talk Conversion Kit (EMIB) delivery contents 94

Figure 51 Contents of the Assembly accessories bag (included in the EMIB delivery) 94 Figure 52 Contents of the Door sensor accessories bag (included in the EMIB deliv-ery) 95

Figure 53 Delivery contents of the FMAA 97

Trang 8

8 DN0946895

Issue 02A

Flexi Multiradio BTS GSM/EDGE Optional Items

De-scription

Id:0900d8058082e825 Confidential

List of tables

Table 1 FPMA front panel connectors, types and purposes 16

Table 2 FPAA front panel connectors, types and purposes 16

Table 3 FPBA/B front panel connectors, types and purposes 16

Table 4 Dimensions and weight of the FPMA 18

Table 5 FPAA LED indications 19

Table 6 FPBA/B LED indications 19

Table 7 FPDA front panel connectors, connector types and purposes 22

Table 8 Dimensions and weight of the FPDA 23

Table 9 FPDA LED indications 24

Table 10 RF connectors 27

Table 11 Dimensions and weight 28

Table 12 Interface and connector overview 31

Table 13 FSEB dimensions 33

Table 14 FSEC dimensions 36

Table 15 FSEC E4xxxxxxxxx and S1xxxxxxxxx LED indications 37

Table 16 Dimensions and weight of Flexi Cabinet for Indoor (FCIA) 40

Table 17 Dimensions and weight of the Flexi Cabinet for Outdoor (FCOA) 46

Table 18 Dimensions and weight of Flexi Mounting Shield 6U (FMSA) 49

Table 19 Dimensions and weight of Flexi Mounting Shield 18U (FMSB) 49

Table 20 Dimensions and weight of the EMHA 55

Table 21 Dimensions and weight of the FMFA 57

Table 22 FPKA delivery contents 61

Table 23 Delivery contents 63

Table 24 VMPB dimensions and weight 63

Table 25 Dimensions of the FMCA 64

Table 26 Dimensions of the FMCB 65

Table 27 Grounding cable 65

Table 28 The Power Module (FPMA) delivery content 74

Table 29 The FPAA power sub-module delivery content 75

Table 30 The FPBA/B power sub-module delivery content 75

Table 31 The 24V Power Module (FPDA) delivery content 77

Table 32 Flexi System External Alarm Module (FSEB) delivery contents 78

Table 33 The Flexi BTS Upgrade Cable Kit (EUCA) delivery contents 79

Table 34 The Flexi Pole Installation Kit (FPIA) delivery content 80

Table 35 The Flexi pole mounting kit (FPKA) delivery content 81

Table 36 Contents of the Pole Mounting Kit (VMPB) delivery 82

Table 37 The Flexi Cabinet for Indoor (FCIA) delivery contents 83

Table 38 Flexi Mounting Kit for Batteries (FMBB) delivery (used with Flexi Cabinet for Indoor) 84

Table 39 The Flexi Mounting Shield 6U (FMSA) delivery content 85

Table 40 The Flexi Mounting Shield 18U (FMSB) delivery content 86

Table 41 The Flexi Module Casings for 3 U modules (EMHA) delivery contents 87 Table 42 The FMFA v 104 delivery content 88

Table 43 The FMFA v 103 delivery content 88

Table 44 The Flexi Mounting Covers Front and Back, 2 HU (FMCB), needed with Flexi Power DC/ DC Module 24 V (FPDA) 90

Trang 9

DN0946895

Issue 02A

9

Flexi Multiradio BTS GSM/EDGE Optional Items

De-scription

Id:0900d8058082e825 Confidential

Table 45 The Long Term Battery Backup Solution (MIBBU) delivery content 91

Table 46 The Talk Conversion Kit (EMIA) delivery contents 92

Table 47 The Talk Conversion Kit (EMIB) delivery contents 95

Table 48 The Flexi Mounting Auxiliary Bracket (FMAA) delivery contents 97

Table 49 LMP cable delivery (ELCA) 98

Table 50 BBU Alarm Cable Kit delivery (EBCA) 99

Table 51 Synchronisation cable deliveries (ESUA/ESFA/ESLA) 100

Table 52 Q1 cable delivery (EQCA) 101

Table 53 Flexi System Alarm Cable (FSAA) 102

Table 54 Rx Diversity Sharing Kit (RDSA) 103

Table 55 Flexi System External OVP (FSEC) 104

Trang 11

1 Summary of changesChanges between issues 02A and 02

Updated section:

• Contents of the Rx Diversity Sharing Kit (RDSA) delivery is updated for the cable

code and quantity

New section added:

• Rx Diversity Sharing Kits (RDSA).

• Contents of Flexi System External OVP (FSEC) delivery

Changes between issues 02 and 01

Trang 12

Introduction to Optional Items

2 Introduction to Optional Items

This document describes the optional items available for Flexi Multiradio BTS It describes the modules in terms of their function as well as their dimensions and weight and the interfaces, if applicable The document also lists the ordering codes for the optional items

Trang 13

Flexi Power Module (FPMA) and submodules (FPAA

and FPBA) description

Id:0900d805807fba9aConfidential

3 Flexi Power Module (FPMA) and submodules (FPAA and FPBA) description

3.1 Flexi Power Module (FPMA) and sub-modules (FPAA and

• Flexi Power AC/DC sub-module 200-240 V AC (FPAA)

• Flexi Power Battery sub-module (FPBA)The maximum number of sub-modules in an FPMA is four

For installation instructions, see section Installing Flexi Power Module (FPMA) in the

Installing Flexi Multiradio BTS GSM/EDGE Optional Items document.

The FPMA is presented in the following figures

Figure 1 Power Module (FPMA)

Trang 14

Flexi Power Module (FPMA) and submodules (FPAA

and FPBA) description

Figure 2 FPMA: full configuration with two FPAAs and two FPBAsFor examples of how many FPMAs are required for common configurations, see section

Common configurations in Creating Stack, Wall and Pole Configurations for Flexi

Multi-radio BTS GSM/EDGE, Creating FCIA Configurations for Flexi MultiMulti-radio BTS GSM/EDGE and Creating FCOA Configurations for Flexi Multiradio BTS GSM/EDGE.

The FPMA can support 1-phase and 3-phase AC input The nominal input voltage is 200-240 V AC (the operating voltage range is 180 - 276 V AC) The maximum output power from the FPMA is 4kW (with 4 FPAAs)

Flexi Power AC-DC sub-module (FPAA)

The main function of the FPAA is to provide the BTS with nominal 48 V DC power from

an AC supply Maximum DC output power of one FPAA module is 1000 W A nominal

48 V DC supply is intended for BTS internal use only (a nominal 48 V DC supply is not intended for 3rd party equipment because they may require lower conducted emission level than EN55022 Class A) The FPAA includes its own integrated self-controlled fan

In case the fan fails, an alarm is generated and the FPAA has to be replaced (the fan alone cannot be replaced)

The FPAA unit remembers the main control switch position If the FPAA power is switched to Standby, the power remains OFF after input voltage interrupt

The stand-by switch is used for switching the FPAA unit ON/Stand-by when AC input voltage has been connected to the FPAA unit

Flexi Power Battery sub-module (FPBA/B)

The Flexi Power Battery Sub-Module (FPBA/B) is a separate optional sub-module used together with the FPAA

!

Risk of thermal runaway of the battery, because temperature compensation of charging voltage is not supported Do not connect an external lead acid battery for longer backup times to a nominal 48 V DC supply

Trang 15

Flexi Power Module (FPMA) and submodules (FPAA

and FPBA) description

Id:0900d805807fba9aConfidential

The FPBA/B provides short-term battery backup time when the AC power mains is down

on a Flexi BTS site The FPBA is a lithium ion battery and the FPBB is a Lithium Ferrite battery The maximum DC output power from one FPBA/B module is 1000 W The input power for the BTS cannot exceed the maximum output power of the installed batteries Otherwise the batteries do not provide the BTS with the needed power during power failure

The power switch of the FPBA/B unit controls input power Batteries can be drained by the BTS if the power switch is set to OFF position

The stand-by switch is used for switching the FPBA/B unit to ON/Stand-by when AC input voltage has been connected to the FPBA/B unit

g Do not install the FPBA and FPBB in parallel If used in parallel, one of these two battery types will discharge faster than the other causing an unbalance between the batteries

Lightning protection requirements

• +/- 2 kV, 1.2/50 µs pulse, Rs=(2 Ω + 10 Ω ) (line to ground, common)

• +/- 1 kV, 1.2/50 µs pulse, Rs=2 Ω (line to line, differential)

• +/- 6 kV, 1.2/50 µs pulse, Rs=2 Ω (each phase conductor to green-wire ground or neutral conductor, neutral conductor and green-wire ground)

Trang 16

3.2 Flexi Power Module (FPMA) and sub-module (FPAA and

FPBA/B) interfacesFPMA front panel connectors

The connectors on the FPMA front panel, their types and purposes are listed in the table below

FPAA front panel connectors

There is a stand-by switch on the front panel of the FPAA The stand-by switch is used for switching the FPAA unit ON/stand-by

The connectors on the FPAA front panel, their types and purposes are listed in the table below

FPBA/B front panel connectors

There is a stand-by switch on the front panel of the FPBA/B

The connectors on the FPBA/B front panel, their types and purposes are listed in the table below

Connector Type Purpose

Power supply in Terminal block AC main power supply inPower supply out 2-wire DC cable 4 x multi-

beam

DC feed to the BTS

Table 1 FPMA front panel connectors, types and purposes

Connector Type Purpose

AC cable connector Mate-N-Lock AC input

DC connector Multi-beam power supply

connector

DC outputAlarm connector 2 x RJ-45* Alarms**

Operational state visual cation

indi-tri-colour LED FPAA state or alarm

indica-tion

Table 2 FPAA front panel connectors, types and purposes

Connector Type Purpose

DC input/output connector Multi-beam power supply

connector

DC input and output

Table 3 FPBA/B front panel connectors, types and purposes

Trang 17

*for chaining **Alarm 2 (AL02): maintenance needed (possible reasons are unit failure, output power

is low or unit has reached end of it's life)

**Unit has an input for Alarm 1 (AL01) from FPAA unit (Alarm 1 is a trigger for battery discharging)

Alarm connector 2 x RJ-45* Alarms**

Operational state visual cation

indi-tri-colour LED FPBA state or alarm

indica-tion

Connector Type Purpose

Table 3 FPBA/B front panel connectors, types and purposes (Cont.)

Trang 18

3.3 Flexi Power Module (FPMA) dimensions and weight

The following table lists the dimensions and weight for Flexi Power Module (FPMA)

(16.6 in.)Depth with covers 560 mm

(22.1 in.)Weight (empty) < 11 kg

(< 24.3 lbs)Weight

(fully equipped with one AC/DC power module and batteries)

28 kg(61.9 lbs)

Table 4 Dimensions and weight of the FPMA

Trang 19

3.4 Flexi power sub-module (FPAA and FPBA/B) LED

indica-tionsFPAA LED indications

The FPAA LED indications are explained in the table below Read the information on LED indications thoroughly A blinking red LED does not always require removing the module

See the following figure for the location of the FPAA LED

Figure 3 FPAA LED

FPBA/B LED indications

The FPBA/B LED indications are explained in the table below

The LED's slow blinking frequency is 1 Hz (1 sec) and fast blinking frequency 2 Hz (0.5 sec)

Colour Explanation

Yellow Stand-by (AC connected)

Red, blinking Unit operating with abnormal input voltage

Table 5 FPAA LED indications

Colour Explanation

Yellow Stand-by (DC connected from FPAA)Ggreen Normal operation, battery OK Green, blinking slowly Charging

Green, blinking fast DischargingBlinking fast between green and yellow Forced discharge modeRed, blinking fast Minor alarm

Table 6 FPBA/B LED indications

DN70350654LED

Trang 20

Figure 4 FPBA/B LED

Trang 21

4 Flexi Power DC/DC Sub-Module (FPDA) description

4.1 Flexi Power DC/DC Module (FPDA) operation

Flexi Power DC/DC Module (FPDA) is an optional stand-alone 2 kW DC/DC module.The FPDA converts nominal 24 V DC input voltage (normally negative grounded) 53-55

V DC output voltage The 53-55 V DC is then distributed to BTS loads When the BTS power load is more than 2 kW, multiple FPDAs can be installed in parallel When FPDAs are used in parallel, a maximum of two DC cables can be installed together at each output terminal

Conducted emission level of the 53-55 V DC supply is according to the standard EN55022 Class A The 53-55 V DC supply is intended for BTS internal use only (the 53-

55 V DC supply is not intended for 3rd party equipment because they may require lower conducted emission level than EN55022 Class A)

The FPDA includes its own integrated self-controlled fan In case the fan fails, an alarm

is generated and the fan has to be replaced

For installation instructions, see section Installing Flexi Power DC/DC Module 24V FPDA in the Installing Flexi Multiradio BTS GSM/EDGE Optional Items document.

The FPDA is presented in the following figure

Figure 5 Flexi Power DC/DC Module (FPDA)

!

Risk of thermal runaway of the battery, because temperature compensation of charging voltage is not supported Do not connect an external lead acid battery for longer backup times to the 53-55 V DC supply

DN70150502

Trang 22

4.2 Flexi Power DC/DC Module (FPDA) interfaces

There is a stand-by switch on the front panel of the FPDA

The connectors on the FPDA front panel, their types and purposes are listed in the table below

The FPDA front panel is presented in the following figure

Figure 6 Front panel of the FPDA

Connector Connector type Purpose

Input connector M10 bolts DC inputOutput connector M10 bolts DC outputAlarm connectors 2 x RJ-45* Alarms**

Table 7 FPDA front panel connectors, connector types and purposes

DN70141402

GNDLED

Trang 23

4.3 Flexi Power DC/DC Module (FPDA) dimensions and weight

The following table lists the dimensions and weight for the FPDA

(16.6 in.)Depth with covers 560 mm

Trang 24

4.4 Flexi Power DC/DC Module (FPDA) LED indications

The FPDA has a tri-colour LED on the front panel to indicate the operational status of the module and all fault conditions during operation Read the information on LED indi-cations thoroughly A blinking red LED does not always require removing the module The LED indications of the FPDA are listed and explained in the table below

Colour Explanation

Red, blinking Abnormal input voltage

Table 9 FPDA LED indications

Trang 25

5 Diplexer Unit (DU2A)

5.1 Technical description of Dual Band Diplex Filter (DU2A)

unit

5.1.1 Function

The Dual Band Diplex Filter Unit (DU2A) either combines signals of different frequency bands onto one antenna, or splits an antenna signal into different frequency bands It handles TX and RX signals from the GSM/EDGE 800/900 bands and the GSM/EDGE 1800/1900 bands

For more information on Dual Band Diplex Filter (DU2A), see Nokia Siemens Networks

Antenna Systems Operating Documentation.

Figure 7 DU2A unit

Lightning protection

The centre pin of the DU2A unit antenna port is DC grounded This connection prevents

a charge buildup on the antenna and protects th DU2A unit against lightning

5.1.2 Operation

The DU2A unit operates on the following frequency bands:

1 Dual band antenna

Trang 26

Diplexer Unit (DU2A)

• GSM/EDGE 800/900 band – 824 to 960 MHz

• GSM/EDGE 1800/1900 band – 1710 to 1990 MHzThe normal operating temperatures for the DU2A unit are -10° C to 65° C (14° F to 149° F) However, the unit can operate in temperatures as low as -33° C (-27.4° F) with degraded RF performance

DN03418705

Port 900

Dual bandantenna

Port 1800

Trang 27

5.2 Interfaces of the Dual Band Diplex Filter (DU2A) unit

Interface Connector type

Antenna 7/16, flange female

900 7/16, flange male, 800/900-band

input/out-put

1800 7/16, flange male, 1800/1900-band

input/output

Table 10 RF connectors

Trang 28

5.3 Dimensions and weight of Dual Band Diplex Filter (DU2A)

Trang 29

6 Flexi Mounting Auxiliary Bracket (FMAA) description

The Flexi Mounting Auxiliary Bracket (FMAA) can be used to mount auxiliary boxes (FSEB, FSEC, or LMUB Outdoor) in pole, wall, stack, or EMIA/EMIB installations One FSEB can be installed to the Citytalk Cabinet without the use of FMAA The FMAA must

is installed on top of a casing It cannot be installed as a standalone part

If FMAA is installed to a Citytalk Cabinet where Talk Conversion Kit EMIB is used, EMHA has to be ordered separately

The FMAA is mounted to the top casing in horizontal stacks and the outer casing in vertical installations The auxiliary boxes are then mounted to the FMAA based on their own installation principles There is enough space for a maximum of one FSEC box and one FSEB box or two FSEC boxes If an LMUB Outdoor is mounted on the FMAA, there

is not enough space for another box

Figure 9 Flexi Mounting Auxiliary Bracket (FMAA)

DN70449903

Trang 30

Flexi System External Alarm Box (FSEB)

7 Flexi System External Alarm Box (FSEB)

7.1 Flexi System External Alarm Box (FSEB) operation

The FSEB box is used for extending the Flexi BTS alarm connector to support minimum

12 and maximum 24 alarm interfaces The lower limit of 12 alarm interfaces is built into the System Module Support for the fire detector is also provided The FSEB box provides IP65 protection

In outdoor applications, the box can be attached to the outdoor cabinet roof There are fixing points for the FSEB in the outdoor cabinet In indoor or stacked applications, the box is attached in the proximity of the modules, for example, on a wall

The Flexi Mounting Auxiliary Brackets (FMAA) can be used to mount the FSEB on the top or outer casings in pole, wall, and stack configurations The brackets are mounted

on the top or outer casing using the existing connection pin holes See the Appendix A Contents of delivery section in this document for product ordering and delivery contents details

For installation instructions, see section Installing Flexi System External Alarm (FSEB)in

the Installing Flexi Multiradio BTS GSM/EDGE Optional Items document.

Trang 31

7.2 Flexi System External Alarm (FSEB) interfaces

See the figure below for the FSEB mechanical interfaces:

Figure 10 FSEB interfaces

PWB interface

The PWB interface and connectors are presented in the table below

See the following figure for the FSEB PWB

Interface Type Description

EACX-I Sub-D37, female • 12 direct alarm inputs

• 6 alarm outputs (ESM extension, com-patible to EAC on ESM)

EACX-S 10 SMDK1/6-3.5 60 pin screw terminal

combines I, II

EACX-Fire detector power supply

Screw terminal DC power supply for the

optional fire detectorESM Sub-D37, male Interface to the System

Module, CAN busEACX-II Sub-D37, female 12 alarm inputs via CAN

bus

Table 12 Interface and connector overview

BTS interconnectioncable

UltraSite and Talkswap cases

EAC M16

Grounding point

DN70283679

ESD

Trang 32

Figure 11 FSEB PWB

Trang 33

7.3 Flexi System External Alarm (FSEB) dimensions and

weight

The dimensions and weight of the FSEB are presented in the following table

The mounting dimensions of the FSEB enclosure are 110 mm x 324 mm (4.3 in x 12.8 in.)

The material of the box is plastic

Trang 34

Flexi System External OVP (FSEC) description

8 Flexi System External OVP (FSEC) tion

descrip-Flexi System External OVP (FSEC) protects descrip-Flexi Multiradio sub-modules against surge pulse(s) in power feeding lines The FSEC is used to provide power to the FCSA when the FCSA is installed without the MIBBU (WPUB or WPUC)

There are three versions of the FSEC, which are separated from each other by the first two digits of the factory code:

• 6Yxxxxxxxxx

• E4xxxxxxxxx

• S1xxxxxxxxxThis section describes protection device only for DC lines in the feederless site solution The FSEC gives Class II (C, T2) protection for DC power feed and provides IP65 pro-tection For FSEC installation instructions, see section Installing Flexi System External OVP (FSEC) in the Installing Flexi Multiradio BTS GSM/EDGE Optional Items docu-

ment

The FSEC box is also used for altering the DC cable diameter

The FSEC does not require regular maintenance

The product code of Flexi System External OVP (FSEC) is 470323A

Figure 12 Isometric view of the FSECSee the following figures for the internal and external wiring of the FSEC

DN70154491

Trang 35

Figure 13 FSEC internal wiring (version 6Yxxxxxxxxx)

FSEC

VAL-MS

60 ST VAL-MS

Trang 36

Flexi System External OVP (FSEC) description

Figure 14 FSEC external wiring (version 6Yxxxxxxxxx)

Trang 37

FSEC connectors

In the FSEC, there are screw terminals for input and output cables There are four pieces of screw terminals for AWG 2 cables and for earthing two PEs (protective earthing GND) terminals for AWG 2 cable size A 2-meter DC cable is included in the FSEC delivery

FSEC LED indications

See the following table for the FSEC LED indications

g FSEC 6Yxxxxxxxxx version has a trip switch instead of an LED

Off Overvoltage protection tripped Module needs

replacing

Table 15 FSEC E4xxxxxxxxx and S1xxxxxxxxx LED indications

Trang 38

Flexi Cabinet for Indoor (FCIA)

9 Flexi Cabinet for Indoor (FCIA)

9.1 FCIA cabinet construction

Flexi BTS Indoor cabinet (FCIA) is used for indoor installations requiring a secure cabinet or large indoor configurations exceeding 22U requiring earthquake protection Flexi BTS Indoor cabinet (FCIA) has a cabinet core made of an aluminium chassis enclosed with aluminium doors and sides The FCIA cabinet does not carry any electri-cal functionality; there are no traditional backplanes or electronics The cable entries are located at the top of the cabinet External cables are connected directly to the Flexi modules inside the cabinet

The following optional modules can be mounted to the FCIA cabinet:

• Integrated long term battery backup solution (MIBBU)

• Flexi Power Rectifier (FPRx)

• EAC connection box (FSEB)

• Overvoltage protection box (FSEC)

• Nokia Siemens Networks LMUB Outdoor (LMU)

Figure 15 FCIA cabinet

Trang 39

9.2 FCIA cabinet locking

The cabinet door can be locked with a door-open key When the key is turned wise, the door opens and when it is turned clockwise, the door is locked

anticlock-The cabinet can also be fitted with an optional security lock for additional protection anticlock-The security lock functions in a similar way with the BTS lock

Trang 40

9.3 FCIA dimensions and weight

See the following table for the dimensions and weight of the Flexi Cabinet for Indoor (FCIA)

(empty cabinet)

62 kg (136 lbs.)Free space for modules 36 U

Table 16 Dimensions and weight of Flexi Cabinet for Indoor (FCIA)

Ngày đăng: 20/01/2016, 15:41

TỪ KHÓA LIÊN QUAN