DOI:10.4491/eer.2010.15.4.215 pISSN 1225-1025 eISSN 2005-968X Environ. Eng. Res. 2010 December,15(4) : 215-223 Research Paper 215 © Copyright The Korean Society of Environmental Engineers http://www.eer.or.kr Appropriate Methods in Determining the Event Mean Concentration and Pollutant Removal Efficiency of a Best Management Practice Marla C. Maniquiz 1 , Jiyeon Choi 1 , Soyoung Lee 1 , Hye Jin Cho 2 , Lee-Hyung Kim 1† 1 Department of Civil and Environmental Engineering, Disaster Prevention Research Center, Kongju National University, 275 Budaedong, Seobukgu, Cheonan 331-717, Korea 2 Highway Research Division, Infrastructure Research Department, Korea Institute of Construction Technology, Koyang 411-712, Korea Abstract This study attempted to develop and suggest a more appropriate method for the determination of event mean concentration (EMC) and pollutant removal efficiency of a stormwater best management practice (BMP) considering rainfall. The stormwater runoff and hydrologic data gathered from 22 storm events during a 28-month monitoring period on a swirl and filtration type of BMP were used to evaluate the developed methods. Based on the findings, the modified EMC method resulted in lower (average) values than the overall EMC, although the differences were not significant (P>0.05). By comparison, the developed ‘Rainfall Occurrence Ratio’ (ROR) method was most significantly correlated (r=0.967 to 988, P<0.009) with the other existing removal efficiency determination methods such as the ‘Efficiency Ratio’ (ER), ‘Summation of Loads’ (SOL) and ‘Regression of Loads’ (ROL) methods. In addition, the ROR method gave the highest efficiency values, with no significant differences with any of the pollutant parameters, unlike the other three methods. These results were obtained because the ROR method integrated both pollutant loading and rainfall, which are not considered by the other three methods. Therefore, this study proved the suitability of the modified EMC and ROR methods for application in other BMP moni- toring studies. Keywords: Best management practice, Event mean concentration, Efficiency, Filtration, Rainfall occurrence ratio method, Stormwater sequently, the MOE introduced the total maximum daily load (TMDL) approach in 2004. The TMDL regulates or controls the pollution load discharged below the total amount allowed to at- tain the water quality target of streams [6]. The MOE is aggres- sively pursuing the implementation and compliance with the TMDL for watershed protection, and effective control of NPS is believed to be the key method for successfully meeting the TMDL [7, 8]. Changes in management policies have resulted in the introduction of pilot projects, termed ‘best management practices’ (BMP), adopted from the United States. The objectives of the program are to determine catchment areas, determine runoff characteristics and evaluate the treatment performance of structural BMPs, as many introduced in Korea have only been based from literature studies that do not reflect the climatic characteristics and geographical features of the country. The re- sults of BMP case studies will be used to facilitate the design of similar BMP types and optimize NPS management policies (e.g., TMDL) in Korea. Based on the National Pollutant Removal Performance Da- tabase for Stormwater Treatment Practices of the United States 1. Introduction The constant expansion of water related infrastructure such as sewage treatment plants by the Korean Government has con- tributed to a notable reduction of point source pollution. Yet, nonpoint source (NPS) pollution is increasingly affecting water quality [1]. In 2003, the contribution of NPS loadings to major rivers accounted for almost half the total loading, and is pre- dicted to rise to 70% by 2015 if no adequate control measures are introduced [2]. Sprawl, which is the irresponsible develop- ment, is the major contributor to the increase in NPS loadings and volume of stormwater runoff. Bannerman et al [3] found that streets with impervious surfaces contained the highest pol- lutant loads in most land use categories. Impervious covers can double, triple, quadruple or even quintuple peak discharge [4]. Urban stormwater managers seek technologies that are able to address the flow and water quality impacts of urbanization [5]. The pollutant concentration-restricting approach by the Ministry of Environment (MOE) has not been very effective at improving the water quality of the major rivers in Korea. Con- Received October 01, 2010 Accepted November 22, 2010 † Corresponding Author E-mail: leehyung@kongju.ac.kr Tel: +82-41-521-9312 Fax: +82-41-568-0287 This is an Open Access article distributed under the terms of the Creative Commons Attribution Non-Commercial License (http://creativecommons. org/licenses/by-nc/3.0/) which permits unrestricted non-commercial use, distribution, and reproduction in any medium, provided the original work is properly cited. Marla C. Maniquiz, Jiyeon Choi, Soyoung Lee, Hye Jin Cho, Lee-Hyung Kim 216 DOI:10.4491/eer.2010.15.4.215 water runoff and was responsible for the removal of sediments, free-floating oil and debris by the mechanism of sedimentation, the runoff then flowed directly to the internal spillways across the second device, which was a filtration chamber that allowed runoff to permeate through the pores of perlite filter cartridges via filtration. Subsequently, the treated runoff was channeled through an outlet pipe and discharged to the adjacent stream. 2.1.2. Storm Event Sampling A total of 22 storm events were sampled during the monitor- ing period from 06/2006 to 10/2008 to evaluate the pollutant removal efficiency of the swirl and filtration system in the treat- ment of stormwater runoff. Continuous flow measurements were performed and rainfall data collected to obtain a relatively unbiased approximation of the pollutant mass loads. The total sampling time was adjusted to approximate the time during which the “first flush” was processed [10]. Generally, at least 12 samples were manually collected at both the inlet and outlet. Typical water quality parameters were measured, including TSS, biochemical oxygen demand (BOD), chemical oxygen demand (COD), dissolved organic carbon (DOC), TN, TP, heavy metals (zinc, lead, etc.), and oil & grease (O&G). Analyses of these pa- rameters were performed in accordance with standard methods [11]. 2.2. Calculations and Data Analyses 2.2.1. Event Mean Concentration The EMC is an important factor in predicting the total pol- lutant load, which has made the EMC a critical parameter for estimating the contribution of runoff to receiving waters [12, 13]. The EMC was used to quantify the average pollutant load washed off during a storm event with respect to the event runoff volume. The pollutant loading for a storm event is calculated by the summation of loadings during each sampling period using Environmental Protection Agency (U.S. EPA), the median per- formances of filtering practices for total suspended solids (TSS), total nitrogen (TN) and total phosphorus (TP) were 86, 32 and 50%, respectively [9]. It has to be emphasized that the median removal efficiency was used instead of the mean that resulted in higher values. The issue of reporting pollutant removal efficien- cies needs to be addressed, particularly for each type of BMP, because if a wide range of removal efficiencies exists, employ- ing an appropriate stormwater treatment strategy will be diffi- cult. Therefore, this study aimed to develop a more appropriate method for the characterization of stormwater runoff using the event mean concentration (EMC) and calculate the pollutant removal efficiency of a stormwater runoff treatment system for BMPs. Although existing methods are available and currently practiced in most BMP studies, the uncertainties in reporting overall average EMC and removal efficiency values should be eliminated, or at least reduced. The data used in this study was obtained from a 28-month monitoring during 22 storm events on a swirl and filtration system, a type of BMP for the treatment of stormwater runoff. 2. Materials and Methods 2.1. Site Description and Monitoring Scheme 2.1.1. Site Location and Facility Description A swirl and filtration system (surface area=19.2 m 2 ) was in- stalled in an asphalt-paved parking lot (100% impervious), which drained a 10,700 m 2 catchment area. The main function of the facility was to remove sediments, suspended solids, particu- late pollutants, petroleum hydrocarbons, heavy metals and nu- trients from stormwater runoff by means of sedimentation and filtration mechanisms. Fig 1 shows a detailed description of the system. The facility was comprised of two devices in sequence; first, a swirl tank, which provided pre-treatment of the storm- Fig. 1. Schematic of the swirl and filtration system. Appropriate Methods in Determining the Event Mean Concentration and Pollutant Removal Efficiency of a Best Management Practice 217 http://www.eer.or.kr Second, the “summation of loads (SOL) method” [14], which is based on the ratio of the summation of the total incoming loads to that of the total outgoing loads (Eq. 4). ∑ ∑∑ − = loading Inlet loading Outletloading Inlet (%) Removal (4) Third, the “regression of loads (ROL) method” [16], where the regression efficiency is defined in terms of the slope (β) of a least squares linear regression of the inlet and outlet pollutant loads, with the intercept constrained to zero (Eq. 5). 11 loading Inlet loading Outlet (%) Removal −=−= β (5) Finally, another method, termed the “rainfall occurrence ratio (ROR) method” was proposed and used in this study to evaluate the efficiency. The ROR method was developed to consider the variability of the rainfall characteristics at the monitoring site that might affect the average removal efficiency. The removal ef- ficiency can be calculated by multiplying the average removal efficiency obtained from the ER method by the rainfall occur- rence ratio, n i /n t (Eq. 6). The rainfall occurrence ratio in Table 1 equals the number of rainy days for a specific rainfall range divided by the total number of rainy days during the entire mon- itoring period. )( ∑ ×= ratio occurence Rainfall(ER) efficiency Removal(%) Removal (6) All statistical hypotheses were tested at the 5% level (α = 0.05) using a one-way analysis of variance (ANOVA). The SYSTAT 12 software package (© SYSTAT Software Inc., Richmond, CA, USA, 2007) and OriginPro 7.5 SRO v7.5714 (B714) (© OriginLab Cor- poration, Wellesley, MA, USA, 1991-2003) were used for the sta- tistical analyses and plotting of data. 3. Results and Discussion 3.1. Hydrologic Data 3.1.1. Rainfall The rainfall during the monitoring period between 06/2006 and 10/2008 is shown in Fig. 2. A steep accumulated rainfall curve in Fig. 2(a) was apparent during the summer seasons, from June to August, when most of the rainfall occurred. In Korea, a typical rainfall event averages 14 mm. However, the median rainfall is 5 mm lower than the mean which suggests most rainfall events in Korea are small. In fact, almost 68% of the rainfall that occurred the volume (or flow rate) for that period. The equation below is used for the determination of the EMC: eventper volumerunoff total eventper loadingpollutant total 1 V n i ii CV EMC ∑ = == (1) where EMC = event mean concentration, mg/L; V = total runoff volume per event, L; V i = runoff volume proportional to the flow rate at time i, L; C i = pollutant concentration at time i, mg/L; and n = total number of samples during a single storm event Based on the above equation, the EMC calculated for each storm event only represents the concentration with respect to the flow or volume which might lead to overestimated or underestimat- ed values when arithmetically averaged for the total number of storm events. For instance, a storm with little rainfall will result in a high EMC value, while that with large rainfall will yield a small EMC value because the EMC is averaged over the entire storm event. Therefore, a more specific approximation of the average EMC over the entire monitoring period was developed using the rainfall ratio, α i /α t (see Table 1). The equation for the calculation of the modified EMC in this study is shown below: 1 t 10mm 10 20mm i m 10mm 10 20mm i i t t t EMC EMC EMC EMC α α α α α α − − = = + + ∑ (2) where EMC m = modified average EMC, mg/L; EMC i = calculated average EMC based on the rainfall range i, mg/L; α i = total rain- fall depth within the rainfall range i, mm; α t = total rainfall depth, mm; and t = total number of rainfall ranges The rainfall ranges can be selected based on the rainfall char- acteristics. In this study, three ranges were chosen, as follows: less than 10 mm, 10 to 20 mm and greater than 20 mm of rainfall. The EMC for each pollutant was calculated for each event and then categorized for each of the rainfall ranges. Finally, the over- all EMC was computed and compared with that of the modified EMC. 2.2.2. Removal Efficiency Various efficiency methods are used by investigators in BMP monitoring studies to evaluate pollutant removal efficiencies [14]. In this study, four methods were selected and applied to assess the efficiency of the swirl and filtration system. First, the “efficiency ratio (ER) method” [15], which is defined in terms of the average removal efficiency of pollutants for each storm event (Eq. 3). EMC inlet Average EMC outlet AverageEMC inlet Average (%) Removal − = (3) Table 1. Total rainfall and number of occurrences (06/2006 to 10/2008) Rainfall range Total number of rainy days (n) Occurrence ratio a) (n i /n t ) Total rainfall (mm) Rainfall ratio b) ( α i /α t ) <10 mm 149 0.642 446 0.124 10 to 20 mm 28 0.121 386.9 0.107 >20 mm 55 0.237 2 , 772.3 0.769 Cumulative 232 1 3 , 605.2 1 a) Ratio of rainfall occurrences (for each range) to total rainfall occurrences . b) Ratio of rainfall (for each range) to total rainfall . Marla C. Maniquiz, Jiyeon Choi, Soyoung Lee, Hye Jin Cho, Lee-Hyung Kim 218 DOI:10.4491/eer.2010.15.4.215 rea during the study period. Due to the high rainfall intensity of 15.2 mm/hr during the 08/26/2006 storm (data not shown), the runoff exceeded the storage capacity of the facility and resulted in extreme overflow. 3.2. Runoff Water Quality 3.2.1. Pollutant Pattern The plots in Fig. 3 illustrate the typical patterns of pollutant concentrations at the inlet and outlet of the swirl and filtration system with respect to flow and time. Apparently, the existence of the first flush was clearly identified for the TSS and metal con- centrations during a relatively short period at the very beginning of the storm only at the inlet. Metals are known to often move from paved surfaces used for transportation by being adsorbed onto particulate materials [17]. The outlet concentration did not exhibit a first flush effect, signifying the efficiency of treatment via the swirl and filtration system. Nonetheless, the outlet con- centration only appeared to be slightly reduced, and remained almost constant during the entire storm event, signifying the limitation of the swirl and filtration system in the treatment of stormwater runoff from paved areas. was below 10 mm, with 76% below 20 mm Fig. 2(b). The sum of the maximum rainfall for each year over a three year period was about one-third of the total rainfall over three years. Table 1 provides the rainfall data used in the calculation of the modified EMC (Eq. 2) and efficiency using the ROL method (Eq. 6). Accordingly, the rainfall ratio and occurrence ratio were very different for the <10 mm and >20 mm rainfall ranges. It has to be emphasized that even though the majority of storms oc- curred with rainfall <10 mm, the total rainfall was still small. On the other hand, almost similar ratios were observed for the 10 to 20 mm rainfall range, indicating that this range was least af- fected by the modified EMC calculations. 3.1.2. Storm Event The summary of the monitored event data are provided in Table 2, which includes antecedent dry day (ADD), total rain- fall, runoff duration and the sampling frequency ratio. The me- dian rainfall was 10.5 mm, suggesting that most of the sampled storm events were less than 10 mm (50% of the total sampled events). However, the sampling ratios of each rainfall range were highly correlated (r=0.99, P<0.0001) with the occurrence ratio of rainfall, as shown in Table 1, which means that the conducted sampling trips were representative of the overall rainfall in Ko- Fig. 2. Rainfall during the monitoring period (06/2006 to 10/2008). 0 500 1000 1500 2000 2500 3000 3500 4000 0 25 50 75 100 125 150 175 200 Cumulative rainfall, mm Daily rainfall, mm Date (yy/mm) 06/04 06/06 06/08 06/10 06/12 07/02 07/04 07/06 07/08 07/10 07/12 08/02 08/04 08/06 08/08 08/10 (a) Daily and accumulated rainfall (06/2006 to 10/2008) 0 20 40 60 80 100 0 10 20 30 40 50 60 70 80 90 100 Occurrence Frequency (%) Daily Rainfall (mm) 68% 76% (b) Annual rainfall frequency curve (2007) 0 100 200 300 400 0 300 600 900 1200 0 40 80 120 0 20 40 60 80 100 120 140 0 2 4 6 8 10 Tss (mg/L) Time (min) Turbidity (NTU) Oil & Grease (mg/L) Flow (m 3 /hr) Flow Tss In Tss Out Turbidity In Turbidity Out O&G In O&G Out (a) TSS, Turbidity, Oil & Grease Time (min) Flow (m 3 /hr) Flow Cd In Cd Out Pb In Pb Out Zn In Zn Out 0 100 200 300 400 0 300 600 900 1200 0 40 80 120 160 200 0 2000 4000 6000 8000 0 500 1000 1500 Cd (ug/L) Pb (ug/L) Zn (ug/L) (b) Cd, Pb, Zn Fig. 3. Multiple hydro-and polluto graphs for the 07/09/2007 storm event. Appropriate Methods in Determining the Event Mean Concentration and Pollutant Removal Efficiency of a Best Management Practice 219 http://www.eer.or.kr 3.3. Pollutant Removal Efficiency The treatment capability of the swirl and filtration system was evaluated based on the total monitored storm events using four efficiency determination methods, including the ER, SOL, ROL and ROR methods. The efficiencies were also determined for each corresponding rainfall ranges. Linear correlations be- tween the methods were displayed in the scatter plot matrix (SPLOM) in Fig. 6 and probability matrix in Table 3. As revealed by the linear regression lines in SPLOM, the overall average ef- ficiencies of the four methods were all positively correlated, with the exception of the >20 mm range. This result suggests that the efficiency of the system was highly variable when the storm event has greater than 20 mm of rainfall. Moreover, it also proves that the system is more efficient for storm events having less than 20 mm, and even better 10 mm of rainfall. The design of a facility for the treatment of stormwater runoff usually employs rainfall during which the first flush occurs because treating all, or a larger volume of runoff is impractical and uneconomical. Therefore, achieving high treatment efficiencies is still difficult (e.g. 90 to 100% pollutant removal). Comparing the four methods, the ROR method appeared to be the most highly and significantly correlated with the other three methods, with a minimum Pearson correlation coefficient (r) of r = 0.967 (P=0.002). The SOL method was next, and also significantly correlated with the other three methods, with a minimum r value of 0.926 (P=0.0027). On the other hand, the ER and ROL methods were not significantly correlated (P=0.343). Although the other methods are always useful to assess the over- all average efficiency of the treatment system, the ROR method gave the highest confidence in reporting the overall efficiency of the treatment system. The ROR method; therefore, would be suitable for application to other BMP monitoring studies. The overall average removal efficiency of the swirl and filtra- tion system calculated using the four methods is shown in Fig. 7. The highest removal efficiency was achieved for oil and grease (O&G) with greater than 70% removal. The other pollutant pa- rameters merely attained less than 50% removal efficiencies. The ROF method showed the highest efficiency compared to the other three methods, with the exceptions of TSS and DOC; however, the differences were not significant. The ER method, which considers only the EMC in the calculation of the removal efficiency, yielded significantly lower efficiency value for TSS (P=0.009). In addition, the SOL and ROL methods also signifi- cantly affected the O&G removal efficiency (SOL, P=0.03; ROL, P=0.029). In summary, the computed removal efficiencies var- ied because only the EMC or mass loads of pollutant were con- sidered. Therefore, the ROR method provided an unbiased ap- 3.2.2. Event Mean Concentration The average pollutant concentrations of typical water quality parameters in urban runoff studies are generally quantified by means of the EMC. Given that stormwater runoff s associated with high uncertainties due to site and rainfall characteristics, the EMC values can also be affected, as reflected by the wide dis- tribution and deviation of the EMC values found in several stud- ies in Korea [6, 17, 18]. For example, the pollutant EMC values based on 12 stormwater runoff studies by Kim et al. [17], con- ducted at parking lots, resulted in average EMC values of 115, 35, 4 and 1 mg/L for TSS, BOD, TN and TP, respectively. These results were higher compared to those found in this study. Cli- mate, weather and geography tend to affect average EMC values. It is possible that a very accurate (statistical) analysis should be performed to eliminate the uncertainties in predicting EMC val- ues. Fig. 4 shows the comparison of the calculated EMC values for various pollutants with respect to the three rainfall ranges (i.e., <10 mm, 10 to 20 mm and >20 mm rainfall), both cumu- latively (i.e. using arithmetic average of the total events) and modified (calculated by using Eq. 2). All measured parameters exhibited significant differences between the inlet and outlet EMC values (P<0.01) for the three rainfall ranges, with the ex- ceptions of the TSS (P=0.037) and turbidity (P=0.11). Based on the graphs, an apparent trend was observed in the relationship between the EMC and rainfall depth; the greater the rainfall, the smaller the EMC, and vice versa. Likewise, increases in the rainfall and rainfall intensity corresponded with the decrease average EMC values. Due to long duration and heavy rainfall, the average EMC value will be small. Therefore, it is safe to as- sume that rainfall is one of the factors affecting the differences in the EMC values, as well as the loading and flow or volume of runoff. Concurrently, rainfall can be included in the calculation of representative (overall) EMC values. Customarily, the overall EMC value is reported by arithmetically averaging the individual EMC for each storm event over the entire monitoring period. A modified EMC value was introduced in this study to account for the distribution of rainfall (termed the ‘rainfall ratio’ in Table 1). This idea opposes the previous discussion (as depicted in Fig. 4), which showed an inverse relationship between the EMC and rainfall depth. Therefore, it follows that the EMC is dependent on the rainfall ratio. Comparing the overall and modified EMC values for various pollutant parameters (Fig. 4), the modified EMC values were smaller by 13±12% (mean±standard deviation) than the overall EMC values. Nevertheless, the modified EMC was highly correlated with the overall EMC, as verified by the linear fit in Fig. 5. Table 2. Summary of the monitored event data (n=22) Parameter Min/Max Median Mean±SD Sampling frequency ratio a) ADD (day) 1/33 5 7.3 ± 7.3 NA Total rainfall (mm) <10 mm 1.5/55.5 10.5 17.9 ± 18.1 0.5 10 to 20 mm 0.2 >20 mm 0.3 Runoff duration (hr) 1/14 6.5 6.6 ± 4.2 NA ADD: antecedent dry day, NA: not applicable. a) Ratio of sampling trips (for each range) to total sampling trips . Marla C. Maniquiz, Jiyeon Choi, Soyoung Lee, Hye Jin Cho, Lee-Hyung Kim 220 DOI:10.4491/eer.2010.15.4.215 Fig. 4. Inlet and outlet pollutant event mean concentrations (EMC) ± standard error for each rainfall range and the cumulative EMC during the monitoring period (06/2006 to 10/2008). The modified EMC value at the inlet is denoted by the black dashed line. Appropriate Methods in Determining the Event Mean Concentration and Pollutant Removal Efficiency of a Best Management Practice 221 http://www.eer.or.kr 50 40 30 20 10 0 0 10 20 30 40 50 60 70 Overall EMC Modif ied EMC R 2 = 0.987 p = 0.00478 Fig. 5. Linear fit and correlation between the modified event mean concentration (EMC) and overall EMC at the inlet. Fig. 7. Overall average removal efficiency of the swirl and filtration system using the four efficiency determination methods (ER, SOL, ROL and ROR) during the monitoring period (06/2006 to 10/2008). ER10ER1020ER20ERSOL10SOL1020SOL20SOLROL10ROL1020ROL20ROL ER10 ROR ER1020 ER20 ER SOL10 SOL1020 SOL20 SOL ROL10 ROL1020 ROL20 ROL ROR Fig. 6. Scatter plot matrix (SPLOM) of various efficiency determination methods showing the regression line with 95% upper and lower confi- dence intervals using a linear smoother method; and the density in diagonal cells, as displayed by the histogram. Marla C. Maniquiz, Jiyeon Choi, Soyoung Lee, Hye Jin Cho, Lee-Hyung Kim 222 DOI:10.4491/eer.2010.15.4.215 proximation of the average removal efficiency since it takes into account both the EMC and rainfall frequency. Indeed, the rain- fall characteristics govern the factors affecting the removal ef- ficiency. For instance, for the August 26, 2006 storm event (data not shown), where the rainfall intensity was highest at 15 mm/hr (48.5 mm rainfall), overflow occurred in the sedimentation tank, which resulted in a low removal efficiency value. 4. Conclusions The swirl and filtration system evaluated in this study is one of the many types of BMP previously and currently employed for managing stormwater runoff in Korea. However, due to vari- able site and climatic characteristics, it is not easy to suggest a general management strategy for the control of (NPS) pollutants in stormwater runoff. For this reason, investigations on the ef- ficiency of treatment facilities are required. While long term monitoring of storm events is best for eliminating the uncer- tainties and accurately predicting the efficiency of systems, this is laborious and costly. Thus, the appropriate determination of the EMC, which is a critical and commonly used factor in esti- mating the pollutant removal efficiency of a treatment system, is equally important. In this study, a modified EMC calcula- tion method and a more precise pollutant removal efficiency method (ROR) were developed, with the inclusion of rainfall as a factor. Eventually, a standard method for calculating the EMC and pollutant removal efficiency should be used for uniformity and appropriate representation of various BMPs. Based on our results, the modified EMC and ROR methods were found to be significantly correlated to the existing methods, and proven to be appropriately feasible for application. Finally, the efficiency values attained in the study of the swirl and filtration system were only satisfactory. To effectively manage stormwater runoff, both the runoff quality and quantity should be addressed. This could be achieved by restoring the water circulation lost due to excessive urbanization and by incorporating filtration and infil- tration processes or through pollutant uptake by plants. Further research is still needed to investigate and improve the pollutant removal efficiencies of these BMPs. Acknowledgments This research was supported by the Korea Institute of Con- struction Technology (KICT) under the research project entitled “Development of water circulation system for urban road” (Ref- erence No. 2010-0792). The authors are grateful to their support. References 1. Ministry of Environment (MOE). Water environment man- agement master plan. Gwacheon: MOE; 2006. 2. Ministry of Environment (MOE). The strategy of water con- trol in four major rivers in Korea. Gwacheon: MOE; 2004. 3. Bannerman RT, Owens DW, Dodds RB, Hornewer NJ. Sourc- es of pollutants in Wisconsin stormwater. Wat. Sci. Technol. 1993;28:241-259. 4. U.S. Environmental Protection Agency (U.S. EPA). Hand- book: urban runoff pollution prevention and control plan- ning, Washington, D.C.: U.S. EPA; 1993. Report No.: EPA 625- R-93/004. 5. Hatt BE, Fletcher TD, Deletic A. Treatment performance of gravel filter media: implications for design and application of stormwater infiltration systems. Wat. Res. 2007;40:2513- 2524. 6. Kim LH, Lee SH. Characteristics of pollutants and dynamic EMCs in a parking lot and bridge during storms. J. Korean Soc. Wat. Qual. 2005;21:248-255. 7. Choi JD, Choi YH, Lim KJ, Shin YC. Soil erosion measurement and control techniques. In: International Workshop on New- ly Developed Technology for Soil and Water Conservation; 2005 May 31-Jun 3; Suwon, Korea. 8. Jung YJ, Stenstrom MK, Jung DI, Kim LH, Min KS. National pilot projects for management of diffuse pollution in Korea. Table 3. Matrix of Bonferroni probabilities (P) from linear regressions on the various efficiency determination methods ER <10 0 ER 10-20 0.065 0 ER >20 - a) - 0 ER - 0.007 0.403 0 SOL <10 0 0.133 - - 0 SOL 10-20 0.057 0 - 0.021 0.073 0 SOL >20 - - - - - - 0 SOL 0.006 0.002 - 0.027 0.008 0.001 - 0 ROL <10 0 0.096 - - 0 0.052 - 0.005 0 ROL 10-20 0.125 0.002 - 0.059 0.137 0 - 0.003 0.11 0 ROL >20 - 0.333 - - - 0.116 - - - 0.117 0 ROL 0 0.043 - 0.343 0.001 0.023 - 0 0.001 0.032 - 0 ROR 0.038 0 - 0.002 0.067 0.001 - 0 0.045 0.01 - 0.009 0 ER <10 ER 10-20 ER >20 ER SOL <10 SOL 10-20 SOL >20 SOL ROL <10 ROL 10-20 ROL >20 ROL ROR ER: efficiency ratio, SOL: summation of loads, ROL: regression of loads, ROR: rainfall occurrence ratio . a) - indicates P>0.9. The P values of the four general methods were shaded for convenience in comparison. Appropriate Methods in Determining the Event Mean Concentration and Pollutant Removal Efficiency of a Best Management Practice 223 http://www.eer.or.kr Desalination 2008;226:97-105. 9. Winer, R. National Pollutant Removal Performance Database for Stormwater Treatment Practices. 2nd Ed. Prepared by Center for Watershed Protection for U.S. EPA Office of Sci- ence and Technology; 2000. 10. Kim LH, Jeong SM, Ko SO. Determination of first flush cri- teria using dynamic EMCs (event mean concentrations) on highway stormwater runoff. Wat. Sci. Technol. 2007;55:71-77. 11. Greenberg AE, Clesceri LS, Eaton AD, American Public Health Association (APHA), American Water Works Associa- tion, Water Environment Federation. Standard methods for the examination of water and wastewater. 18th ed. Washing- ton, D.C.: APHA; 1992. 12. Marsalek J. Pollution due to urban runoff: unit loads and abatement measures, PLUARG. Windsor, Ontario: Interna- tional Joint Commission; 1978. 13. Irish Jr. LB, Barrett ME, Malina Jr. JF, Charbeneau RJ. Use of regression models for analyzing highway storm-water loads. J. Environ. Eng. 1998;124:987-993. 14. U.S. Environmental Protection Agency (U.S. EPA). Urban stormwater BMP performance monitoring, Washington, D.C.: U.S. EPA; 2002. Report No.: EPA-821-B-02-001. 15. U.S. Environmental Protection Agency (U.S. EPA). Results of the Nationwide Urban Runoff Program. Vol. I: Final report. Washington, D.C.: Water Planning Division, U.S. Environ- mental Protection Agency; 1983. 16. Martin EH, Smoot JL. Constituent-load changes in urban storm water runoff routed through a detention pond-wet- land system in central Florida. Tallahassee: U.S. Geological Survey; 1986. Report No.: Water resources investigation re- port 85-4310. 17. Kim LH, Ko SO, Jeong SM, Yoon JY. Characteristics of wash- off pollutants and dynamic EMCs in parking lots and bridges during a storm. Sci. Total Environ. 2007;376:178-784. 18. Lee CS, Seo GT, Lee JH, Yoon YS, You JJ, Sin CK. Long term monitoring of storm surface runoff from urban pavement road in Korea. Environ. Eng. Res. 2008;13:184-191. . pre-treatment of the storm- Fig. 1. Schematic of the swirl and filtration system. Appropriate Methods in Determining the Event Mean Concentration and Pollutant Removal Efficiency of a Best Management. was observed in the relationship between the EMC and rainfall depth; the greater the rainfall, the smaller the EMC, and vice versa. Likewise, increases in the rainfall and rainfall intensity. Multiple hydro -and polluto graphs for the 07/09/2007 storm event. Appropriate Methods in Determining the Event Mean Concentration and Pollutant Removal Efficiency of a Best Management Practice 219 http://www.eer.or.kr 3.3.